Changes for page 06 Instructions
Last modified by Devin Chen on 2024/10/15 14:46
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -06 Instruction s1 +06 Instruction - Content
-
... ... @@ -1,322 +1,0 @@ 1 -= **6.1.1 Basic program instruction list** = 2 - 3 -(% class="table-bordered" %) 4 -|**Instruction type**|**Instruction**|**Description**|((( 5 -**LX3V(1S)** 6 -)))|**LX3V (2N)**|**LX3VP**|**LX3VE** 7 -|(% rowspan="25" %)[[Basic instructions>>path:/wiki/plc/view/2-User%20manual/6.Instruction/01.Basic%20instruction/]]|LD|Operation contact type NO (normally open)|¡|¡|¡|¡ 8 -|LDI|Operation contact type NC (normally closed)|¡|¡|¡|¡ 9 -|OUT|Final logical operation type coil drive|¡|¡|¡|¡ 10 -|AND|Serial connection of NO(normally open)|¡|¡|¡|¡ 11 -|ANI|Serial logical, operation contact type NC(normally closed) contacts|¡|¡|¡|¡ 12 -|OR|Parallel, connection of NO (normally open) contacts|¡|¡|¡|¡ 13 -|ORI|Parallel, connection of NC (normally closed) contacts|¡|¡|¡|¡ 14 -|LDP|Initial logical, operation -Rising edge pulse|¡|¡|¡|¡ 15 -|LDF|Initial logical, operation falling/trailing edge pulse|¡|¡|¡|¡ 16 -|ANDP|Serial connection of Rising edge pulse|¡|¡|¡|¡ 17 -|ANDF|Serial connection of falling/ trailing edge pulse|¡|¡|¡|¡ 18 -|ORP|Parallel, connection of NO Rising edge pulse|¡|¡|¡|¡ 19 -|ORF|Parallel connection of Falling/trailing edge pulse|¡|¡|¡|¡ 20 -|ORB|Serial connection of multiple parallel circuits|¡|¡|¡|¡ 21 -|ANB|Serial connection of multiple parallel circuits|¡|¡|¡|¡ 22 -|MPS|Stores the current result of the internal PLC operations|¡|¡|¡|¡ 23 -|MRD|Reads the current result of the internal PLC operations|¡|¡|¡|¡ 24 -|MPP|Pops (recalls and removes) the currently stored result|¡|¡|¡|¡ 25 -|MC|Denotes the start of a master control block|¡|¡|¡|¡ 26 -|MCR|Denotes the end of a master control block|¡|¡|¡|¡ 27 -|INV|Invert the current result of the internal PLC operations|¡|¡|¡|¡ 28 -|PLS|Rising edge pulse|¡|¡|¡|¡ 29 -|PLF|Falling / trailing edge pulse|¡|¡|¡|¡ 30 -|SET|Sets a bit device permanently ON|¡|¡|¡|¡ 31 -|RST|Resets a bit device permanently OFF|¡|¡|¡|¡ 32 - 33 -= **6.1.2 Step ladder instructions list** = 34 - 35 -(% class="table-bordered" %) 36 -|**Instruction type**|**Instruction**|**Description**|((( 37 -**LX3V** 38 - 39 -**(1S)** 40 -)))|**LX3V (2N)**|**LX3VP**|**LX3VE** 41 -|(% rowspan="2" %)[[Step ladder instructions>>path:/wiki/plc/view/2-User%20manual/6.Instruction/17.Step%20control%20instructions/]]|STL|STL programming start instruction|¡|¡|¡|¡ 42 -|RET|STL programming end instruction|¡|¡|¡|¡ 43 - 44 -= **6.1.3 Program Flow instruction list** = 45 - 46 -(% class="table-bordered" %) 47 -|(% style="width:241px" %)**Instruction type**|(% style="width:129px" %)**Instruction**|(% style="width:306px" %)**Description**|((( 48 -**LX3V** 49 - 50 -**(1S)** 51 -)))|**LX3V (2N)**|**LX3VP**|**LX3VE** 52 -|(% rowspan="7" style="width:241px" %)[[Program flow instructions>>path:/wiki/plc/view/2-User%20manual/6.Instruction/02.Program%20flow/]]|(% style="width:129px" %)CJ|(% style="width:306px" %)Conditional jump|¡|¡|¡|¡ 