Changes for page 17 LX3V/5V/5S comparsion

Last modified by Jim on 2025/02/11 11:34

From version 10.1
edited by Leo Wei
on 2022/06/14 15:29
Change comment: There is no comment for this version
To version 2.1
edited by Jim
on 2022/06/14 14:48
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -03 Difference between 3V, 5V and 5S
1 +Difference between 3V, 5V and 5S
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.admin
1 +XWiki.Jim
Content
... ... @@ -1,63 +1,7 @@
1 -= **1 Basic difference between 3V, 5V and 5S** =
1 += **1.** **Functions that 3V has but 5V does not** =
2 2  
3 -|=(% scope="row" %)Functions|=5V|=5S|=3V
4 -|=Running Mode|(% colspan="3" %)Cyclic scan /Interrupt
5 -|=Power supply|(% colspan="3" %)A:AC 220V;D:DC 24V
6 -|=Output type|MT:Transistor|MT:Transistor;MR:Relay|MT:Transistor;MR:Relay
7 -|=I/O|1212;1412;1616;2416;2424;3624;|0806;1208;1212;1412;
8 -1616;2416;2424;3624;|0806;1208;1212;1412;
9 -1616;2416;2424;3624;
10 -|=Programming|(% colspan="3" %)Ladder
11 -|=Type of instruction| | |
12 -|=Execute Time|Basic 0.01-0.03μs|Basic 0.03-0.08μs|Basic 0.06μs/Applied instruction:1-10us
13 -|=Program Capacity|(% colspan="2" %)512KB|16k
14 -|=High Speed Pulse Output|≤1412MT and smaller: 4*200KHz;
15 -≥1616MT and bigger:  8*200KHz。|MT/MR2H: 2* 200KHz;
16 -MT4H: 4* 200KHz。|MT/2H: 2*100KHZ, or 4H: 4*100, single: 200kHZ
17 -|=High speed counter Interrupt|(% colspan="2" %)100 channels|21channels
18 -|=Timer Interrupt|(% colspan="2" %)100 channels,Support 0.1ms Interrupt|95 channels
19 -|=X Interrupt|X0-X7 Rising & Falling|X0-X5 Rising & Falling|X0-X5 Rising & Falling
20 -|=**High speed counter Single Phase**|**≤1412 and smaller: 4*150KHz
21 -≥1616 and bigger: 8*150KHz**|**≤1412 and smaller: 2*150KHz;4*10KHz
22 -≥1616 and bigger: 6*150KHz**|**2*200KHz; 4*10KHz**
23 -|=**High speed counter AB phase**|**≤1412 and smaller: 4*100KHz
24 -≥1616 and bigger: 8*100KHz**|**≤1412 and smaller: 1*100KHz+2*10KHz
25 -≥1616 and bigger: 3*100KHz**|**2*100KHz**
26 -|=Storage Type|(% colspan="3" %)FLASH
27 -|=Serial Communication|(((
28 -COM1: RS422、RS485;COM2: RS485
29 -)))|1208 and smaller: COM1: RS422;COM2: RS485;
30 -1212 and bigger: COM1: RS422、RS485;COM2:RS485|1208 and smaller: COM1: RS422;COM2: RS485;
31 -1212 and bigger: COM1: RS422、RS485;COM2: RS485
32 -|=BD board support|yes|yes|yes
33 -|=Communication BD board|(% colspan="2" %)inbuilt ethernet port series, RS485 BD board in developing |RS485 BD support, 3vp supports ethernet bd board
34 -|=Expansion Module|(% colspan="2" %)yes √ (1212 and bigger can support)|yes √ (1212 and bigger can support)
35 -|=Electronic CAM|√(2 sheets for switch)|√(2 sheets for switch)|N/A
36 -|=S-type CAM|√|√|N/A
37 -|=N:N Comm|√|√|N/A
38 -|=Linear Interpolation|√|√|N/A
39 -|=Circular Interpolation|√|√|N/A
40 -|=sub-rotine|√|√|N/A
41 -|= | | |
3 +== **1.1 BD board** ==
42 42  
43 -= **2 Software interface difference between 5S and 5V** =
44 -
45 -== **2.1 High speed counter configuration** ==
46 -
47 -**5V as below**
48 -
49 -[[image:image-20220614151005-1.png]]
50 -
51 -**5S is as below**
52 -
53 -[[image:image-20220614151015-2.png]]
54 -
55 -**More detail information,please check the product catalog**
56 -
57 -= **3** **Functions that 3V has but 5V does not** =
58 -
59 -== **3.1 BD board** ==
60 -
61 61  LX5V does not support RS485 BD
62 62  
63 63  LX5V does not support Ethernet BD
... ... @@ -64,15 +64,15 @@
64 64  
65 65  LX5V does not support CAN BD
66 66  
67 -== **3.2 Analog BD board expansion address** ==
11 +== **1.2 Analog BD board expansion address** ==
68 68  
69 69  Provides the function of analog board BD to modify parameters such as filtering. For specific functions, please refer to the BD board manual.
