Changes for page 07 Communication

Last modified by Devin Chen on 2024/08/19 14:28

From version 8.1
edited by Stone Wu
on 2022/09/30 11:49
Change comment: There is no comment for this version
To version 12.1
edited by Devin Chen
on 2024/02/19 10:53
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.DevinChen
Content
... ... @@ -1,4 +1,4 @@
1 -= **1 PLC COM2 Modbus RTU** =
1 += **PLC COM2 Modbus RTU** =
2 2  
3 3  == **Protocol Setting (D8126)** ==
4 4  
... ... @@ -6,6 +6,7 @@
6 6  |=WECON PLC Protocol|Using WECON PLC Protocol|01H
7 7  |=MODBUS RTU Master|PLC is slave device|02H
8 8  |=MODBUS ASCII Master|PLC is slave device|03H
9 +|=User-defined Protocol|Using User-defined Protocol|10H
9 9  |=MODBUS RTU Slave|PLC is master device|20H
10 10  |=MODBUS ASCII Slave|PLC is master device|30H
11 11  
... ... @@ -56,8 +56,8 @@
56 56  |S0 ~~ S999|0xE000 ~~ 0xE3E7|57344 ~~ 58343
57 57  |T0 ~~ T256|0xF000 ~~ 0xF100|61440 ~~ 61696
58 58  |C0 ~~ C255|0xF400 ~~ 0xF4FF|62464 ~~ 62719
59 -|X0 ~~ X255|0xF800 ~~ 0xF9FE|63488 ~~ 63998
60 -|Y0 ~~ Y255|0xFC00 ~~ 0xFDFE|64512 ~~ 65022
60 +|X0 ~~ X377|0xF800 ~~ 0xF8FF|63488 ~~ 63743
61 +|Y0 ~~ Y377|0xFC00 ~~ 0xFCFF|64512 ~~ 64767
61 61  |(% colspan="3" %)** PLC Word Address**
62 62  |(% rowspan="2" %)PLC Address|(% colspan="2" %)MODBUS Address
63 63  |Hex|Decimal
... ... @@ -189,7 +189,7 @@
189 189  
190 190  [[image:1641782240401-942.png||height="161" width="754"]]
191 191  
192 -= (% style="color:inherit; font-family:inherit" %)**2 N:N network**(%%) =
193 += (% style="color:inherit; font-family:inherit" %)**N:N network**(%%) =
193 193  
194 194  **LX3VP COM2 N:N Application**
195 195  
... ... @@ -304,7 +304,7 @@
304 304  * In LX3VP series PLC, only one kind of N:N configuration available. Second mode would be disabled when LX3VP built-in N:N protocol configured.
305 305  )))
306 306  
307 -= (% style="color:inherit; font-family:inherit" %)**3 RS485-BD and ETH-BD communiaction**(%%) =
308 += (% style="color:inherit; font-family:inherit" %)**RS485-BD and ETH-BD communiaction**(%%) =
308 308  
309 309  Please kindly check the link as below.
310 310