Changes for page 01 Program execution
Last modified by Leo Wei on 2024/12/24 22:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -218,11 +218,11 @@ 218 218 (% style="text-align:center" %) 219 219 [[image:1-5.png||height="372" width="300" class="img-thumbnail"]] 220 220 221 - *Scan the program name: the program name requires to match case, and the program name cannot use the same name222 - *The input of /%$@&=~~`^<>?:{}[],;!*.~\~\'" is not supported. It cannot exceed 64 characters. The default name is MAINx.223 - *The number of scan programs that can be built is limited to 100.224 - *Each scan program has been END ended, but only the last END instruction is completed to calculate a scan cycle.225 - *The execution sequence runs from top to bottom in the order of creation.221 +1. Scan the program name: the program name requires to match case, and the program name cannot use the same name with device name (the device name does not match case). 222 +1. The input of /%$@&=~~`^<>?:{}[],;!*.~\~\'" is not supported. It cannot exceed 64 characters. The default name is MAINx. 223 +1. The number of scan programs that can be built is limited to 100. 224 +1. Each scan program has been END ended, but only the last END instruction is completed to calculate a scan cycle. 225 +1. The execution sequence runs from top to bottom in the order of creation. 226 226 227 227 (% style="text-align:center" %) 228 228 [[image:1-6.png||class="img-thumbnail"]] ... ... @@ -238,7 +238,7 @@ 238 238 239 239 The trigger of event execution type program is as follows. 240 240 241 -** (1)ON event of bit data (TRUE)**241 +**ON event of bit data (TRUE)** 242 242 243 243 * After the ON event is specified, if the contact that sets the trigger condition in the ON event is turned ON during the scan program, the ON event program will be executed in the scan program page*1 or before the END instruction is executed. 244 244 * The ON event program will only be executed once in a single scan cycle. ... ... @@ -254,13 +254,13 @@ 254 254 The devices that can be specified are as follows. 255 255 256 256 (% class="table-bordered" %) 257 -|(% colspan="2" %)**Project**|**Content** 257 +|=(% colspan="2" %)**Project**|=**Content** 258 258 |(% rowspan="2" %)Device *1|Bit Device|X, Y, M, SM 259 259 |Bit specification of word device|D.b 260 260 261 261 *1 The indexed device cannot be specified. 262 262 263 -** (2)TIME event**263 +**TIME event** 264 264 265 265 After the program is to RUN state and the specified time has elapsed, event is executed one time when it comes to the execution sequence of the first corresponding program. For the second and subsequent executions, the time is re-measured from the start of the last event execution type program. After the specified time has elapsed, the program is executed repeatedly when it comes to the execution sequence of the first corresponding program. In addition, in the next scan after the corresponding program is executed, the current value of the output (Y) and timer (T) used in the corresponding program can be cleared. It can be used for programs that do not need to respond in a fixed period of time. 266 266 ... ... @@ -300,26 +300,26 @@ 300 300 (% style="text-align:center" %) 301 301 [[image:1-11.png||height="419" width="500" class="img-thumbnail"]] 302 302 303 -Configuration instructions: 303 +**Configuration instructions:** 304 304 305 - 1)Configuration interface305 + Configuration interface 306 306 307 307 (% style="text-align:center" %) 308 308 [[image:1-12.png||height="372" width="300" class="img-thumbnail"]] 309 309 310 - 2)Parameter content:310 +Parameter content: 311 311 312 312 (% class="table-bordered" %) 313 -|(% colspan="2" %)**Project**|**Content**|**Setting range**|**Default** 314 -|(% colspan="2" %)Execution type|Select event type|Not set/ON event/TIME event|Not set 315 -|(% rowspan="2" %)ON event|Contact|The event type can be set when ON event is selected. Set the bit device as the trigger condition.|X/Y/M/SM/D.b| 316 -|Whether to clear|When the bit device of the trigger condition set by the ON event is turned OFF, whether to clear the current value of the output (Y) and timer (T) used in the execution program of the ON event in the next cycle.|((( 313 +|=(% colspan="2" %)**Project**|=(% style="width: 654px;" %)**Content**|=(% style="width: 190px;" %)**Setting range**|=**Default** 314 +|(% colspan="2" %)Execution type|(% style="width:654px" %)Select event type|(% style="width:190px" %)Not set/ON event/TIME event|Not set 315 +|(% rowspan="2" %)ON event|Contact|(% style="width:654px" %)The event type can be set when ON event is selected. Set the bit device as the trigger condition.|(% style="width:190px" %)X/Y/M/SM/D.b| 316 +|Whether to clear|(% style="width:654px" %)When the bit device of the trigger condition set by the ON event is turned OFF, whether to clear the current value of the output (Y) and timer (T) used in the execution program of the ON event in the next cycle.|(% style="width:190px" %)((( 317 317 True 318 318 319 319 False 320 320 )))|False 321 -|(% rowspan="2" %)TIME event|Time|Set how long to execute the event program once.|1 to 2147483647 (100us unit)| 322 -|Whether to clear|When the TIME event is executed, if the event is not executed in the next scan cycle, select whether to clear the output (Y) used in the TIME event execution program and the current value of the timer (T).|((( 321 +|(% rowspan="2" %)TIME event|Time|(% style="width:654px" %)Set how long to execute the event program once.|(% style="width:190px" %)1 to 2147483647 (100us unit)| 322 +|Whether to clear|(% style="width:654px" %)When the TIME event is executed, if the event is not executed in the next scan cycle, select whether to clear the output (Y) used in the TIME event execution program and the current value of the timer (T).|(% style="width:190px" %)((( 323 323 True 324 324 325 325 False ... ... @@ -333,78 +333,60 @@ 333 333 334 334 In the process of executing the scan program, the program that can interrupt the priority execution of the scan program is called an interrupt execution program. 335 335 336 - ~1.When an interrupt cause occurs, the interrupt program corresponding to the interrupt pointer number will be executed. However, the execution needs to be set to the interrupt enabled state by the EI instruction.336 +* When an interrupt cause occurs, the interrupt program corresponding to the interrupt pointer number will be executed. However, the execution needs to be set to the interrupt enabled state by the EI instruction. 