Changes for page 01 Program execution
Last modified by Jiahao Lai on 2025/07/18 17:39
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Mora1 +XWiki.Jim - Content
-
... ... @@ -1,6 +1,6 @@ 1 1 = **Summary** = 2 2 3 -This manual has a comprehensive introduction to the basic functions of WECON PLC Editor and the actual use. This book is completely aimed at zero-based readers, which is an essential reference book for entry-level readers to quickly and fully grasp WECON PLC and WECON PLC Editor.3 +This manual has a comprehensive introduction to the basic functions of WECON PLC Editor and the actual use. This book is completely aimed at zero-based readers, is an essential reference book for entry-level readers to quickly and fully grasp WECON PLC and WECON PLC Editor. 4 4 5 5 This book starts from the basic product of WECON PLC and the basic concept and operation of WECON PLC Editor. It combines with a large number of cases and graphic analysis to comprehensively and deeply explain the use of WECON PLC Editor Software, as well as PLC program. 6 6 ... ... @@ -29,8 +29,8 @@ 29 29 ((( 30 30 **✎Note:** 31 31 32 -* To prevent the temperature from rising, do not install at the bottom, top or vertical direction. 33 -* Please leave a space of more than 50mm between the host and other equipment or structures. 32 +* To prevent the temperature from rising, do not install at the bottom, top or vertical direction.Be sure to install it horizontally on the wall as shown on the right. 33 +* Please leave a space of more than 50mm between the host and other equipment or structures.Try to avoid high-voltage lines, high-voltage equipment, and power equipment. 34 34 ))) 35 35 36 36 == Wiring == ... ... @@ -434,7 +434,7 @@ 434 434 [[image:1-20.png||class="img-thumbnail"]] 435 435 436 436 (% class="table-bordered" %) 437 -| =(% colspan="2" %)**Project**|=**Content**|=**Setting range**|=**Default**437 +|(% colspan="2" %)**Project**|**Content**|**Setting range**|**Default** 438 438 |(% colspan="2" %)Execution type|Select the type of interrupt|Not set/External input interrupt/Timer event/high-speed counter interrupt|Not set 439 439 |(% rowspan="2" %)Timer interrupt|Time|Set the interval time for interrupt triggering|1 to 2147483647 (100us unit)| 440 440 |priority|When multiple interrupts arrive at the same time, the order of priority execution, the smallest value is executed first|0 to 2|0 ... ... @@ -472,7 +472,7 @@ 472 472 [[image:1-23.png||class="img-thumbnail"]] 473 473 474 474 (% class="table-bordered" %) 475 -| =(% colspan="2" %)**Project**|=**Content**|=**Setting range**|=**Default**475 +|(% colspan="2" %)**Project**|**Content**|**Setting range**|**Default** 476 476 |(% colspan="2" %)Execution type|Select the type of interrupt|Not set, External input interrupt, Timer event, high-speed counter interrupt|Not set 477 477 |(% rowspan="5" %)High count interrupt|Mode|((( 478 478 Select the type of high-speed counter interrupt: ... ... @@ -503,7 +503,7 @@ 503 503 Description of triggering rules 504 504 505 505 (% class="table-bordered" %) 506 -| =(% style="width:;" %)**Mode**|=(% style="width:;" %)**Configuration**|=(% style="width:;" %)**The current value**|=(% style="width:;" %)**Action**506 +|(% style="width:135px" %)**Mode**|(% style="width:187px" %)**Configuration**|(% style="width:128px" %)**The current value**|(% style="width:324px" %)**Action** 507 507 |(% rowspan="2" style="width:135px" %)High-speed compare interrupt (INT0)|(% rowspan="2" style="width:187px" %)Comparison value: 10000|(% style="width:128px" %)9999 → 10000|(% style="width:324px" %)Execute all programs in interrupt INT0 508 508 |(% style="width:128px" %)10001 → 10000|(% style="width:324px" %)Execute all programs in interrupt INT0 509 509 |(% rowspan="2" style="width:135px" %)High-speed comparison set (INT1)|(% rowspan="2" style="width:187px" %)(((