1 | = **6.1.1 Basic program instruction list** = | ||
2 | |||
3 | (% class="table-bordered" %) | ||
4 | |**Instruction type**|**Instruction**|**Description**|((( | ||
5 | **LX3V(1S)** | ||
6 | )))|**LX3V (2N)**|**LX3VP**|**LX3VE** | ||
7 | |(% rowspan="25" %)[[Basic instructions>>path:/wiki/plc/view/2-User%20manual/6.Instruction/01.Basic%20instruction/]]|LD|Operation contact type NO (normally open)|¡|¡|¡|¡ | ||
8 | |LDI|Operation contact type NC (normally closed)|¡|¡|¡|¡ | ||
9 | |OUT|Final logical operation type coil drive|¡|¡|¡|¡ | ||
10 | |AND|Serial connection of NO(normally open)|¡|¡|¡|¡ | ||
11 | |ANI|Serial logical, operation contact type NC(normally closed) contacts|¡|¡|¡|¡ | ||
12 | |OR|Parallel, connection of NO (normally open) contacts|¡|¡|¡|¡ | ||
13 | |ORI|Parallel, connection of NC (normally closed) contacts|¡|¡|¡|¡ | ||
14 | |LDP|Initial logical, operation -Rising edge pulse|¡|¡|¡|¡ | ||
15 | |LDF|Initial logical, operation falling/trailing edge pulse|¡|¡|¡|¡ | ||
16 | |ANDP|Serial connection of Rising edge pulse|¡|¡|¡|¡ | ||
17 | |ANDF|Serial connection of falling/ trailing edge pulse|¡|¡|¡|¡ | ||
18 | |ORP|Parallel, connection of NO Rising edge pulse|¡|¡|¡|¡ | ||
19 | |ORF|Parallel connection of Falling/trailing edge pulse|¡|¡|¡|¡ | ||
20 | |ORB|Serial connection of multiple parallel circuits|¡|¡|¡|¡ | ||
21 | |ANB|Serial connection of multiple parallel circuits|¡|¡|¡|¡ | ||
22 | |MPS|Stores the current result of the internal PLC operations|¡|¡|¡|¡ | ||
23 | |MRD|Reads the current result of the internal PLC operations|¡|¡|¡|¡ | ||
24 | |MPP|Pops (recalls and removes) the currently stored result|¡|¡|¡|¡ | ||
25 | |MC|Denotes the start of a master control block|¡|¡|¡|¡ | ||
26 | |MCR|Denotes the end of a master control block|¡|¡|¡|¡ | ||
27 | |INV|Invert the current result of the internal PLC operations|¡|¡|¡|¡ | ||
28 | |PLS|Rising edge pulse|¡|¡|¡|¡ | ||
29 | |PLF|Falling / trailing edge pulse|¡|¡|¡|¡ | ||
30 | |SET|Sets a bit device permanently ON|¡|¡|¡|¡ | ||
31 | |RST|Resets a bit device permanently OFF|¡|¡|¡|¡ | ||
32 | |||
33 | = **6.1.2 Step ladder instructions list** = | ||
34 | |||
35 | (% class="table-bordered" %) | ||
36 | |**Instruction type**|**Instruction**|**Description**|((( | ||
37 | **LX3V** | ||
38 | |||
39 | **(1S)** | ||
40 | )))|**LX3V (2N)**|**LX3VP**|**LX3VE** | ||
41 | |(% rowspan="2" %)[[Step ladder instructions>>path:/wiki/plc/view/2-User%20manual/6.Instruction/17.Step%20control%20instructions/]]|STL|STL programming start instruction|¡|¡|¡|¡ | ||
42 | |RET|STL programming end instruction|¡|¡|¡|¡ | ||
43 | |||
44 | = **6.1.3 Program Flow instruction list** = | ||
45 | |||
46 | (% class="table-bordered" %) | ||
47 | |(% style="width:241px" %)**Instruction type**|(% style="width:129px" %)**Instruction**|(% style="width:306px" %)**Description**|((( | ||
48 | **LX3V** | ||
49 | |||
