Changes for page 17 LX3V/5V/5S comparsion

Last modified by Jim on 2025/02/11 11:34

From version 14.1
edited by Leo Wei
on 2022/06/14 15:36
Change comment: There is no comment for this version
To version 15.1
edited by Stone Wu
on 2022/06/17 16:35
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.admin
1 +XWiki.Stone
Content
... ... @@ -41,7 +41,7 @@
41 41  
42 42  = **2 Software interface difference between 5S and 5V** =
43 43  
44 -== **2.1 High speed counter configuration** ==
44 +== **High speed counter configuration** ==
45 45  
46 46  **5V as below**
47 47  
... ... @@ -55,7 +55,7 @@
55 55  
56 56  = **3** **Functions that 3V has but 5V does not** =
57 57  
58 -== **3.1 BD board** ==
58 +== **BD board** ==
59 59  
60 60  LX5V does not support RS485 BD
61 61  
... ... @@ -63,15 +63,15 @@
63 63  
64 64  LX5V does not support CAN BD
65 65  
66 -== **3.2 Analog BD board expansion address** ==
66 +== **Analog BD board expansion address** ==
67 67  
68 68  Provides the function of analog board BD to modify parameters such as filtering. For specific functions, please refer to the BD board manual.
69 69  
70 -== **3.3 PLDID** ==
70 +== **PLDID** ==
71 71  
72 72  Program label function, when the label of the program corresponds to the label of the PLC, the ladder diagram can be uploaded and downloaded. Clearing the memory does not clear this tag either. It is mainly to limit the ladder diagram used by PLC.
73 73  
74 -== **3.4 Instructions** ==
74 +== **Instructions** ==
75 75  
76 76  (1) NOP instruction (null instruction)
77 77  
... ... @@ -95,9 +95,9 @@
95 95  
96 96  (11) CPAVL instruction(communication BD configuration)
97 97  
98 -== **3.5 Unsupported special register function (M8000, D8000)** ==
98 +== **Unsupported special register function (M8000, D8000)** ==
99 99  
100 -=== **3.5.1 Clock related** ===
100 +=== **Clock related** ===
101 101  
102 102  Clock function not supported by LX5V
103 103  
... ... @@ -108,12 +108,12 @@
108 108  |=M8018|install and examine
109 109  |=M8019|Real-time clock (RTC) error
110 110  
111 -=== **3.5.2 High-speed counter ring counting function** ===
111 +=== **High-speed counter ring counting function** ===
112 112  
113 113  |=M8099|High-speed ring counter count start
114 114  |=M8099|Ring count configuration
115 115  
116 -=== **3.5.3 X0~~X5 pulse capture function** ===
116 +=== **X0~~X5 pulse capture function** ===
117 117  
118 118  |=M8170|X000 pulse capture
119 119  |=M8171|X001 pulse capture
... ... @@ -128,10 +128,13 @@
128 128  
129 129  Interpolation instructions (G90G01, G90G02, G90G03, G91G01, G91G02, G91G03)
130 130  
131 -= **5. 3V and 5V incompatible functions (These can be automatically converted in the future)** =
131 += **5 3V and 5V incompatible functions** =
132 132  
133 -== **5.1 General register** ==
133 +(% class="wikigeneratedid" %)
134 +**(These can be automatically converted in the future)**
134 134  
136 +== **General register** ==
137 +
135 135  (% class="table-bordered" %)
136 136  |=(% scope="row" %)**register**|=**LX3V**|=**LX5V**|=**Remarks**
137 137  |=Input|X0~~X377|X0~~X1777|
... ... @@ -160,10 +160,13 @@
160 160  
161 161  5. Pointer I is cancelled in LX5V, please check the programming mode for details.
162 162  
163 -== **5.2 Programming method** ==
166 +== **Programming method** ==
164 164  
165 -=== **5.2.1 Subroutine (For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)** ===
168 +=== **Subroutine** ===
166 166  
170 +(% class="wikigeneratedid" %)
171 +**(For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)**
172 +
167 167  **Use of LX3V subroutines**
168 168  [[image:1652684087594-147.png]]
169 169  
... ... @@ -177,8 +177,11 @@
177 177  
178 178  [[image:1652684829740-769.png]]
179 179  
180 -=== **5.2.2 Interrupt (For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)** ===
186 +=== **Interrupt** ===
181 181  
188 +(% class="wikigeneratedid" %)
189 +**(For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)**
190 +
182 182  **LX3V interrupt**
183 183  
184 184  The interrupt program is under FEND and returns with IRET. The meaning of the specific interrupt is distinguished by the pointer I number.(Refer to EI/DI instruction in 3V)
... ... @@ -197,9 +197,9 @@
197 197  
198 198  [[image:1652685809566-630.png]]
199 199  
200 -=== **5.2.3 Instructions** ===
209 +=== **Instructions** ===
201 201  
202 -**OUT command**
211 +**OUT instruction**
203 203  
204 204  Double word counter[[image:file:///C:\Users\ANNAXU~~1\AppData\Local\Temp\ksohtml14432\wps28.png]]
205 205  
... ... @@ -265,9 +265,9 @@
265 265  
266 266  [[image:1652689626279-240.png]]
267 267  
268 -= **6High-speed input function** =
277 += **6 High-speed input function** =
269 269  
270 -== **6.1 Use on LX3V** ==
279 +== **Use on LX3V** ==
271 271  
272 272  Find the high-speed input counter you need to use according to the following table:
273 273  
... ... @@ -279,7 +279,7 @@
279 279  
280 280  [[image:1652690126303-800.png]]
281 281  
282 -== **6.2 Use on LX5V** ==
291 +== **Use on LX5V** ==
283 283  
284 284  According to channel, select the HSC register to use:
285 285  
... ... @@ -293,11 +293,10 @@
293 293  
294 294  [[image:1652692388207-617.png]]
295 295  
296 -== **6.3 Difference between high-speed counters on LX5V and LX3V** ==
305 +== **Difference between high-speed counters on LX5V and LX3V** ==
297 297  
298 298  LX3V updates the count value when the OUT instruction is executed, which is affected by the scan cycle.
299 299  
300 -
301 301  LX5V is updated in the 100us interrupt, not affected by the scan cycle, and provides the REF instruction to refresh the current high-speed counter value immediately.
302 302  
303 303  LX5V single-phase high-speed counter supports filtering function, configurable 0~~17us.
... ... @@ -304,7 +304,7 @@
304 304  
305 305  LX5V high-speed input counter will update the input frequency in the special soft element (SD) every 100us.
306 306  
307 -= **7. High-speed output function** =
315 += **7 High-speed output function** =
308 308  
309 309  **High-speed pulse commands are the same in the use of commands.**
310 310  
... ... @@ -451,7 +451,7 @@
451 451  
452 452  ⑨Support direction reversal (can set the forward direction to low level)
453 453  
454 -= **8. Communication function** =
462 += **8 Communication function** =
455 455  
456 456  **~1. Communication parameter configuration**
457 457  
... ... @@ -527,6 +527,3 @@
527 527  **5. LX5V added functions**
528 528  
529 529  Modify serial communication parameters during RUN. For example, use PROTOCOL instruction to modify the protocol during run. The corresponding instruction description can also find the method of setting without instruction. For details, please refer to the relevant instructions of the instruction. Commands are PROTOCOL (set serial port protocol), PROTPARA (set serial port parameters), STATION (set station number)
530 -
531 -
532 -