Changes for page 01 Program execution
Last modified by Leo Wei on 2024/12/24 22:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -20,14 +20,11 @@ 20 20 21 21 == Installation == 22 22 23 -1. Please use it in the general specification environment described in the manual. 23 +* Please use it in the general specification environment described in the manual. 24 +** Do not use in the following places: places with dust, oily smoke, conductive dust, corrosive gas, flammable gas; places exposed to high temperature, condensation, wind and rain; places with vibration or impact. Electric shock, fire, and misoperation can also cause product damage. 25 +* When processing screw holes and wiring, do not let iron filings or wire ends fall into the ventilation window of the programmable controller. It may cause fire, malfunction, or misoperation. 26 +* Please insert the connecting cable and display module accurately into the specified sockets. Poor contact may cause misoperation. 24 24 25 -Do not use in the following places: places with dust, oily smoke, conductive dust, corrosive gas, flammable gas; places exposed to high temperature, condensation, wind and rain; places with vibration or impact. Electric shock, fire, and misoperation can also cause product damage. 26 - 27 - 2. When processing screw holes and wiring, do not let iron filings or wire ends fall into the ventilation window of the programmable controller. It may cause fire, malfunction, or misoperation. 28 - 29 - 3. Please insert the connecting cable and display module accurately into the specified sockets. Poor contact may cause misoperation. 30 - 31 31 (% class="box infomessage" %) 32 32 ((( 33 33 **✎Note:** ... ... @@ -75,14 +75,11 @@ 75 75 **Attention** 76 76 )))|Do not connect the empty terminal to the outside, otherwise the product will be damaged. 77 77 78 -Please connect the AC power supply to the dedicated terminal according to the content in the manual. 75 +* Please connect the AC power supply to the dedicated terminal according to the content in the manual. 76 +* If the AC power supply is connected to the DC input/output terminal or the DC power supply terminal, the programmable controller will be burnt out. 77 +* Please do not supply power to the 24+ terminal of the basic unit from the external power supply, and to the empty terminal . Do not wire from the outside, otherwise the product will be damaged. 78 +* Please ground the ground terminal of the basic unit according to the third method. But please do not share the ground with the strong current system. 79 79 80 -If the AC power supply is connected to the DC input/output terminal or the DC power supply terminal, the programmable controller will be burnt out. 81 - 82 -Please do not supply power to the 24+ terminal of the basic unit from the external power supply, and to the empty terminal . Do not wire from the outside, otherwise the product will be damaged. 83 - 84 -Please ground the ground terminal of the basic unit according to the third method. But please do not share the ground with the strong current system. 85 - 86 86 **Attached** 87 87 88 88 The programmable controller will continue to work if there is an instantaneous power failure of less than 10ms. ... ... @@ -136,11 +136,12 @@ 136 136 137 137 The initialization based on the status of the CPU module is as follows. 138 138 139 -**√**: execute. **×**: not execute 133 +* **√**: execute 134 +* **×**: not execute 140 140 141 141 (% class="table-bordered" %) 142 -|(% rowspan="2" %)**Processing item**|(% colspan="3" %)**Status of the CPU module** 143 -|**When the power is ON**|**STOP**|**When STOP RUN** 137 +|=(% rowspan="2" %)**Processing item**|=(% colspan="3" %)**Status of the CPU module** 138 +|=**When the power is ON**|=**STOP**|=**When STOP RUN** 144 144 |Initialization of input and output modules|√|×|× 145 145 |CPU parameter check|√|×|× 146 146 |Check of system parameters|√|×|× ... ... @@ -151,11 +151,11 @@ 151 151 152 152 Perform the following before starting program calculation. 153 153 154 -Update the actual input point of the PLC to the input relay X. 149 +* Update the actual input point of the PLC to the input relay X. 155 155 156 156 The following is executed after the END instruction is executed. 157 157 158 -Update the PLC output relay Y to the actual output point. 153 +* Update the PLC output relay Y to the actual output point. 159 159 160 160 **Key points** 161 161 ... ... @@ -187,10 +187,8 @@ 187 187 188 188 It is the first scan time of the CPU module in RUN. 189 189 190 -Process as the following way: 185 +Process as the following way: The value stored in SD134 (initial scan time (ms unit)) and SD135 (initial scan time (s unit)). 191 191 192 -The value stored in SD134 (initial scan time (ms unit)) and SD135 (initial scan time (s unit)). 193 - 194 194 = The flow of each procedure = 195 195 196 196 When the CPU module changes to the RUN state, the programs are executed in sequence according to the program execution type and execution sequence settings. ... ... @@ -202,10 +202,11 @@ 202 202 203 203 When the execution types of the programs are the same, they are executed in the order set in the execution order. 