Changes for page 07 Communication
Last modified by Devin Chen on 2024/08/19 14:28
From version 16.1
edited by Devin Chen
on 2024/03/22 10:03
on 2024/03/22 10:03
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PLC Editor.WebHome 1 +PLC Editor.1 User Manual.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. DevinChen1 +XWiki.Stone - Content
-
... ... @@ -6,7 +6,6 @@ 6 6 |=WECON PLC Protocol|Using WECON PLC Protocol|01H 7 7 |=MODBUS RTU Master|PLC is slave device|02H 8 8 |=MODBUS ASCII Master|PLC is slave device|03H 9 -|=User-defined Protocol|Using User-defined Protocol|10H 10 10 |=MODBUS RTU Slave|PLC is master device|20H 11 11 |=MODBUS ASCII Slave|PLC is master device|30H 12 12 ... ... @@ -57,9 +57,9 @@ 57 57 |S0 ~~ S999|0xE000 ~~ 0xE3E7|57344 ~~ 58343 58 58 |T0 ~~ T256|0xF000 ~~ 0xF100|61440 ~~ 61696 59 59 |C0 ~~ C255|0xF400 ~~ 0xF4FF|62464 ~~ 62719 60 -|X0 ~~ X 377|0xF800 ~~ 0xF8FF|63488 ~~ 6374361 -|Y0 ~~ Y 377|0xFC00 ~~ 0xFCFF|64512 ~~ 6476762 -|(% colspan="3" %)** PLC Word Address** 59 +|X0 ~~ X255|0xF800 ~~ 0xF9FE|63488 ~~ 63998 60 +|Y0 ~~ Y255|0xFC00 ~~ 0xFDFE|64512 ~~ 65022 61 +|(% colspan="3" %)** PLC Word Address** 63 63 |(% rowspan="2" %)PLC Address|(% colspan="2" %)MODBUS Address 64 64 |Hex|Decimal 65 65 |D0 ~~ D8255|0 ~~ 0x203F|0 ~~ 8255 ... ... @@ -67,7 +67,7 @@ 67 67 |C0 ~~ C199|0xF400 ~~ 0xF4C7|62464 ~~ 62663 68 68 |C200 ~~ C255|0xF700 ~~ 0xF7FF|63232 ~~ 63487 69 69 70 -== **MODBUS function code introduction** ==69 +== **MODBUS function fode introduction** == 71 71 72 72 **Function code 0x01(01): read coil (bit address)** 73 73 ... ... @@ -186,7 +186,7 @@ 186 186 [[image:1641782203514-616.png||height="230" width="746"]] 187 187 188 188 189 -**WECON PLC Protocol (COM2)** 188 +**(8) WECON PLC Protocol (COM2)** 190 190 191 191 [[image:1641782240401-942.png||height="161" width="754"]] 192 192 ... ... @@ -196,12 +196,12 @@ 196 196 197 197 == **LX3VP COM2 N:N Connection** == 198 198 199 -PLC built-in N:N connection protocol provides a neffective way to exchange data among multiple PLC (Max. 8 devices). Technically, it only requires the twisted pair RS485 cable to connect with each PLC COM2 (in parallel).198 +PLC built-in N:N connection protocol provides a effective way to exchange data among multiple PLC (Max. 8 devices). Technically, it only requires the twisted pair RS485 cable to connect with each PLC COM2 (in parallel). 200 200 201 201 (% style="text-align:center" %) 202 202 [[image:9.Communication example_html_8c43baa1ae891689.jpg||height="142" width="500" class="img-thumbnail"]] 203 203 204 -== **COM2 N:N Instructions ** == 203 +=== **COM2 N:N Instructions ** === 205 205 206 206 User should put data to specified register unit. Exchanging the data among PLCs, This function only requires putting data in preset register block, all the data in this register block would share with other PLCs. There are five modes for choice, according to data volume and communication speed. See the preset register block from table below. 207 207 ... ... @@ -234,7 +234,7 @@ 234 234 (% style="text-align:center" %) 235 235 [[image:9.Communication example_html_b805bca9e1166337.jpg||height="93" width="600" class="img-thumbnail"]] 236 236 237 -== ** Special devices in N: N network** ==236 +=== **The special devices in N: N network** === 238 238 239 239 (% border="1" %) 240 240 |=**Register**|=**Description** ... ... @@ -263,7 +263,7 @@ 263 263 ))) 264 264 |M8191|Processing sending data 265 265 266 -== **Communications format** == 265 +=== **Communications format:** === 267 267 268 268 (% border="1" %) 269 269 |=**Item**|=(% style="width: 115px;" %)**Parameters**|=(% style="width: 239px;" %)**b15(RS2)**|=**b14-b8**|=**b7**|=**b6**|=**b5**|=**b4**|=**b3**|=**b2**|=**b1**|=**b0** ... ... @@ -283,22 +283,8 @@ 283 283 |(% rowspan="2" %)**Data bit**|(% style="width:115px" %)7 bit|(% style="width:239px" %)-|-|-|-|-|-|-|-|0 284 284 |(% style="width:115px" %)8 bit|(% style="width:239px" %)-|-|-|-|-|-|-|-|1 285 285 286 -== ** Communication errorcode(D8211~~D8218)** ==285 +=== **Program example** === 287 287 288 -|=(% style="width: 195px;" %)**Error code**|=(% style="width: 881px;" %)**Description** 289 -|(% style="width:195px" %)1|(% style="width:881px" %)The monitoring period has elapsed, and the slave station has not responded to requests from the master station yet. 290 -|(% style="width:195px" %)2|(% style="width:881px" %)The other slave stations have responded to requests sent by the master station. 291 -|(% style="width:195px" %)3|(% style="width:881px" %)The count values in the parameter data do not match those responded by the slave stations. 292 -|(% style="width:195px" %)4|(% style="width:881px" %)The response messages from the slave stations are incorrect. 293 -|(% style="width:195px" %)17|(% style="width:881px" %)The monitoring period has elapsed,the master station has not sent a request to the next slave station yet. 294 -|(% style="width:195px" %)20|(% style="width:881px" %)The messages from the master station are incorrect. 295 -|(% style="width:195px" %)33|(% style="width:881px" %)The slave station is unresponsive. 296 -|(% style="width:195px" %)34|(% style="width:881px" %)The other slave stations have responded to requests sent by the master station. 297 -|(% style="width:195px" %)35|(% style="width:881px" %)The count values in the parameter data do not match those responded by the slave stations. 298 -|(% style="width:195px" %)49|(% style="width:881px" %)The slave station received requests from the master station before receiving the parameters. 299 - 300 -== **Program example** == 301 - 302 302 LX3VP COM2 port communication parameters: 9600, 1, 8, NONE. Register block mode: 3 303 303 304 304 **PLC as master** ... ... @@ -319,7 +319,7 @@ 319 319 * In LX3VP series PLC, only one kind of N:N configuration available. Second mode would be disabled when LX3VP built-in N:N protocol configured. 320 320 ))) 321 321 322 -= (% style="color:inherit; font-family:inherit" %)**RS485-BD and ETH-BD communiaction**(%%) = 307 +== (% style="color:inherit; font-family:inherit" %)**3 RS485-BD and ETH-BD communiaction**(%%) == 323 323 324 324 Please kindly check the link as below. 325 325