50 | **(1S)** | ||
51 | )))|**LX3V (2N)**|**LX3VP**|**LX3VE** | ||
52 | |(% rowspan="7" style="width:241px" %)[[Program flow instructions>>path:/wiki/plc/view/2-User%20manual/6.Instruction/02.Program%20flow/]]|(% style="width:129px" %)CJ|(% style="width:306px" %)Conditional jump|¡|¡|¡|¡ | ||
53 | |(% style="width:129px" %)CALL|(% style="width:306px" %)Call Subroutine|¡|¡|¡|¡ | ||
54 | |(% style="width:129px" %)EI|(% style="width:306px" %)Enable Interrupt|¡|¡|¡|¡ | ||
55 | |(% style="width:129px" %)DI|(% style="width:306px" %)Disable Interrupt|¡|¡|¡|¡ | ||
56 | |(% style="width:129px" %)WDT|(% style="width:306px" %)Watchdog Timer|¡|¡|¡|¡ | ||
57 | |(% style="width:129px" %)FOR|(% style="width:306px" %)Start of a For/Next Loop|¡|¡|¡|¡ | ||
58 | |(% style="width:129px" %)NEXT|(% style="width:306px" %)End a For/Next Loop|¡|¡|¡|¡ | ||
59 | |||
60 | = **6.1.4 Move and Compare instruction list** = | ||
61 | |||
62 | (% class="table-bordered" %) | ||
63 | |(% style="width:314px" %)**Instruction type**|(% style="width:146px" %)**Instruction**|**Description**|((( | ||
64 | **LX3V** | ||
65 | |||
66 | **(1S)** | ||
67 | )))|**LX3V (2N)**|**LX3VP**|**LX3VE** | ||
68 | |(% rowspan="10" style="width:314px" %)[[Move and Compare instructions>>path:/wiki/plc/view/2-User%20manual/6.Instruction/03.Move%20and%20campare/]]|(% style="width:146px" %)CMP|Compare |¡|¡|¡|¡ | ||
69 | |(% style="width:146px" %)ZCP|Zone compare|¡|¡|¡|¡ | ||
70 | |(% style="width:146px" %)MOV|Move |¡|¡|¡|¡ | ||
71 | |(% style="width:146px" %)SMOV|Shift move|-|¡|¡|¡ | ||
72 | |(% style="width:146px" %)CML|Compliment |-|¡|¡|¡ | ||
73 | |(% style="width:146px" %)BMOV|Block move|¡|¡|¡|¡ | ||
74 | |(% style="width:146px" %)FMOV|Fill move|-|¡|¡|¡ | ||
75 | |(% style="width:146px" %)XCH|Exchange |-|¡|¡|¡ | ||
76 | |(% style="width:146px" %)BCD|Binary coded decimal|¡|¡|¡|¡ | ||
77 | |(% style="width:146px" %)BIN|Binary |¡|¡|¡|¡ | ||
78 | |||
79 | = **6.1.5 Arithmetic and Logical Operations instruction list** = | ||
80 | |||
81 | (% class="table-bordered" %) | ||
82 | |(% style="width:358px" %)**Instruction type**|(% style="width:162px" %)**Instruction**|(% style="width:206px" %)**Description**|((( | ||
83 | **LX3V** | ||
84 | |||
85 | **(1S)** | ||
86 | )))|**LX3V (2N)**|**LX3VP**|**LX3VE** | ||
87 | |(% rowspan="10" style="width:358px" %)[[Arithmetic and Logical Operations instructions>>path:/wiki/plc/view/2-User%20manual/6.Instruction/06.Arithmetic%20and%20logical%20operations/]]|(% style="width:162px" %)ADD|(% style="width:206px" %)Addition |¡|¡|¡|¡ | ||
88 | |(% style="width:162px" %)SUB|(% style="width:206px" %)Subtraction |¡|¡|¡|¡ | ||
89 | |(% style="width:162px" %)MUL|(% style="width:206px" %)Multiplication |¡|¡|¡|¡ | ||
90 | |(% style="width:162px" %)DIV|(% style="width:206px" %)Division |¡|¡|¡|¡ | ||
91 | |(% style="width:162px" %)INC|(% style="width:206px" %)Increment|¡|¡|¡|¡ | ||