70 70  
71 -== **3.3 PLDID** ==
15 +== **1.3 PLDID** ==
72 72  
73 73  Program label function, when the label of the program corresponds to the label of the PLC, the ladder diagram can be uploaded and downloaded. Clearing the memory does not clear this tag either. It is mainly to limit the ladder diagram used by PLC.
74 74  
75 -== **3.4 Instructions** ==
19 +== **1.4 Instructions** ==
76 76  
77 77  (1) NOP instruction (null instruction)
78 78  
... ... @@ -96,58 +96,61 @@
96 96  
97 97  (11) CPAVL instruction(communication BD configuration)
98 98  
99 -== **3.5 Unsupported special register function (M8000, D8000)** ==
43 +== **1.5 Unsupported special register function (M8000, D8000)** ==
100 100  
101 -=== **3.5.1 Clock related** ===
45 +=== **1.5.1 Clock related** ===
102 102  
103 103  Clock function not supported by LX5V
104 104  
105 -|=M8014|Oscillation clock with 1 minute clock period
106 -|=M8015|Clock stop and preset
107 -|=M8016|Stop time to read the display
108 -|=M8017|±30 seconds correction
109 -|=M8018|install and examine
110 -|=M8019|Real-time clock (RTC) error
49 +(% class="table-bordered" %)
50 +|M8014|Oscillation clock with 1 minute clock period
51 +|M8015|Clock stop and preset
52 +|M8016|Stop time to read the display
53 +|M8017|±30 seconds correction
54 +|M8018|install and examine
55 +|M8019|Real-time clock (RTC) error
111 111  
112 -=== **3.5.2 High-speed counter ring counting function** ===
57 +=== **1.5.2 High-speed counter ring counting function** ===
113 113  
114 -|=M8099|High-speed ring counter count start
115 -|=M8099|Ring count configuration
59 +(% class="table-bordered" %)
60 +|M8099|High-speed ring counter count start
61 +|M8099|Ring count configuration
116 116  
117 -=== **3.5.3 X0~~X5 pulse capture function** ===
63 +=== **1.5.3 X0~~X5 pulse capture function** ===
118 118  
119 -|=M8170|X000 pulse capture
120 -|=M8171|X001 pulse capture
121 -|=M8172|X002 pulse capture
122 -|=M8173|X003 pulse capture
123 -|=M8174|X004 pulse capture
124 -|=M8175|X005 pulse capture
65 +(% class="table-bordered" %)
66 +|M8170|X000 pulse capture
67 +|M8171|X001 pulse capture
68 +|M8172|X002 pulse capture
69 +|M8173|X003 pulse capture
70 +|M8174|X004 pulse capture
71 +|M8175|X005 pulse capture
125 125  
126 -= **4. 5V function under development** =
73 += **2. 5V function under development** =
127 127  
128 128  N:N communication protocol
129 129  
130 130  Interpolation instructions (G90G01, G90G02, G90G03, G91G01, G91G02, G91G03)
131 131  
132 -= **5. 3V and 5V incompatible functions (These can be automatically converted in the future)** =
79 += **3. 3V and 5V incompatible functions (These can be automatically converted in the future)** =
133 133  
134 -== **5.1 General register** ==
81 +== **3.1 General register** ==
135 135  
136 136  (% class="table-bordered" %)
137 -|=(% scope="row" %)**register**|=**LX3V**|=**LX5V**|=**Remarks**
138 -|=Input|X0~~X377|X0~~X1777|
139 -|=Output|Y0~~Y377|Y0~~Y1777|
140 -|=Auxiliary|M0~~M3071|M0~~M7999|
141 -|=Status|S0~~S999|S0~~S4095|
142 -|=Timer|T0~~T255|T0~~T511|
