Changes for page 07 Communication
Last modified by Devin Chen on 2024/08/19 14:28
From version 17.1
edited by Theodore Xu
on 2024/08/08 10:10
on 2024/08/08 10:10
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PLC Editor.WebHome 1 +PLC Editor.1 User Manual.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. AiXia1 +XWiki.Stone - Content
-
... ... @@ -6,7 +6,6 @@ 6 6 |=WECON PLC Protocol|Using WECON PLC Protocol|01H 7 7 |=MODBUS RTU Master|PLC is slave device|02H 8 8 |=MODBUS ASCII Master|PLC is slave device|03H 9 -|=User-defined Protocol|Using User-defined Protocol|10H 10 10 |=MODBUS RTU Slave|PLC is master device|20H 11 11 |=MODBUS ASCII Slave|PLC is master device|30H 12 12 ... ... @@ -57,9 +57,9 @@ 57 57 |S0 ~~ S999|0xE000 ~~ 0xE3E7|57344 ~~ 58343 58 58 |T0 ~~ T256|0xF000 ~~ 0xF100|61440 ~~ 61696 59 59 |C0 ~~ C255|0xF400 ~~ 0xF4FF|62464 ~~ 62719 60 -|X0 ~~ X 377|0xF800 ~~ 0xF8FF|63488 ~~ 6374361 -|Y0 ~~ Y 377|0xFC00 ~~ 0xFCFF|64512 ~~ 6476762 -|(% colspan="3" %)** PLC Word Address** 59 +|X0 ~~ X255|0xF800 ~~ 0xF9FE|63488 ~~ 63998 60 +|Y0 ~~ Y255|0xFC00 ~~ 0xFDFE|64512 ~~ 65022 61 +|(% colspan="3" %)** PLC Word Address** 63 63 |(% rowspan="2" %)PLC Address|(% colspan="2" %)MODBUS Address 64 64 |Hex|Decimal 65 65 |D0 ~~ D8255|0 ~~ 0x203F|0 ~~ 8255 ... ... @@ -67,7 +67,7 @@ 67 67 |C0 ~~ C199|0xF400 ~~ 0xF4C7|62464 ~~ 62663 68 68 |C200 ~~ C255|0xF700 ~~ 0xF7FF|63232 ~~ 63487 69 69 70 -== **MODBUS function code introduction** ==69 +== **MODBUS function fode introduction** == 71 71 72 72 **Function code 0x01(01): read coil (bit address)** 73 73 ... ... @@ -149,6 +149,8 @@ 149 149 150 150 **Read bit address from device** 151 151 151 +(When reading the bit address, the return value of 256 means that the coil is turned ON, and the return value of 0 means that the coil is turned OFF.) 152 + 152 152 (% style="text-align:center" %) 153 153 [[image:1641781999957-637.png||height="390" width="750" class="img-thumbnail"]] 154 154 ... ... @@ -184,7 +184,7 @@ 184 184 [[image:1641782203514-616.png||height="230" width="746"]] 185 185 186 186 187 -**WECON PLC Protocol (COM2)** 188 +**(8) WECON PLC Protocol (COM2)** 188 188 189 189 [[image:1641782240401-942.png||height="161" width="754"]] 190 190 ... ... @@ -194,12 +194,12 @@ 194 194 195 195 == **LX3VP COM2 N:N Connection** == 196 196 197 -PLC built-in N:N connection protocol provides a neffective way to exchange data among multiple PLC (Max. 8 devices). Technically, it only requires the twisted pair RS485 cable to connect with each PLC COM2 (in parallel).198 +PLC built-in N:N connection protocol provides a effective way to exchange data among multiple PLC (Max. 8 devices). Technically, it only requires the twisted pair RS485 cable to connect with each PLC COM2 (in parallel). 198 198 199 199 (% style="text-align:center" %) 200 200 [[image:9.Communication example_html_8c43baa1ae891689.jpg||height="142" width="500" class="img-thumbnail"]] 201 201 202 -== **COM2 N:N Instructions ** == 203 +=== **COM2 N:N Instructions ** === 203 203 204 204 User should put data to specified register unit. Exchanging the data among PLCs, This function only requires putting data in preset register block, all the data in this register block would share with other PLCs. There are five modes for choice, according to data volume and communication speed. See the preset register block from table below. 