Changes for page 07 Communication

Last modified by Devin Chen on 2024/08/19 14:28

From version 17.1
edited by Theodore Xu
on 2024/08/08 10:10
Change comment: There is no comment for this version
To version 9.1
edited by Jim
on 2023/07/12 11:50
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.AiXia
1 +XWiki.Jim
Content
... ... @@ -1,4 +1,4 @@
1 -= **PLC COM2 Modbus RTU** =
1 += **1 PLC COM2 Modbus RTU** =
2 2  
3 3  == **Protocol Setting (D8126)** ==
4 4  
... ... @@ -6,7 +6,6 @@
6 6  |=WECON PLC Protocol|Using WECON PLC Protocol|01H
7 7  |=MODBUS RTU Master|PLC is slave device|02H
8 8  |=MODBUS ASCII Master|PLC is slave device|03H
9 -|=User-defined Protocol|Using User-defined Protocol|10H
10 10  |=MODBUS RTU Slave|PLC is master device|20H
11 11  |=MODBUS ASCII Slave|PLC is master device|30H
12 12  
... ... @@ -58,7 +58,7 @@
58 58  |T0 ~~ T256|0xF000 ~~ 0xF100|61440 ~~ 61696
59 59  |C0 ~~ C255|0xF400 ~~ 0xF4FF|62464 ~~ 62719
60 60  |X0 ~~ X377|0xF800 ~~ 0xF8FF|63488 ~~ 63743
61 -|Y0 ~~ Y377|0xFC00 ~~ 0xFCFF|64512 ~~ 64767
60 +|Y0 ~~ Y255|0xFC00 ~~ 0xFCFF|64512 ~~ 64767
62 62  |(% colspan="3" %)** PLC Word Address**
63 63  |(% rowspan="2" %)PLC Address|(% colspan="2" %)MODBUS Address
64 64  |Hex|Decimal
... ... @@ -149,6 +149,8 @@
149 149  
150 150  **Read bit address from device**
151 151  
151 +(When reading the bit address, the return value of 256 means that the coil is turned ON, and the return value of 0 means that the coil is turned OFF.)
152 +
152 152  (% style="text-align:center" %)
153 153  [[image:1641781999957-637.png||height="390" width="750" class="img-thumbnail"]]
154 154  
... ... @@ -188,13 +188,13 @@
188 188  
189 189  [[image:1641782240401-942.png||height="161" width="754"]]
190 190  
191 -= (% style="color:inherit; font-family:inherit" %)**N:N network**(%%) =
192 += (% style="color:inherit; font-family:inherit" %)**2 N:N network**(%%) =
192 192  
193 193  **LX3VP COM2 N:N Application**
194 194  
195 195  == **LX3VP COM2 N:N Connection** ==
196 196  
197 -PLC built-in N:N connection protocol provides an effective way to exchange data among multiple PLC (Max. 8 devices). Technically, it only requires the twisted pair RS485 cable to connect with each PLC COM2 (in parallel).
198 +PLC built-in N:N connection protocol provides a effective way to exchange data among multiple PLC (Max. 8 devices). Technically, it only requires the twisted pair RS485 cable to connect with each PLC COM2 (in parallel).
198 198  
199 199  (% style="text-align:center" %)
200 200  [[image:9.Communication example_html_8c43baa1ae891689.jpg||height="142" width="500" class="img-thumbnail"]]
... ... @@ -261,7 +261,7 @@
261 261  )))
262 262  |M8191|Processing sending data
263 263  
264 -== **Communications format** ==
265 +== **Communications format:** ==
265 265  
266 266  (% border="1" %)
267 267  |=**Item**|=(% style="width: 115px;" %)**Parameters**|=(% style="width: 239px;" %)**b15(RS2)**|=**b14-b8**|=**b7**|=**b6**|=**b5**|=**b4**|=**b3**|=**b2**|=**b1**|=**b0**
... ... @@ -281,20 +281,6 @@
281 281  |(% rowspan="2" %)**Data bit**|(% style="width:115px" %)7 bit|(% style="width:239px" %)-|-|-|-|-|-|-|-|0
282 282  |(% style="width:115px" %)8 bit|(% style="width:239px" %)-|-|-|-|-|-|-|-|1
283 283  
284 -== **Communication error code (D8211~~D8218)** ==
285 -
286 -|=(% style="width: 195px;" %)**Error code**|=(% style="width: 881px;" %)**Description**
287 -|(% style="width:195px" %)1|(% style="width:881px" %)The monitoring period has elapsed, and the slave station has not responded to requests from the master station yet.
288 -|(% style="width:195px" %)2|(% style="width:881px" %)The other slave stations have responded to requests sent by the master station.
289 -|(% style="width:195px" %)3|(% style="width:881px" %)The count values in the parameter data do not match those responded by the slave stations.
290 -|(% style="width:195px" %)4|(% style="width:881px" %)The response messages from the slave stations are incorrect.
291 -|(% style="width:195px" %)17|(% style="width:881px" %)The monitoring period has elapsed,the master station has not sent a request to the next slave station yet.
292 -|(% style="width:195px" %)20|(% style="width:881px" %)The messages from the master station are incorrect.
293 -|(% style="width:195px" %)33|(% style="width:881px" %)The slave station is unresponsive.
294 -|(% style="width:195px" %)34|(% style="width:881px" %)The other slave stations have responded to requests sent by the master station.
295 -|(% style="width:195px" %)35|(% style="width:881px" %)The count values in the parameter data do not match those responded by the slave stations.
296 -|(% style="width:195px" %)49|(% style="width:881px" %)The slave station received requests from the master station before receiving the parameters.
297 -
298 298  == **Program example** ==
299 299  
300 300  LX3VP COM2 port communication parameters: 9600, 1, 8, NONE. Register block mode: 3
... ... @@ -317,7 +317,7 @@
317 317  * In LX3VP series PLC, only one kind of N:N configuration available. Second mode would be disabled when LX3VP built-in N:N protocol configured.
318 318  )))
319 319  
320 -= (% style="color:inherit; font-family:inherit" %)**RS485-BD and ETH-BD communiaction**(%%) =
307 += (% style="color:inherit; font-family:inherit" %)**3 RS485-BD and ETH-BD communiaction**(%%) =
321 321  
322 322  Please kindly check the link as below.
323 323