Title
... ... @@ -1,1 +1,1 @@
1 -03 Difference between 3V, 5V and 5S
1 +17 LX3V/5V/5S comparsion
Parent
... ... @@ -1,1 +1,1 @@
1 -PLC Editor2.1 User manual.WebHome
1 +PLC Editor2.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.admin
1 +XWiki.Jim
Content
... ... @@ -1,4 +1,4 @@
1 -= **1 Basic difference between 3V, 5V and 5S** =
1 += **1 Basic differences** =
2 2  
3 3  |=(% scope="row" %)Functions|=5V|=5S|=3V
4 4  |=Running Mode|(% colspan="3" %)Cyclic scan /Interrupt
... ... @@ -8,7 +8,6 @@
8 8  1616;2416;2424;3624;|0806;1208;1212;1412;
9 9  1616;2416;2424;3624;
10 10  |=Programming|(% colspan="3" %)Ladder
11 -|=Type of instruction| | |
12 12  |=Execute Time|Basic 0.01-0.03μs|Basic 0.03-0.08μs|Basic 0.06μs/Applied instruction:1-10us
13 13  |=Program Capacity|(% colspan="2" %)512KB|16k
14 14  |=High Speed Pulse Output|≤1412MT and smaller: 4*200KHz;
... ... @@ -19,10 +19,22 @@
19 19  |=X Interrupt|X0-X7 Rising & Falling|X0-X5 Rising & Falling|X0-X5 Rising & Falling
20 20  |=**High speed counter Single Phase**|**≤1412 and smaller: 4*150KHz
21 21  ≥1616 and bigger: 8*150KHz**|**≤1412 and smaller: 2*150KHz;4*10KHz
22 -≥1616 and bigger: 6*150KHz**|**2*200KHz; 4*10KHz**
21 +≥1616 and bigger: 6*150KHz**|(((
22 +**Hardware counter for the first two channels:2*200KHz;**
23 +
24 +**Software counter for the first two channels:2*100KHz;**
25 +
26 +**Software counter for back four channels:4*10KHz**
27 +)))
23 23  |=**High speed counter AB phase**|**≤1412 and smaller: 4*100KHz
24 24  ≥1616 and bigger: 8*100KHz**|**≤1412 and smaller: 1*100KHz+2*10KHz
25 -≥1616 and bigger: 3*100KHz**|**2*100KHz**
30 +≥1616 and bigger: 3*100KHz**|(((
31 +**Hardware counter for the first two channels:2*100KHz;**
32 +
33 +**Software counter for the first two channels:2*50KHz;**
34 +
35 +**Software counter for back four channels:4*5KHz**
36 +)))
26 26  |=Storage Type|(% colspan="3" %)FLASH
27 27  |=Serial Communication|(((
28 28  COM1: RS422、RS485;COM2: RS485
... ... @@ -30,18 +30,18 @@
30 30  1212 and bigger: COM1: RS422、RS485;COM2:RS485|1208 and smaller: COM1: RS422;COM2: RS485;
31 31  1212 and bigger: COM1: RS422、RS485;COM2: RS485
32 32  |=BD board support|yes|yes|yes
33 -|=Communication BD board|(% colspan="2" %)inbuilt ethernet port series, RS485 BD board in developing |RS485 BD support, 3vp supports ethernet bd board
44 +|=Communication BD board|(% colspan="2" %)support LX5V-2RS485-BD and LX5V-ETH-BD|RS485 BD support, 3vp supports ethernet bd board
34 34  |=Expansion Module|(% colspan="2" %)yes √ (1212 and bigger can support)|yes √ (1212 and bigger can support)
35 35  |=Electronic CAM|√(2 sheets for switch)|√(2 sheets for switch)|N/A
36 36  |=S-type CAM|√|√|N/A
37 -|=N:N Comm|√|√|N/A
48 +|=PLClink|√|√|N/A
38 38  |=Linear Interpolation|√|√|N/A
39 39  |=Circular Interpolation|√|√|N/A
40 40  |=sub-rotine|√|√|N/A
41 41  
42 -= **2 Software interface difference between 5S and 5V** =
53 += **2 Software difference between 5S vs 5V** =
43 43  
44 -== **2.1 High speed counter configuration** ==
55 +== **High speed counter configuration** ==
45 45  
46 46  **5V as below**
47 47  
... ... @@ -49,29 +49,29 @@
49 49  
50 50  **5S is as below**
51 51  
52 -[[image:image-20220614151015-2.png]]
63 +[[image:企业微信截图_16762524911554.png]]
53 53  
54 54  **More detail information,please check the product catalog**
55 55  
