Changes for page 01 Program execution
Last modified by Leo Wei on 2024/12/24 22:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -20,11 +20,14 @@ 20 20 21 21 == Installation == 22 22 23 -* Please use it in the general specification environment described in the manual. 24 -** Do not use in the following places: places with dust, oily smoke, conductive dust, corrosive gas, flammable gas; places exposed to high temperature, condensation, wind and rain; places with vibration or impact. Electric shock, fire, and misoperation can also cause product damage. 25 -* When processing screw holes and wiring, do not let iron filings or wire ends fall into the ventilation window of the programmable controller. It may cause fire, malfunction, or misoperation. 26 -* Please insert the connecting cable and display module accurately into the specified sockets. Poor contact may cause misoperation. 23 +1. Please use it in the general specification environment described in the manual. 27 27 25 +Do not use in the following places: places with dust, oily smoke, conductive dust, corrosive gas, flammable gas; places exposed to high temperature, condensation, wind and rain; places with vibration or impact. Electric shock, fire, and misoperation can also cause product damage. 26 + 27 + 2. When processing screw holes and wiring, do not let iron filings or wire ends fall into the ventilation window of the programmable controller. It may cause fire, malfunction, or misoperation. 28 + 29 + 3. Please insert the connecting cable and display module accurately into the specified sockets. Poor contact may cause misoperation. 30 + 28 28 (% class="box infomessage" %) 29 29 ((( 30 30 **✎Note:** ... ... @@ -72,11 +72,14 @@ 72 72 **Attention** 73 73 )))|Do not connect the empty terminal to the outside, otherwise the product will be damaged. 74 74 75 -* Please connect the AC power supply to the dedicated terminal according to the content in the manual. 76 -* If the AC power supply is connected to the DC input/output terminal or the DC power supply terminal, the programmable controller will be burnt out. 77 -* Please do not supply power to the 24+ terminal of the basic unit from the external power supply, and to the empty terminal . Do not wire from the outside, otherwise the product will be damaged. 78 -* Please ground the ground terminal of the basic unit according to the third method. But please do not share the ground with the strong current system. 78 +Please connect the AC power supply to the dedicated terminal according to the content in the manual. 79 79 80 +If the AC power supply is connected to the DC input/output terminal or the DC power supply terminal, the programmable controller will be burnt out. 81 + 82 +Please do not supply power to the 24+ terminal of the basic unit from the external power supply, and to the empty terminal . Do not wire from the outside, otherwise the product will be damaged. 83 + 84 +Please ground the ground terminal of the basic unit according to the third method. But please do not share the ground with the strong current system. 85 + 80 80 **Attached** 81 81 82 82 The programmable controller will continue to work if there is an instantaneous power failure of less than 10ms. ... ... @@ -134,8 +134,8 @@ 134 134 * **×**: not execute 135 135 136 136 (% class="table-bordered" %) 137 -| =(% rowspan="2" %)**Processing item**|=(% colspan="3" %)**Status of the CPU module**138 -| =**When the power is ON**|=**STOP**|=**When STOP RUN**143 +|(% rowspan="2" %)**Processing item**|(% colspan="3" %)**Status of the CPU module** 144 +|**When the power is ON**|**STOP**|**When STOP RUN** 139 139 |Initialization of input and output modules|√|×|× 140 140 |CPU parameter check|√|×|× 141 141 |Check of system parameters|√|×|× ... ... @@ -146,11 +146,11 @@ 146 146 147 147 Perform the following before starting program calculation. 148 148 149 - *Update the actual input point of the PLC to the input relay X.155 +Update the actual input point of the PLC to the input relay X. 150 150 151 151 The following is executed after the END instruction is executed. 152 152 153 - *Update the PLC output relay Y to the actual output point.159 +Update the PLC output relay Y to the actual output point. 154 154 155 155 **Key points** 156 156 ... ... @@ -182,8 +182,10 @@ 182 182 183 183 It is the first scan time of the CPU module in RUN. 184 184 185 -Process as the following way: The value stored in SD134 (initial scan time (ms unit)) and SD135 (initial scan time (s unit)).191 +Process as the following way: 186 186 193 +The value stored in SD134 (initial scan time (ms unit)) and SD135 (initial scan time (s unit)). 194 + 187 187 = The flow of each procedure = 188 188 189 189 When the CPU module changes to the RUN state, the programs are executed in sequence according to the program execution type and execution sequence settings. ... ... @@ -195,11 +195,10 @@ 195 195 196 196 When the execution types of the programs are the same, they are executed in the order set in the execution order. 197 197 198 -(% class="box infomessage" %) 199 -((( 200 -**✎Note:** When executing instructions that can be completed with multiple cycles (such as OUT T, RAMP, RS, etc.), they should be programmed in the scan program. If it is used in event execution type programs and mid-stage execution type programs, these instructions may not be executed in multiple scan cycles, causing actual results to be different from the ideal results. Therefore, unless events, interrupts and subroutines can be executed in each scan cycle. It is not recommended to use multi-cycle execution instructions in other situations. 201 -))) 206 +**✎Note:** 202 202 208 +When executing instructions that can be completed with multiple cycles (such as OUT T, RAMP, RS, etc.), they should be programmed in the scan program. If it is used in event execution type programs and mid-stage execution type programs, these instructions may not be executed in multiple scan cycles, causing actual results to be different from the ideal results. Therefore, unless events, interrupts and subroutines can be executed in each scan cycle. It is not recommended to use multi-cycle execution instructions in other situations. 