92 | |(% style="width:162px" %)DEC|(% style="width:206px" %)Decrement|¡|¡|¡|¡ | ||
93 | |(% style="width:162px" %)WAND|(% style="width:206px" %)Word AND|¡|¡|¡|¡ | ||
94 | |(% style="width:162px" %)WOR|(% style="width:206px" %)Word OR|¡|¡|¡|¡ | ||
95 | |(% style="width:162px" %)WXOR|(% style="width:206px" %)Word exclusive OR|¡|¡|¡|¡ | ||
96 | |(% style="width:162px" %)NEG|(% style="width:206px" %)Negation |-|¡|¡|¡ | ||
97 | |||
98 | = **6.1.6 Rotation and Shift instruction list** = | ||
99 | |||
100 | (% class="table-bordered" %) | ||
101 | |**Instruction type**|(% style="width:134px" %)**Instruction**|(% style="width:280px" %)**Description**|((( | ||
102 | **LX3V** | ||
103 | |||
104 | **(1S)** | ||
105 | )))|**LX3V (2N)**|**LX3VP**|**LX3VE** | ||
106 | |(% rowspan="10" %)[[Rotation and Shift instructions>>path:/wiki/plc/view/2-User%20manual/6.Instruction/08.Rotation%20and%20shift/]]|(% style="width:134px" %)ROR|(% style="width:280px" %)Rotation right|¡|¡|¡|¡ | ||
107 | |(% style="width:134px" %)ROL|(% style="width:280px" %)Rotation left|¡|¡|¡|¡ | ||
108 | |(% style="width:134px" %)RCR|(% style="width:280px" %)16-bit rotation right with carry|-|¡|¡|¡ | ||
109 | |(% style="width:134px" %)RCL|(% style="width:280px" %)16-bit rotation left with carry|-|¡|¡|¡ | ||
110 | |(% style="width:134px" %)SFTR|(% style="width:280px" %)(bit) shift right|¡|¡|¡|¡ | ||
111 | |(% style="width:134px" %)SFTL|(% style="width:280px" %)(bit) shift left|¡|¡|¡|¡ | ||
112 | |(% style="width:134px" %)WSFR|(% style="width:280px" %)word shift right|-|¡|¡|¡ | ||
113 | |(% style="width:134px" %)WSFL|(% style="width:280px" %)word shift left|-|¡|¡|¡ | ||
114 | |(% style="width:134px" %)SFWR|(% style="width:280px" %)shift register write|¡|¡|¡|¡ | ||
115 | |(% style="width:134px" %)SFRD|(% style="width:280px" %)shift register read|¡|¡|¡|¡ | ||
116 | |||
117 | = **6.1.7 Data operation instruction list** = | ||
118 | |||
119 | (% class="table-bordered" %) | ||
120 | |(% style="width:292px" %)**Instruction type**|(% style="width:135px" %)**Instruction**|(% style="width:266px" %)**Description**|((( | ||
121 | **LX3V** | ||
122 | |||
123 | **(1S)** | ||
124 | )))|**LX3V (2N)**|**LX3VP**|**LX3VE** | ||
125 | |(% rowspan="11" style="width:292px" %)[[Data operation instructions>>path:https://docs.we-con.com.cn/bin/view/PLC%20Editor/1%20User%20Manual/6.Instruction/04.Data%20operation/]]|(% style="width:135px" %)ZRST|(% style="width:266px" %)Zone reset|¡|¡|¡|¡ | ||
126 | |(% style="width:135px" %)DECO|(% style="width:266px" %)Decode |¡|¡|¡|¡ | ||
127 | |(% style="width:135px" %)ENCO|(% style="width:266px" %)Encode |¡|¡|¡|¡ | ||
128 | |(% style="width:135px" %)SUM|(% style="width:266px" %)The sum of active bits|-|¡|¡|¡ | ||
129 | |(% style="width:135px" %)BON|(% style="width:266px" %)Check specified bit status|-|¡|¡|¡ | ||
