Changes for page 01 Program execution
Last modified by Jiahao Lai on 2025/07/18 17:39
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Jim1 +XWiki.Mora - Content
-
... ... @@ -1,27 +1,24 @@ 1 1 = **Summary** = 2 2 3 -This manual has a comprehensive introduction to the basic functions of WECON PLC Editor and the actual use. This book is completely aimed at zero-based readers, is an essential reference book for entry-level readers to quickly and fully grasp WECON PLC and WECON PLC Editor. 3 +This manual provides a comprehensive introduction to the basic functions and actual use of WECON PLC Editor. It is completely aimed at zero-based readers and is an essential reference book for entry-level readers who want to quickly and fully grasp WECON PLC and WECON PLC Editor. 4 +This book starts with the basic product of WECON PLC and the basic concept and operation of WECON PLC Editor. It then uses a large number of cases and graphic analysis to comprehensively and deeply explain the use of WECON PLC Editor Software and the PLC program. 5 +WECON Technology Co., Ltd. All rights reserved. 4 4 5 -This book starts from the basic product of WECON PLC and the basic concept and operation of WECON PLC Editor. It combines with a large number of cases and graphic analysis to comprehensively and deeply explain the use of WECON PLC Editor Software, as well as PLC program. 6 - 7 -WECON technology Co., Ltd. All rights reserved. 8 - 9 9 = Precautions = 10 10 11 -Before the installation, operation, maintenance and repair of the micro programmable control, please read this manual and other related manuals to ensure correct use. Please use it after you have mastered the operation method, safety information and all9 +Before the installation, operation, maintenance and repair of the micro programmable control, please read this manual and other related manuals to ensure correct use. Please use it after you have mastered the operation method, and safety information. 12 12 13 13 == Design == 14 14 15 -In the event of an abnormality in the external power supply or failure of the programmable controller, to ensure the safe operation of the entire system, be sure to install a safety circuit outside the programmable controller. 16 16 17 17 1. Be sure to install an emergency brake circuit, a protection circuit, an interlock circuit for reverse operation, such as an emergency brake circuit, a protection circuit, a forward and reverse circuit, and an interlock circuit for the upper and lower positioning limits to prevent machine damage, in the external circuit of the programmable controller. 18 -1. When the programmable controller CPU detects abnormal conditions such as WDT errors through self-diagnosis, all outputs are shut off. In addition, when the programmable controller CPU cannot detect abnormalities in the input/output control part, etc., it cannot control the output. At this time, in order to make the machine operate safely, please design the external circuit and mechanism.19 -1. Due to the failure of the relay and transistor of the output unit, it is impossible to control the state of the output to ON or OFF. Inordertoensure the safe operation of the machine, please design external circuits and mechanisms for output signals related to major accidents.15 +1. When the programmable controller CPU detects abnormal conditions such as WDT errors through self-diagnosis, all outputs are shut off. In addition, when the programmable controller CPU cannot detect abnormalities in the input/output control part, etc., it cannot control the output. At this time, please design the external circuit and mechanism so that the machine can operate safely. 16 +1. Due to the failure of the relay and transistor of the output unit, it is impossible to control the state of the output to ON or OFF. To ensure the safe operation of the machine, please design external circuits and mechanisms for output signals related to major accidents. 20 20 21 21 == Installation == 22 22 23 23 * Please use it in the general specification environment described in the manual. 24 -** Do not use in the following places: places with dust, oily smoke, conductive dust, corrosive gas, flammable gas; places 21 +** Do not use in the following places: places with dust, oily smoke, conductive dust, corrosive gas, or flammable gas; places exposed to high temperature, condensation, wind, and rain; places with vibration or impact. Electric shock, fire, and misoperation can also cause product damage. 25 25 * When processing screw holes and wiring, do not let iron filings or wire ends fall into the ventilation window of the programmable controller. It may cause fire, malfunction, or misoperation. 26 26 * Please insert the connecting cable and display module accurately into the specified sockets. Poor contact may cause misoperation. 