209 + 203 203 = Types of program execution = 204 204 205 205 == Scan execution program == ... ... @@ -218,11 +218,11 @@ 218 218 (% style="text-align:center" %) 219 219 [[image:1-5.png||height="372" width="300" class="img-thumbnail"]] 220 220 221 - 1.Scan the program name: the program name requires to match case, and the program name cannot use the same name with device name (the device name does not match case).222 - 1.The input of /%$@&=~~`^<>?:{}[],;!*.~\~\'" is not supported. It cannot exceed 64 characters. The default name is MAINx.223 - 1.The number of scan programs that can be built is limited to 100.224 - 1.Each scan program has been END ended, but only the last END instruction is completed to calculate a scan cycle.225 - 1.The execution sequence runs from top to bottom in the order of creation.228 +* Scan the program name: the program name requires to match case, and the program name cannot use the same name with device name (the device name does not match case). 229 +* The input of /%$@&=~~`^<>?:{}[],;!*.~\~\'" is not supported. It cannot exceed 64 characters. The default name is MAINx. 230 +* The number of scan programs that can be built is limited to 100. 231 +* Each scan program has been END ended, but only the last END instruction is completed to calculate a scan cycle. 232 +* The execution sequence runs from top to bottom in the order of creation. 226 226 227 227 (% style="text-align:center" %) 228 228 [[image:1-6.png||class="img-thumbnail"]] ... ... @@ -238,7 +238,7 @@ 238 238 239 239 The trigger of event execution type program is as follows. 240 240 241 -**ON event of bit data (TRUE)** 248 +**(1) ON event of bit data (TRUE)** 242 242 243 243 * After the ON event is specified, if the contact that sets the trigger condition in the ON event is turned ON during the scan program, the ON event program will be executed in the scan program page*1 or before the END instruction is executed. 244 244 * The ON event program will only be executed once in a single scan cycle. ... ... @@ -254,13 +254,13 @@ 254 254 The devices that can be specified are as follows. 255 255 256 256 (% class="table-bordered" %) 257 -| =(% colspan="2" %)**Project**|=**Content**264 +|(% colspan="2" %)**Project**|**Content** 258 258 |(% rowspan="2" %)Device *1|Bit Device|X, Y, M, SM 259 259 |Bit specification of word device|D.b 260 260 261 261 *1 The indexed device cannot be specified. 262 262 263 -**TIME event** 270 +**(2) TIME event** 264 264 265 265 After the program is to RUN state and the specified time has elapsed, event is executed one time when it comes to the execution sequence of the first corresponding program. For the second and subsequent executions, the time is re-measured from the start of the last event execution type program. After the specified time has elapsed, the program is executed repeatedly when it comes to the execution sequence of the first corresponding program. In addition, in the next scan after the corresponding program is executed, the current value of the output (Y) and timer (T) used in the corresponding program can be cleared. It can be used for programs that do not need to respond in a fixed period of time. 266 266 ... ... @@ -285,7 +285,7 @@ 285 285 Event program name: 286 286 287 287 * The program name requires to match case, and the program name with the same name as the device cannot be used (the device name does not match case). 288 -* The program name does not support /%$@&= ~~`^<>?:{}[],;!*.~\~\'" character input.295 +* The program name does not support /%$@&=to`^<>?:{}[],;!*.~\~\'" character input. 289 289 * The length of the program name cannot exceed 64 characters. The default name is EVENTx. 290 290 291 291 A maximum of 100 new event programs could be created. ... ... @@ -300,26 +300,26 @@ 300 300 (% style="text-align:center" %) 301 301 [[image:1-11.png||height="419" width="500" class="img-thumbnail"]] 302 302 303 - **Configuration instructions:**310 +Configuration instructions: 304 304 305 - Configuration interface 312 + 1) Configuration interface 306 306 307 307 (% style="text-align:center" %) 308 308 [[image:1-12.png||height="372" width="300" class="img-thumbnail"]] 309 309 310 -Parameter content: 317 +2) Parameter content: 311 311 312 312 (% class="table-bordered" %) 313 -| =(% colspan="2" %)**Project**|=(% style="width: 654px;" %)**Content**|=(% style="width: 190px;" %)**Setting range**|=**Default**314 -|(% colspan="2" %)Execution type| (% style="width:654px" %)Select event type|(% style="width:190px" %)Not set/ON event/TIME event|Not set315 -|(% rowspan="2" %)ON event|Contact| (% style="width:654px" %)The event type can be set when ON event is selected. Set the bit device as the trigger condition.|(% style="width:190px" %)X/Y/M/SM/D.b|316 -|Whether to clear| (% style="width:654px" %)When the bit device of the trigger condition set by the ON event is turned OFF, whether to clear the current value of the output (Y) and timer (T) used in the execution program of the ON event in the next cycle.|(% style="width:190px" %)(((320 +|(% colspan="2" %)**Project**|**Content**|**Setting range**|**Default** 321 +|(% colspan="2" %)Execution type|Select event type|Not set/ON event/TIME event|Not set 322 +|(% rowspan="2" %)ON event|Contact|The event type can be set when ON event is selected. Set the bit device as the trigger condition.|X/Y/M/SM/D.b| 323 +|Whether to clear|When the bit device of the trigger condition set by the ON event is turned OFF, whether to clear the current value of the output (Y) and timer (T) used in the execution program of the ON event in the next cycle.|((( 317 317 True 318 318 319 319 False 320 320 )))|False 321 -|(% rowspan="2" %)TIME event|Time| (% style="width:654px" %)Set how long to execute the event program once.|(% style="width:190px"%)1to 2147483647 (100us unit)|322 -|Whether to clear| (% style="width:654px" %)When the TIME event is executed, if the event is not executed in the next scan cycle, select whether to clear the output (Y) used in the TIME event execution program and the current value of the timer (T).