130 | |(% style="width:135px" %)MEAN|(% style="width:266px" %)Mean |-|¡|¡|¡ | ||
131 | |(% style="width:135px" %)ANS|(% style="width:266px" %)(timed) annunciator set|-|¡|¡|¡ | ||
132 | |(% style="width:135px" %)ANR|(% style="width:266px" %)Annunciator reset|-|¡|¡|¡ | ||
133 | |(% style="width:135px" %)SQR|(% style="width:266px" %)Square root|-|¡|¡|¡ | ||
134 | |(% style="width:135px" %)FLT|(% style="width:266px" %)Float |-|¡|¡|¡ | ||
135 | |(% style="width:135px" %)SWAP|(% style="width:266px" %)High and low bit conversion|-|¡|¡|¡ | ||
136 | |||
137 | = **6.1.8 High-speed Processing Instruction** = | ||
138 | |||
139 | (% class="table-bordered" %) | ||
140 | |(% style="width:290px" %)**Instruction type**|(% style="width:137px" %)**Instruction**|**Description**|((( | ||
141 | **LX3V** | ||
142 | |||
143 | **(1S)** | ||
144 | )))|**LX3V (2N)**|**LX3VP**|**LX3VE** | ||
145 | |(% rowspan="10" style="width:290px" %)[[High-speed Processing Instruction>>path:/wiki/plc/view/2-User%20manual/6.Instruction/07.High%20speed%20process/]]|(% style="width:137px" %)REF|Refresh|¡|¡|¡|¡ | ||
146 | |(% style="width:137px" %)REFF|Refresh and filter adjust|-|¡|¡|¡ | ||
147 | |(% style="width:137px" %)MTR|Input matrix|¡|¡|¡|¡ | ||
148 | |(% style="width:137px" %)DHSCR|High speed counter set|¡|¡|¡|¡ | ||
149 | |(% style="width:137px" %)DHSCS|High speed counter reset|¡|¡|¡|¡ | ||
150 | |(% style="width:137px" %)DHSZ|High speed counter zone compare|-|¡|¡|¡ | ||
151 | |(% style="width:137px" %)SPD|Speed detect|¡|¡|¡|¡ | ||
152 | |(% style="width:137px" %)PLSY|16-bit pulse Y output|¡|¡|¡|¡ | ||
153 | |(% style="width:137px" %)PWM|Pulse width modulation|¡|¡|¡|¡ | ||
154 | |(% style="width:137px" %)PLSR|Ramp pulse output|¡|¡|¡|¡ | ||
155 | |||
156 | = **6.1.9 ECAM instruction list** = | ||
157 | |||
158 | (% class="table-bordered" %) | ||
159 | |**Instruction type**|**Instruction**|**Description**|((( | ||
160 | **LX3V** | ||
161 | |||
162 | **(1S)** | ||
163 | )))|**LX3V (2N)**|**LX3VP**|**LX3VE** | ||
164 | |(% rowspan="3" %)[[ECAM instruction>>path:/wiki/plc/view/2-User%20manual/6.Instruction/10.ECAM/]]|DECAM|ECAM configuration|-|-|-|¡ | ||
165 | |DEGEAR|Electronic gear configuration|-|-|-|¡ | ||
166 | |ECAMTBX|Create E-CAM datasheet|-|-|-|¡ | ||
167 | |||
168 | = **6.1.10 External I/O Devices instruction list** = | ||
169 | |||
170 | (% class="table-bordered" %) | ||
171 | |**Instruction type**|**Instruction**|**Description**|((( | ||
172 | **LX3V** | ||
173 | |||
174 | **(1S)** | ||
175 | )))|**LX3V (2N)**|**LX3VP**|**LX3VE** | ||
176 | |(% rowspan="12" %)[[External I/O device instruction>>path:/wiki/plc/view/2-User%20manual/6.Instruction/09.External%20IO%20Devices/]]|TKY|Ten key input|-|¡|¡|¡ | ||
177 | |HKY|Hexadecimal input|-|¡|¡|¡ | ||
178 | |DSW|Digital switch (thumbwheel input)|¡|¡|¡|¡ | ||
179 | |SEGD|Seven segment decoder|-|¡|¡|¡ | ||
180 | |SEGL|Seven segment with latch|¡|¡|¡|¡ | ||
