Changes for page 03 Specifications
Last modified by Mora Zhou on 2023/12/22 10:48
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PLC Editor.WebHome 1 +PLC Editor.LX3V programing manual.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Mora1 +XWiki.admin - Content
-
... ... @@ -1,4 +1,4 @@ 1 -= **General specifications** = 1 += **3.1 General specifications** = 2 2 3 3 (% border="2" class="table-bordered" %) 4 4 |=(% style="width: 198px;" %)**Temperature**|=(% colspan="6" style="width: 877px;" %)Working temperature: 0~~55 ^^O^^C storage temperature: -20~~70^^ O^^C ... ... @@ -19,11 +19,11 @@ 19 19 ※1 20 20 21 21 (% style="text-align:center" %) 22 -[[image:4.Product specifications_html_3a894746e1e6cfe1.jpg||height="108" width="750" class="img-thumbnail"]]22 +[[image:4.Product specifications_html_3a894746e1e6cfe1.jpg||class="img-thumbnail" height="108" width="750"]] 23 23 24 -= **Electricity specification** = 24 += **3.2 Electricity specification** = 25 25 26 -== **AC power type** == 26 +== **3.2.1 AC power type** == 27 27 28 28 (% border="2" class="table-bordered" %) 29 29 |=**Model**|=LX3V-0806/1208/1212/1410/1412MX-A|=LX3V-1616/2416/2424/3624MX-A ... ... @@ -36,12 +36,9 @@ 36 36 |**Power**|20W|50W 37 37 |**Sensor power supply**|DC 24V 70mA|DC 24V 70mA 38 38 39 -(% class="box infomessage" %) 40 -((( 41 41 **✎Note:** The input current part (7mA / 1 point, 5mA / 1 point) is also included. 42 -))) 43 43 44 -== **DC power type** == 41 +== **3.2.2 DC power type** == 45 45 46 46 ((( 47 47 (% border="2" class="table-bordered" %) ... ... @@ -53,7 +53,7 @@ 53 53 |(% style="width:256px" %)**Impulse current**|(% style="width:818px" %)Less than 15A 1ms/AC 100V 54 54 |(% style="width:256px" %)**Power**|(% style="width:818px" %)Less than 30W(not include the power of the expansion module) 55 55 56 -= **Input specification** = 53 += **3.3 Input specification** = 57 57 ))) 58 58 59 59 The specifications of the basic units of the LX series programmable controllers are shown in the table2-1 below: ... ... @@ -76,12 +76,9 @@ 76 76 The diagram is NPN connection method, if S/S is connected to negative pole, X is connected to positive pole, that is PNP connection method. 77 77 ))) 78 78 79 -(% class="box infomessage" %) 80 -((( 81 81 **✎Note:** After X002 is 4.7KΩ. 82 -))) 83 83 84 -= **Output specification** = 78 += **3.4 Output specification** = 85 85 86 86 (% border="2" class="table-bordered" %) 87 87 |=(% colspan="2" %)**Output type**|=**Relay output**|=**Transistor output** ... ... @@ -109,24 +109,24 @@ 109 109 Please connect the DC inductive load and the freewheeling diode in parallel. Otherwise, the contact life will be significouldtly reduced. Freewheeling diode reverse withstand voltage is 5 to 10 times the load voltage, the forward current value is higher than the load current. 110 110 111 111 (% style="text-align:center" %) 112 -[[image:4.Product specifications_html_35e4656eabe3d9d5.jpg||height="209" width="650" class="img-thumbnail"]]106 +[[image:4.Product specifications_html_35e4656eabe3d9d5.jpg||class="img-thumbnail" height="209" width="650"]] 113 113 114 114 If the load is AC inductive, connect the load and surge absorber in parallel could reduce the noise. 115 115 116 116 (% style="text-align:center" %) 117 -[[image:4.Product specifications_html_f49960fdc2323ec5.jpg||height="208" width="650" class="img-thumbnail"]]111 +[[image:4.Product specifications_html_f49960fdc2323ec5.jpg||class="img-thumbnail" height="208" width="650"]] 118 118 119 119 It is best to use the plc output contacts on the same phase as Figure 2-3 shown below. 120 120 121 121 (% style="text-align:center" %) 122 -[[image:4.Product specifications_html_813dbe36c8ac8144.jpg||height="272" width="600" class="img-thumbnail"]]116 +[[image:4.Product specifications_html_813dbe36c8ac8144.jpg||class="img-thumbnail" height="272" width="600"]] 123 123 124 124 It is very dangerous to connect the FWD and REV contact at the same time. In addition to adding the interlocking control of the program in the plc, there also should be an interlock outside the PLC. 125 125 126 126 (% style="text-align:center" %) 127 -[[image:4.Product specifications_html_6d23c8052386163.jpg||height="194" width="650" class="img-thumbnail"]]121 +[[image:4.Product specifications_html_6d23c8052386163.jpg||class="img-thumbnail" height="194" width="650"]] 128 128 129 -= **Product naming rule** = 123 += **3.5 Product naming rule** = 130 130 131 131 The model of the plc could be found on the label on the side of the product. 132 132 ... ... @@ -133,7 +133,7 @@ 133 133 **[The basic unit's model name constitutes]** 134 134 135 135 (% style="text-align:center" %) 136 -[[image:4.Product specifications_html_85dc603ba603e964.jpg||height="135" width="600" class="img-thumbnail"]]130 +[[image:4.Product specifications_html_85dc603ba603e964.jpg||class="img-thumbnail" height="135" width="600"]] 137 137 138 138 The meaning of 1~~6 is as below. 139 139