143 -|=counter|C0~~C199|C0~~C255|
144 -|=Double word counter|C200~~C219|LC0~~LC99|Non-power-down save
145 -|=Double word counter|C220~~C234|LC100~~LC255|Power-down save
146 -|=High-speed counter|C235~~C255|HSC0~~HSC7|Check the high-speed input function
147 -|=Data Register|D0~~D7999|D0~~D7999 (R0~~R29999)|
148 -|=Pointer P|P0~~P127|P0~~P4095|
149 -|=Instruction I|I0~~I8xx|None|
150 -|=constant|K, H, E|K, H, E|
84 +|**register**|**LX3V**|**LX5V**|**Remarks**
85 +|Input|X0~~X377|X0~~X1777|
86 +|Output|Y0~~Y377|Y0~~Y1777|
87 +|Auxiliary|M0~~M3071|M0~~M7999|
88 +|Status|S0~~S999|S0~~S4095|
89 +|Timer|T0~~T255|T0~~T511|
90 +|counter|C0~~C199|C0~~C255|
91 +|Double word counter|C200~~C219|LC0~~LC99|Non-power-down save
92 +|Double word counter|C220~~C234|LC100~~LC255|Power-down save
93 +|High-speed counter|C235~~C255|HSC0~~HSC7|Check the high-speed input function
94 +|Data Register|D0~~D7999|D0~~D7999 (R0~~R29999)|
95 +|Pointer P|P0~~P127|P0~~P4095|
96 +|Instruction I|I0~~I8xx|None|
97 +|constant|K, H, E|K, H, E|
151 151  
152 152  **Incompatible part**
153 153  
... ... @@ -161,9 +161,9 @@
161 161  
162 162  5. Pointer I is cancelled in LX5V, please check the programming mode for details.
163 163  
164 -== **5.2 Programming method** ==
111 +== **3.2 Programming method** ==
165 165  
166 -=== **5.2.1 Subroutine (For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)** ===
113 +=== **3.2.1 Subroutine (For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)** ===
167 167  
168 168  **Use of LX3V subroutines**
169 169  [[image:1652684087594-147.png]]
... ... @@ -178,7 +178,7 @@
178 178  
179 179  [[image:1652684829740-769.png]]
180 180  
181 -=== **5.2.2 Interrupt (For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)** ===
128 +=== **3.2.2 Interrupt (For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)** ===
182 182  
183 183  **LX3V interrupt**
184 184  
... ... @@ -198,7 +198,7 @@
198 198  
199 199  [[image:1652685809566-630.png]]
200 200  
201 -=== **5.2.3 Instructions** ===
148 +=== **3.2.3 Instructions** ===
202 202  
203 203  **OUT command**
204 204  
... ... @@ -266,9 +266,9 @@
266 266  
267 267  [[image:1652689626279-240.png]]
268 268  
269 -= **6. High-speed input function** =
216 += **4. High-speed input function** =
270 270  
271 -== **6.1 Use on LX3V** ==
218 +== **4.1 Use on LX3V** ==
272 272  
273 273  Find the high-speed input counter you need to use according to the following table:
274 274  
... ... @@ -280,7 +280,7 @@
280 280  
281 281  [[image:1652690126303-800.png]]
282 282  
283 -== **6.2 Use on LX5V** ==
230 +== **4.2 Use on LX5V** ==
284 284  
285 285  According to channel, select the HSC register to use:
286 286  
... ... @@ -294,7 +294,7 @@
294 294  
295 295  [[image:1652692388207-617.png]]
296 296  
297 -== **6.3 Difference between high-speed counters on LX5V and LX3V** ==
244 +== **4.3 Difference between high-speed counters on LX5V and LX3V** ==
298 298  
299 299  LX3V updates the count value when the OUT instruction is executed, which is affected by the scan cycle.