181 | |ARWS|Arrow switch|-|¡|¡|¡ | ||
182 | |ASC|ASCII code|-|¡|¡|¡ | ||
183 | |PR|“print” to a display|-|¡|¡|¡ | ||
184 | |FROM|Read from a special function block|¡|¡|¡|¡ | ||
185 | |TO|Write to a special function block|¡|¡|¡|¡ | ||
186 | |GRY|Converts binary integer to GRAY code|-|¡|¡|¡ | ||
187 | |GBIN|Converts GRAY CODE to binary|-|¡|¡|¡ | ||
188 | |||
189 | = **6.1.11 External Devices instruction list** = | ||
190 | |||
191 | (% class="table-bordered" %) | ||
192 | |**Instruction type**|**Instruction**|**Description**|((( | ||
193 | **LX3V** | ||
194 | |||
195 | **(1S)** | ||
196 | )))|**LX3V (2N)**|**LX3VP**|**LX3VE** | ||
197 | |(% rowspan="9" %)[[External devices instruction>>path:/wiki/plc/view/2-User%20manual/6.Instruction/13.External%20Device%20SER%20instruction/]]|RS|RS communications|¡|¡|¡|¡ | ||
198 | |RS2|RS2 communications|¡|¡|¡|¡ | ||
199 | |CPAVL|Serial port settings|¡|¡|¡|¡ | ||
200 | |CPAVL|Ethernet port settings|¡|¡|¡|¡ | ||
201 | |PRUN|Octal bit transmission|¡|¡|¡|¡ | ||
202 | |ASCI|hexadecimal to ASCII|¡|¡|¡|¡ | ||
203 | |HEX|ASCII to hexadecimal|¡|¡|¡|¡ | ||
204 | |CCD|check code|¡|¡|¡|¡ | ||
205 | |PID|PID control loop|¡|¡|¡|¡ | ||
206 | |||
207 | = **6.1.12 Floating Point instruction list** = | ||
208 | |||
209 | (% class="table-bordered" %) | ||
210 | |**Instruction type**|**Instruction**|**Description**|((( | ||
211 | **LX3V** | ||
212 | |||
213 | **(1S)** | ||
214 | )))|**LX3V (2N)**|**LX3VP**|**LX3VE** | ||
215 | |(% rowspan="22" %)[[Floating point instruction>>path:/wiki/plc/view/2-User%20manual/6.Instruction/14.Floating%20calculation/]]|DECMP|Binary floating point data compare|-|¡|¡|¡ | ||
216 | |DEZCP|Binary floating point zone compare|-|¡|¡|¡ | ||
217 | |DEBCD|Binary to BCD floating point data conversion|-|¡|¡|¡ | ||
218 | |DEBIN|BCD to Binary floating point data conversion|-|¡|¡|¡ | ||
219 | |DEADD|Binary floating point addition|-|¡|¡|¡ | ||
220 | |DESUB|Binary floating point subtraction|-|¡|¡|¡ | ||
221 | |DEMUL|Binary floating point multiplication|-|¡|¡|¡ | ||
222 | |DEDIV|Binary floating point division|-|¡|¡|¡ | ||
223 | |DESQR|Binary floating point square root|-|¡|¡|¡ | ||
224 | |INT|16-bit binary floating point to integer|-|¡|¡|¡ | ||
225 | |DSIN|Sin operation|-|¡|¡|¡ | ||
226 | |DCOS|Cosine operation|-|¡|¡|¡ | ||
227 | |DTAN|Tangent operation|-|¡|¡|¡ | ||
228 | |DASIN|Calculate radian value, according to the corresponding value of SIN|-|-|¡|¡ | ||
229 | |DSINH|Binary floating point operation of Hyperbolic Sine function SINH|-|-|¡|¡ | ||
230 | |DACOS|Calculate radian value, according to the corresponding value of COS|-|-|¡|¡ | ||
231 | |DCOSH|Binary floating point operation of Hyperbolic Cosine function COSH|-|-|¡|¡ | ||
232 | |DATAN|Calculate radian value, according to the corresponding value of TAN|-|-|¡|¡ | ||
233 | |DTANH|Binary floating point operation of Hyperbolic Tangent function TANH|-|-|¡|¡ | ||