|(% style="width:190px" %)(((328 +|(% rowspan="2" %)TIME event|Time|Set how long to execute the event program once.|1 to 2147483647 (100us unit)| 329 +|Whether to clear|When the TIME event is executed, if the event is not executed in the next scan cycle, select whether to clear the output (Y) used in the TIME event execution program and the current value of the timer (T).|((( 323 323 True 324 324 325 325 False ... ... @@ -333,60 +333,78 @@ 333 333 334 334 In the process of executing the scan program, the program that can interrupt the priority execution of the scan program is called an interrupt execution program. 335 335 336 - *When an interrupt cause occurs, the interrupt program corresponding to the interrupt pointer number will be executed. However, the execution needs to be set to the interrupt enabled state by the EI instruction.343 + ~1. When an interrupt cause occurs, the interrupt program corresponding to the interrupt pointer number will be executed. However, the execution needs to be set to the interrupt enabled state by the EI instruction. 337 337 338 338 (% style="text-align:center" %) 339 339 [[image:1652249587490-678.png||class="img-thumbnail"]] 340 340 341 341 342 -* An interrupt name corresponds to an interrupt program, and the interrupt name cannot be repeated. Each interrupt has its own trigger condition and execution program, and each interrupt program ends with END. 343 -* Interrupt has the characteristic of interrupting the original execution program and executing the interrupt first, but it cannot interrupt the interrupt program being executed. 344 -* The interrupt program has the concept of priority. The smaller the priority value, the more priority the response. The priority setting range is 0 to 2. 349 + 2. An interrupt name corresponds to an interrupt program, and the interrupt name cannot be repeated. Each interrupt has its own trigger condition and execution program, and each interrupt program ends with END. 345 345 346 - **The actionswhenaninterruption causeoccurs areasfollows:**351 + 3. Interrupt has the characteristic of interrupting the original execution program and executing the interrupt first, but it cannot interrupt the interrupt program being executed. 347 347 348 -* Interrupt prohibition (DI) when an interruption cause occurs. 349 -** If the interrupt execution condition is triggered in a program that is forbidden by DI, the interrupt will not be executed. Even if the subsequent program uses the EI instruction to allow interruption, the previously shielded interrupt program will not be executed. Only the interrupt execution condition is triggered again. The interrupt program will be executed. 350 -* When multiple interrupt causes occur simultaneously in the interrupt enabled state. 351 -** The interrupt program with higher priority will be executed sequentially. In addition, when multiple interrupts with the same priority occur at the same time, the actions are executed in the order of interrupt priority. 352 -** If three interrupt programs I0, I10, I16 are created, the priority of I0 is 1, the priority of I10 is 0, and the priority of I16 is 1. The execution logic is shown in the figure below: I10 has the smallest priority and is executed first; I0 and I16 have the same priority and are executed in the order of program establishment. 353 + 4. The interrupt program has the concept of priority. The smaller the priority value, the more priority the response. The priority setting range is 0 to 2. 353 353 355 +The actions when an interruption cause occurs are as follows: 356 + 357 +1. Interrupt prohibition (DI) when an interruption cause occurs. 358 + 359 +If the interrupt execution condition is triggered in a program that is forbidden by DI, the interrupt will not be executed. Even if the subsequent program uses the EI instruction to allow interruption, the previously shielded interrupt program will not be executed. Only the interrupt execution condition is triggered again. The interrupt program will be executed. 360 + 361 + 2.When multiple interrupt causes occur simultaneously in the interrupt enabled state. 362 + 363 +The interrupt program with higher priority will be executed sequentially. In addition, when multiple interrupts with the same priority occur at the same time, the actions are executed in the order of interrupt priority. 364 + 365 +If three interrupt programs I0, I10, I16 are created, the priority of I0 is 1, the priority of I10 is 0, and the priority of I16 is 1. The execution logic is shown in the figure below: I10 has the smallest priority and is executed first; I0 and I16 have the same priority and are executed in the order of program establishment. 366 + 354 354 (% style="text-align:center" %) 355 355 [[image:1652249553246-688.png||class="img-thumbnail"]] 356 356 357 -* When an interrupt occurs during the waiting time when performing constant scan. 358 -** Execute the interrupt program for this interrupt. 359 -* When other interrupts occur during the execution of the interrupt program. 360 -** In the interrupt program (including the specification when the interrupt occurs in the event execution program), when other interrupts occur, the original interrupt execution program will not be interrupted. After the original interrupt execution program is completed, the new interrupt program is executed. After the execution is completed Then return to the scanning procedure. 361 -* During the execution of the interrupt program, when an interrupt cause with a low priority or the same priority occurs. 362 -** The interruption cause that occurred is stored, and after the interrupt program in execution ends, the interrupt program corresponding to the stored interruption cause is executed. Even if the same interruption cause occurs multiple times, the interruption cause is stored only once. 370 + 3. When an interrupt occurs during the waiting time when performing constant scan. 363 363 372 +Execute the interrupt program for this interrupt. 