... ... @@ -382,9 +382,9 @@
382 382  
383 383  **Interrupt trigger condition classification**
384 384  
385 -1. **External input (X) interrupt**
385 +**External input (X) interrupt**
386 386  
387 -**~ **1. Description of external input interrupt
387 +Description of external input interrupt
388 388  
389 389  1. The external input interrupt is triggered by the rising or falling edge of the fixed X point input.
390 390  1. Supports the rising and falling edge interrupts of a total of 8 input points of X0 to X7, and supports a total of 16 external input interrupts.
... ... @@ -392,15 +392,15 @@
392 392  1. External input interrupt and high-speed counter cannot use the same X point.
393 393  1. You must use EI in the scan program to allow interrupts before the interrupt execution program will be executed.
394 394  
395 - 2. External input interrupt steps.
395 +External input interrupt steps.
396 396  
397 -Project management→ Program→ Interrupt→ right click to create
397 +Project management→ Program→ Interrupt→ right click to create.
398 398  
399 399  (% style="text-align:center" %)
400 400  [[image:1-16.png||class="img-thumbnail"]]
401 401  
402 402  1. The interrupt program name requires to match case, and the program name with the same name as the device cannot be used (the device name does not match case),
403 -1. The interrupt program name does not support the input of /%$@&=to`^<>?:{}[],;!*.~\~\'" characters,
403 +1. The interrupt program name does not support the input of /%$@&=~~`^<>?:{}[],;!*.~\~\'" characters,
404 404  1. The length of the interrupt program name cannot exceed 64 characters and cannot be typed. The default name is INTx.
405 405  
406 406  Click Configure, and select external interrupt for execution type, as shown in the figure below (it can also be configured in "program parameters" in "parameters" in project management):
... ... @@ -520,33 +520,33 @@
520 520   3. Description of triggering rules
521 521  
522 522  (% class="table-bordered" %)
523 -|**Mode**|**Configuration**|**The current value**|**Action**
524 -|(% rowspan="2" %)High-speed compare interrupt (INT0)|(% rowspan="2" %)Comparison value: 10000|9999 → 10000|Execute all programs in interrupt INT0
525 -|10001 → 10000|Execute all programs in interrupt INT0
526 -|(% rowspan="2" %)High-speed comparison set (INT1)|(% rowspan="2" %)(((
523 +|(% style="width:135px" %)**Mode**|(% style="width:187px" %)**Configuration**|(% style="width:128px" %)**The current value**|(% style="width:324px" %)**Action**
524 +|(% rowspan="2" style="width:135px" %)High-speed compare interrupt (INT0)|(% rowspan="2" style="width:187px" %)Comparison value: 10000|(% style="width:128px" %)9999 → 10000|(% style="width:324px" %)Execute all programs in interrupt INT0
525 +|(% style="width:128px" %)10001 → 10000|(% style="width:324px" %)Execute all programs in interrupt INT0
526 +|(% rowspan="2" style="width:135px" %)High-speed comparison set (INT1)|(% rowspan="2" style="width:187px" %)(((
527 527  Comparison value: -50,000
528 528  
529 529  Contact: Y10
530 -)))|-50001 → -50000|(((
530 +)))|(% style="width:128px" %)-50001 → -50000|(% style="width:324px" %)(((
531 531  Y10 is immediately set and mapped to the actual output (not affected by the scan period)
532 532  
533 533  The program in INT1 will not be executed
534 534  )))
535 -|-49999 → -50000|(((
535 +|(% style="width:128px" %)-49999 → -50000|(% style="width:324px" %)(((
536 536  Y10 is immediately set and mapped to the actual output (not affected by the scan period)
537 537  
538 538  The program in INT1 will not be executed
539 539  )))
540 -|(% rowspan="2" %)High-speed comparison reset (INT2)|(% rowspan="2" %)(((
540 +|(% rowspan="2" style="width:135px" %)High-speed comparison reset (INT2)|(% rowspan="2" style="width:187px" %)(((
541 541  Comparison value: 400000
542 542  
543 543  Contact: Y10
544 -)))|399999 → 400000|(((
544 +)))|(% style="width:128px" %)399999 → 400000|(% style="width:324px" %)(((
545 545  Y10 is reset immediately and mapped to the actual output (not affected by the scan period)
546 546  
547 547  The program in INT2 will not be executed
548 548  )))
549 -|400001 → 400000|(((
549 +|(% style="width:128px" %)400001 → 400000|(% style="width:324px" %)(((
550 550  Y10 is reset immediately and mapped to the actual output (not affected by the scan period)
551 551  
552 552  The program in INT2 will not be executed