234 | |DEXP|Perform exponent operation of binary floating-point number to base e (2.71828)|-|-|¡|¡ | ||
235 | |DLOG10|Perform common logarithm operation of binary floating-point number to base 10|-|-|¡|¡ | ||
236 | |DLOGE|Perform natural logarithm operation of binary floating-point number to base e (2.71828)|-|-|¡|¡ | ||
237 | |||
238 | = **6.1.13 Positioning Instruction list** = | ||
239 | |||
240 | (% class="table-bordered" %) | ||
241 | |**Instruction type**|**Instruction**|**Description**|((( | ||
242 | **LX3V** | ||
243 | |||
244 | **(1S)** | ||
245 | )))|**LX3V (2N)**|**LX3VP**|**LX3VE** | ||
246 | |(% rowspan="5" %)[[Positioning instruction>>path:/wiki/plc/view/2-User%20manual/6.Instruction/12.Positioning%20control/]]|DABS|Absolute current value read|¡|¡|¡|¡ | ||
247 | |ZRN|Setting of zero return speed|¡|¡|¡|¡ | ||
248 | |PLSV|Variable speed pulse output|¡|¡|¡|¡ | ||
249 | |DRVI|Relative position control|¡|¡|¡|¡ | ||
250 | |DRVA|Absolute position control|¡|¡|¡|¡ | ||
251 | |||
252 | **4.14 Real Time Clock Control** | ||
253 | |||
254 | (% class="table-bordered" %) | ||
255 | |**Instruction type**|**Instruction**|**Description**|((( | ||
256 | **LX3V** | ||
257 | |||
258 | **(1S)** | ||
259 | )))|**LX3V (2N)**|**LX3VP**|**LX3VE** | ||
260 | |(% rowspan="7" %)[[Real time clock control>>path:/wiki/plc/view/2-User%20manual/6.Instruction/05.Real%20time%20clock/]]|TCMP|time compare|¡|¡|¡|¡ | ||
261 | |TZCP|time zone compare|¡|¡|¡|¡ | ||
262 | |TADD|time addition|¡|¡|¡|¡ | ||
263 | |TSUB|time subtraction|¡|¡|¡|¡ | ||
264 | |TRD|read RTC data|¡|¡|¡|¡ | ||
265 | |TWR|set RTC data|¡|¡|¡|¡ | ||
266 | |HOUR|16-bit chronograph|¡|¡|¡|¡ | ||
267 | |||
268 | = **6.1.14 Handy Instructions list** = | ||
269 | |||
270 | (% class="table-bordered" %) | ||
271 | |**Instruction type**|**Instruction**|**Description**|((( | ||
272 | **LX3V(1S)** | ||
273 | )))|**LX3V (2N)**|**LX3VP**|**LX3VE** | ||
274 | |(% rowspan="10" %)[[Handy instruction>>path:/wiki/plc/view/2-User%20manual/6.Instruction/11.Handy%20instructions/]]|IST|initial state|¡|¡|¡|¡ | ||
275 | |SER|Search |-|¡|¡|¡ | ||
276 | |ABSD|Absolute drum|¡|¡|¡|¡ | ||
277 | |INCD|Incremental drum|¡|¡|¡|¡ | ||
278 | |TTMR|Teaching timer|-|¡|¡|¡ | ||
279 | |STMR|Special timer - definable|-|¡|¡|¡ | ||
280 | |ALT|Alternate state|¡|¡|¡|¡ | ||
281 | |RAMP|Ramp - variable value|¡|¡|¡|¡ | ||
282 | |ROTC|Rotary table control|-|¡|¡|¡ | ||
283 | |SORT|Sort data|-|¡|¡|¡ | ||
284 | |||
285 | = **6.1.15 Circular interpolation instruction list** = | ||
286 | |||
287 | (% class="table-bordered" %) | ||
288 | |**Instruction type**|**Instruction**|**Decryption**|**LX3V**|**LX3VP**|**LX3VE**|**LX3VM** | ||
289 | |(% rowspan="6" %)[[Circular interpolation instruction>>path:/wiki/plc/view/2-User%20manual/6.Instruction/15.Circular%20interpolation%20instruction/]]|G90G01|Absolute position line interpolation|-|-|-|¡ | ||