373 + 374 + 4.When other interrupts occur during the execution of the interrupt program. 375 + 376 +In the interrupt program (including the specification when the interrupt occurs in the event execution program), when other interrupts occur, the original interrupt execution program will not be interrupted. After the original interrupt execution program is completed, the new interrupt program is executed. After the execution is completed Then return to the scanning procedure. 377 + 378 + 5. During the execution of the interrupt program, when an interrupt cause with a low priority or the same priority occurs. 379 + 380 +The interruption cause that occurred is stored, and after the interrupt program in execution ends, the interrupt program corresponding to the stored interruption cause is executed. Even if the same interruption cause occurs multiple times, the interruption cause is stored only once. 381 + 382 + 364 364 (% style="text-align:center" %) 365 365 [[image:1652249673420-476.png||class="img-thumbnail"]] 366 366 367 -* When the same interruption cause occurs during the execution of the interrupt program; 368 -** The interruption cause that occurred is stored, and after the interrupt program in execution ends, the interrupt program corresponding to the stored interruption cause is executed. Even if the same interruption cause occurs multiple times, the interruption cause is stored only once. 386 + 6. When the same interruption cause occurs during the execution of the interrupt program; 369 369 388 +The interruption cause that occurred is stored, and after the interrupt program in execution ends, the interrupt program corresponding to the stored interruption cause is executed. Even if the same interruption cause occurs multiple times, the interruption cause is stored only once. 389 + 370 370 **Interrupt trigger condition classification** 371 371 372 -* **External input (X) interrupt** 373 -** Description of external input interrupt 374 -*** The external input interrupt is triggered by the rising or falling edge of the fixed X point input. 375 -*** Supports the rising and falling edge interrupts of a total of 8 input points of X0 to X7, and supports a total of 16 external input interrupts. 376 -*** The same interrupt trigger condition cannot create multiple interrupt programs. 377 -*** External input interrupt and high-speed counter cannot use the same X point. 378 -*** You must use EI in the scan program to allow interrupts before the interrupt execution program will be executed. 379 -* **External input interrupt steps.** 380 -** Project management→ Program→ Interrupt→ right click to create. 381 -** The interrupt program name requires to match case, and the program name with the same name as the device cannot be used (the device name does not match case), 382 -** The interrupt program name does not support the input of /%$@&=~~`^<>?:{}[],;!*.~\~\'" characters, 383 -** The length of the interrupt program name cannot exceed 64 characters and cannot be typed. The default name is INTx. 392 +1. **External input (X) interrupt** 384 384 394 +**~ **1. Description of external input interrupt 395 + 396 +1. The external input interrupt is triggered by the rising or falling edge of the fixed X point input. 397 +1. Supports the rising and falling edge interrupts of a total of 8 input points of X0 to X7, and supports a total of 16 external input interrupts. 398 +1. The same interrupt trigger condition cannot create multiple interrupt programs. 399 +1. External input interrupt and high-speed counter cannot use the same X point. 400 +1. You must use EI in the scan program to allow interrupts before the interrupt execution program will be executed. 401 + 402 + 2. External input interrupt steps. 403 + 404 +Project management→ Program→ Interrupt→ right click to create 405 + 385 385 (% style="text-align:center" %) 386 386 [[image:1-16.png||class="img-thumbnail"]] 387 387 388 -* Click Configure, and select external interrupt for execution type, as shown in the figure below (it can also be configured in "program parameters" in "parameters" in project management): 409 +1. The interrupt program name requires to match case, and the program name with the same name as the device cannot be used (the device name does not match case), 410 +1. The interrupt program name does not support the input of /%$@&=to`^<>?:{}[],;!*.~\~\'" characters, 411 +1. The length of the interrupt program name cannot exceed 64 characters and cannot be typed. The default name is INTx. 389 389 413 +Click Configure, and select external interrupt for execution type, as shown in the figure below (it can also be configured in "program parameters" in "parameters" in project management): 414 + 390 390 (% style="text-align:center" %) 391 391 [[image:1-17.png||class="img-thumbnail"]] 392 392 ... ... @@ -406,7 +406,7 @@ 406 406 Note: X rising edge interrupt and X falling edge interrupt use the same X filter, so after the filter setting is changed in the X rising edge configuration, the X falling edge will also change. If the filter time is set to 1000, you must ensure that the high level and low level of the input signal are maintained for more than 10 us before the interrupt can be triggered. 407 407 )))|0 to 1700|1 408 408 409 - *Write interrupt execution program434 +1. Write interrupt execution program 410 410 411 411 (% style="text-align:center" %) 412 412 [[image:1-18.png||class="img-thumbnail"]] ... ... @@ -416,19 +416,19 @@ 416 416 (% style="text-align:center" %) 417 417 [[image:1652250056160-117.png||height="215" width="500" class="img-thumbnail"]] 418 418 419 -**Timer interrupt** 444 +**~ 2.Timer interrupt** 420 420 421 -Timer interrupt description 446 +1. Timer interrupt description 422 422 423 - *Timer interrupt is based on the set time, execute the interrupt program every this time, the minimum time interval can reach 100us.424 - *Up to 100 timer interrupt execution programs can be created.425 - *Each timer interrupt program is independent of each other and does not affect each other.426 - *Each timer interrupt program should be configured with priority. When triggered at the same time, it is executed in the order of priority, but when the priority is the same, it is executed in the order of the established program.427 - *The interrupt execution program is executed only after EI is used in the scanner to allow the interrupt448 +1. Timer interrupt is based on the set time, execute the interrupt program every this time, the minimum time interval can reach 100us. 449 +1. Up to 100 timer interrupt execution programs can be created. 