27 27 ... ... @@ -29,8 +29,8 @@ 29 29 ((( 30 30 **✎Note:** 31 31 32 -* To prevent the temperature from rising, do not install at the bottom, top or vertical direction.Be sure to install it horizontally on the wall as shown on the right. 33 -* Please leave a space of more than 50mm between the host and other equipment or structures.Try to avoid high-voltage lines, high-voltage equipment, and power equipment. 29 +* To prevent the temperature from rising, do not install at the bottom, top or vertical direction. Be sure to install it horizontally on the wall as shown on the right. 30 +* Please leave a space of more than 50mm between the host and other equipment or structures. Try to avoid high-voltage lines, high-voltage equipment, and power equipment. 34 34 ))) 35 35 36 36 == Wiring == ... ... @@ -74,7 +74,7 @@ 74 74 75 75 * Please connect the AC power supply to the dedicated terminal according to the content in the manual. 76 76 * If the AC power supply is connected to the DC input/output terminal or the DC power supply terminal, the programmable controller will be burnt out. 77 -* Please do not supply power to the 24+ terminal of the basic unit from the external power supply ,and to the empty terminal74 +* Please do not supply power to the 24+ terminal of the basic unit from the external power supply and to the empty terminal. Do not wire from the outside, otherwise the product will be damaged. 78 78 * Please ground the ground terminal of the basic unit according to the third method. But please do not share the ground with the strong current system. 79 79 80 80 **Attached** ... ... @@ -111,12 +111,12 @@ 111 111 112 112 Regular inspection: Whether the programmable controller is equipped with consumables with a shorter life. 113 113 114 -For relay output type, if the output relay works abnormally at a high frequency or drives a large-capacity load, you must pay attention to its impact on the service life. 111 +For the relay output type, if the output relay works abnormally at a high frequency or drives a large-capacity load, you must pay attention to its impact on the service life. 115 115 116 116 Check with other equipment, please pay attention to the following points: 117 117 118 118 * Whether there is an abnormal increase in the temperature inside the machine due to other heating elements or direct sunlight. 119 -* Whether dust or conductive dust has penetrated into the machine.116 +* Whether dust or conductive dust has penetrated the machine. 120 120 * Whether there are loose wiring and terminals or other abnormalities 121 121 122 122 = Scan structure = ... ... @@ -434,7 +434,7 @@ 434 434 [[image:1-20.png||class="img-thumbnail"]] 435 435 436 436 (% class="table-bordered" %) 437 -|(% colspan="2" %)**Project**|**Content**|**Setting range**|**Default** 434 +|=(% colspan="2" %)**Project**|=**Content**|=**Setting range**|=**Default** 438 438 |(% colspan="2" %)Execution type|Select the type of interrupt|Not set/External input interrupt/Timer event/high-speed counter interrupt|Not set 439 439 |(% rowspan="2" %)Timer interrupt|Time|Set the interval time for interrupt triggering|1 to 2147483647 (100us unit)| 440 440 |priority|When multiple interrupts arrive at the same time, the order of priority execution, the smallest value is executed first|0 to 2|0 ... ... @@ -472,7 +472,7 @@ 472 472 [[image:1-23.png||class="img-thumbnail"]] 473 473 474 474 (% class="table-bordered" %) 475 -|(% colspan="2" %)**Project**|**Content**|**Setting range**|**Default** 472 +|=(% colspan="2" %)**Project**|=**Content**|=**Setting range**|=**Default** 476 476 |(% colspan="2" %)Execution type|Select the type of interrupt|Not set, External input interrupt, Timer event, high-speed counter interrupt|Not set 477 477 |(% rowspan="5" %)High count interrupt|Mode|((( 478 478 Select the type of high-speed counter interrupt: ... ... @@ -503,7 +503,7 @@ 503 503 Description of triggering rules 504 504 505 505 (% class="table-bordered" %) 506 -|(% style="width:135px" %)**Mode**|(% style="width:187px" %)**Configuration**|(% style="width:128px" %)**The current value**|(% style="width:324px" %)**Action** 503 +|=(% style="width: 135px;" %)**Mode**|=(% style="width: 187px;" %)**Configuration**|=(% style="width: 128px;" %)**The current value**|=(% style="width: 324px;" %)**Action** 507 507 |(% rowspan="2" style="width:135px" %)High-speed compare interrupt (INT0)|(% rowspan="2" style="width:187px" %)Comparison value: 10000|(% style="width:128px" %)9999 → 10000|(% style="width:324px" %)Execute all programs in interrupt INT0 508 508 |(% style="width:128px" %)10001 → 10000|(% style="width:324px" %)Execute all programs in interrupt INT0 509 509 |(% rowspan="2" style="width:135px" %)High-speed comparison set (INT1)|(% rowspan="2" style="width:187px" %)(((