Changes for page 02 Devices
Last modified by Mora Zhou on 2023/11/22 14:13
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -02 Registers1 +02 Devices - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PLC Editor2. 2\.1 LX5V user manual.WebHome1 +PLC Editor2.WebHome - Content
-
... ... @@ -1,28 +1,27 @@ 1 -= Registerslist =1 += Device list = 2 2 3 +|=(% scope="row" %)**Classification**|=**Type**|=**Device name**|=**Sign**|=**Range**|=**Number** 4 +|=(% rowspan="10" %)User devices|Bit|Input|X|0 to 1777|Octal number 5 +|(% scope="row" %)Bit|Output|Y|0 to 1777|Octal number 6 +|(% scope="row" %)Bit|Internal relay|M|0 to 7999|Decimal number 7 +|(% scope="row" %)Bit|Step relay|S|0 to 4095|Decimal number 8 +|(% scope="row" %)Bit/word|Timer|T|0 to 511|Decimal number 9 +|(% scope="row" %)Bit/word|Counter|C|0 to 255|Decimal number 10 +|(% scope="row" %)Bit/double word|Long counter|LC|0 to 255|Decimal number 11 +|(% scope="row" %)Bit/double word|High-speed counter|HSC|0 to 15|Decimal number 12 +|(% scope="row" %)Word|Data Register|D|0 to 7999|Decimal number 13 +|(% scope="row" %)Word|Data Register|R|0 to 29999|Decimal number 14 +|=(% rowspan="2" %)System devices|Bit|Special|SM|0 to 4095|Decimal number 15 +|(% scope="row" %)Word|Special register|SD|0 to 4095|Decimal number 16 +|=(% rowspan="3" %)Index registers|Word|Index register|[D]|0 to 7999|Decimal number 17 +|(% scope="row" %)Word|Index register|V|0 to 7|Decimal number 18 +|(% scope="row" %)Double word|Long index register|Z|0 to 7|Decimal number 19 +|=Nested|Bit|Nested|N|0 to 7|Decimal number 20 +|=Pointer|-|Pointer|P|0 to 4095|Decimal number 21 +|=(% rowspan="3" %)Constant|-|Decimal constant|K|-|Decimal number 22 +|(% scope="row" %)-|Hexadecimal constant|H|-|Hexadecimal number 23 +|(% scope="row" %)Single precision floating point|Real constant|E|-|- 3 3 4 -|**Classification**|**Length**|**Description**|**Register**|**Range**|**Number** 5 -|(% rowspan="10" %)User registers|Bit|Input|X|0 to 1777|Octal number 6 -|Bit|Output|Y|0 to 1777|Octal number 7 -|Bit|Internal relay|M|0 to 7999|Decimal number 8 -|Bit|Step relay|S|0 to 4095|Decimal number 9 -|Bit/word|Timer|T|0 to 511|Decimal number 10 -|Bit/word|Counter|C|0 to 255|Decimal number 11 -|Bit/double word|Long counter|LC|0 to 255|Decimal number 12 -|Bit/double word|High-speed counter|HSC|0 to 15|Decimal number 13 -|Word|Data Register|D|0 to 7999|Decimal number 14 -|Word|Data Register|R|0 to 29999|Decimal number 15 -|(% rowspan="2" %)System registers|Bit|Special|SM|0 to 4095|Decimal number 16 -|Word|Special register|SD|0 to 4095|Decimal number 17 -|(% rowspan="3" %)Index registers|Word|Index register|[D]|0 to 7999|Decimal number 18 -|Word|Index register|V|0 to 7|Decimal number 19 -|Double word|Long index register|Z|0 to 7|Decimal number 20 -|Nested|Bit|Nested|N|0 to 7|Decimal number 21 -|Pointer|-|Pointer|P|0 to 4095|Decimal number 22 -|(% rowspan="3" %)Constant|-|Decimal constant|K|-|Decimal number 23 -|-|Hexadecimal constant|H|-|Hexadecimal number 24 -|Single precision floating point|Real constant|E|-|- 25 - 26 26 = User registers = 27 27 28 28 == Input relay (X) == ... ... @@ -145,13 +145,13 @@ 145 145 146 146 The special relay SM is an internal relay with a certain specification inside the programmable controller, so it cannot be used in the program like ordinary internal relays. It can be turned ON/OFF as needed to control the PLC. 147 147 148 -For details, please refer to [[(% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)__Special relays (SM) list__>>path:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/ 2.1%20LX5V%20user%20manual/15/#HAttachment1SpecialRelay28SM29]](%%).147 +For details, please refer to [[(% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)__Special relays (SM) list__>>path:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HAppendix1SpecialRelay28SM29]](%%). 149 149 150 150 == Special Register (SD) == 151 151 152 152 The special register SD is an internal register whose specifications are determined within the programmable controller, so it cannot be used in the program like a normal internal register, and the corresponding data can be written as needed to control the PLC. 153 153 154 -For details, please refer to [[(% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)__Special register (SD) list__>>path:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/ 2.1%20LX5V%20user%20manual/15/#HAppendix2SpecialRegister28SD29]](%%).153 +For details, please refer to [[(% class="wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink wikiinternallink" %)__Special register (SD) list__>>path:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HAppendix2SpecialRegister28SD29]](%%). 155 155 156 156 = Index Register = 157 157