450 +1. Each timer interrupt program is independent of each other and does not affect each other. 451 +1. Each timer interrupt program should be configured with priority. When triggered at the same time, it is executed in the order of priority, but when the priority is the same, it is executed in the order of the established program. 452 +1. The interrupt execution program is executed only after EI is used in the scanner to allow the interrupt 428 428 429 -Timer interrupt step 454 + 2. Timer interrupt step 430 430 431 - *Project managementðProgramðInterruptðRight click to create. Enter the program name. The program name only supports the combination of English letters, numbers, and underscores, and must start with an English letter. The default is INTx. Click Configure and select Timer Interrupt as the execution type, as shown in the figure below (it can also be configured in "program parameters" in "parameters" in project management).456 +Project managementðProgramðInterruptðRight click to create. Enter the program name. The program name only supports the combination of English letters, numbers, and underscores, and must start with an English letter. The default is INTx. Click Configure and select Timer Interrupt as the execution type, as shown in the figure below (it can also be configured in "program parameters" in "parameters" in project management). 432 432 433 433 (% style="text-align:center" %) 434 434 [[image:1-20.png||class="img-thumbnail"]] ... ... @@ -439,35 +439,34 @@ 439 439 |(% rowspan="2" %)Timer interrupt|Time|Set the interval time for interrupt triggering|1 to 2147483647 (100us unit)| 440 440 |priority|When multiple interrupts arrive at the same time, the order of priority execution, the smallest value is executed first|0 to 2|0 441 441 442 -Write interrupt execution program 467 +1. Write interrupt execution program 443 443 444 444 (% style="text-align:center" %) 445 445 [[image:1-21.png||class="img-thumbnail"]] 446 446 447 - *Double-click the newly created timer interrupt program in the project management to start writing the interrupt execution program. As shown in the figure above, a newly created timer interrupt program is INT0, and the trigger condition is configured to execute the interrupt program every 10ms. If the main program uses EI to enable interrupts, all instruction programs in INT0 will be executed every 10ms, namely D0 It will add 1 to 10ms.472 +Double-click the newly created timer interrupt program in the project management to start writing the interrupt execution program. As shown in the figure above, a newly created timer interrupt program is INT0, and the trigger condition is configured to execute the interrupt program every 10ms. If the main program uses EI to enable interrupts, all instruction programs in INT0 will be executed every 10ms, namely D0 It will add 1 to 10ms. 448 448 449 449 (% style="text-align:center" %) 450 450 [[image:1652250294005-455.png||class="img-thumbnail"]] 451 451 452 -**High-speed counter interrupt** 477 +**~ 3. High-speed counter interrupt** 453 453 454 -Description of high-speed counter interrupt 479 +1. Description of high-speed counter interrupt 455 455 456 - *The high-speed counter interrupt triggers an interrupt condition after the set value of the high-speed counter HSC0 to HSC7 provided by the PLC and executes the interrupt program.457 - *It can support up to 100 high-speed counter interrupt programs, but the number that can be supported by each channel does not need to be fixed.458 - *When using the high-speed counter interrupt, project must configure the high-speed counter and use the OUT HSC instruction to enable the corresponding counting channel to count before it can be used (see the high-speed counter description section for the specific configuration method).459 - *Each high-speed counter interrupt program should be configured with priority. When triggered at the same time, it will be executed in the order of priority. When the priority is the same, it will be executed in the order of channels HSC0-HSC7. When the channel is also the same, it is executed in order according to the creation promise.460 - *Project must use EI in the scan program to allow interrupts before the interrupt execution program will be executed.481 +1. The high-speed counter interrupt triggers an interrupt condition after the set value of the high-speed counter HSC0 to HSC7 provided by the PLC and executes the interrupt program. 482 +1. It can support up to 100 high-speed counter interrupt programs, but the number that can be supported by each channel does not need to be fixed. 483 +1. When using the high-speed counter interrupt, project must configure the high-speed counter and use the OUT HSC instruction to enable the corresponding counting channel to count before it can be used (see the high-speed counter description section for the specific configuration method). 484 +1. Each high-speed counter interrupt program should be configured with priority. When triggered at the same time, it will be executed in the order of priority. When the priority is the same, it will be executed in the order of channels HSC0-HSC7. When the channel is also the same, it is executed in order according to the creation promise. 485 +1. Project must use EI in the scan program to allow interrupts before the interrupt execution program will be executed. 461 461 462 -(% class="box infomessage" %) 463 -((( 464 -**✎Note: **Both the HSC channel and the external input interrupt channel must use the PLC input point X. It should be noted that it cannot be reused during configuration. For details, please refer to the configuration chapter of the high-speed counter. 