53 -|(% style="width:129px" %)CALL|(% style="width:306px" %)Call Subroutine|¡|¡|¡|¡ 54 -|(% style="width:129px" %)EI|(% style="width:306px" %)Enable Interrupt|¡|¡|¡|¡ 55 -|(% style="width:129px" %)DI|(% style="width:306px" %)Disable Interrupt|¡|¡|¡|¡ 56 -|(% style="width:129px" %)WDT|(% style="width:306px" %)Watchdog Timer|¡|¡|¡|¡ 57 -|(% style="width:129px" %)FOR|(% style="width:306px" %)Start of a For/Next Loop|¡|¡|¡|¡ 58 -|(% style="width:129px" %)NEXT|(% style="width:306px" %)End a For/Next Loop|¡|¡|¡|¡ 59 - 60 -= **6.1.4 Move and Compare instruction list** = 61 - 62 -(% class="table-bordered" %) 63 -|(% style="width:314px" %)**Instruction type**|(% style="width:146px" %)**Instruction**|**Description**|((( 64 -**LX3V** 65 - 66 -**(1S)** 67 -)))|**LX3V (2N)**|**LX3VP**|**LX3VE** 68 -|(% rowspan="10" style="width:314px" %)[[Move and Compare instructions>>path:/wiki/plc/view/2-User%20manual/6.Instruction/03.Move%20and%20campare/]]|(% style="width:146px" %)CMP|Compare |¡|¡|¡|¡ 69 -|(% style="width:146px" %)ZCP|Zone compare|¡|¡|¡|¡ 70 -|(% style="width:146px" %)MOV|Move |¡|¡|¡|¡ 71 -|(% style="width:146px" %)SMOV|Shift move|-|¡|¡|¡ 72 -|(% style="width:146px" %)CML|Compliment |-|¡|¡|¡ 73 -|(% style="width:146px" %)BMOV|Block move|¡|¡|¡|¡ 74 -|(% style="width:146px" %)FMOV|Fill move|-|¡|¡|¡ 75 -|(% style="width:146px" %)XCH|Exchange |-|¡|¡|¡ 76 -|(% style="width:146px" %)BCD|Binary coded decimal|¡|¡|¡|¡ 77 -|(% style="width:146px" %)BIN|Binary |¡|¡|¡|¡ 78 - 79 -= **6.1.5 Arithmetic and Logical Operations instruction list** = 80 - 81 -(% class="table-bordered" %) 82 -|(% style="width:358px" %)**Instruction type**|(% style="width:162px" %)**Instruction**|(% style="width:206px" %)**Description**|((( 83 -**LX3V** 84 - 85 -**(1S)** 86 -)))|**LX3V (2N)**|**LX3VP**|**LX3VE** 87 -|(% rowspan="10" style="width:358px" %)[[Arithmetic and Logical Operations instructions>>path:/wiki/plc/view/2-User%20manual/6.Instruction/06.Arithmetic%20and%20logical%20operations/]]|(% style="width:162px" %)ADD|(% style="width:206px" %)Addition |¡|¡|¡|¡ 88 -|(% style="width:162px" %)SUB|(% style="width:206px" %)Subtraction |¡|¡|¡|¡ 89 -|(% style="width:162px" %)MUL|(% style="width:206px" %)Multiplication |¡|¡|¡|¡ 90 -|(% style="width:162px" %)DIV|(% style="width:206px" %)Division |¡|¡|¡|¡ 91 -|(% style="width:162px" %)INC|(% style="width:206px" %)Increment|¡|¡|¡|¡ 92 -|(% style="width:162px" %)DEC|(% style="width:206px" %)Decrement|¡|¡|¡|¡ 93 -|(% style="width:162px" %)WAND|(% style="width:206px" %)Word AND|¡|¡|¡|¡ 94 -|(% style="width:162px" %)WOR|(% style="width:206px" %)Word OR|¡|¡|¡|¡ 95 -|(% style="width:162px" %)WXOR|(% style="width:206px" %)Word exclusive OR|¡|¡|¡|¡ 96 -|(% style="width:162px" %)NEG|(% style="width:206px" %)Negation |-|¡|¡|¡ 97 - 98 -= **6.1.6 Rotation and Shift instruction list** = 99 - 100 -(% class="table-bordered" %) 101 -|**Instruction type**|(% style="width:134px" %)**Instruction**|(% style="width:280px" %)**Description**|((( 102 -**LX3V** 103 - 104 -**(1S)** 105 -)))|**LX3V (2N)**|**LX3VP**|**LX3VE** 106 -|(% rowspan="10" %)[[Rotation and Shift instructions>>path:/wiki/plc/view/2-User%20manual/6.Instruction/08.Rotation%20and%20shift/]]|(% style="width:134px" %)ROR|(% style="width:280px" %)Rotation right|¡|¡|¡|¡ 107 -|(% style="width:134px" %)ROL|(% style="width:280px" %)Rotation left|¡|¡|¡|¡ 108 -|(% style="width:134px" %)RCR|(% style="width:280px" %)16-bit rotation right with carry|-|¡|¡|¡ 109 -|(% style="width:134px" %)RCL|(% style="width:280px" %)16-bit rotation left with carry|-|¡|¡|¡ 110 -|(% style="width:134px" %)SFTR|(% style="width:280px" %)(bit) shift right|¡|¡|¡|¡ 111 -|(% style="width:134px" %)SFTL|(% style="width:280px" %)(bit) shift left|¡|¡|¡|¡ 112 -|(% style="width:134px" %)WSFR|(% style="width:280px" %)word shift right|-|¡|¡|¡ 113 -|(% style="width:134px" %)WSFL|(% style="width:280px" %)word shift left|-|¡|¡|¡ 114 -|(% style="width:134px" %)SFWR|(% style="width:280px" %)shift register write|¡|¡|¡|¡ 115 -|(% style="width:134px" %)SFRD|(% style="width:280px" %)shift register read|¡|¡|¡|¡ 116 - 117 -= **6.1.7 Data operation instruction list** = 118 - 119 -(% class="table-bordered" %) 120 -|(% style="width:292px" %)**Instruction type**|(% style="width:135px" %)**Instruction**|(% style="width:266px" %)**Description**|((( 121 -**LX3V** 122 - 123 -**(1S)** 124 -)))|**LX3V (2N)**|**LX3VP**|**LX3VE** 125 -|(% rowspan="11" style="width:292px" %)[[Data operation instructions>>path:/wiki/plc/view/2-User%20manual/6.Instruction/04.Data%20operation/]]|(% style="width:135px" %)ZRST|(% style="width:266px" %)Zone reset|¡|¡|¡|¡ 126 -|(% style="width:135px" %)DECO|(% style="width:266px" %)Decode |¡|¡|¡|¡ 127 -|(% style="width:135px" %)ENCO|(% style="width:266px" %)Encode |¡|¡|¡|¡ 128 -|(% style="width:135px" %)SUM|(% style="width:266px" %)The sum of active bits|-|¡|¡|¡ 129 -|(% style="width:135px" %)BON|(% style="width:266px" %)Check specified bit status|-|¡|¡|¡ 130 -|(% style="width:135px" %)MEAN|(% style="width:266px" %)Mean |-|¡|¡|¡ 131 -|(% style="width:135px" %)ANS|(% style="width:266px" %)(timed) annunciator set|-|¡|¡|¡ 132 -|(% style="width:135px" %)ANR|(% style="width:266px" %)Annunciator reset|-|¡|¡|¡ 133 -|(% style="width:135px" %)SQR|(% style="width:266px" %)Square root|-|¡|¡|¡ 134 -|(% style="width:135px" %)FLT|(% style="width:266px" %)Float |-|¡|¡|¡ 135 -|(% style="width:135px" %)SWAP|(% style="width:266px" %)High and low bit conversion|-|¡|¡|¡ 136 - 137 -= **6.1.8 High-speed Processing Instruction** = 138 - 139 -(% class="table-bordered" %) 140 -|(% style="width:290px" %)**Instruction type**|(% style="width:137px" %)**Instruction**|**Description**|((( 141 -**LX3V** 142 - 143 -**(1S)** 144 -)))|**LX3V (2N)**|**LX3VP**|**LX3VE** 145 -|(% rowspan="10" style="width:290px" %)[[High-speed Processing Instruction>>path:/wiki/plc/view/2-User%20manual/6.Instruction/07.High%20speed%20process/]]|(% style="width:137px" %)REF|Refresh|¡|¡|¡|¡ 146 -|(% style="width:137px" %)REFF|Refresh and filter adjust|-|¡|¡|¡ 147 -|(% style="width:137px" %)MTR|Input matrix|¡|¡|¡|¡ 148 -|(% style="width:137px" %)DHSCR|High speed counter set|¡|¡|¡|¡ 149 -|(% style="width:137px" %)DHSCS|High speed counter reset|¡|¡|¡|¡ 150 -|(% style="width:137px" %)DHSZ|High speed counter zone compare|-|¡|¡|¡ 151 -|(% style="width:137px" %)SPD|Speed detect|¡|¡|¡|¡ 152 -|(% style="width:137px" %)PLSY|16-bit pulse Y output|¡|¡|¡|¡ 153 -|(% style="width:137px" %)PWM|Pulse width modulation|¡|¡|¡|¡ 154 -|(% style="width:137px" %)PLSR|Ramp pulse output|¡|¡|¡|¡ 155 - 156 -= **6.1.9 ECAM instruction list** = 157 - 158 -(% class="table-bordered" %) 159 -|**Instruction type**|**Instruction**|**Description**|((( 160 -**LX3V** 161 - 162 -**(1S)** 163 -)))|**LX3V (2N)**|**LX3VP**|**LX3VE** 164 -|(% rowspan="3" %)[[ECAM instruction>>path:/wiki/plc/view/2-User%20manual/6.Instruction/10.ECAM/]]|DECAM|ECAM configuration|-|-|-|¡ 165 -|DEGEAR|Electronic gear configuration|-|-|-|¡ 166 -|ECAMTBX|Create E-CAM datasheet|-|-|-|¡ 167 - 168 -= **6.1.10 External I/O Devices instruction list** = 169 - 170 -(% class="table-bordered" %) 171 -|**Instruction type**|**Instruction**|**Description**|((( 172 -**LX3V** 173 - 174 -**(1S)** 175 -)))|**LX3V (2N)**|**LX3VP**|**LX3VE** 176 -|(% rowspan="12" %)[[External I/O device instruction>>path:/wiki/plc/view/2-User%20manual/6.Instruction/09.External%20IO%20Devices/]]|TKY|Ten key input|-|¡|¡|¡ 177 -|HKY|Hexadecimal input|-|¡|¡|¡ 178 -|DSW|Digital switch (thumbwheel input)|¡|¡|¡|¡ 179 -|SEGD|Seven segment decoder|-|¡|¡|¡ 180 -|SEGL|Seven segment with latch|¡|¡|¡|¡ 181 -|ARWS|Arrow switch|-|¡|¡|¡ 182 -|ASC|ASCII code|-|¡|¡|¡ 183 -|PR|“print” to a display|-|¡|¡|¡ 184 -|FROM|Read from a special function block|¡|¡|¡|¡ 185 -|TO|Write to a special function block|¡|¡|¡|¡ 186 -|GRY|Converts binary integer to GRAY code|-|¡|¡|¡ 187 -|GBIN|Converts GRAY CODE to binary|-|¡|¡|¡ 188 - 189 -= **6.1.11 External Devices instruction list** = 190 - 191 -(% class="table-bordered" %) 192 -|**Instruction type**|**Instruction**|**Description**|((( 193 -**LX3V** 194 - 195 -**(1S)** 196 -)))|**LX3V (2N)**|**LX3VP**|**LX3VE** 197 -|(% rowspan="9" %)[[External devices instruction>>path:/wiki/plc/view/2-User%20manual/6.Instruction/13.External%20Device%20SER%20instruction/]]|RS|RS communications|¡|¡|¡|¡ 198 -|RS2|RS2 communications|¡|¡|¡|¡ 199 -|CPAVL|Serial port settings|¡|¡|¡|¡ 200 -|CPAVL|Ethernet port settings|¡|¡|¡|¡ 201 -|PRUN|Octal bit transmission|¡|¡|¡|¡ 202 -|ASCI|hexadecimal to ASCII|¡|¡|¡|¡ 203 -|HEX|ASCII to hexadecimal|¡|¡|¡|¡ 204 -|CCD|check code|¡|¡|¡|¡ 205 -|PID|PID control loop|¡|¡|¡|¡ 206 - 207 -= **6.1.12 Floating Point instruction list** = 208 - 209 -(% class="table-bordered" %) 210 -|**Instruction type**|**Instruction**|**Description**|((( 211 -**LX3V** 212 - 213 -**(1S)** 214 -)))|**LX3V (2N)**|**LX3VP**|**LX3VE** 215 -|(% rowspan="22" %)[[Floating point instruction>>path:/wiki/plc/view/2-User%20manual/6.Instruction/14.Floating%20calculation/]]|DECMP|Binary floating point data compare|-|¡|¡|¡ 216 -|DEZCP|Binary floating point zone compare|-|¡|¡|¡ 217 -|DEBCD|Binary to BCD floating point data conversion|-|¡|¡|¡ 218 -|DEBIN|BCD to Binary floating point data conversion|-|¡|¡|¡ 219 -|DEADD|Binary floating point addition|-|¡|¡|¡ 220 -|DESUB|Binary floating point subtraction|-|¡|¡|¡ 221 -|DEMUL|Binary floating point multiplication|-|¡|¡|¡ 222 -|DEDIV|Binary floating point division|-|¡|¡|¡ 223 -|DESQR|Binary floating point square root|-|¡|¡|¡ 224 -|INT|16-bit binary floating point to integer|-|¡|¡|¡ 225 -|DSIN|Sin operation|-|¡|¡|¡ 226 -|DCOS|Cosine operation|-|¡|¡|¡ 227 -|DTAN|Tangent operation|-|¡|¡|¡ 228 -|DASIN|Calculate radian value, according to the corresponding value of SIN|-|-|¡|¡ 229 -|DSINH|Binary floating point operation of Hyperbolic Sine function SINH|-|-|¡|¡ 230 -|DACOS|Calculate radian value, according to the corresponding value of COS|-|-|¡|¡ 231 -|DCOSH|Binary floating point operation of Hyperbolic Cosine function COSH|-|-|¡|¡ 232 -|DATAN|Calculate radian value, according to the corresponding value of TAN|-|-|¡|¡ 233 -|DTANH|Binary floating point operation of Hyperbolic Tangent function TANH|-|-|¡|¡ 234 -|DEXP|Perform exponent operation of binary floating-point number to base e (2.71828)|-|-|¡|¡ 235 -|DLOG10|Perform common logarithm operation of binary floating-point number to base 10|-|-|¡|¡ 236 -|DLOGE|Perform natural logarithm operation of binary floating-point number to base e (2.71828)|-|-|¡|¡ 237 - 238 -= **6.1.13 Positioning Instruction list** = 239 - 240 -(% class="table-bordered" %) 241 -|**Instruction type**|**Instruction**|**Description**|((( 242 -**LX3V** 243 - 244 -**(1S)** 245 -)))|**LX3V (2N)**|**LX3VP**|**LX3VE** 246 -|(% rowspan="5" %)[[Positioning instruction>>path:/wiki/plc/view/2-User%20manual/6.Instruction/12.Positioning%20control/]]|DABS|Absolute current value read|¡|¡|¡|¡ 247 -|ZRN|Setting of zero return speed|¡|¡|¡|¡ 248 -|PLSV|Variable speed pulse output|¡|¡|¡|¡ 249 -|DRVI|Relative position control|¡|¡|¡|¡ 250 -|DRVA|Absolute position control|¡|¡|¡|¡ 251 - 252 -**4.14 Real Time Clock Control** 253 - 254 -(% class="table-bordered" %) 255 -|**Instruction type**|**Instruction**|**Description**|((( 256 -**LX3V** 257 - 258 -**(1S)** 259 -)))|**LX3V (2N)**|**LX3VP**|**LX3VE** 260 -|(% rowspan="7" %)[[Real time clock control>>path:/wiki/plc/view/2-User%20manual/6.Instruction/05.Real%20time%20clock/]]|TCMP|time compare|¡|¡|¡|¡ 261 -|TZCP|time zone compare|¡|¡|¡|¡ 262 -|TADD|time addition|¡|¡|¡|¡ 263 -|TSUB|time subtraction|¡|¡|¡|¡ 264 -|TRD|read RTC data|¡|¡|¡|¡ 265 -|TWR|set RTC data|¡|¡|¡|¡ 266 -|HOUR|16-bit chronograph|¡|¡|¡|¡ 267 - 268 -= **6.1.14 Handy Instructions list** = 269 - 270 -(% class="table-bordered" %) 271 -|**Instruction type**|**Instruction**|**Description**|((( 272 -**LX3V(1S)** 273 -)))|**LX3V (2N)**|**LX3VP**|**LX3VE** 274 -|(% rowspan="10" %)[[Handy instruction>>path:/wiki/plc/view/2-User%20manual/6.Instruction/11.Handy%20instructions/]]|IST|initial state|¡|¡|¡|¡ 275 -|SER|Search |-|¡|¡|¡ 276 -|ABSD|Absolute drum|¡|¡|¡|¡ 277 -|INCD|Incremental drum|¡|¡|¡|¡ 278 -|TTMR|Teaching timer|-|¡|¡|¡ 279 -|STMR|Special timer - definable|-|¡|¡|¡ 280 -|ALT|Alternate state|¡|¡|¡|¡ 281 -|RAMP|Ramp - variable value|¡|¡|¡|¡ 282 -|ROTC|Rotary table control|-|¡|¡|¡ 