337 337 338 338 (% style="text-align:center" %) 339 339 [[image:1652249587490-678.png||class="img-thumbnail"]] 340 340 341 341 342 - 2. An interrupt name corresponds to an interrupt program, and the interrupt name cannot be repeated. Each interrupt has its own trigger condition and execution program, and each interrupt program ends with END. 342 +* An interrupt name corresponds to an interrupt program, and the interrupt name cannot be repeated. Each interrupt has its own trigger condition and execution program, and each interrupt program ends with END. 343 +* Interrupt has the characteristic of interrupting the original execution program and executing the interrupt first, but it cannot interrupt the interrupt program being executed. 344 +* The interrupt program has the concept of priority. The smaller the priority value, the more priority the response. The priority setting range is 0 to 2. 343 343 344 - 3. Interrupthas thecharacteristicof interruptingtheoriginalexecution program andexecutingtheinterruptfirst,but itcannot interrupt theinterrupt programbeingexecuted.346 +**The actions when an interruption cause occurs are as follows:** 345 345 346 - 4. The interrupt program has the concept of priority. The smaller the priority value, the more priority the response. The priority setting range is 0 to 2. 348 +* Interrupt prohibition (DI) when an interruption cause occurs. 349 +** If the interrupt execution condition is triggered in a program that is forbidden by DI, the interrupt will not be executed. Even if the subsequent program uses the EI instruction to allow interruption, the previously shielded interrupt program will not be executed. Only the interrupt execution condition is triggered again. The interrupt program will be executed. 350 +* When multiple interrupt causes occur simultaneously in the interrupt enabled state. 351 +** The interrupt program with higher priority will be executed sequentially. In addition, when multiple interrupts with the same priority occur at the same time, the actions are executed in the order of interrupt priority. 352 +** If three interrupt programs I0, I10, I16 are created, the priority of I0 is 1, the priority of I10 is 0, and the priority of I16 is 1. The execution logic is shown in the figure below: I10 has the smallest priority and is executed first; I0 and I16 have the same priority and are executed in the order of program establishment. 347 347 348 -The actions when an interruption cause occurs are as follows: 349 - 350 -1. Interrupt prohibition (DI) when an interruption cause occurs. 351 - 352 -If the interrupt execution condition is triggered in a program that is forbidden by DI, the interrupt will not be executed. Even if the subsequent program uses the EI instruction to allow interruption, the previously shielded interrupt program will not be executed. Only the interrupt execution condition is triggered again. The interrupt program will be executed. 353 - 354 - 2.When multiple interrupt causes occur simultaneously in the interrupt enabled state. 355 - 356 -The interrupt program with higher priority will be executed sequentially. In addition, when multiple interrupts with the same priority occur at the same time, the actions are executed in the order of interrupt priority. 357 - 358 -If three interrupt programs I0, I10, I16 are created, the priority of I0 is 1, the priority of I10 is 0, and the priority of I16 is 1. The execution logic is shown in the figure below: I10 has the smallest priority and is executed first; I0 and I16 have the same priority and are executed in the order of program establishment. 359 - 360 360 (% style="text-align:center" %) 361 361 [[image:1652249553246-688.png||class="img-thumbnail"]] 362 362 363 - 3. When an interrupt occurs during the waiting time when performing constant scan. 357 +* When an interrupt occurs during the waiting time when performing constant scan. 358 +** Execute the interrupt program for this interrupt. 359 +* When other interrupts occur during the execution of the interrupt program. 360 +** In the interrupt program (including the specification when the interrupt occurs in the event execution program), when other interrupts occur, the original interrupt execution program will not be interrupted. After the original interrupt execution program is completed, the new interrupt program is executed. After the execution is completed Then return to the scanning procedure. 361 +* During the execution of the interrupt program, when an interrupt cause with a low priority or the same priority occurs. 362 +** The interruption cause that occurred is stored, and after the interrupt program in execution ends, the interrupt program corresponding to the stored interruption cause is executed. Even if the same interruption cause occurs multiple times, the interruption cause is stored only once. 364 364 365 -Execute the interrupt program for this interrupt. 366 - 367 - 4.When other interrupts occur during the execution of the interrupt program. 368 - 369 -In the interrupt program (including the specification when the interrupt occurs in the event execution program), when other interrupts occur, the original interrupt execution program will not be interrupted. After the original interrupt execution program is completed, the new interrupt program is executed. After the execution is completed Then return to the scanning procedure. 370 - 371 - 5. During the execution of the interrupt program, when an interrupt cause with a low priority or the same priority occurs. 372 - 373 -The interruption cause that occurred is stored, and after the interrupt program in execution ends, the interrupt program corresponding to the stored interruption cause is executed. Even if the same interruption cause occurs multiple times, the interruption cause is stored only once. 374 - 375 - 376 376 (% style="text-align:center" %) 377 377 [[image:1652249673420-476.png||class="img-thumbnail"]] 378 378 379 - 6. When the same interruption cause occurs during the execution of the interrupt program; 367 +* When the same interruption cause occurs during the execution of the interrupt program; 368 +** The interruption cause that occurred is stored, and after the interrupt program in execution ends, the interrupt program corresponding to the stored interruption cause is executed. Even if the same interruption cause occurs multiple times, the interruption cause is stored only once. 380 380 381 -The interruption cause that occurred is stored, and after the interrupt program in execution ends, the interrupt program corresponding to the stored interruption cause is executed. Even if the same interruption cause occurs multiple times, the interruption cause is stored only once. 382 - 383 383 **Interrupt trigger condition classification** 384 384 385 -**External input (X) interrupt** 372 +* **External input (X) interrupt** 373 +** Description of external input interrupt 374 +*** The external input interrupt is triggered by the rising or falling edge of the fixed X point input. 