Changes for page 07 Communication
Last modified by Devin Chen on 2024/08/19 14:28
From version 15.1
edited by Devin Chen
on 2024/03/22 09:52
on 2024/03/22 09:52
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PLC Editor.WebHome 1 +PLC Editor.LX3V programing manual.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. DevinChen1 +XWiki.Stone - Content
-
... ... @@ -1,4 +1,4 @@ 1 -= **PLC COM2 Modbus RTU** = 1 += **1 PLC COM2 Modbus RTU** = 2 2 3 3 == **Protocol Setting (D8126)** == 4 4 ... ... @@ -6,7 +6,6 @@ 6 6 |=WECON PLC Protocol|Using WECON PLC Protocol|01H 7 7 |=MODBUS RTU Master|PLC is slave device|02H 8 8 |=MODBUS ASCII Master|PLC is slave device|03H 9 -|=User-defined Protocol|Using User-defined Protocol|10H 10 10 |=MODBUS RTU Slave|PLC is master device|20H 11 11 |=MODBUS ASCII Slave|PLC is master device|30H 12 12 ... ... @@ -57,8 +57,8 @@ 57 57 |S0 ~~ S999|0xE000 ~~ 0xE3E7|57344 ~~ 58343 58 58 |T0 ~~ T256|0xF000 ~~ 0xF100|61440 ~~ 61696 59 59 |C0 ~~ C255|0xF400 ~~ 0xF4FF|62464 ~~ 62719 60 -|X0 ~~ X 377|0xF800 ~~ 0xF8FF|63488 ~~ 6374361 -|Y0 ~~ Y 377|0xFC00 ~~ 0xFCFF|64512 ~~ 6476759 +|X0 ~~ X255|0xF800 ~~ 0xF9FE|63488 ~~ 63998 60 +|Y0 ~~ Y255|0xFC00 ~~ 0xFDFE|64512 ~~ 65022 62 62 |(% colspan="3" %)** PLC Word Address** 63 63 |(% rowspan="2" %)PLC Address|(% colspan="2" %)MODBUS Address 64 64 |Hex|Decimal ... ... @@ -67,7 +67,7 @@ 67 67 |C0 ~~ C199|0xF400 ~~ 0xF4C7|62464 ~~ 62663 68 68 |C200 ~~ C255|0xF700 ~~ 0xF7FF|63232 ~~ 63487 69 69 70 -== **MODBUS function code introduction** ==69 +== **MODBUS function fode introduction** == 71 71 72 72 **Function code 0x01(01): read coil (bit address)** 73 73 ... ... @@ -190,13 +190,13 @@ 190 190 191 191 [[image:1641782240401-942.png||height="161" width="754"]] 192 192 193 -= (% style="color:inherit; font-family:inherit" %)**N:N network**(%%) = 192 += (% style="color:inherit; font-family:inherit" %)**2 N:N network**(%%) = 194 194 195 195 **LX3VP COM2 N:N Application** 196 196 197 197 == **LX3VP COM2 N:N Connection** == 198 198 199 -PLC built-in N:N connection protocol provides a neffective way to exchange data among multiple PLC (Max. 8 devices). Technically, it only requires the twisted pair RS485 cable to connect with each PLC COM2 (in parallel).198 +PLC built-in N:N connection protocol provides a effective way to exchange data among multiple PLC (Max. 8 devices). Technically, it only requires the twisted pair RS485 cable to connect with each PLC COM2 (in parallel). 200 200 201 201 (% style="text-align:center" %) 202 202 [[image:9.Communication example_html_8c43baa1ae891689.jpg||height="142" width="500" class="img-thumbnail"]] ... ... @@ -263,7 +263,7 @@ 263 263 ))) 264 264 |M8191|Processing sending data 265 265 266 -== **Communications format** == 265 +== **Communications format:** == 267 267 268 268 (% border="1" %) 269 269 |=**Item**|=(% style="width: 115px;" %)**Parameters**|=(% style="width: 239px;" %)**b15(RS2)**|=**b14-b8**|=**b7**|=**b6**|=**b5**|=**b4**|=**b3**|=**b2**|=**b1**|=**b0** ... ... @@ -283,20 +283,6 @@ 283 283 |(% rowspan="2" %)**Data bit**|(% style="width:115px" %)7 bit|(% style="width:239px" %)-|-|-|-|-|-|-|-|0 284 284 |(% style="width:115px" %)8 bit|(% style="width:239px" %)-|-|-|-|-|-|-|-|1 285 285 286 -== **Communication error code (D8211~~D8218)** == 287 - 288 -|=(% style="width: 195px;" %)**Error code**|=(% style="width: 881px;" %)**Description** 289 -|(% style="width:195px" %)1|(% style="width:881px" %)The monitoring period has elapsed, and the slave station has not respond to requests from the master station yet. 290 -|(% style="width:195px" %)2|(% style="width:881px" %)The other slave stations have responded to requests sent by the master station. 291 -|(% style="width:195px" %)3|(% style="width:881px" %)The count values in the parameter data do not match those responded by the slave stations. 292 -|(% style="width:195px" %)4|(% style="width:881px" %)The response messages from the slave stations are incorrect. 293 -|(% style="width:195px" %)17|(% style="width:881px" %)The monitoring period has elapsed,the master station has not sent a request to the next slave station yet. 294 -|(% style="width:195px" %)20|(% style="width:881px" %)The messages from the master station are incorrect. 295 -|(% style="width:195px" %)33|(% style="width:881px" %)The slave station is unresponsive. 296 -|(% style="width:195px" %)34|(% style="width:881px" %)The other slave stations have responded to requests sent by the master station. 297 -|(% style="width:195px" %)35|(% style="width:881px" %)The count values in the parameter data do not match those responded by the slave stations. 298 -|(% style="width:195px" %)49|(% style="width:881px" %)The slave station received requests from the master station before receiving the parameters. 299 - 300 300 == **Program example** == 301 301 302 302 LX3VP COM2 port communication parameters: 9600, 1, 8, NONE. Register block mode: 3 ... ... @@ -319,7 +319,7 @@ 319 319 * In LX3VP series PLC, only one kind of N:N configuration available. Second mode would be disabled when LX3VP built-in N:N protocol configured. 320 320 ))) 321 321 322 -= (% style="color:inherit; font-family:inherit" %)**RS485-BD and ETH-BD communiaction**(%%) = 307 += (% style="color:inherit; font-family:inherit" %)**3 RS485-BD and ETH-BD communiaction**(%%) = 323 323 324 324 Please kindly check the link as below. 325 325