283 -|SORT|Sort data|-|¡|¡|¡ 284 - 285 -= **6.1.15 Circular interpolation instruction list** = 286 - 287 -(% class="table-bordered" %) 288 -|**Instruction type**|**Instruction**|**Decryption**|**LX3V**|**LX3VP**|**LX3VE**|**LX3VM** 289 -|(% rowspan="6" %)[[Circular interpolation instruction>>path:/wiki/plc/view/2-User%20manual/6.Instruction/15.Circular%20interpolation%20instruction/]]|G90G01|Absolute position line interpolation|-|-|-|¡ 290 -|G91G01|Relative position line interpolation|-|-|-|¡ 291 -|G90G02|Absolute position of the clockwise circular interpolation|-|-|-|¡ 292 -|G91G02|Relative position clockwise circular interpolation|-|-|-|¡ 293 -|G90G03|Absolute position anticlockwise circular interpolation|-|-|-|¡ 294 -|G91G03|Relative position anticlockwise circular interpolation|-|-|-|¡ 295 - 296 -= **6.1.16 Inline Comparisons Instruction list** = 297 - 298 -(% class="table-bordered" %) 299 -|(% style="width:260px" %)**Instruction type**|(% style="width:107px" %)**Instruction**|(% style="width:345px" %)**Description**|((( 300 -**LX3V** 301 - 302 -**(1S)** 303 -)))|**LX3V (2N)**|**LX3VP**|**LX3VE** 304 -|(% rowspan="19" style="width:260px" %)Inline comparisons instruction|(% style="width:107px" %)LD=|(% style="width:345px" %)Comparison of 16-bit data (==)|¡|¡|¡|¡ 305 -|(% style="width:107px" %)LD>|(% style="width:345px" %)Comparison of 16-bit data (>|¡|¡|¡|¡ 306 -|(% style="width:107px" %)LD<|(% style="width:345px" %)Comparison of 16-bit data (<|¡|¡|¡|¡ 307 -|(% style="width:107px" %)LD<>|(% style="width:345px" %)Comparison of 16-bit data (<>|¡|¡|¡|¡ 308 -|(% style="width:107px" %)LD<=|(% style="width:345px" %)Comparison of 16-bit data (<=)|¡|¡|¡|¡ 309 -|(% style="width:107px" %)LD>=|(% style="width:345px" %)Comparison of 16-bit data (>=)|¡|¡|¡|¡ 310 -|(% style="width:107px" %)AND=|(% style="width:345px" %)Comparison of 16-bit data (==)|¡|¡|¡|¡ 311 -|(% style="width:107px" %)AND>|(% style="width:345px" %)Comparison of 16-bit data (>|¡|¡|¡|¡ 312 -|(% style="width:107px" %)AND<|(% style="width:345px" %)Comparison of 16-bit data (<|¡|¡|¡|¡ 313 -|(% style="width:107px" %)AND<>|(% style="width:345px" %)Comparison of 16-bit data (<>|¡|¡|¡|¡ 314 -|(% style="width:107px" %)AND<=|(% style="width:345px" %)Comparison of 16-bit data (<=)|¡|¡|¡|¡ 315 -|(% style="width:107px" %)AND>=|(% style="width:345px" %)Comparison of 16-bit data (>=)|¡|¡|¡|¡ 316 -|(% style="width:107px" %)OR=|(% style="width:345px" %)Comparison of 16-bit data (==)|¡|¡|¡|¡ 317 -|(% style="width:107px" %)ORD=|(% style="width:345px" %)Comparison of 32-bit data (==)|¡|¡|¡|¡ 318 -|(% style="width:107px" %)OR>|(% style="width:345px" %)Comparison of 16-bit data (>|¡|¡|¡|¡ 319 -|(% style="width:107px" %)OR<|(% style="width:345px" %)Comparison of 16-bit data (<|¡|¡|¡|¡ 320 -|(% style="width:107px" %)OR<>|(% style="width:345px" %)Comparison of 16-bit data (<>|¡|¡|¡|¡ 321 -|(% style="width:107px" %)OR<=|(% style="width:345px" %)Comparison of 16-bit data (<=)|¡|¡|¡|¡ 322 -|(% style="width:107px" %)OR>=|(% style="width:345px" %)Comparison of 16-bit data (>=)|¡|¡|¡|¡