465 -))) 487 +**✎Note: **Both the HSC channel and the external input interrupt channel must use the PLC input point X. It should be noted that it 466 466 467 - High-speed counter interrupt steps489 +cannot be reused during configuration. For details, please refer to the configuration chapter of the high-speed counter. 468 468 469 - * “Project management”ð“Programð“Interrupt”ðRight click to create.Enter the program name. The program name onlysupports thecombination of English letters, numbers, andunderscores, and must start with anEnglish letter.The defaultis INTx. Click Configure, selecthigh-speed interruptfor execution type, asshown inthefigure below (it can also be configured in "program parameters" in "parameters" in project management).491 +1. high-speed counter interrupt step 470 470 493 +“Project management”ð“Programð“Interrupt”ðRight click to create. Enter the program name. The program name only supports the combination of English letters, numbers, and underscores, and must start with an English letter. The default is INTx. Click Configure, select high-speed interrupt for execution type, as shown in the figure below (it can also be configured in "program parameters" in "parameters" in project management). 494 + 471 471 (% style="text-align:center" %) 472 472 [[image:1-23.png||class="img-thumbnail"]] 473 473 ... ... @@ -500,57 +500,56 @@ 500 500 |Priority|When multiple interrupts arrive at the same time, the order of priority execution, the smallest value is executed first|0 to 2|0 501 501 |Contact|It is available when selecting high-speed comparison set and high-speed comparison reset. The contact is set or reset immediately after the trigger condition is reached.|Y/M/D.b| 502 502 503 - Description of triggering rules 527 + 3. Description of triggering rules 504 504 505 505 (% class="table-bordered" %) 506 -| (% style="width:135px" %)**Mode**|(% style="width:187px" %)**Configuration**|(% style="width:128px" %)**The current value**|(% style="width:324px" %)**Action**507 -|(% rowspan="2" style="width:135px"%)High-speed compare interrupt (INT0)|(% rowspan="2"style="width:187px"%)Comparison value: 10000|(% style="width:128px" %)9999 → 10000|(% style="width:324px" %)Execute all programs in interrupt INT0508 -| (% style="width:128px" %)10001 → 10000|(% style="width:324px" %)Execute all programs in interrupt INT0509 -|(% rowspan="2" style="width:135px"%)High-speed comparison set (INT1)|(% rowspan="2"style="width:187px"%)(((530 +|**Mode**|**Configuration**|**The current value**|**Action** 531 +|(% rowspan="2" %)High-speed compare interrupt (INT0)|(% rowspan="2" %)Comparison value: 10000|9999 → 10000|Execute all programs in interrupt INT0 532 +|10001 → 10000|Execute all programs in interrupt INT0 533 +|(% rowspan="2" %)High-speed comparison set (INT1)|(% rowspan="2" %)((( 510 510 Comparison value: -50,000 511 511 512 512 Contact: Y10 513 -)))| (% style="width:128px" %)-50001 → -50000|(% style="width:324px" %)(((537 +)))|-50001 → -50000|((( 514 514 Y10 is immediately set and mapped to the actual output (not affected by the scan period) 515 515 516 516 The program in INT1 will not be executed 517 517 ))) 518 -| (% style="width:128px" %)-49999 → -50000|(% style="width:324px" %)(((542 +|-49999 → -50000|((( 519 519 Y10 is immediately set and mapped to the actual output (not affected by the scan period) 520 520 521 521 The program in INT1 will not be executed 522 522 ))) 523 -|(% rowspan="2" style="width:135px"%)High-speed comparison reset (INT2)|(% rowspan="2"style="width:187px"%)(((547 +|(% rowspan="2" %)High-speed comparison reset (INT2)|(% rowspan="2" %)((( 524 524 Comparison value: 400000 525 525 526 526 Contact: Y10 527 -)))| (% style="width:128px" %)399999 → 400000|(% style="width:324px" %)(((551 +)))|399999 → 400000|((( 528 528 Y10 is reset immediately and mapped to the actual output (not affected by the scan period) 529 529 530 530 The program in INT2 will not be executed 531 531 ))) 532 -| (% style="width:128px" %)400001 → 400000|(% style="width:324px" %)(((556 +|400001 → 400000|((( 533 533 Y10 is reset immediately and mapped to the actual output (not affected by the scan period) 534 534 535 535 The program in INT2 will not be executed 536 536 ))) 537 537 538 -(% class="box infomessage" %) 539 -((( 540 540 **✎Note: **Both HSC channel and external input interrupt channel need to use the INPUT point X, so it should be noted that it cannot be reused in configuration. For details, please refer to the configuration section of high-speed counter. 541 -))) 542 542 543 -Write interrupt execution program 564 +1. Write interrupt execution program 544 544 545 545 * New interrupt program 546 -** Create three new interrupt programs under the interrupt of project management, namely HSC0_20000, HSC0_30000, HSC0_40000. Configure the interrupt program in the "program parameters", as shown in the figure below. 547 547 568 +Create three new interrupt programs under the interrupt of project management, namely HSC0_20000, HSC0_30000, HSC0_40000. Configure the interrupt program in the "program parameters", as shown in the figure below. 569 + 548 548 (% style="text-align:center" %) 549 549 [[image:1-24.png||class="img-thumbnail"]] 550 550 551 551 * High-speed counter configuration 552 -** Configure HSC0 for use in the high-speed counter configuration. After selecting the working mode, click the "Check” button. After the correct configuration box pops up, click Enter. 553 553 575 +Configure HSC0 for use in the high-speed counter configuration. After selecting the working mode, click the "Check” button. After the correct configuration box pops up, click Enter. 576 + 554 554 (% style="text-align:center" %) 555 555 [[image:1-25.png||class="img-thumbnail"]] 556 556 ... ... @@ -560,119 +560,127 @@ 560 560 561 561 Program operation: 562 562 563 -* Assuming that the High-speed counter channel 0 has been receiving pulses: 564 -** When the count value of HSC0 accumulates from 0 to 20000, all procedures of HSC0_20000 are executed. 