56 56  = **3** **Functions that 3V has but 5V does not** =
57 57  
58 -== **3.1 BD board** ==
69 +== **BD board** ==
59 59  
60 -LX5V does not support RS485 BD
71 +LX5V does not support LX3V-2RS485-BD
61 61  
62 -LX5V does not support Ethernet BD
73 +LX5V does not support LX3V-ETH-BD
63 63  
64 -LX5V does not support CAN BD
75 +== **Analog BD board expansion address** ==
65 65  
66 -== **3.2 Analog BD board expansion address** ==
77 +Provides the function of analog board BD to modify parameters such as filtering. For specific functions, please refer to the below link:
78 +~1. LX3 series: [[5-9 System-special address - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor/05%20Registers/5-9%20system-special%20address/#HCOM1communicationsettings26BDmoduleconfiguration]]
79 +2. LX5 series: [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule]] [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule-1]]
67 67  
68 -Provides the function of analog board BD to modify parameters such as filtering. For specific functions, please refer to the BD board manual.
81 +== **PLDID** ==
69 69  
70 -== **3.3 PLDID** ==
71 -
72 72  Program label function, when the label of the program corresponds to the label of the PLC, the ladder diagram can be uploaded and downloaded. Clearing the memory does not clear this tag either. It is mainly to limit the ladder diagram used by PLC.
73 73  
74 -== **3.4 Instructions** ==
85 +== **Instructions** ==
75 75  
76 76  (1) NOP instruction (null instruction)
77 77  
... ... @@ -95,9 +95,9 @@
95 95  
96 96  (11) CPAVL instruction(communication BD configuration)
97 97  
98 -== **3.5 Unsupported special register function (M8000, D8000)** ==
109 +== **Unsupported special register function (M8000, D8000)** ==
99 99  
100 -=== **3.5.1 Clock related** ===
111 +=== **Clock related** ===
101 101  
102 102  Clock function not supported by LX5V
103 103  
... ... @@ -108,12 +108,12 @@
108 108  |=M8018|install and examine
109 109  |=M8019|Real-time clock (RTC) error
110 110  
111 -=== **3.5.2 High-speed counter ring counting function** ===
122 +=== **High-speed counter ring counting function** ===
112 112  
113 113  |=M8099|High-speed ring counter count start
114 114  |=M8099|Ring count configuration
115 115  
116 -=== **3.5.3 X0~~X5 pulse capture function** ===
127 +=== **X0~~X5 pulse capture function** ===
117 117  
118 118  |=M8170|X000 pulse capture
119 119  |=M8171|X001 pulse capture
... ... @@ -122,16 +122,13 @@
122 122  |=M8174|X004 pulse capture
123 123  |=M8175|X005 pulse capture
124 124  
125 -= **4. 5V function under development** =
136 += **4 3V and 5V incompatible functions** =
126 126  
127 -N:N communication protocol
138 +(% class="wikigeneratedid" %)
139 +**(These can be automatically converted in the future)**
128 128  
129 -Interpolation instructions (G90G01, G90G02, G90G03, G91G01, G91G02, G91G03)
141 +== **General register** ==
130 130  
131 -= **5. 3V and 5V incompatible functions (These can be automatically converted in the future)** =
132 -
133 -== **5.1 General register** ==
134 -
135 135  (% class="table-bordered" %)
136 136  |=(% scope="row" %)**register**|=**LX3V**|=**LX5V**|=**Remarks**
137 137  |=Input|X0~~X377|X0~~X1777|
... ... @@ -160,10 +160,13 @@
160 160  
161 161  5. Pointer I is cancelled in LX5V, please check the programming mode for details.
