Changes for page 01 Program execution
Last modified by Leo Wei on 2024/12/24 22:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -20,14 +20,11 @@ 20 20 21 21 == Installation == 22 22 23 -1. Please use it in the general specification environment described in the manual. 23 +* Please use it in the general specification environment described in the manual. 24 +** Do not use in the following places: places with dust, oily smoke, conductive dust, corrosive gas, flammable gas; places exposed to high temperature, condensation, wind and rain; places with vibration or impact. Electric shock, fire, and misoperation can also cause product damage. 25 +* When processing screw holes and wiring, do not let iron filings or wire ends fall into the ventilation window of the programmable controller. It may cause fire, malfunction, or misoperation. 26 +* Please insert the connecting cable and display module accurately into the specified sockets. Poor contact may cause misoperation. 24 24 25 -Do not use in the following places: places with dust, oily smoke, conductive dust, corrosive gas, flammable gas; places exposed to high temperature, condensation, wind and rain; places with vibration or impact. Electric shock, fire, and misoperation can also cause product damage. 26 - 27 - 2. When processing screw holes and wiring, do not let iron filings or wire ends fall into the ventilation window of the programmable controller. It may cause fire, malfunction, or misoperation. 28 - 29 - 3. Please insert the connecting cable and display module accurately into the specified sockets. Poor contact may cause misoperation. 30 - 31 31 (% class="box infomessage" %) 32 32 ((( 33 33 **✎Note:** ... ... @@ -75,14 +75,11 @@ 75 75 **Attention** 76 76 )))|Do not connect the empty terminal to the outside, otherwise the product will be damaged. 77 77 78 -Please connect the AC power supply to the dedicated terminal according to the content in the manual. 75 +* Please connect the AC power supply to the dedicated terminal according to the content in the manual. 76 +* If the AC power supply is connected to the DC input/output terminal or the DC power supply terminal, the programmable controller will be burnt out. 77 +* Please do not supply power to the 24+ terminal of the basic unit from the external power supply, and to the empty terminal . Do not wire from the outside, otherwise the product will be damaged. 78 +* Please ground the ground terminal of the basic unit according to the third method. But please do not share the ground with the strong current system. 79 79 80 -If the AC power supply is connected to the DC input/output terminal or the DC power supply terminal, the programmable controller will be burnt out. 81 - 82 -Please do not supply power to the 24+ terminal of the basic unit from the external power supply, and to the empty terminal . Do not wire from the outside, otherwise the product will be damaged. 83 - 84 -Please ground the ground terminal of the basic unit according to the third method. But please do not share the ground with the strong current system. 85 - 86 86 **Attached** 87 87 88 88 The programmable controller will continue to work if there is an instantaneous power failure of less than 10ms. ... ... @@ -140,8 +140,8 @@ 140 140 * **×**: not execute 141 141 142 142 (% class="table-bordered" %) 143 -|(% rowspan="2" %)**Processing item**|(% colspan="3" %)**Status of the CPU module** 144 -|**When the power is ON**|**STOP**|**When STOP RUN** 137 +|=(% rowspan="2" %)**Processing item**|=(% colspan="3" %)**Status of the CPU module** 138 +|=**When the power is ON**|=**STOP**|=**When STOP RUN** 145 145 |Initialization of input and output modules|√|×|× 146 146 |CPU parameter check|√|×|× 147 147 |Check of system parameters|√|×|× ... ... @@ -152,11 +152,11 @@ 152 152 153 153 Perform the following before starting program calculation. 154 154 155 -Update the actual input point of the PLC to the input relay X. 149 +* Update the actual input point of the PLC to the input relay X. 156 156 157 157 The following is executed after the END instruction is executed. 158 158 159 -Update the PLC output relay Y to the actual output point. 153 +* Update the PLC output relay Y to the actual output point. 160 160 161 161 **Key points** 162 162 ... ... @@ -188,10 +188,8 @@ 188 188 189 189 It is the first scan time of the CPU module in RUN. 190 190 191 -Process as the following way: 185 +Process as the following way: The value stored in SD134 (initial scan time (ms unit)) and SD135 (initial scan time (s unit)). 192 192 193 -The value stored in SD134 (initial scan time (ms unit)) and SD135 (initial scan time (s unit)). 194 - 195 195 = The flow of each procedure = 196 196 197 197 When the CPU module changes to the RUN state, the programs are executed in sequence according to the program execution type and execution sequence settings. ... ... @@ -203,10 +203,11 @@ 203 203 204 204 When the execution types of the programs are the same, they are executed in the order set in the execution order. 