205 205 ... ... @@ -232,7 +232,7 @@ 232 232 (% style="text-align:center" %) 233 233 [[image:9.Communication example_html_b805bca9e1166337.jpg||height="93" width="600" class="img-thumbnail"]] 234 234 235 -== ** Special devices in N: N network** ==236 +=== **The special devices in N: N network** === 236 236 237 237 (% border="1" %) 238 238 |=**Register**|=**Description** ... ... @@ -261,7 +261,7 @@ 261 261 ))) 262 262 |M8191|Processing sending data 263 263 264 -== **Communications format** == 265 +=== **Communications format:** === 265 265 266 266 (% border="1" %) 267 267 |=**Item**|=(% style="width: 115px;" %)**Parameters**|=(% style="width: 239px;" %)**b15(RS2)**|=**b14-b8**|=**b7**|=**b6**|=**b5**|=**b4**|=**b3**|=**b2**|=**b1**|=**b0** ... ... @@ -281,22 +281,8 @@ 281 281 |(% rowspan="2" %)**Data bit**|(% style="width:115px" %)7 bit|(% style="width:239px" %)-|-|-|-|-|-|-|-|0 282 282 |(% style="width:115px" %)8 bit|(% style="width:239px" %)-|-|-|-|-|-|-|-|1 283 283 284 -== ** Communication errorcode(D8211~~D8218)** ==285 +=== **Program example** === 285 285 286 -|=(% style="width: 195px;" %)**Error code**|=(% style="width: 881px;" %)**Description** 287 -|(% style="width:195px" %)1|(% style="width:881px" %)The monitoring period has elapsed, and the slave station has not responded to requests from the master station yet. 288 -|(% style="width:195px" %)2|(% style="width:881px" %)The other slave stations have responded to requests sent by the master station. 289 -|(% style="width:195px" %)3|(% style="width:881px" %)The count values in the parameter data do not match those responded by the slave stations. 290 -|(% style="width:195px" %)4|(% style="width:881px" %)The response messages from the slave stations are incorrect. 291 -|(% style="width:195px" %)17|(% style="width:881px" %)The monitoring period has elapsed,the master station has not sent a request to the next slave station yet. 292 -|(% style="width:195px" %)20|(% style="width:881px" %)The messages from the master station are incorrect. 293 -|(% style="width:195px" %)33|(% style="width:881px" %)The slave station is unresponsive. 294 -|(% style="width:195px" %)34|(% style="width:881px" %)The other slave stations have responded to requests sent by the master station. 295 -|(% style="width:195px" %)35|(% style="width:881px" %)The count values in the parameter data do not match those responded by the slave stations. 296 -|(% style="width:195px" %)49|(% style="width:881px" %)The slave station received requests from the master station before receiving the parameters. 297 - 298 -== **Program example** == 299 - 300 300 LX3VP COM2 port communication parameters: 9600, 1, 8, NONE. Register block mode: 3 301 301 302 302 **PLC as master** ... ... @@ -317,7 +317,7 @@ 317 317 * In LX3VP series PLC, only one kind of N:N configuration available. Second mode would be disabled when LX3VP built-in N:N protocol configured. 318 318 ))) 319 319 320 -= (% style="color:inherit; font-family:inherit" %)**RS485-BD and ETH-BD communiaction**(%%) = 307 +== (% style="color:inherit; font-family:inherit" %)**3 RS485-BD and ETH-BD communiaction**(%%) == 321 321 322 322 Please kindly check the link as below. 323 323