300 300  
... ... @@ -305,20 +305,20 @@
305 305  
306 306  LX5V high-speed input counter will update the input frequency in the special soft element (SD) every 100us.
307 307  
308 -= **7. High-speed output function** =
255 += **5. High-speed output function** =
309 309  
310 310  **High-speed pulse commands are the same in the use of commands.**
311 311  
312 312  (% class="table-bordered" %)
313 -|=(% scope="row" %) |=LX3V|=LX5V
314 -|=DRVI|√|√
315 -|=DRVA|√|√
316 -|=PLSR|√|√
317 -|=PLSV|√|√
318 -|=PLSY|√|√
319 -|=DVIT|√|√
320 -|=ZRN|√|√
321 -|=PLSR2|√|√
260 +| |LX3V|LX5V
261 +|DRVI|√|√
262 +|DRVA|√|√
263 +|PLSR|√|√
264 +|PLSV|√|√
265 +|PLSY|√|√
266 +|DVIT|√|√
267 +|ZRN|√|√
268 +|PLSR2|√|√
322 322  
323 323  **High-speed pulse command difference.**
324 324  
... ... @@ -331,16 +331,16 @@
331 331  2. Comparison of bit devices
332 332  
333 333  (% class="table-bordered" %)
334 -|=(% scope="row" %)**3V**|=**Description**|=**5V**|=**Description**
335 -|=M8145|Y000 pulse output stop|SM898|Y000 pulse output stop
336 -|=M8146|Y001 Pulse output stop|SM958|Y001 Pulse output stop
337 -|=M8152|Y002 pulse output stop|SM1018|Y002 pulse output stop
338 -|=M8153|Y003 Pulse output stop|SM1078|Y003 Pulse output stop
339 -|=M8147|Y000 monitoring during pulse output|SM880|Y000 monitoring during pulse output
340 -|=M8148|Y001 Monitoring during pulse output|SM940|Y001 Monitoring during pulse output
341 -|=M8149|Y002 Monitoring during pulse output|SM1000|Y002 Monitoring during pulse output
342 -|=M8150|Y003 Monitoring during pulse output|SM1060|Y003 Monitoring during pulse output
343 -|=(% rowspan="4" %)(((
281 +|**3V**|**Description**|**5V**|**Description**
282 +|M8145|Y000 pulse output stop|SM898|Y000 pulse output stop
283 +|M8146|Y001 Pulse output stop|SM958|Y001 Pulse output stop
284 +|M8152|Y002 pulse output stop|SM1018|Y002 pulse output stop
285 +|M8153|Y003 Pulse output stop|SM1078|Y003 Pulse output stop
286 +|M8147|Y000 monitoring during pulse output|SM880|Y000 monitoring during pulse output
287 +|M8148|Y001 Monitoring during pulse output|SM940|Y001 Monitoring during pulse output
288 +|M8149|Y002 Monitoring during pulse output|SM1000|Y002 Monitoring during pulse output
289 +|M8150|Y003 Monitoring during pulse output|SM1060|Y003 Monitoring during pulse output
290 +|(% rowspan="4" %)(((
344 344  
345 345  
346 346  
... ... @@ -350,35 +350,35 @@
350 350  
351 351  Some instructions (PLSR, etc.) instruction execution completed (Y0-Y3)
352 352  )))|SM882|Y0 pulse sending completed
353 -|=SM942|Y1 pulse sending completed
354 -|=SM1002|Y2 pulse transmission completed
355 -|=SM1062|Y3 pulse transmission completed
356 -|=M8134|Y0's thousandth control bit|SM897|Y0's thousandth control bit
357 -|=M8135|(((
300 +|SM942|Y1 pulse sending completed
301 +|SM1002|Y2 pulse transmission completed
302 +|SM1062|Y3 pulse transmission completed
303 +|M8134|Y0's thousandth control bit|SM897|Y0's thousandth control bit
304 +|M8135|(((
358 358  The acceleration and deceleration time between each axis of Y1's thousandth control position positioning command is separated