375 +*** Supports the rising and falling edge interrupts of a total of 8 input points of X0 to X7, and supports a total of 16 external input interrupts. 376 +*** The same interrupt trigger condition cannot create multiple interrupt programs. 377 +*** External input interrupt and high-speed counter cannot use the same X point. 378 +*** You must use EI in the scan program to allow interrupts before the interrupt execution program will be executed. 379 +* **External input interrupt steps.** 380 +** Project management→ Program→ Interrupt→ right click to create. 381 +** The interrupt program name requires to match case, and the program name with the same name as the device cannot be used (the device name does not match case), 382 +** The interrupt program name does not support the input of /%$@&=~~`^<>?:{}[],;!*.~\~\'" characters, 383 +** The length of the interrupt program name cannot exceed 64 characters and cannot be typed. The default name is INTx. 386 386 387 -Description of external input interrupt 388 - 389 -1. The external input interrupt is triggered by the rising or falling edge of the fixed X point input. 390 -1. Supports the rising and falling edge interrupts of a total of 8 input points of X0 to X7, and supports a total of 16 external input interrupts. 391 -1. The same interrupt trigger condition cannot create multiple interrupt programs. 392 -1. External input interrupt and high-speed counter cannot use the same X point. 393 -1. You must use EI in the scan program to allow interrupts before the interrupt execution program will be executed. 394 - 395 -External input interrupt steps. 396 - 397 -Project management→ Program→ Interrupt→ right click to create. 398 - 399 399 (% style="text-align:center" %) 400 400 [[image:1-16.png||class="img-thumbnail"]] 401 401 402 -1. The interrupt program name requires to match case, and the program name with the same name as the device cannot be used (the device name does not match case), 403 -1. The interrupt program name does not support the input of /%$@&=~~`^<>?:{}[],;!*.~\~\'" characters, 404 -1. The length of the interrupt program name cannot exceed 64 characters and cannot be typed. The default name is INTx. 388 +* Click Configure, and select external interrupt for execution type, as shown in the figure below (it can also be configured in "program parameters" in "parameters" in project management): 405 405 406 -Click Configure, and select external interrupt for execution type, as shown in the figure below (it can also be configured in "program parameters" in "parameters" in project management): 407 - 408 408 (% style="text-align:center" %) 409 409 [[image:1-17.png||class="img-thumbnail"]] 410 410 ... ... @@ -424,7 +424,7 @@ 424 424 Note: X rising edge interrupt and X falling edge interrupt use the same X filter, so after the filter setting is changed in the X rising edge configuration, the X falling edge will also change. If the filter time is set to 1000, you must ensure that the high level and low level of the input signal are maintained for more than 10 us before the interrupt can be triggered. 425 425 )))|0 to 1700|1 426 426 427 - 1.Write interrupt execution program409 +* Write interrupt execution program 428 428 429 429 (% style="text-align:center" %) 430 430 [[image:1-18.png||class="img-thumbnail"]] ... ... @@ -434,19 +434,19 @@ 434 434 (% style="text-align:center" %) 435 435 [[image:1652250056160-117.png||height="215" width="500" class="img-thumbnail"]] 436 436 437 -** ~ 2.Timer interrupt**419 +**Timer interrupt** 438 438 439 - 1.Timer interrupt description421 +Timer interrupt description 440 440 441 - 1.Timer interrupt is based on the set time, execute the interrupt program every this time, the minimum time interval can reach 100us.442 - 1.Up to 100 timer interrupt execution programs can be created.443 - 1.Each timer interrupt program is independent of each other and does not affect each other.444 - 1.Each timer interrupt program should be configured with priority. When triggered at the same time, it is executed in the order of priority, but when the priority is the same, it is executed in the order of the established program.445 - 1.The interrupt execution program is executed only after EI is used in the scanner to allow the interrupt423 +* Timer interrupt is based on the set time, execute the interrupt program every this time, the minimum time interval can reach 100us. 424 +* Up to 100 timer interrupt execution programs can be created. 425 +* Each timer interrupt program is independent of each other and does not affect each other. 426 +* Each timer interrupt program should be configured with priority. When triggered at the same time, it is executed in the order of priority, but when the priority is the same, it is executed in the order of the established program. 427 +* The interrupt execution program is executed only after EI is used in the scanner to allow the interrupt 446 446 447 - 2.Timer interrupt step429 +Timer interrupt step 448 448 449 -Project managementðProgramðInterruptðRight click to create. Enter the program name. The program name only supports the combination of English letters, numbers, and underscores, and must start with an English letter. The default is INTx. Click Configure and select Timer Interrupt as the execution type, as shown in the figure below (it can also be configured in "program parameters" in "parameters" in project management). 431 +* Project managementðProgramðInterruptðRight click to create. Enter the program name. The program name only supports the combination of English letters, numbers, and underscores, and must start with an English letter. The default is INTx. Click Configure and select Timer Interrupt as the execution type, as shown in the figure below (it can also be configured in "program parameters" in "parameters" in project management). 