290 | |G91G01|Relative position line interpolation|-|-|-|¡ | ||
291 | |G90G02|Absolute position of the clockwise circular interpolation|-|-|-|¡ | ||
292 | |G91G02|Relative position clockwise circular interpolation|-|-|-|¡ | ||
293 | |G90G03|Absolute position anticlockwise circular interpolation|-|-|-|¡ | ||
294 | |G91G03|Relative position anticlockwise circular interpolation|-|-|-|¡ | ||
295 | |||
296 | = **6.1.16 Inline Comparisons Instruction list** = | ||
297 | |||
298 | (% class="table-bordered" %) | ||
299 | |(% style="width:260px" %)**Instruction type**|(% style="width:107px" %)**Instruction**|(% style="width:345px" %)**Description**|((( | ||
300 | **LX3V** | ||
301 | |||
302 | **(1S)** | ||
303 | )))|**LX3V (2N)**|**LX3VP**|**LX3VE** | ||
304 | |(% rowspan="19" style="width:260px" %)Inline comparisons instruction|(% style="width:107px" %)LD=|(% style="width:345px" %)Comparison of 16-bit data (==)|¡|¡|¡|¡ | ||
305 | |(% style="width:107px" %)LD>|(% style="width:345px" %)Comparison of 16-bit data (>|¡|¡|¡|¡ | ||
306 | |(% style="width:107px" %)LD<|(% style="width:345px" %)Comparison of 16-bit data (<|¡|¡|¡|¡ | ||
307 | |(% style="width:107px" %)LD<>|(% style="width:345px" %)Comparison of 16-bit data (<>|¡|¡|¡|¡ | ||
308 | |(% style="width:107px" %)LD<=|(% style="width:345px" %)Comparison of 16-bit data (<=)|¡|¡|¡|¡ | ||
309 | |(% style="width:107px" %)LD>=|(% style="width:345px" %)Comparison of 16-bit data (>=)|¡|¡|¡|¡ | ||
310 | |(% style="width:107px" %)AND=|(% style="width:345px" %)Comparison of 16-bit data (==)|¡|¡|¡|¡ | ||
311 | |(% style="width:107px" %)AND>|(% style="width:345px" %)Comparison of 16-bit data (>|¡|¡|¡|¡ | ||
312 | |(% style="width:107px" %)AND<|(% style="width:345px" %)Comparison of 16-bit data (<|¡|¡|¡|¡ | ||
313 | |(% style="width:107px" %)AND<>|(% style="width:345px" %)Comparison of 16-bit data (<>|¡|¡|¡|¡ | ||
314 | |(% style="width:107px" %)AND<=|(% style="width:345px" %)Comparison of 16-bit data (<=)|¡|¡|¡|¡ | ||
315 | |(% style="width:107px" %)AND>=|(% style="width:345px" %)Comparison of 16-bit data (>=)|¡|¡|¡|¡ | ||
316 | |(% style="width:107px" %)OR=|(% style="width:345px" %)Comparison of 16-bit data (==)|¡|¡|¡|¡ | ||
317 | |(% style="width:107px" %)ORD=|(% style="width:345px" %)Comparison of 32-bit data (==)|¡|¡|¡|¡ | ||
318 | |(% style="width:107px" %)OR>|(% style="width:345px" %)Comparison of 16-bit data (>|¡|¡|¡|¡ | ||
319 | |(% style="width:107px" %)OR<|(% style="width:345px" %)Comparison of 16-bit data (<|¡|¡|¡|¡ | ||
320 | |(% style="width:107px" %)OR<>|(% style="width:345px" %)Comparison of 16-bit data (<>|¡|¡|¡|¡ | ||
321 | |(% style="width:107px" %)OR<=|(% style="width:345px" %)Comparison of 16-bit data (<=)|¡|¡|¡|¡ | ||
322 | |(% style="width:107px" %)OR>=|(% style="width:345px" %)Comparison of 16-bit data (>=)|¡|¡|¡|¡ |