565 -** When the count value of HSC0 is accumulated from 20000 to 30000, all procedures of HSC0_30000 are executed. 566 -** When the count value of HSC0 is accumulated from 30000 to 40000, all procedures of HSC0_40000 are executed. 586 +Assuming that the High-speed counter channel 0 has been receiving pulses: 567 567 588 +When the count value of HSC0 accumulates from 0 to 20000, all procedures of HSC0_20000 are executed. 589 + 590 +When the count value of HSC0 is accumulated from 20000 to 30000, all procedures of HSC0_30000 are executed. 591 + 592 +When the count value of HSC0 is accumulated from 30000 to 40000, all procedures of HSC0_40000 are executed. 593 + 568 568 **Mask interrupt** 569 569 570 -Mask through application instructions 596 +**~ 1. Mask through application instructions** 571 571 572 -* The PLC interrupt is in the shielded state by default when it is powered on, and can only be used after the interrupt is allowed through the EI instruction. 573 -* The interrupt mask instruction DI masks all interrupts without parameters, and masks some priority interrupts with parameters (refer to the program flow instruction DI/EI for details). 598 +The PLC interrupt is in the shielded state by default when it is powered on, and can only be used after the interrupt is allowed through the EI instruction. 574 574 575 - Mask throughspecialregistersSMandSD600 +The interrupt mask instruction DI masks all interrupts without parameters, and masks some priority interrupts with parameters (refer to the program flow instruction DI/EI for details). 576 576 602 +**~ 2. Mask through special registers SM and SD** 603 + 604 +1.External input interrupt mask register 605 + 577 577 (% class="table-bordered" %) 578 -| =(% colspan="4" %)**External input interrupt mask register**579 -| =(% style="width: 266px;" %)**Special register number**|=(% style="width: 308px;" %)**Type of interrupt**|=(% style="width: 390px;" %)**Instruction**|=**Defaults**580 -| (% style="width:266px" %)SM352|(% style="width:308px" %)X0 rising edge interrupt|(% style="width:390px" %)ON: shieldinterrupts;OFF: interruptallowed|OFF581 -| (% style="width:266px" %)SM353|(% style="width:308px" %)X0 falling edge interrupt|(% style="width:390px" %)ON: shieldinterrupts;OFF: interruptallowed|OFF582 -| (% style="width:266px" %)SM354|(% style="width:308px" %)X1 rising edge interrupt|(% style="width:390px" %)ON: shieldinterrupts;OFF: interruptallowed|OFF583 -| (% style="width:266px" %)SM355|(% style="width:308px" %)X1 falling edge interrupt|(% style="width:390px" %)ON: shieldinterrupts;OFF: interruptallowed|OFF584 -| (% style="width:266px" %)SM356|(% style="width:308px" %)X2 rising edge interrupt|(% style="width:390px" %)ON: shieldinterrupts;OFF: interruptallowed|OFF585 -| (% style="width:266px" %)SM357|(% style="width:308px" %)X2 falling edge interrupt|(% style="width:390px" %)ON: shieldinterrupts;OFF: interruptallowed|OFF586 -| (% style="width:266px" %)SM358|(% style="width:308px" %)X3 rising edge interrupt|(% style="width:390px" %)ON: shieldinterrupts;OFF: interruptallowed|OFF587 -| (% style="width:266px" %)SM359|(% style="width:308px" %)X3 falling edge interrupt|(% style="width:390px" %)ON:Shieldinterrupts;OFF: interruptallowed|OFF588 -| (% style="width:266px" %)SM360|(% style="width:308px" %)X4 rising edge interrupt|(% style="width:390px" %)ON: shieldinterrupts;OFF: interruptallowed|OFF589 -| (% style="width:266px" %)SM361|(% style="width:308px" %)X4 falling edge interrupt|(% style="width:390px" %)ON: shieldinterrupts;OFF: interruptallowed|OFF590 -| (% style="width:266px" %)SM362|(% style="width:308px" %)X5 rising edge interrupt|(% style="width:390px" %)ON: shieldinterrupts;OFF: interruptallowed|OFF591 -| (% style="width:266px" %)SM363|(% style="width:308px" %)X5 falling edge interrupt|(% style="width:390px" %)ON:Shieldinterrupts;OFF: interruptallowed|OFF592 -| (% style="width:266px" %)SM364|(% style="width:308px" %)X6 rising edge interrupt|(% style="width:390px" %)ON: shieldinterrupts;OFF: interruptallowed|OFF593 -| (% style="width:266px" %)SM365|(% style="width:308px" %)X6 falling edge interrupt|(% style="width:390px" %)ON: shieldinterrupts;OFF: interruptallowed|OFF594 -| (% style="width:266px" %)SM366|(% style="width:308px" %)X7 rising edge interrupt|(% style="width:390px" %)ON: shieldinterrupts;OFF: interruptallowed|OFF595 -| (% style="width:266px" %)SM367|(% style="width:308px" %)X7 falling edge interrupt|(% style="width:390px" %)ON: shieldinterrupts;OFF: interruptallowed|OFF607 +|(% colspan="4" %)**External input interrupt mask register** 608 +|**Special register number**|**Type of interrupt**|**Instruction**|**Defaults** 609 +|SM352|X0 rising edge interrupt|ON: Mask interrupt OFF: Enable interrupt|OFF 610 +|SM353|X0 falling edge interrupt|ON: Mask interrupt OFF: Enable interrupt|OFF 611 +|SM354|X1 rising edge interrupt|ON: Mask interrupt OFF: Enable interrupt|OFF 612 +|SM355|X1 falling edge interrupt|ON: Mask interrupt OFF: Enable interrupt|OFF 613 +|SM356|X2 rising edge interrupt|ON: Mask interrupt OFF: Enable interrupt|OFF 614 +|SM357|X2 falling edge interrupt|ON: Mask interrupt OFF: Enable interrupt|OFF 615 +|SM358|X3 rising edge interrupt|ON: Mask interrupt OFF: Enable interrupt|OFF 616 +|SM359|X3 falling edge interrupt|ON: Mask interrupt OFF: Enable interrupt|OFF 617 +|SM360|X4 rising edge interrupt|ON: Mask interrupt OFF: Enable interrupt|OFF 618 +|SM361|X4 falling edge interrupt|ON: Mask interrupt OFF: Enable interrupt|OFF 619 +|SM362|X5 rising edge interrupt|ON: Mask interrupt OFF: Enable interrupt|OFF 620 +|SM363|X5 falling edge interrupt|ON: Mask interrupt OFF: Enable interrupt|OFF 621 +|SM364|X6 rising edge interrupt|ON: Mask interrupt OFF: Enable interrupt|OFF 622 +|SM365|X6 falling edge interrupt|ON: Mask interrupt OFF: Enable interrupt|OFF 623 +|SM366|X7 rising edge interrupt|ON: Mask interrupt OFF: Enable interrupt|OFF 624 +|SM367|X7 falling edge interrupt|ON: Mask interrupt OFF: Enable interrupt|OFF 596 596 626 +2. Timer interrupt mask register 627 + 597 597 (% class="table-bordered" %) 598 -| =(% colspan="4" %)**Timer interrupt mask register**599 -| =**Special register number**|=(% style="width: 311px;" %)**Type of interrupt**|=(% style="width: 391px;" %)**Instruction**|=(% style="width: 110px;" %)**Default**600 -|SD350| (% style="width:311px" %)1st to 16th timer interrupt|(% style="width:391px" %)(((629 +|(% colspan="4" %)**Timer interrupt mask register** 630 +|**Special register number**|**Type of interrupt**|**Instruction**|**Default** 631 +|SD350|1st to 16th timer interrupt|((( 601 601 Each bit can control the mask of an interrupt. 