450 450 451 451 (% style="text-align:center" %) 452 452 [[image:1-20.png||class="img-thumbnail"]] ... ... @@ -457,34 +457,35 @@ 457 457 |(% rowspan="2" %)Timer interrupt|Time|Set the interval time for interrupt triggering|1 to 2147483647 (100us unit)| 458 458 |priority|When multiple interrupts arrive at the same time, the order of priority execution, the smallest value is executed first|0 to 2|0 459 459 460 - 1.Write interrupt execution program442 +Write interrupt execution program 461 461 462 462 (% style="text-align:center" %) 463 463 [[image:1-21.png||class="img-thumbnail"]] 464 464 465 -Double-click the newly created timer interrupt program in the project management to start writing the interrupt execution program. As shown in the figure above, a newly created timer interrupt program is INT0, and the trigger condition is configured to execute the interrupt program every 10ms. If the main program uses EI to enable interrupts, all instruction programs in INT0 will be executed every 10ms, namely D0 It will add 1 to 10ms. 447 +* Double-click the newly created timer interrupt program in the project management to start writing the interrupt execution program. As shown in the figure above, a newly created timer interrupt program is INT0, and the trigger condition is configured to execute the interrupt program every 10ms. If the main program uses EI to enable interrupts, all instruction programs in INT0 will be executed every 10ms, namely D0 It will add 1 to 10ms. 466 466 467 467 (% style="text-align:center" %) 468 468 [[image:1652250294005-455.png||class="img-thumbnail"]] 469 469 470 -** ~ 3.High-speed counter interrupt**452 +**High-speed counter interrupt** 471 471 472 - 1.Description of high-speed counter interrupt454 +Description of high-speed counter interrupt 473 473 474 - 1.The high-speed counter interrupt triggers an interrupt condition after the set value of the high-speed counter HSC0 to HSC7 provided by the PLC and executes the interrupt program.475 - 1.It can support up to 100 high-speed counter interrupt programs, but the number that can be supported by each channel does not need to be fixed.476 - 1.When using the high-speed counter interrupt, project must configure the high-speed counter and use the OUT HSC instruction to enable the corresponding counting channel to count before it can be used (see the high-speed counter description section for the specific configuration method).477 - 1.Each high-speed counter interrupt program should be configured with priority. When triggered at the same time, it will be executed in the order of priority. When the priority is the same, it will be executed in the order of channels HSC0-HSC7. When the channel is also the same, it is executed in order according to the creation promise.478 - 1.Project must use EI in the scan program to allow interrupts before the interrupt execution program will be executed.456 +* The high-speed counter interrupt triggers an interrupt condition after the set value of the high-speed counter HSC0 to HSC7 provided by the PLC and executes the interrupt program. 457 +* It can support up to 100 high-speed counter interrupt programs, but the number that can be supported by each channel does not need to be fixed. 458 +* When using the high-speed counter interrupt, project must configure the high-speed counter and use the OUT HSC instruction to enable the corresponding counting channel to count before it can be used (see the high-speed counter description section for the specific configuration method). 459 +* Each high-speed counter interrupt program should be configured with priority. When triggered at the same time, it will be executed in the order of priority. When the priority is the same, it will be executed in the order of channels HSC0-HSC7. When the channel is also the same, it is executed in order according to the creation promise. 460 +* Project must use EI in the scan program to allow interrupts before the interrupt execution program will be executed. 479 479 480 -**✎Note: **Both the HSC channel and the external input interrupt channel must use the PLC input point X. It should be noted that it 462 +(% class="box infomessage" %) 463 +((( 464 +**✎Note: **Both the HSC channel and the external input interrupt channel must use the PLC input point X. It should be noted that it cannot be reused during configuration. For details, please refer to the configuration chapter of the high-speed counter. 465 +))) 481 481 482 - cannot be reusedduringconfiguration. For details, pleasereferto the configurationchapterofthehigh-speed counter.467 +High-speed counter interrupt steps 483 483 484 - 1.high-speed counter interrupt step469 +* “Project management”ð“Programð“Interrupt”ðRight click to create. Enter the program name. The program name only supports the combination of English letters, numbers, and underscores, and must start with an English letter. The default is INTx. Click Configure, select high-speed interrupt for execution type, as shown in the figure below (it can also be configured in "program parameters" in "parameters" in project management). 485 485 486 -“Project management”ð“Programð“Interrupt”ðRight click to create. Enter the program name. The program name only supports the combination of English letters, numbers, and underscores, and must start with an English letter. The default is INTx. Click Configure, select high-speed interrupt for execution type, as shown in the figure below (it can also be configured in "program parameters" in "parameters" in project management). 487 - 488 488 (% style="text-align:center" %) 489 489 [[image:1-23.png||class="img-thumbnail"]] 490 490 ... ... @@ -517,7 +517,7 @@ 517 517 |Priority|When multiple interrupts arrive at the same time, the order of priority execution, the smallest value is executed first|0 to 2|0 518 518 |Contact|It is available when selecting high-speed comparison set and high-speed comparison reset. The contact is set or reset immediately after the trigger condition is reached.|Y/M/D.b| 519 519 520 - 3.Description of triggering rules503 + Description of triggering rules 521 521 522 522 (% class="table-bordered" %) 523 523 |(% style="width:135px" %)**Mode**|(% style="width:187px" %)**Configuration**|(% style="width:128px" %)**The current value**|(% style="width:324px" %)**Action** ... ... @@ -552,21 +552,22 @@ 552 552 The program in INT2 will not be executed 553 553 ))) 554 554 538 +(% class="box infomessage" %) 539 +((( 555 555 **✎Note: **Both HSC channel and external input interrupt channel need to use the INPUT point X, so it should be noted that it cannot be reused in configuration. For details, please refer to the configuration section of high-speed counter. 541 +))) 556 556 557 - 1.Write interrupt execution program543 +Write interrupt execution program 558 558 559 559 * New interrupt program 546 +** Create three new interrupt programs under the interrupt of project management, namely HSC0_20000, HSC0_30000, HSC0_40000. Configure the interrupt program in the "program parameters", as shown in the figure below. 