205 205 206 -**✎Note:** 198 +(% class="box infomessage" %) 199 +((( 200 +**✎Note:** When executing instructions that can be completed with multiple cycles (such as OUT T, RAMP, RS, etc.), they should be programmed in the scan program. If it is used in event execution type programs and mid-stage execution type programs, these instructions may not be executed in multiple scan cycles, causing actual results to be different from the ideal results. Therefore, unless events, interrupts and subroutines can be executed in each scan cycle. It is not recommended to use multi-cycle execution instructions in other situations. 201 +))) 207 207 208 -When executing instructions that can be completed with multiple cycles (such as OUT T, RAMP, RS, etc.), they should be programmed in the scan program. If it is used in event execution type programs and mid-stage execution type programs, these instructions may not be executed in multiple scan cycles, causing actual results to be different from the ideal results. Therefore, unless events, interrupts and subroutines can be executed in each scan cycle. It is not recommended to use multi-cycle execution instructions in other situations. 209 - 210 210 = Types of program execution = 211 211 212 212 == Scan execution program == ... ... @@ -225,11 +225,11 @@ 225 225 (% style="text-align:center" %) 226 226 [[image:1-5.png||height="372" width="300" class="img-thumbnail"]] 227 227 228 - *Scan the program name: the program name requires to match case, and the program name cannot use the same name229 - *The input of /%$@&=~~`^<>?:{}[],;!*.~\~\'" is not supported. It cannot exceed 64 characters. The default name is MAINx.230 - *The number of scan programs that can be built is limited to 100.231 - *Each scan program has been END ended, but only the last END instruction is completed to calculate a scan cycle.232 - *The execution sequence runs from top to bottom in the order of creation.221 +1. Scan the program name: the program name requires to match case, and the program name cannot use the same name with device name (the device name does not match case). 222 +1. The input of /%$@&=~~`^<>?:{}[],;!*.~\~\'" is not supported. It cannot exceed 64 characters. The default name is MAINx. 223 +1. The number of scan programs that can be built is limited to 100. 224 +1. Each scan program has been END ended, but only the last END instruction is completed to calculate a scan cycle. 225 +1. The execution sequence runs from top to bottom in the order of creation. 233 233 234 234 (% style="text-align:center" %) 235 235 [[image:1-6.png||class="img-thumbnail"]] ... ... @@ -245,7 +245,7 @@ 245 245 246 246 The trigger of event execution type program is as follows. 247 247 248 -** (1)ON event of bit data (TRUE)**241 +**ON event of bit data (TRUE)** 249 249 250 250 * After the ON event is specified, if the contact that sets the trigger condition in the ON event is turned ON during the scan program, the ON event program will be executed in the scan program page*1 or before the END instruction is executed. 251 251 * The ON event program will only be executed once in a single scan cycle. ... ... @@ -261,13 +261,13 @@ 261 261 The devices that can be specified are as follows. 262 262 263 263 (% class="table-bordered" %) 264 -|(% colspan="2" %)**Project**|**Content** 257 +|=(% colspan="2" %)**Project**|=**Content** 265 265 |(% rowspan="2" %)Device *1|Bit Device|X, Y, M, SM 266 266 |Bit specification of word device|D.b 267 267 268 268 *1 The indexed device cannot be specified. 269 269 270 -** (2)TIME event**263 +**TIME event** 271 271 272 272 After the program is to RUN state and the specified time has elapsed, event is executed one time when it comes to the execution sequence of the first corresponding program. For the second and subsequent executions, the time is re-measured from the start of the last event execution type program. After the specified time has elapsed, the program is executed repeatedly when it comes to the execution sequence of the first corresponding program. In addition, in the next scan after the corresponding program is executed, the current value of the output (Y) and timer (T) used in the corresponding program can be cleared. It can be used for programs that do not need to respond in a fixed period of time. 273 273 ... ... @@ -292,7 +292,7 @@ 292 292 Event program name: 293 293 294 294 * The program name requires to match case, and the program name with the same name as the device cannot be used (the device name does not match case). 295 -* The program name does not support /%$@&= to`^<>?:{}[],;!*.~\~\'" character input.288 +* The program name does not support /%$@&=~~`^<>?:{}[],;!*.~\~\'" character input. 296 296 * The length of the program name cannot exceed 64 characters. The default name is EVENTx. 