602 602 603 -ON: s hieldinterrupts;OFF: interruptallowed604 -)))| (% style="width:110px" %)0605 -|SD351| (% style="width:311px" %)17th to 32th timer interrupt|(% style="width:391px" %)(((634 +ON: Mask interrupt OFF: Enable interrupt 635 +)))|0 636 +|SD351|17th to 32th timer interrupt|((( 606 606 Each bit can control the mask of an interrupt. 607 607 608 -ON: s hieldinterrupts;OFF: interruptallowed609 -)))| (% style="width:110px" %)0610 -|SD352| (% style="width:311px" %)33th to 48th timer interrupt|(% style="width:391px" %)(((639 +ON: Mask interrupt OFF: Enable interrupt 640 +)))|0 641 +|SD352|33th to 48th timer interrupt|((( 611 611 Each bit can control the mask of an interrupt. 612 612 613 -ON: s hieldinterrupts;OFF: interruptallowed614 -)))| (% style="width:110px" %)0615 -|SD353| (% style="width:311px" %)49th to 64th timer interrupt|(% style="width:391px" %)(((644 +ON: Mask interrupt OFF: Enable interrupt 645 +)))|0 646 +|SD353|49th to 64th timer interrupt|((( 616 616 Each bit can control the mask of an interrupt. 617 617 618 -ON: s hieldinterrupts;OFF: interruptallowed619 -)))| (% style="width:110px" %)0620 -|SD354| (% style="width:311px" %)65th to 80th timer interrupt|(% style="width:391px" %)(((649 +ON: Mask interrupt OFF: Enable interrupt 650 +)))|0 651 +|SD354|65th to 80th timer interrupt|((( 621 621 Each bit can control the mask of an interrupt. 622 622 623 -ON: s hieldinterrupts;OFF: interruptallowed624 -)))| (% style="width:110px" %)0625 -|SD355| (% style="width:311px" %)81st to 96th timer interrupt|(% style="width:391px" %)(((654 +ON: Mask interrupt OFF: Enable interrupt 655 +)))|0 656 +|SD355|81st to 96th timer interrupt|((( 626 626 Each bit can control the mask of an interrupt. 627 627 628 -ON: s hieldinterrupts;OFF: interruptallowed629 -)))| (% style="width:110px" %)0630 -|SD356| (% style="width:311px" %)97th to 100th timer interrupt|(% style="width:391px" %)(((659 +ON: Mask interrupt OFF: Enable interrupt 660 +)))|0 661 +|SD356|97th to 100th timer interrupt|((( 631 631 Each bit can control the mask of an interrupt. 632 632 633 -ON: s hieldinterrupts;OFF: interruptallowed634 -)))| (% style="width:110px" %)0664 +ON: Mask interrupt OFF: Enable interrupt 665 +)))|0 635 635 636 636 1. high-speed counter interrupt mask register 637 637 638 638 (% class="table-bordered" %) 639 -| =(% colspan="4" %)**High-speed counter interrupt mask register**640 -| =(% style="width: 230px;" %)**Special register number**|=(% style="width: 348px;" %)**Type of interrupt**|=(% style="width: 387px;" %)**Instruction**|=(% style="width: 110px;" %)**Default**641 -| (% style="width:230px" %)SD382|(% style="width:348px" %)1st to 16th high-speed counter interrupt|(% style="width:387px" %)(((670 +|(% colspan="4" %)**High-speed counter interrupt mask register** 671 +|**Special register number**|**Type of interrupt**|**Instruction**|**Default** 672 +|SD382|1st to 16th high-speed counter interrupt|((( 642 642 Each bit can control the mask of an interrupt. 643 643 644 -ON: s hieldinterrupts;OFF: interruptallowed645 -)))| (% style="width:110px" %)0646 -| (% style="width:230px" %)SD383|(% style="width:348px" %)17th to 32nd high-speed counter interrupt|(% style="width:387px" %)(((675 +ON: Mask interrupt OFF: Enable interrupt 676 +)))|0 677 +|SD383|17th to 32nd high-speed counter interrupt|((( 647 647 Each bit can control the mask of an interrupt. 648 648 649 -ON: s hieldinterrupts;OFF: interruptallowed650 -)))| (% style="width:110px" %)0651 -| (% style="width:230px" %)SD384|(% style="width:348px" %)33th to 48th high-speed counter interrupt|(% style="width:387px" %)(((680 +ON: Mask interrupt OFF: Enable interrupt 681 +)))|0 682 +|SD384|33th to 48th high-speed counter interrupt|((( 652 652 Each bit can control the mask of an interrupt. 653 653 654 -ON: s hieldinterrupts;OFF: interruptallowed655 -)))| (% style="width:110px" %)0656 -| (% style="width:230px" %)SD385|(% style="width:348px" %)49th to 64th high-speed counter interrupt|(% style="width:387px" %)(((685 +ON: Mask interrupt OFF: Enable interrupt 686 +)))|0 687 +|SD385|49th to 64th high-speed counter interrupt|((( 657 657 Each bit can control the mask of an interrupt. 658 658 659 -ON: s hieldinterrupts;OFF: interruptallowed660 -)))| (% style="width:110px" %)0661 -| (% style="width:230px" %)SD386|(% style="width:348px" %)65th to 80th high-speed counter interrupt|(% style="width:387px" %)(((690 +ON: Mask interrupt OFF: Enable interrupt 691 +)))|0 692 +|SD386|65th to 80th high-speed counter interrupt|((( 662 662 Each bit can control the mask of an interrupt. 663 663 664 -ON: s hieldinterrupts;OFF: interruptallowed665 -)))| (% style="width:110px" %)0666 -| (% style="width:230px" %)SD387|(% style="width:348px" %)81st to 96th high-speed counter interrupt|(% style="width:387px" %)(((695 +ON: Mask interrupt OFF: Enable interrupt 696 +)))|0 697 +|SD387|81st to 96th high-speed counter interrupt|((( 667 667 Each bit can control the mask of an interrupt. 668 668 669 -ON: s hieldinterrupts;OFF: interruptallowed670 -)))| (% style="width:110px" %)0671 -| (% style="width:230px" %)SD388|(% style="width:348px" %)97th to 100th high-speed counter interrupt|(% style="width:387px" %)(((700 +ON: Mask interrupt OFF: Enable interrupt 701 +)))|0 702 +|SD388|97th to 100th high-speed counter interrupt|((( 672 672 Each bit can control the mask of an interrupt. 673 673 674 -ON: s hieldinterrupts;OFF: interruptallowed675 -)))| (% style="width:110px" %)0705 +ON: Mask interrupt OFF: Enable interrupt 706 +)))|0 676 676 677 677 == Subroutine == 678 678