560 560 561 -Create three new interrupt programs under the interrupt of project management, namely HSC0_20000, HSC0_30000, HSC0_40000. Configure the interrupt program in the "program parameters", as shown in the figure below. 562 - 563 563 (% style="text-align:center" %) 564 564 [[image:1-24.png||class="img-thumbnail"]] 565 565 566 566 * High-speed counter configuration 552 +** Configure HSC0 for use in the high-speed counter configuration. After selecting the working mode, click the "Check” button. After the correct configuration box pops up, click Enter. 567 567 568 -Configure HSC0 for use in the high-speed counter configuration. After selecting the working mode, click the "Check” button. After the correct configuration box pops up, click Enter. 569 - 570 570 (% style="text-align:center" %) 571 571 [[image:1-25.png||class="img-thumbnail"]] 572 572 ... ... @@ -576,131 +576,123 @@ 576 576 577 577 Program operation: 578 578 579 -Assuming that the High-speed counter channel 0 has been receiving pulses: 563 +* Assuming that the High-speed counter channel 0 has been receiving pulses: 564 +** When the count value of HSC0 accumulates from 0 to 20000, all procedures of HSC0_20000 are executed. 565 +** When the count value of HSC0 is accumulated from 20000 to 30000, all procedures of HSC0_30000 are executed. 566 +** When the count value of HSC0 is accumulated from 30000 to 40000, all procedures of HSC0_40000 are executed. 580 580 581 -When the count value of HSC0 accumulates from 0 to 20000, all procedures of HSC0_20000 are executed. 582 - 583 -When the count value of HSC0 is accumulated from 20000 to 30000, all procedures of HSC0_30000 are executed. 584 - 585 -When the count value of HSC0 is accumulated from 30000 to 40000, all procedures of HSC0_40000 are executed. 586 - 587 587 **Mask interrupt** 588 588 589 - **~ 1.Mask through application instructions**570 +Mask through application instructions 590 590 591 -The PLC interrupt is in the shielded state by default when it is powered on, and can only be used after the interrupt is allowed through the EI instruction. 572 +* The PLC interrupt is in the shielded state by default when it is powered on, and can only be used after the interrupt is allowed through the EI instruction. 573 +* The interrupt mask instruction DI masks all interrupts without parameters, and masks some priority interrupts with parameters (refer to the program flow instruction DI/EI for details). 592 592 593 - The interrupt maskinstruction DI masks all interrupts withoutparameters,andmasks some priority interrupts with parameters(referto the program flow instructionDI/EI for details).575 +Mask through special registers SM and SD 594 594 595 -**~ 2. Mask through special registers SM and SD** 596 - 597 -1.External input interrupt mask register 598 - 599 599 (% class="table-bordered" %) 600 -|(% colspan="4" %)**External input interrupt mask register** 601 -|**Special register number**|**Type of interrupt**|**Instruction**|**Defaults** 602 -|SM352|X0 rising edge interrupt|ON: Maskinterrupt OFF:Enableinterrupt|OFF603 -|SM353|X0 falling edge interrupt|ON: Maskinterrupt OFF:Enableinterrupt|OFF604 -|SM354|X1 rising edge interrupt|ON: Maskinterrupt OFF:Enableinterrupt|OFF605 -|SM355|X1 falling edge interrupt|ON: Maskinterrupt OFF:Enableinterrupt|OFF606 -|SM356|X2 rising edge interrupt|ON: Maskinterrupt OFF:Enableinterrupt|OFF607 -|SM357|X2 falling edge interrupt|ON: Maskinterrupt OFF:Enableinterrupt|OFF608 -|SM358|X3 rising edge interrupt|ON: Maskinterrupt OFF:Enableinterrupt|OFF609 -|SM359|X3 falling edge interrupt|ON: Maskinterrupt OFF:Enableinterrupt|OFF610 -|SM360|X4 rising edge interrupt|ON: Maskinterrupt OFF:Enableinterrupt|OFF611 -|SM361|X4 falling edge interrupt|ON: Maskinterrupt OFF:Enableinterrupt|OFF612 -|SM362|X5 rising edge interrupt|ON: Maskinterrupt OFF:Enableinterrupt|OFF613 -|SM363|X5 falling edge interrupt|ON: Maskinterrupt OFF:Enableinterrupt|OFF614 -|SM364|X6 rising edge interrupt|ON: Maskinterrupt OFF:Enableinterrupt|OFF615 -|SM365|X6 falling edge interrupt|ON: Maskinterrupt OFF:Enableinterrupt|OFF616 -|SM366|X7 rising edge interrupt|ON: Maskinterrupt OFF:Enableinterrupt|OFF617 -|SM367|X7 falling edge interrupt|ON: Maskinterrupt OFF:Enableinterrupt|OFF578 +|=(% colspan="4" %)**External input interrupt mask register** 579 +|=(% style="width: 266px;" %)**Special register number**|=(% style="width: 308px;" %)**Type of interrupt**|=(% style="width: 390px;" %)**Instruction**|=**Defaults** 580 +|(% style="width:266px" %)SM352|(% style="width:308px" %)X0 rising edge interrupt|(% style="width:390px" %)ON: shield interrupts; OFF: interrupt allowed|OFF 581 +|(% style="width:266px" %)SM353|(% style="width:308px" %)X0 falling edge interrupt|(% style="width:390px" %)ON: shield interrupts; OFF: interrupt allowed|OFF 582 +|(% style="width:266px" %)SM354|(% style="width:308px" %)X1 rising edge interrupt|(% style="width:390px" %)ON: shield interrupts; OFF: interrupt allowed|OFF 583 +|(% style="width:266px" %)SM355|(% style="width:308px" %)X1 falling edge interrupt|(% style="width:390px" %)ON: shield interrupts; OFF: interrupt allowed|OFF 584 +|(% style="width:266px" %)SM356|(% style="width:308px" %)X2 rising edge interrupt|(% style="width:390px" %)ON: shield interrupts; OFF: interrupt allowed|OFF 585 +|(% style="width:266px" %)SM357|(% style="width:308px" %)X2 falling edge interrupt|(% style="width:390px" %)ON: shield interrupts; OFF: interrupt allowed|OFF 586 +|(% style="width:266px" %)SM358|(% style="width:308px" %)X3 rising edge interrupt|(% style="width:390px" %)ON: shield interrupts; OFF: interrupt allowed|OFF 587 +|(% style="width:266px" %)SM359|(% style="width:308px" %)X3 falling edge interrupt|(% style="width:390px" %)ON: Shield interrupts; OFF: interrupt allowed|OFF 588 +|(% style="width:266px" %)SM360|(% style="width:308px" %)X4 rising edge interrupt|(% style="width:390px" %)ON: shield interrupts; OFF: interrupt allowed|OFF 589 +|(% style="width:266px" %)SM361|(% style="width:308px" %)X4 falling edge interrupt|(% style="width:390px" %)ON: shield interrupts; OFF: interrupt allowed|OFF 590 +|(% style="width:266px" %)SM362|(% style="width:308px" %)X5 rising edge interrupt|(% style="width:390px" %)ON: shield interrupts; OFF: interrupt allowed|OFF 591 +|(% style="width:266px" %)SM363|(% style="width:308px" %)X5 falling edge interrupt|(% style="width:390px" %)ON: Shield interrupts; OFF: interrupt allowed|OFF 592 +|(% style="width:266px" %)SM364|(% style="width:308px" %)X6 rising edge interrupt|(% style="width:390px" %)ON: shield interrupts; OFF: interrupt allowed|OFF 593 +|(% style="width:266px" %)SM365|(% style="width:308px" %)X6 falling edge interrupt|(% style="width:390px" %)ON: shield interrupts; OFF: interrupt allowed|OFF 594 +|(% style="width:266px" %)SM366|(% style="width:308px" %)X7 rising edge interrupt|(% style="width:390px" %)ON: shield interrupts; OFF: interrupt allowed|OFF 595 +|(% style="width:266px" %)SM367|(% style="width:308px" %)X7 falling edge interrupt|(% style="width:390px" %)ON: shield interrupts; OFF: interrupt allowed|OFF 618 618 619 -2. Timer interrupt mask register 620 - 621 621 (% class="table-bordered" %) 622 -|(% colspan="4" %)**Timer interrupt mask register** 623 -|**Special register number**|**Type of interrupt**|**Instruction**|**Default** 624 -|SD350|1st to 16th timer interrupt|((( 598 +|=(% colspan="4" %)**Timer interrupt mask register** 599 +|=(% style="width: 386px;" %)**Special register number**|=(% style="width: 247px;" %)**Type of interrupt**|=(% style="width: 332px;" %)**Instruction**|=(% style="width: 110px;" %)**Default** 600 +|(% style="width:386px" %)SD350|(% style="width:247px" %)1st to 16th timer interrupt|(% style="width:332px" %)((( 625 625 Each bit can control the mask of an interrupt. 626 626 627 -ON: Maskinterrupt OFF:Enableinterrupt628 -)))|0 629 -|SD351|17th to 32th timer interrupt|((( 603 +ON: shield interrupts; OFF: interrupt allowed 604 +)))|(% style="width:110px" %)0 605 +|(% style="width:386px" %)SD351|(% style="width:247px" %)17th to 32th timer interrupt|(% style="width:332px" %)((( 630 630 Each bit can control the mask of an interrupt. 631 631 632 -ON: Maskinterrupt OFF:Enableinterrupt633 -)))|0 634 -|SD352|33th to 48th timer interrupt|((( 608 +ON: shield interrupts; OFF: interrupt allowed 609 +)))|(% style="width:110px" %)0 610 +|(% style="width:386px" %)SD352|(% style="width:247px" %)33th to 48th timer interrupt|(% style="width:332px" %)((( 635 635 Each bit can control the mask of an interrupt. 636 636 637 -ON: Maskinterrupt OFF:Enableinterrupt638 -)))|0 639 -|SD353|49th to 64th timer interrupt|((( 613 +ON: shield interrupts; OFF: interrupt allowed 614 +)))|(% style="width:110px" %)0 615 +|(% style="width:386px" %)SD353|(% style="width:247px" %)49th to 64th timer interrupt|(% style="width:332px" %)((( 640 640 Each bit can control the mask of an interrupt. 641 641 642 -ON: Maskinterrupt OFF:Enableinterrupt643 -)))|0 644 -|SD354|65th to 80th timer interrupt|((( 618 +ON: shield interrupts; OFF: interrupt allowed 619 +)))|(% style="width:110px" %)0 620 +|(% style="width:386px" %)SD354|(% style="width:247px" %)65th to 80th timer interrupt|(% style="width:332px" %)((( 645 645 Each bit can control the mask of an interrupt. 646 646 647 -ON: Maskinterrupt OFF:Enableinterrupt648 -)))|0 649 -|SD355|81st to 96th timer interrupt|((( 623 +ON: shield interrupts; OFF: interrupt allowed 624 +)))|(% style="width:110px" %)0 625 +|(% style="width:386px" %)SD355|(% style="width:247px" %)81st to 96th timer interrupt|(% style="width:332px" %)((( 650 650 Each bit can control the mask of an interrupt. 651 651 652 -ON: Maskinterrupt OFF:Enableinterrupt653 -)))|0 654 -|SD356|97th to 100th timer interrupt|((( 628 +ON: shield interrupts; OFF: interrupt allowed 629 +)))|(% style="width:110px" %)0 630 +|(% style="width:386px" %)SD356|(% style="width:247px" %)97th to 100th timer interrupt|(% style="width:332px" %)((( 655 655 Each bit can control the mask of an interrupt. 656 656 657 -ON: Maskinterrupt OFF:Enableinterrupt658 -)))|0 633 +ON: shield interrupts; OFF: interrupt allowed 634 +)))|(% style="width:110px" %)0 659 659 660 660 1. high-speed counter interrupt mask register 661 661 662 662 (% class="table-bordered" %) 663 -|(% colspan="4" %)**High-speed counter interrupt mask register** 664 -|**Special register number**|**Type of interrupt**|**Instruction**|**Default** 665 -|SD382|1st to 16th high-speed counter interrupt|((( 639 +|=(% colspan="4" %)**High-speed counter interrupt mask register** 640 +|=(% style="width: 230px;" %)**Special register number**|=(% style="width: 348px;" %)**Type of interrupt**|=(% style="width: 387px;" %)**Instruction**|=(% style="width: 110px;" %)**Default** 641 +|(% style="width:230px" %)SD382|(% style="width:348px" %)1st to 16th high-speed counter interrupt|(% style="width:387px" %)((( 666 666 Each bit can control the mask of an interrupt. 667 667 668 -ON: Maskinterrupt OFF:Enableinterrupt669 -)))|0 670 -|SD383|17th to 32nd high-speed counter interrupt|((( 644 +ON: shield interrupts; OFF: interrupt allowed 645 +)))|(% style="width:110px" %)0 646 +|(% style="width:230px" %)SD383|(% style="width:348px" %)17th to 32nd high-speed counter interrupt|(% style="width:387px" %)((( 671 671 Each bit can control the mask of an interrupt. 672 672 673 -ON: Maskinterrupt OFF:Enableinterrupt674 -)))|0 675 -|SD384|33th to 48th high-speed counter interrupt|((( 649 +ON: shield interrupts; OFF: interrupt allowed 650 +)))|(% style="width:110px" %)0 651 +|(% style="width:230px" %)SD384|(% style="width:348px" %)33th to 48th high-speed counter interrupt|(% style="width:387px" %)((( 676 676 Each bit can control the mask of an interrupt. 677 677 678 -ON: Maskinterrupt OFF:Enableinterrupt679 -)))|0 680 -|SD385|49th to 64th high-speed counter interrupt|((( 654 +ON: shield interrupts; OFF: interrupt allowed 655 +)))|(% style="width:110px" %)0 656 +|(% style="width:230px" %)SD385|(% style="width:348px" %)49th to 64th high-speed counter interrupt|(% style="width:387px" %)((( 681 681 Each bit can control the mask of an interrupt. 682 682 683 -ON: Maskinterrupt OFF:Enableinterrupt684 -)))|0 685 -|SD386|65th to 80th high-speed counter interrupt|((( 659 +ON: shield interrupts; OFF: interrupt allowed 660 +)))|(% style="width:110px" %)0 661 +|(% style="width:230px" %)SD386|(% style="width:348px" %)65th to 80th high-speed counter interrupt|(% style="width:387px" %)((( 686 686 Each bit can control the mask of an interrupt. 687 687 688 -ON: Maskinterrupt OFF:Enableinterrupt689 -)))|0 690 -|SD387|81st to 96th high-speed counter interrupt|((( 664 +ON: shield interrupts; OFF: interrupt allowed 665 +)))|(% style="width:110px" %)0 666 +|(% style="width:230px" %)SD387|(% style="width:348px" %)81st to 96th high-speed counter interrupt|(% style="width:387px" %)((( 691 691 Each bit can control the mask of an interrupt. 