Changes for page 07 Communication
Last modified by Devin Chen on 2024/08/19 14:28
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PLC Editor. 1 User Manual.WebHome1 +PLC Editor.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.Jim - Content
-
... ... @@ -1,4 +1,4 @@ 1 -= **PLC COM2 Modbus RTU** = 1 += **1 PLC COM2 Modbus RTU** = 2 2 3 3 == **Protocol Setting (D8126)** == 4 4 ... ... @@ -56,9 +56,9 @@ 56 56 |S0 ~~ S999|0xE000 ~~ 0xE3E7|57344 ~~ 58343 57 57 |T0 ~~ T256|0xF000 ~~ 0xF100|61440 ~~ 61696 58 58 |C0 ~~ C255|0xF400 ~~ 0xF4FF|62464 ~~ 62719 59 -|X0 ~~ X 255|0xF800 ~~ 0xF9FE|63488 ~~ 6399860 -|Y0 ~~ Y255|0xFC00 ~~ 0xF DFE|64512 ~~ 6502261 -|(% colspan="3" %)** 59 +|X0 ~~ X377|0xF800 ~~ 0xF8FF|63488 ~~ 63743 60 +|Y0 ~~ Y255|0xFC00 ~~ 0xFCFF|64512 ~~ 64767 61 +|(% colspan="3" %)** PLC Word Address** 62 62 |(% rowspan="2" %)PLC Address|(% colspan="2" %)MODBUS Address 63 63 |Hex|Decimal 64 64 |D0 ~~ D8255|0 ~~ 0x203F|0 ~~ 8255 ... ... @@ -66,7 +66,7 @@ 66 66 |C0 ~~ C199|0xF400 ~~ 0xF4C7|62464 ~~ 62663 67 67 |C200 ~~ C255|0xF700 ~~ 0xF7FF|63232 ~~ 63487 68 68 69 -== **MODBUS function fode introduction** ==69 +== **MODBUS function code introduction** == 70 70 71 71 **Function code 0x01(01): read coil (bit address)** 72 72 ... ... @@ -185,11 +185,11 @@ 185 185 [[image:1641782203514-616.png||height="230" width="746"]] 186 186 187 187 188 -** (8)WECON PLC Protocol (COM2)**188 +**WECON PLC Protocol (COM2)** 189 189 190 190 [[image:1641782240401-942.png||height="161" width="754"]] 191 191 192 -= (% style="color:inherit; font-family:inherit" %)**N:N network**(%%) = 192 += (% style="color:inherit; font-family:inherit" %)**2 N:N network**(%%) = 193 193 194 194 **LX3VP COM2 N:N Application** 195 195 ... ... @@ -200,7 +200,7 @@ 200 200 (% style="text-align:center" %) 201 201 [[image:9.Communication example_html_8c43baa1ae891689.jpg||height="142" width="500" class="img-thumbnail"]] 202 202 203 -== =**COM2 N:N Instructions ** ===203 +== **COM2 N:N Instructions ** == 204 204 205 205 User should put data to specified register unit. Exchanging the data among PLCs, This function only requires putting data in preset register block, all the data in this register block would share with other PLCs. There are five modes for choice, according to data volume and communication speed. See the preset register block from table below. 206 206 ... ... @@ -233,7 +233,7 @@ 233 233 (% style="text-align:center" %) 234 234 [[image:9.Communication example_html_b805bca9e1166337.jpg||height="93" width="600" class="img-thumbnail"]] 235 235 236 -== =**The special devices in N: N network** ===236 +== **Special devices in N: N network** == 237 237 238 238 (% border="1" %) 239 239 |=**Register**|=**Description** ... ... @@ -262,7 +262,7 @@ 262 262 ))) 263 263 |M8191|Processing sending data 264 264 265 -== =**Communications format:** ===265 +== **Communications format:** == 266 266 267 267 (% border="1" %) 268 268 |=**Item**|=(% style="width: 115px;" %)**Parameters**|=(% style="width: 239px;" %)**b15(RS2)**|=**b14-b8**|=**b7**|=**b6**|=**b5**|=**b4**|=**b3**|=**b2**|=**b1**|=**b0** ... ... @@ -282,7 +282,7 @@ 282 282 |(% rowspan="2" %)**Data bit**|(% style="width:115px" %)7 bit|(% style="width:239px" %)-|-|-|-|-|-|-|-|0 283 283 |(% style="width:115px" %)8 bit|(% style="width:239px" %)-|-|-|-|-|-|-|-|1 284 284 285 -== =**Program example** ===285 +== **Program example** == 286 286 287 287 LX3VP COM2 port communication parameters: 9600, 1, 8, NONE. Register block mode: 3 288 288 ... ... @@ -304,7 +304,7 @@ 304 304 * In LX3VP series PLC, only one kind of N:N configuration available. Second mode would be disabled when LX3VP built-in N:N protocol configured. 305 305 ))) 306 306 307 -= =(% style="color:inherit; font-family:inherit" %)**3 RS485-BD and ETH-BD communiaction**(%%) ==307 += (% style="color:inherit; font-family:inherit" %)**3 RS485-BD and ETH-BD communiaction**(%%) = 308 308 309 309 Please kindly check the link as below. 310 310