204 204 205 -**✎Note:** 198 +(% class="box infomessage" %) 199 +((( 200 +**✎Note:** When executing instructions that can be completed with multiple cycles (such as OUT T, RAMP, RS, etc.), they should be programmed in the scan program. If it is used in event execution type programs and mid-stage execution type programs, these instructions may not be executed in multiple scan cycles, causing actual results to be different from the ideal results. Therefore, unless events, interrupts and subroutines can be executed in each scan cycle. It is not recommended to use multi-cycle execution instructions in other situations. 201 +))) 206 206 207 -When executing instructions that can be completed with multiple cycles (such as OUT T, RAMP, RS, etc.), they should be programmed in the scan program. If it is used in event execution type programs and mid-stage execution type programs, these instructions may not be executed in multiple scan cycles, causing actual results to be different from the ideal results. Therefore, unless events, interrupts and subroutines can be executed in each scan cycle. It is not recommended to use multi-cycle execution instructions in other situations. 208 - 209 209 = Types of program execution = 210 210 211 211 == Scan execution program == ... ... @@ -224,11 +224,11 @@ 224 224 (% style="text-align:center" %) 225 225 [[image:1-5.png||height="372" width="300" class="img-thumbnail"]] 226 226 227 - *Scan the program name: the program name requires to match case, and the program name cannot use the same name228 - *The input of /%$@&=to`^<>?:{}[],;!*.~\~\'" is not supported. It cannot exceed 64 characters. The default name is MAINx.229 - *The number of scan programs that can be built is limited to 100.230 - *Each scan program has been END ended, but only the last END instruction is completed to calculate a scan cycle.231 - *The execution sequence runs from top to bottom in the order of creation.221 +1. Scan the program name: the program name requires to match case, and the program name cannot use the same name with device name (the device name does not match case). 222 +1. The input of /%$@&=~~`^<>?:{}[],;!*.~\~\'" is not supported. It cannot exceed 64 characters. The default name is MAINx. 223 +1. The number of scan programs that can be built is limited to 100. 224 +1. Each scan program has been END ended, but only the last END instruction is completed to calculate a scan cycle. 225 +1. The execution sequence runs from top to bottom in the order of creation. 232 232 233 233 (% style="text-align:center" %) 234 234 [[image:1-6.png||class="img-thumbnail"]] ... ... @@ -244,7 +244,7 @@ 244 244 245 245 The trigger of event execution type program is as follows. 246 246 247 -** (1)ON event of bit data (TRUE)**241 +**ON event of bit data (TRUE)** 248 248 249 249 * After the ON event is specified, if the contact that sets the trigger condition in the ON event is turned ON during the scan program, the ON event program will be executed in the scan program page*1 or before the END instruction is executed. 250 250 * The ON event program will only be executed once in a single scan cycle. ... ... @@ -260,13 +260,13 @@ 260 260 The devices that can be specified are as follows. 261 261 262 262 (% class="table-bordered" %) 263 -|(% colspan="2" %)**Project**|**Content** 257 +|=(% colspan="2" %)**Project**|=**Content** 264 264 |(% rowspan="2" %)Device *1|Bit Device|X, Y, M, SM 265 265 |Bit specification of word device|D.b 266 266 267 267 *1 The indexed device cannot be specified. 268 268 269 -** (2)TIME event**263 +**TIME event** 270 270 271 271 After the program is to RUN state and the specified time has elapsed, event is executed one time when it comes to the execution sequence of the first corresponding program. For the second and subsequent executions, the time is re-measured from the start of the last event execution type program. After the specified time has elapsed, the program is executed repeatedly when it comes to the execution sequence of the first corresponding program. In addition, in the next scan after the corresponding program is executed, the current value of the output (Y) and timer (T) used in the corresponding program can be cleared. It can be used for programs that do not need to respond in a fixed period of time. 272 272 ... ... @@ -291,7 +291,7 @@ 291 291 Event program name: 292 292 293 293 * The program name requires to match case, and the program name with the same name as the device cannot be used (the device name does not match case). 294 -* The program name does not support /%$@&= to`^<>?:{}[],;!*.~\~\'" character input.288 +* The program name does not support /%$@&=~~`^<>?:{}[],;!*.~\~\'" character input. 295 295 * The length of the program name cannot exceed 64 characters. The default name is EVENTx. 