Changes for page 01 Program execution

Last modified by Jiahao Lai on 2025/07/18 17:39

From version 26.1
edited by Jim(Forgotten)
on 2023/08/08 10:07
Change comment: Added annotation on "manual "
To version 32.1
edited by Mora Zhou
on 2023/11/22 14:09
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Jim
1 +XWiki.Mora
Content
... ... @@ -1,6 +1,6 @@
1 1  = **Summary** =
2 2  
3 -This manual has a comprehensive introduction to the basic functions of WECON PLC Editor and the actual use. This book is completely aimed at zero-based readers, is an essential reference book for entry-level readers to quickly and fully grasp WECON PLC and WECON PLC Editor.
3 +This manual has a comprehensive introduction to the basic functions of WECON PLC Editor and the actual use. This book is completely aimed at zero-based readers, which is an essential reference book for entry-level readers to quickly and fully grasp WECON PLC and WECON PLC Editor.
4 4  
5 5  This book starts from the basic product of WECON PLC and the basic concept and operation of WECON PLC Editor. It combines with a large number of cases and graphic analysis to comprehensively and deeply explain the use of WECON PLC Editor Software, as well as PLC program.
6 6  
... ... @@ -29,8 +29,8 @@
29 29  (((
30 30  **✎Note:**
31 31  
32 -* To prevent the temperature from rising, do not install at the bottom, top or vertical direction.Be sure to install it horizontally on the wall as shown on the right.
33 -* Please leave a space of more than 50mm between the host and other equipment or structures.Try to avoid high-voltage lines, high-voltage equipment, and power equipment.
32 +* To prevent the temperature from rising, do not install at the bottom, top or vertical direction. Be sure to install it horizontally on the wall as shown on the right.
33 +* Please leave a space of more than 50mm between the host and other equipment or structures. Try to avoid high-voltage lines, high-voltage equipment, and power equipment.
34 34  )))
35 35  
36 36  == Wiring ==
... ... @@ -434,7 +434,7 @@
434 434  [[image:1-20.png||class="img-thumbnail"]]
435 435  
436 436  (% class="table-bordered" %)
437 -|(% colspan="2" %)**Project**|**Content**|**Setting range**|**Default**
437 +|=(% colspan="2" %)**Project**|=**Content**|=**Setting range**|=**Default**
438 438  |(% colspan="2" %)Execution type|Select the type of interrupt|Not set/External input interrupt/Timer event/high-speed counter interrupt|Not set
439 439  |(% rowspan="2" %)Timer interrupt|Time|Set the interval time for interrupt triggering|1 to 2147483647 (100us unit)|
440 440  |priority|When multiple interrupts arrive at the same time, the order of priority execution, the smallest value is executed first|0 to 2|0
... ... @@ -472,7 +472,7 @@
472 472  [[image:1-23.png||class="img-thumbnail"]]
473 473  
474 474  (% class="table-bordered" %)
475 -|(% colspan="2" %)**Project**|**Content**|**Setting range**|**Default**
475 +|=(% colspan="2" %)**Project**|=**Content**|=**Setting range**|=**Default**
476 476  |(% colspan="2" %)Execution type|Select the type of interrupt|Not set, External input interrupt, Timer event, high-speed counter interrupt|Not set
477 477  |(% rowspan="5" %)High count interrupt|Mode|(((
478 478  Select the type of high-speed counter interrupt:
... ... @@ -503,7 +503,7 @@
503 503   Description of triggering rules
504 504  
505 505  (% class="table-bordered" %)
506 -|(% style="width:135px" %)**Mode**|(% style="width:187px" %)**Configuration**|(% style="width:128px" %)**The current value**|(% style="width:324px" %)**Action**
506 +|=(% style="width: 135px;" %)**Mode**|=(% style="width: 187px;" %)**Configuration**|=(% style="width: 128px;" %)**The current value**|=(% style="width: 324px;" %)**Action**
507 507  |(% rowspan="2" style="width:135px" %)High-speed compare interrupt (INT0)|(% rowspan="2" style="width:187px" %)Comparison value: 10000|(% style="width:128px" %)9999 → 10000|(% style="width:324px" %)Execute all programs in interrupt INT0
508 508  |(% style="width:128px" %)10001 → 10000|(% style="width:324px" %)Execute all programs in interrupt INT0
509 509  |(% rowspan="2" style="width:135px" %)High-speed comparison set (INT1)|(% rowspan="2" style="width:187px" %)(((
XWiki.XWikiComments[0]
Author
... ... @@ -1,1 +1,0 @@
1 -xwiki:XWiki.Jim
Comment
... ... @@ -1,1 +1,0 @@
1 -54
Date
... ... @@ -1,1 +1,0 @@
1 -2023-08-08 10:07:53.526
Selection
... ... @@ -1,1 +1,0 @@
1 -manual
Selection Left Context
... ... @@ -1,1 +1,0 @@
1 -This
Selection Right Context
... ... @@ -1,1 +1,0 @@
1 -has a comprehensive introduction to the basic functions of WECON PLC Editor and the actual use. This book is completely aimed at zero-based readers, is an essential reference book for entry-level readers to quickly and fully grasp WECON PLC and WECON PLC Editor. 
State
... ... @@ -1,1 +1,0 @@
1 -SAFE
Target
... ... @@ -1,1 +1,0 @@
1 -PLC Editor2.01 Program execution.WebHome