359 359  )))|(((
360 360  SM957
361 361  )))|Y1 Perimeter control bit
362 -|=M8136|Y2 Perimeter control bit|SM1017|Y2 Perimeter control bit
363 -|=M8137|Y3 Perimeter control bit|SM1077|Y3 Perimeter control bit
309 +|M8136|Y2 Perimeter control bit|SM1017|Y2 Perimeter control bit
310 +|M8137|Y3 Perimeter control bit|SM1077|Y3 Perimeter control bit
364 364  
365 365  3. Comparison of word devices
366 366  
367 367  (% class="table-bordered" %)
368 -|=(% scope="row" %)**3V**|=**Description**|=**5V**|=**Description**
369 -|=D8104|Y0 acceleration and deceleration time (open M8135)|SD902/SD962|Y0 acceleration/deceleration time
370 -|=D8105|Y1 acceleration and deceleration time (open M8135)|SD1022/SD1082|Y1 acceleration/deceleration time
371 -|=D8106|Y2 acceleration and deceleration time (open M8135)|SD1142/SD1202|Y2 acceleration/deceleration time
372 -|=D8107|Y3 acceleration and deceleration time (open M8135)|SD1262/SD1322|Y3 acceleration/deceleration time
373 -|=D8140|Y000 Current position low|SD880|Y000 Current position low
374 -|=D8141|Y000 current position high|SD881|Y000 current position high
375 -|=D8142|Y001 Current position low|SD940|Y001 Current position low
376 -|=D8143|Y001 Current position high|SD941|Y001 Current position high
377 -|=D8150|Y002 current position low|SD1000|Y002 current position low
378 -|=D8151|Y002 current position high|SD1001|Y002 current position high
379 -|=D8152|Y003 Current position low|SD1060|Y003 Current position low
380 -|=D8153|Y003 Current position high|SD1061|Y003 Current position high
381 -|=(% rowspan="4" %)(((
315 +|**3V**|**Description**|**5V**|**Description**
316 +|D8104|Y0 acceleration and deceleration time (open M8135)|SD902/SD962|Y0 acceleration/deceleration time
317 +|D8105|Y1 acceleration and deceleration time (open M8135)|SD1022/SD1082|Y1 acceleration/deceleration time
318 +|D8106|Y2 acceleration and deceleration time (open M8135)|SD1142/SD1202|Y2 acceleration/deceleration time
319 +|D8107|Y3 acceleration and deceleration time (open M8135)|SD1262/SD1322|Y3 acceleration/deceleration time
320 +|D8140|Y000 Current position low|SD880|Y000 Current position low
321 +|D8141|Y000 current position high|SD881|Y000 current position high
322 +|D8142|Y001 Current position low|SD940|Y001 Current position low
323 +|D8143|Y001 Current position high|SD941|Y001 Current position high
324 +|D8150|Y002 current position low|SD1000|Y002 current position low
325 +|D8151|Y002 current position high|SD1001|Y002 current position high
326 +|D8152|Y003 Current position low|SD1060|Y003 Current position low
327 +|D8153|Y003 Current position high|SD1061|Y003 Current position high
328 +|(% rowspan="4" %)(((
382 382  
383 383  
384 384  
... ... @@ -389,10 +389,10 @@
389 389  
390 390  Y0-Y3 Paranoid speed (single word)
391 391  )))|SD900, SD901|Y0 Paranoid speed (double word)
392 -|=SD960, SD961|Y1 Paranoid speed (double word)
393 -|=SD1020, SD1021|Y2 Paranoid speed (double word)
394 -|=SD1080, SD1081|Y3 Paranoid speed (double word)