296 296 297 297 A maximum of 100 new event programs could be created. ... ... @@ -306,14 +306,14 @@ 306 306 (% style="text-align:center" %) 307 307 [[image:1-11.png||height="419" width="500" class="img-thumbnail"]] 308 308 309 -Configuration instructions: 303 +**Configuration instructions:** 310 310 311 - 1)Configuration interface305 + Configuration interface 312 312 313 313 (% style="text-align:center" %) 314 314 [[image:1-12.png||height="372" width="300" class="img-thumbnail"]] 315 315 316 - 2)Parameter content:310 +Parameter content: 317 317 318 318 (% class="table-bordered" %) 319 319 |(% colspan="2" %)**Project**|**Content**|**Setting range**|**Default** ... ... @@ -388,9 +388,9 @@ 388 388 389 389 **Interrupt trigger condition classification** 390 390 391 - 1.**External input (X) interrupt**385 +**External input (X) interrupt** 392 392 393 - **~ **1.Description of external input interrupt387 +Description of external input interrupt 394 394 395 395 1. The external input interrupt is triggered by the rising or falling edge of the fixed X point input. 396 396 1. Supports the rising and falling edge interrupts of a total of 8 input points of X0 to X7, and supports a total of 16 external input interrupts. ... ... @@ -398,15 +398,15 @@ 398 398 1. External input interrupt and high-speed counter cannot use the same X point. 399 399 1. You must use EI in the scan program to allow interrupts before the interrupt execution program will be executed. 400 400 401 - 2.External input interrupt steps.395 +External input interrupt steps. 402 402 403 -Project management→ Program→ Interrupt→ right click to create 397 +Project management→ Program→ Interrupt→ right click to create. 404 404 405 405 (% style="text-align:center" %) 406 406 [[image:1-16.png||class="img-thumbnail"]] 407 407 408 408 1. The interrupt program name requires to match case, and the program name with the same name as the device cannot be used (the device name does not match case), 409 -1. The interrupt program name does not support the input of /%$@&= to`^<>?:{}[],;!*.~\~\'" characters,403 +1. The interrupt program name does not support the input of /%$@&=~~`^<>?:{}[],;!*.~\~\'" characters, 410 410 1. The length of the interrupt program name cannot exceed 64 characters and cannot be typed. The default name is INTx. 411 411 412 412 Click Configure, and select external interrupt for execution type, as shown in the figure below (it can also be configured in "program parameters" in "parameters" in project management): ... ... @@ -526,33 +526,33 @@ 526 526 3. Description of triggering rules 527 527 528 528 (% class="table-bordered" %) 529 -|**Mode**|**Configuration**|**The current value**|**Action** 530 -|(% rowspan="2" %)High-speed compare interrupt (INT0)|(% rowspan="2" %)Comparison value: 10000|9999 → 10000|Execute all programs in interrupt INT0 531 -|10001 → 10000|Execute all programs in interrupt INT0 532 -|(% rowspan="2" %)High-speed comparison set (INT1)|(% rowspan="2" %)((( 523 +|(% style="width:135px" %)**Mode**|(% style="width:187px" %)**Configuration**|(% style="width:128px" %)**The current value**|(% style="width:324px" %)**Action** 524 +|(% rowspan="2" style="width:135px" %)High-speed compare interrupt (INT0)|(% rowspan="2" style="width:187px" %)Comparison value: 10000|(% style="width:128px" %)9999 → 10000|(% style="width:324px" %)Execute all programs in interrupt INT0 525 +|(% style="width:128px" %)10001 → 10000|(% style="width:324px" %)Execute all programs in interrupt INT0 526 +|(% rowspan="2" style="width:135px" %)High-speed comparison set (INT1)|(% rowspan="2" style="width:187px" %)((( 533 533 Comparison value: -50,000 534 534 535 535 Contact: Y10 536 -)))|-50001 → -50000|((( 530 +)))|(% style="width:128px" %)-50001 → -50000|(% style="width:324px" %)((( 537 537 Y10 is immediately set and mapped to the actual output (not affected by the scan period) 538 538 539 539 The program in INT1 will not be executed 540 540 ))) 541 -|-49999 → -50000|((( 535 +|(% style="width:128px" %)-49999 → -50000|(% style="width:324px" %)((( 542 542 Y10 is immediately set and mapped to the actual output (not affected by the scan period) 543 543 544 544 The program in INT1 will not be executed 545 545 ))) 546 -|(% rowspan="2" %)High-speed comparison reset (INT2)|(% rowspan="2" %)((( 540 +|(% rowspan="2" style="width:135px" %)High-speed comparison reset (INT2)|(% rowspan="2" style="width:187px" %)((( 547 547 Comparison value: 400000 548 548 549 549 Contact: Y10 550 -)))|399999 → 400000|((( 544 +)))|(% style="width:128px" %)399999 → 400000|(% style="width:324px" %)((( 551 551 Y10 is reset immediately and mapped to the actual output (not affected by the scan period) 552 552 553 553 The program in INT2 will not be executed 554 554 ))) 555 -|400001 → 400000|((( 549 +|(% style="width:128px" %)400001 → 400000|(% style="width:324px" %)((( 556 556 Y10 is reset immediately and mapped to the actual output (not affected by the scan period) 557 557 558 558 The program in INT2 will not be executed