692 692 693 -ON: Maskinterrupt OFF:Enableinterrupt694 -)))|0 695 -|SD388|97th to 100th high-speed counter interrupt|((( 669 +ON: shield interrupts; OFF: interrupt allowed 670 +)))|(% style="width:110px" %)0 671 +|(% style="width:230px" %)SD388|(% style="width:348px" %)97th to 100th high-speed counter interrupt|(% style="width:387px" %)((( 696 696 Each bit can control the mask of an interrupt. 697 697 698 -ON: Maskinterrupt OFF:Enableinterrupt699 -)))|0 674 +ON: shield interrupts; OFF: interrupt allowed 675 +)))|(% style="width:110px" %)0 700 700 701 701 == Subroutine == 702 702 703 -During the execution of the scan program, the executed program can be called by the CALL instruction. 679 +During the execution of the scan program, the executed program can be called by the CALL instruction. You can create up to 100 new subprograms. 704 704 705 705 A subroutine is to split a certain module in the main program for the main program to call, which is conducive to the modularization of the program. Such as other high-level language functions, but this function has no parameters and no return value. 706 706 ... ... @@ -707,7 +707,7 @@ 707 707 (% style="text-align:center" %) 708 708 [[image:1652250926997-587.png||class="img-thumbnail"]] 709 709 710 - 1.Instructions for calling subroutines686 +**Instructions for calling subroutines** 711 711 712 712 After a new subroutine is created, the content of the program is not executed. It is executed only when the CALL(P) instruction is used to call the subroutine in the scan, event, and interrupt programs, and the call is executed once. Three new subroutines SUB0, SUB1, SUB2 are created as shown in the figure below. In the main program MAIN, the subprogram can be called by using the CALL(P) subprogram program name. 713 713 ... ... @@ -716,87 +716,87 @@ 716 716 (% style="text-align:center" %) 717 717 [[image:1-28.png||class="img-thumbnail"]] 718 718 719 -**~ 1.✎Note:** 695 +(% class="box infomessage" %) 696 +((( 697 +**✎Note:** 720 720 721 721 1. When using the timer (OUT T), note that the output will not be reset when the subroutine is not called, and a specific subroutine register must be used. 722 722 1. It is not allowed to call recursively between subprograms, that is, call SUB1 in SUB0, and then call SUB0 in SUB1. This is not allowed. 723 723 1. The subroutine can be nested up to 32 levels. If the level exceeds 32 levels, a serious error will be reported and the Circuit program operation will be forcibly stopped. 724 724 1. Unlike the LX3V series mainframe, the subroutine in the LX5V series mainframe ends with the END instruction instead of SRET. 703 +))) 725 725 726 726 == Positioning instructions == 727 727 728 - ~1. Event 707 +(% class="wikigeneratedid" %) 708 +**Event** 729 729 730 - 1.ON event 710 +(% class="wikigeneratedid" %) 711 +ON event 731 731 732 -If the high-speed pulse instruction is turned on during the ON event, the high-speed pulse instruction will be sent as normal. If the ON contact of the trigger event in the scan period is turned OFF during the pulse sending, select whether to continue sending the pulse or stop the pulse according to the unscanned processing flag bit. 713 +* If the high-speed pulse instruction is turned on during the ON event, the high-speed pulse instruction will be sent as normal. If the ON contact of the trigger event in the scan period is turned OFF during the pulse sending, select whether to continue sending the pulse or stop the pulse according to the unscanned processing flag bit. 733 733 734 734 (% class="table-bordered" %) 735 -|**Output shaft**|Y0|Y1|Y2|Y3|Y4|Y5|Y6|Y7 736 -|**Not scanned flag bit**|SM899|SM959|SM1019|SM1079|SM1139|SM1199|SM1259|SM1319 716 +|=(% scope="row" %)**Output shaft**|Y0|Y1|Y2|Y3|Y4|Y5|Y6|Y7 717 +|=**Not scanned flag bit**|SM899|SM959|SM1019|SM1079|SM1139|SM1199|SM1259|SM1319 737 737 738 -When the flag bit is 0 (continue to send pulse), if the instruction is not scanned in the current scan cycle, continue to send pulses until it stops. At this time, it should be noted that if the trigger event OFF contact turns ON after the pulse is sent, the pulse will be sent again. 719 +* When the flag bit is 0 (continue to send pulse), if the instruction is not scanned in the current scan cycle, continue to send pulses until it stops. At this time, it should be noted that if the trigger event OFF contact turns ON after the pulse is sent, the pulse will be sent again. 720 +* When the flag bit is 1 (stop sending pulses), if the trigger event ON contact turns OFF in a certain scan period, it will decelerate and stop. 739 739 740 - Whentheflag bit is 1 (stop sending pulses), if the trigger eventON contact turns OFF in a certain scan period, it will decelerate and stop.722 + TIME event 741 741 742 - 2.TIME event724 +* If the high-speed pulse instruction is turned on in the TIME event, the high-speed pulse instruction will be sent as normal. If the instruction is not scanned in a certain scan period during the pulse transmission, select whether to continue sending the pulse or stop the pulse according to the unscanned processing flag bit. 743 743 744 -If the high-speed pulse instruction is turned on in the TIME event, the high-speed pulse instruction will be sent as normal. If the instruction is not scanned in a certain scan period during the pulse transmission, select whether to continue sending the pulse or stop the pulse according to the unscanned processing flag bit. 745 - 746 746 (% class="table-bordered" %) 747 -|**Output shaft**|Y0|Y1|Y2|Y3|Y4|Y5|Y6|Y7 748 -|**Not scanned flag bit**|SM899|SM959|SM1019|SM1079|SM1139|SM1199|SM1259|SM1319 727 +|=(% scope="row" %)**Output shaft**|Y0|Y1|Y2|Y3|Y4|Y5|Y6|Y7 728 +|=**Not scanned flag bit**|SM899|SM959|SM1019|SM1079|SM1139|SM1199|SM1259|SM1319 749 749 750 -When the flag bit is 0 (continue to send pulse), if the instruction is not scanned in the current scan cycle, the pulse will continue to be sent until it stops. In the TIME event, it is impossible to ensure that the instruction is scanned in every scan cycle, so you should avoid using high-speed pulse instructions in the TIME time, otherwise the pulse will be sent again after the pulse is sent. 730 +* When the flag bit is 0 (continue to send pulse), if the instruction is not scanned in the current scan cycle, the pulse will continue to be sent until it stops. In the TIME event, it is impossible to ensure that the instruction is scanned in every scan cycle, so you should avoid using high-speed pulse instructions in the TIME time, otherwise the pulse will be sent again after the pulse is sent. 731 +* When the flag bit is 1 (stop sending pulses), if the instruction is not scanned in the current scan cycle, it will decelerate and stop. In the TIME event, if the flag bit is set to 1 (stop sending pulses), there will be no pulse sending. 