Changes for page 07 Communication
Last modified by Devin Chen on 2024/08/19 14:28
From version 12.1
edited by Devin Chen
on 2024/02/19 10:53
on 2024/02/19 10:53
Change comment:
There is no comment for this version
To version 17.1
edited by Theodore Xu
on 2024/08/08 10:10
on 2024/08/08 10:10
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. DevinChen1 +XWiki.AiXia - Content
-
... ... @@ -149,8 +149,6 @@ 149 149 150 150 **Read bit address from device** 151 151 152 -(When reading the bit address, the return value of 256 means that the coil is turned ON, and the return value of 0 means that the coil is turned OFF.) 153 - 154 154 (% style="text-align:center" %) 155 155 [[image:1641781999957-637.png||height="390" width="750" class="img-thumbnail"]] 156 156 ... ... @@ -196,7 +196,7 @@ 196 196 197 197 == **LX3VP COM2 N:N Connection** == 198 198 199 -PLC built-in N:N connection protocol provides a effective way to exchange data among multiple PLC (Max. 8 devices). Technically, it only requires the twisted pair RS485 cable to connect with each PLC COM2 (in parallel). 197 +PLC built-in N:N connection protocol provides an effective way to exchange data among multiple PLC (Max. 8 devices). Technically, it only requires the twisted pair RS485 cable to connect with each PLC COM2 (in parallel). 200 200 201 201 (% style="text-align:center" %) 202 202 [[image:9.Communication example_html_8c43baa1ae891689.jpg||height="142" width="500" class="img-thumbnail"]] ... ... @@ -263,7 +263,7 @@ 263 263 ))) 264 264 |M8191|Processing sending data 265 265 266 -== **Communications format :** ==264 +== **Communications format** == 267 267 268 268 (% border="1" %) 269 269 |=**Item**|=(% style="width: 115px;" %)**Parameters**|=(% style="width: 239px;" %)**b15(RS2)**|=**b14-b8**|=**b7**|=**b6**|=**b5**|=**b4**|=**b3**|=**b2**|=**b1**|=**b0** ... ... @@ -283,6 +283,20 @@ 283 283 |(% rowspan="2" %)**Data bit**|(% style="width:115px" %)7 bit|(% style="width:239px" %)-|-|-|-|-|-|-|-|0 284 284 |(% style="width:115px" %)8 bit|(% style="width:239px" %)-|-|-|-|-|-|-|-|1 285 285 284 +== **Communication error code (D8211~~D8218)** == 285 + 286 +|=(% style="width: 195px;" %)**Error code**|=(% style="width: 881px;" %)**Description** 287 +|(% style="width:195px" %)1|(% style="width:881px" %)The monitoring period has elapsed, and the slave station has not responded to requests from the master station yet. 288 +|(% style="width:195px" %)2|(% style="width:881px" %)The other slave stations have responded to requests sent by the master station. 289 +|(% style="width:195px" %)3|(% style="width:881px" %)The count values in the parameter data do not match those responded by the slave stations. 290 +|(% style="width:195px" %)4|(% style="width:881px" %)The response messages from the slave stations are incorrect. 291 +|(% style="width:195px" %)17|(% style="width:881px" %)The monitoring period has elapsed,the master station has not sent a request to the next slave station yet. 292 +|(% style="width:195px" %)20|(% style="width:881px" %)The messages from the master station are incorrect. 293 +|(% style="width:195px" %)33|(% style="width:881px" %)The slave station is unresponsive. 294 +|(% style="width:195px" %)34|(% style="width:881px" %)The other slave stations have responded to requests sent by the master station. 295 +|(% style="width:195px" %)35|(% style="width:881px" %)The count values in the parameter data do not match those responded by the slave stations. 296 +|(% style="width:195px" %)49|(% style="width:881px" %)The slave station received requests from the master station before receiving the parameters. 297 + 286 286 == **Program example** == 287 287 288 288 LX3VP COM2 port communication parameters: 9600, 1, 8, NONE. Register block mode: 3