Changes for page 17 LX3V/5V/5S comparsion
Last modified by Jim on 2025/02/11 11:34
From version 14.1
edited by Leo Wei
on 2022/06/14 15:36
on 2022/06/14 15:36
Change comment:
There is no comment for this version
To version 33.1
edited by Devin Chen
on 2023/10/31 10:26
on 2023/10/31 10:26
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - 03Difference between3V,5V and 5S1 +17 LX3V/5V/5S comparsion - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PLC Editor2. 1 User manual.WebHome1 +PLC Editor2.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. admin1 +XWiki.DevinChen - Content
-
... ... @@ -1,4 +1,4 @@ 1 -= **1 Basic difference between 3V, 5V and 5S** =1 += **1 Basic differences** = 2 2 3 3 |=(% scope="row" %)Functions|=5V|=5S|=3V 4 4 |=Running Mode|(% colspan="3" %)Cyclic scan /Interrupt ... ... @@ -8,7 +8,6 @@ 8 8 1616;2416;2424;3624;|0806;1208;1212;1412; 9 9 1616;2416;2424;3624; 10 10 |=Programming|(% colspan="3" %)Ladder 11 -|=Type of instruction| | | 12 12 |=Execute Time|Basic 0.01-0.03μs|Basic 0.03-0.08μs|Basic 0.06μs/Applied instruction:1-10us 13 13 |=Program Capacity|(% colspan="2" %)512KB|16k 14 14 |=High Speed Pulse Output|≤1412MT and smaller: 4*200KHz; ... ... @@ -19,10 +19,22 @@ 19 19 |=X Interrupt|X0-X7 Rising & Falling|X0-X5 Rising & Falling|X0-X5 Rising & Falling 20 20 |=**High speed counter Single Phase**|**≤1412 and smaller: 4*150KHz 21 21 ≥1616 and bigger: 8*150KHz**|**≤1412 and smaller: 2*150KHz;4*10KHz 22 -≥1616 and bigger: 6*150KHz**|**2*200KHz; 4*10KHz** 21 +≥1616 and bigger: 6*150KHz**|((( 22 +**Hardware counter for the first two channels:2*200KHz;** 23 + 24 +**Software counter for the first two channels:2*100KHz;** 25 + 26 +**Software counter for back four channels:4*10KHz** 27 +))) 23 23 |=**High speed counter AB phase**|**≤1412 and smaller: 4*100KHz 24 24 ≥1616 and bigger: 8*100KHz**|**≤1412 and smaller: 1*100KHz+2*10KHz 25 -≥1616 and bigger: 3*100KHz**|**2*100KHz** 30 +≥1616 and bigger: 3*100KHz**|((( 31 +**Hardware counter for the first two channels:2*100KHz;** 32 + 33 +**Software counter for the first two channels:2*50KHz;** 34 + 35 +**Software counter for back four channels:4*5KHz** 36 +))) 26 26 |=Storage Type|(% colspan="3" %)FLASH 27 27 |=Serial Communication|((( 28 28 COM1: RS422、RS485;COM2: RS485 ... ... @@ -30,18 +30,18 @@ 30 30 1212 and bigger: COM1: RS422、RS485;COM2:RS485|1208 and smaller: COM1: RS422;COM2: RS485; 31 31 1212 and bigger: COM1: RS422、RS485;COM2: RS485 32 32 |=BD board support|yes|yes|yes 33 -|=Communication BD board|(% colspan="2" %) inbuilt ethernetportseries,RS485board ineveloping|RS485 BD support, 3vp supports ethernet bd board44 +|=Communication BD board|(% colspan="2" %)support LX5V-2RS485-BD and LX5V-ETH-BD|RS485 BD support, 3vp supports ethernet bd board 34 34 |=Expansion Module|(% colspan="2" %)yes √ (1212 and bigger can support)|yes √ (1212 and bigger can support) 35 35 |=Electronic CAM|√(2 sheets for switch)|√(2 sheets for switch)|N/A 36 36 |=S-type CAM|√|√|N/A 37 -|= N:NComm|√|√|N/A48 +|=PLClink|√|√|N/A 38 38 |=Linear Interpolation|√|√|N/A 39 39 |=Circular Interpolation|√|√|N/A 40 -|=sub-rotine|√|√|N/A 51 +|=sub-routine|√|√|N/A 41 41 42 -= **2 Software interfacedifference between 5Sand5V** =53 += **2 Software difference between 5S vs 5V** = 43 43 44 -== ** 2.1High