162 162  
163 -== **5.2 Programming method** ==
171 +== **Programming method** ==
164 164  
165 -=== **5.2.1 Subroutine (For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)** ===
173 +=== **Subroutine** ===
166 166  
175 +(% class="wikigeneratedid" %)
176 +**(For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)**
177 +
167 167  **Use of LX3V subroutines**
168 168  [[image:1652684087594-147.png]]
169 169  
... ... @@ -177,8 +177,11 @@
177 177  
178 178  [[image:1652684829740-769.png]]
179 179  
180 -=== **5.2.2 Interrupt (For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)** ===
191 +=== **Interrupt** ===
181 181  
193 +(% class="wikigeneratedid" %)
194 +**(For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)**
195 +
182 182  **LX3V interrupt**
183 183  
184 184  The interrupt program is under FEND and returns with IRET. The meaning of the specific interrupt is distinguished by the pointer I number.(Refer to EI/DI instruction in 3V)
... ... @@ -197,9 +197,9 @@
197 197  
198 198  [[image:1652685809566-630.png]]
199 199  
200 -=== **5.2.3 Instructions** ===
214 +=== **Instructions** ===
201 201  
202 -**OUT command**
216 +**OUT instruction**
203 203  
204 204  Double word counter[[image:file:///C:\Users\ANNAXU~~1\AppData\Local\Temp\ksohtml14432\wps28.png]]
205 205  
... ... @@ -265,9 +265,9 @@
265 265  
266 266  [[image:1652689626279-240.png]]
267 267  
268 -= **6. High-speed input function** =
282 += **5 High-speed input function** =
269 269  
270 -== **6.1 Use on LX3V** ==
284 +== **Use on LX3V** ==
271 271  
272 272  Find the high-speed input counter you need to use according to the following table:
273 273  
... ... @@ -279,7 +279,7 @@
279 279  
280 280  [[image:1652690126303-800.png]]
281 281  
282 -== **6.2 Use on LX5V** ==
296 +== **Use on LX5V** ==
283 283  
284 284  According to channel, select the HSC register to use:
285 285  
... ... @@ -293,11 +293,10 @@
293 293  
294 294  [[image:1652692388207-617.png]]
295 295  
296 -== **6.3 Difference between high-speed counters on LX5V and LX3V** ==
310 +== **Difference between high-speed counters on LX5V and LX3V** ==
297 297  
298 298  LX3V updates the count value when the OUT instruction is executed, which is affected by the scan cycle.
299 299  
300 -
301 301  LX5V is updated in the 100us interrupt, not affected by the scan cycle, and provides the REF instruction to refresh the current high-speed counter value immediately.
302 302  
303 303  LX5V single-phase high-speed counter supports filtering function, configurable 0~~17us.
... ... @@ -304,7 +304,7 @@
304 304  
305 305  LX5V high-speed input counter will update the input frequency in the special soft element (SD) every 100us.
306 306  
307 -= **7. High-speed output function** =
320 += **6 High-speed output function** =
308 308  
309 309  **High-speed pulse commands are the same in the use of commands.**
310 310  
... ... @@ -451,7 +451,7 @@
451 451  
452 452  ⑨Support direction reversal (can set the forward direction to low level)
453 453  
454 -= **8. Communication function** =
467 += **7 Communication function** =
455 455  
456 456  **~1. Communication parameter configuration**
457 457  
... ... @@ -527,6 +527,3 @@
527 527  **5. LX5V added functions**
528 528  
529 529  Modify serial communication parameters during RUN. For example, use PROTOCOL instruction to modify the protocol during run. The corresponding instruction description can also find the method of setting without instruction. For details, please refer to the relevant instructions of the instruction. Commands are PROTOCOL (set serial port protocol), PROTPARA (set serial port parameters), STATION (set station number)
530 -
531 -
532 -
企业微信截图_16762524911554.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Jim
Size
... ... @@ -1,0 +1,1 @@
1 +20.4 KB