297 297 298 298 A maximum of 100 new event programs could be created. ... ... @@ -307,14 +307,14 @@ 307 307 (% style="text-align:center" %) 308 308 [[image:1-11.png||height="419" width="500" class="img-thumbnail"]] 309 309 310 -Configuration instructions: 303 +**Configuration instructions:** 311 311 312 - 1)Configuration interface305 + Configuration interface 313 313 314 314 (% style="text-align:center" %) 315 315 [[image:1-12.png||height="372" width="300" class="img-thumbnail"]] 316 316 317 - 2)Parameter content:310 +Parameter content: 318 318 319 319 (% class="table-bordered" %) 320 320 |(% colspan="2" %)**Project**|**Content**|**Setting range**|**Default** ... ... @@ -389,9 +389,9 @@ 389 389 390 390 **Interrupt trigger condition classification** 391 391 392 - 1.**External input (X) interrupt**385 +**External input (X) interrupt** 393 393 394 - **~ **1.Description of external input interrupt387 +Description of external input interrupt 395 395 396 396 1. The external input interrupt is triggered by the rising or falling edge of the fixed X point input. 397 397 1. Supports the rising and falling edge interrupts of a total of 8 input points of X0 to X7, and supports a total of 16 external input interrupts. ... ... @@ -399,15 +399,15 @@ 399 399 1. External input interrupt and high-speed counter cannot use the same X point. 400 400 1. You must use EI in the scan program to allow interrupts before the interrupt execution program will be executed. 401 401 402 - 2.External input interrupt steps.395 +External input interrupt steps. 403 403 404 -Project management→ Program→ Interrupt→ right click to create 397 +Project management→ Program→ Interrupt→ right click to create. 405 405 406 406 (% style="text-align:center" %) 407 407 [[image:1-16.png||class="img-thumbnail"]] 408 408 409 409 1. The interrupt program name requires to match case, and the program name with the same name as the device cannot be used (the device name does not match case), 410 -1. The interrupt program name does not support the input of /%$@&= to`^<>?:{}[],;!*.~\~\'" characters,403 +1. The interrupt program name does not support the input of /%$@&=~~`^<>?:{}[],;!*.~\~\'" characters, 411 411 1. The length of the interrupt program name cannot exceed 64 characters and cannot be typed. The default name is INTx. 412 412 413 413 Click Configure, and select external interrupt for execution type, as shown in the figure below (it can also be configured in "program parameters" in "parameters" in project management): ... ... @@ -527,33 +527,33 @@ 527 527 3. Description of triggering rules 528 528 529 529 (% class="table-bordered" %) 530 -|**Mode**|**Configuration**|**The current value**|**Action** 531 -|(% rowspan="2" %)High-speed compare interrupt (INT0)|(% rowspan="2" %)Comparison value: 10000|9999 → 10000|Execute all programs in interrupt INT0 532 -|10001 → 10000|Execute all programs in interrupt INT0 533 -|(% rowspan="2" %)High-speed comparison set (INT1)|(% rowspan="2" %)((( 523 +|(% style="width:135px" %)**Mode**|(% style="width:187px" %)**Configuration**|(% style="width:128px" %)**The current value**|(% style="width:324px" %)**Action** 524 +|(% rowspan="2" style="width:135px" %)High-speed compare interrupt (INT0)|(% rowspan="2" style="width:187px" %)Comparison value: 10000|(% style="width:128px" %)9999 → 10000|(% style="width:324px" %)Execute all programs in interrupt INT0 525 +|(% style="width:128px" %)10001 → 10000|(% style="width:324px" %)Execute all programs in interrupt INT0 526 +|(% rowspan="2" style="width:135px" %)High-speed comparison set (INT1)|(% rowspan="2" style="width:187px" %)((( 534 534 Comparison value: -50,000 535 535 536 536 Contact: Y10 537 -)))|-50001 → -50000|((( 530 +)))|(% style="width:128px" %)-50001 → -50000|(% style="width:324px" %)((( 538 538 Y10 is immediately set and mapped to the actual output (not affected by the scan period) 539 539 540 540 The program in INT1 will not be executed 541 541 ))) 542 -|-49999 → -50000|((( 535 +|(% style="width:128px" %)-49999 → -50000|(% style="width:324px" %)((( 543 543 Y10 is immediately set and mapped to the actual output (not affected by the scan period) 544 544 545 545 The program in INT1 will not be executed 546 546 ))) 547 -|(% rowspan="2" %)High-speed comparison reset (INT2)|(% rowspan="2" %)((( 540 +|(% rowspan="2" style="width:135px" %)High-speed comparison reset (INT2)|(% rowspan="2" style="width:187px" %)((( 548 548 Comparison value: 400000 549 549 550 550 Contact: Y10 551 -)))|399999 → 400000|((( 544 +)))|(% style="width:128px" %)399999 → 400000|(% style="width:324px" %)((( 552 552 Y10 is reset immediately and mapped to the actual output (not affected by the scan period) 553 553 554 554 The program in INT2 will not be executed 555 555 ))) 556 -|400001 → 400000|((( 549 +|(% style="width:128px" %)400001 → 400000|(% style="width:324px" %)((( 557 557 Y10 is reset immediately and mapped to the actual output (not affected by the scan period) 558 558 559 559 The program in INT2 will not be executed