751 751 752 - When the flag bit is 1 (stop sending pulses), if the instruction is not scanned in the currentscan cycle,it will decelerate and stop. In theTIME event, if the flag bit is set to 1 (stop sending pulses), there will be no pulse sending.733 +**Subroutine** 753 753 754 - 2. Subroutine 755 - 756 756 If the high-speed pulse instruction is turned on in the subroutine, the high-speed pulse instruction will be sent as normal. If the scanning period is closed during pulse sending, select whether to continue sending or stop the pulse according to the unscanned processing flag. 757 757 758 758 (% class="table-bordered" %) 759 -|**Output shaft**|Y0|Y1|Y2|Y3|Y4|Y5|Y6|Y7 760 -|**Not scanned flag bit**|SM899|SM959|SM1019|SM1079|SM1139|SM1199|SM1259|SM1319 738 +|=(% scope="row" %)**Output shaft**|Y0|Y1|Y2|Y3|Y4|Y5|Y6|Y7 739 +|=**Not scanned flag bit**|SM899|SM959|SM1019|SM1079|SM1139|SM1199|SM1259|SM1319 761 761 762 762 When the flag bit is 0 (continue to send pulse), if the instruction is not scanned in the current scan cycle, the pulse will continue to be sent until it stops. At this time, it should be noted that if the subroutine is called again after the pulse is sent, the pulse will be sent again. 763 763 764 764 When the flag bit is 1 (stop sending pulses), if the subroutine is closed during high-speed pulse sending, the speed will decelerate and stop. If the subroutine is closed before sending the pulse, then no pulse is sent. 765 765 766 - 3.Interrupt745 +**Interrupt** 767 767 768 - 1.External interrupt747 +External interrupt 769 769 770 -If the high-speed pulse instruction is enabled in the external interrupt, the high-speed pulse instruction selects whether the pulse continues to be sent or the pulse stops according to the unscanned processing flag bit. 749 +* If the high-speed pulse instruction is enabled in the external interrupt, the high-speed pulse instruction selects whether the pulse continues to be sent or the pulse stops according to the unscanned processing flag bit. 771 771 772 772 (% class="table-bordered" %) 773 -|**Output shaft**|Y0|Y1|Y2|Y3|Y4|Y5|Y6|Y7 774 -|**Not scanned flag bit**|SM899|SM959|SM1019|SM1079|SM1139|SM1199|SM1259|SM1319 752 +|=(% scope="row" %)**Output shaft**|Y0|Y1|Y2|Y3|Y4|Y5|Y6|Y7 753 +|=**Not scanned flag bit**|SM899|SM959|SM1019|SM1079|SM1139|SM1199|SM1259|SM1319 775 775 776 -When the flag bit is 0 (continue to send pulse), continue to send high-speed pulses until it stops. 755 +* When the flag bit is 0 (continue to send pulse), continue to send high-speed pulses until it stops. 756 +* When the flag bit is 1 (stop sending pulse), the high-speed pulse decelerates and stops. 777 777 778 - Whenthe flag bit is 1 (stop sending pulse),thehigh-speed pulse decelerates and stops.758 +Timer interrupt 779 779 780 - 2.Timer interrupt760 +* If the high-speed pulse instruction is turned on in the timer interruption, the high-speed pulse instruction is sent as normal. If the instruction is not scanned in a certain scan period in the pulse transmission, the pulse continues to be sent or the pulse stops is selected according to the unscanned processing flag. 781 781 782 -If the high-speed pulse instruction is turned on in the timer interruption, the high-speed pulse instruction is sent as normal. If the instruction is not scanned in a certain scan period in the pulse transmission, the pulse continues to be sent or the pulse stops is selected according to the unscanned processing flag. 783 - 784 784 (% class="table-bordered" %) 785 -|**Output axis**|Y0|Y1|Y2|Y3|Y4|Y5|Y6|Y7 786 -|**Not scanned flag bit**|SM899|SM959|SM1019|SM1079|SM1139|SM1199|SM1259|SM1319 763 +|=(% scope="row" %)**Output axis**|Y0|Y1|Y2|Y3|Y4|Y5|Y6|Y7 764 +|=**Not scanned flag bit**|SM899|SM959|SM1019|SM1079|SM1139|SM1199|SM1259|SM1319 787 787 788 -When the flag bit is 0 (continue to send pulse), if the instruction is not scanned in the current scan cycle, continue to send pulses until it stops. In the timer interrupt, it is impossible to ensure that the instruction is scanned in every scan cycle, so it is necessary to avoid using high-speed pulse instructions in the T timer interrupt. Otherwise, after the pulse transmission is completed, the pulse will be sent again. 766 +* When the flag bit is 0 (continue to send pulse), if the instruction is not scanned in the current scan cycle, continue to send pulses until it stops. In the timer interrupt, it is impossible to ensure that the instruction is scanned in every scan cycle, so it is necessary to avoid using high-speed pulse instructions in the T timer interrupt. Otherwise, after the pulse transmission is completed, the pulse will be sent again. 767 +* When the flag bit is 1 (stop sending pulses), if the instruction is not scanned in the current scan cycle, it will decelerate and stop. In the TIME event, if the flag bit is set to 1 (stop sending pulses), there will be no pulse sending. 789 789 790 - When the flag bit is1 (stopsendingpulses), if the instruction is not scanned in the current scan cycle,it will decelerate andstop. Inthe TIME event,if the flag bit is set to 1 (stop sending pulses),there will be no pulse sending.769 +High-speed comparison interrupt 791 791 792 - 3.High-speed comparison interrupt771 +* If the high-speed pulse instruction is enabled in the high-speed comparison interrupt, the high-speed pulse instruction selects whether the pulse continues to be sent or the pulse stops according to the unscanned processing flag. 793 793 794 -If the high-speed pulse instruction is enabled in the high-speed comparison interrupt, the high-speed pulse instruction selects whether the pulse continues to be sent or the pulse stops according to the unscanned processing flag. 795 - 796 796 (% class="table-bordered" %) 797 -|**Output axis**|Y0|Y1|Y2|Y3|Y4|Y5|Y6|Y7 798 -|**Not scanned flag bit**|SM899|SM959|SM1019|SM1079|SM1139|SM1199|SM1259|SM1319 774 +|=(% scope="row" %)**Output axis**|Y0|Y1|Y2|Y3|Y4|Y5|Y6|Y7 775 +|=**Not scanned flag bit**|SM899|SM959|SM1019|SM1079|SM1139|SM1199|SM1259|SM1319 799 799 800 -When the flag bit is 0 (continue to send pulse), continue to send high-speed pulses until it stops. 801 - 802 -When the flag bit is 1 (stop sending pulse), the high-speed pulse decelerates and stops. 777 +* When the flag bit is 0 (continue to send pulse), continue to send high-speed pulses until it stops. 778 +* When the flag bit is 1 (stop sending pulse), the high-speed pulse decelerates and stops.