395 -|=(% rowspan="8" %)(((
339 +|SD960, SD961|Y1 Paranoid speed (double word)
340 +|SD1020, SD1021|Y2 Paranoid speed (double word)
341 +|SD1080, SD1081|Y3 Paranoid speed (double word)
342 +|(% rowspan="8" %)(((
396 396  
397 397  
398 398  
... ... @@ -407,14 +407,14 @@
407 407  
408 408  Y0-Y3 maximum frequency (double word)
409 409  )))|SD898|Y0 Maximum speed low
410 -|=SD899|Y0 Highest speed
411 -|=SD958|Y1 Maximum speed low
412 -|=SD959|Y1 Highest speed
413 -|=SD1018|Y2 Maximum speed low
414 -|=SD1019|Y2 Highest speed
415 -|=SD1078|Y3 Maximum speed low
416 -|=SD1079|Y3 Highest speed
417 -|=(% rowspan="4" %)(((
357 +|SD899|Y0 Highest speed
358 +|SD958|Y1 Maximum speed low
359 +|SD959|Y1 Highest speed
360 +|SD1018|Y2 Maximum speed low
361 +|SD1019|Y2 Highest speed
362 +|SD1078|Y3 Maximum speed low
363 +|SD1079|Y3 Highest speed
364 +|(% rowspan="4" %)(((
418 418  
419 419  
420 420  
... ... @@ -424,9 +424,9 @@
424 424  
425 425  4-axis acceleration/deceleration time (when M8135 is not turned on)
426 426  )))|SD902/SD962|Y0 acceleration/deceleration time
427 -|=SD1022/SD1082|Y1 acceleration/deceleration time
428 -|=SD1142/SD1202|Y2 acceleration/deceleration time
429 -|=SD1262/SD1322|Y3 acceleration/deceleration time
374 +|SD1022/SD1082|Y1 acceleration/deceleration time
375 +|SD1142/SD1202|Y2 acceleration/deceleration time
376 +|SD1262/SD1322|Y3 acceleration/deceleration time
430 430  
431 431   4. New features of high-speed pulse instructions on LX5V
432 432  
... ... @@ -452,7 +452,7 @@
452 452  
453 453  ⑨Support direction reversal (can set the forward direction to low level)
454 454  
455 -= **8. Communication function** =
402 += **6. Communication function** =
456 456  
457 457  **~1. Communication parameter configuration**
458 458  
... ... @@ -463,16 +463,16 @@
463 463  3V settings:
464 464  
465 465  (% class="table-bordered" %)
466 -|=(% scope="row" %)**protocol**|=**D8126 value setting**
467 -|=RS instruction (custom protocol)|00H
468 -|=HMI monitoring protocol (PLC protocol)|01H
469 -|=MODBUS-RTU slave|02H
470 -|=MODBUS-ASCII slave|03H
471 -|=N:N network communication protocol slave|04H
472 -|=RS instruction (custom protocol)|10H
473 -|=MODBUS-RTU master station|20H
474 -|=MODBUS-ASCII master station|30H
475 -|=N:N network communication protocol master station|40H
413 +|**protocol**|**D8126 value setting**
414 +|RS instruction (custom protocol)|00H
415 +|HMI monitoring protocol (PLC protocol)|01H
416 +|MODBUS-RTU slave|02H
417 +|MODBUS-ASCII slave|03H
418 +|N:N network communication protocol slave|04H
419 +|RS instruction (custom protocol)|10H
420 +|MODBUS-RTU master station|20H
421 +|MODBUS-ASCII master station|30H
422 +|N:N network communication protocol master station|40H
476 476  
477 477  5V settings:
478 478  
image-20220614151005-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Jim
Size
... ... @@ -1,1 +1,0 @@
1 -25.3 KB
Content
image-20220614151015-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Jim
Size
... ... @@ -1,1 +1,0 @@
1 -25.3 KB
Content