speed counter configuration** ==55 +== **High speed counter configuration** == 45 45 46 46 **5V as below** 47 47 ... ... @@ -49,29 +49,29 @@ 49 49 50 50 **5S is as below** 51 51 52 -[[image: image-20220614151015-2.png]]63 +[[image:企业微信截图_16762524911554.png]] 53 53 54 54 **More detail information,please check the product catalog** 55 55 56 56 = **3** **Functions that 3V has but 5V does not** = 57 57 58 -== ** 3.1BDboard** ==69 +== **BD module** == 59 59 60 -LX5V does not support RS485 71 +LX5V does not support LX3V-2RS485-BD 61 61 62 -LX5V does not support E thernetBD73 +LX5V does not support LX3V-ETH-BD 63 63 64 - LX5VdoesnotsupportCAN BD75 +== **Analog BD module expansion address** == 65 65 66 -== **3.2 Analog BD board expansion address** == 77 +Provides the function of analog module BD to modify parameters such as filtering. For specific functions, please refer to the below link: 78 +~1. LX3 series: [[5-9 System-special address - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor/05%20Registers/5-9%20system-special%20address/#HCOM1communicationsettings26BDmoduleconfiguration]] 79 +2. LX5 series: [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule]] [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule-1]] 67 67 68 - Providesthe function of analog board BDto modify parameters such as filtering. For specific functions, please refer to the BDboard manual.81 +== **PLDID** == 69 69 70 -== **3.3 PLDID** == 71 - 72 72 Program label function, when the label of the program corresponds to the label of the PLC, the ladder diagram can be uploaded and downloaded. Clearing the memory does not clear this tag either. It is mainly to limit the ladder diagram used by PLC. 73 73 74 -== ** 3.4Instructions** ==85 +== **Instructions** == 75 75 76 76 (1) NOP instruction (null instruction) 77 77 ... ... @@ -95,9 +95,9 @@ 95 95 96 96 (11) CPAVL instruction(communication BD configuration) 97 97 98 -== ** 3.5Unsupported special register function (M8000, D8000)** ==109 +== **Unsupported special register function (M8000, D8000)** == 99 99 100 -=== ** 3.5.1Clock related** ===111 +=== **Clock related** === 101 101 102 102 Clock function not supported by LX5V 103 103 ... ... @@ -108,12 +108,12 @@ 108 108 |=M8018|install and examine 109 109 |=M8019|Real-time clock (RTC) error 110 110 111 -=== ** 3.5.2High-speed counter ring counting function** ===122 +=== **High-speed counter ring counting function** === 112 112 113 113 |=M8099|High-speed ring counter count start 114 114 |=M8099|Ring count configuration 115 115 116 -=== ** 3.5.3X0~~X5 pulse capture function** ===127 +=== **X0~~X5 pulse capture function** === 117 117 118 118 |=M8170|X000 pulse capture 119 119 |=M8171|X001 pulse capture ... ... @@ -122,16 +122,13 @@ 122 122 |=M8174|X004 pulse capture 123 123 |=M8175|X005 pulse capture 124 124 125 -= **4 .5Vfunctionunder development** =136 += **4 3V and 5V incompatible functions** = 126 126 127 -N:N communication protocol 138 +(% class="wikigeneratedid" %) 139 +**(These can be automatically converted in the future)** 128 128 129 - Interpolationinstructions(G90G01, G90G02, G90G03, G91G01, G91G02, G91G03)141 +== **General register** == 130 130 131 -= **5. 3V and 5V incompatible functions (These can be automatically converted in the future)** = 132 - 133 -== **5.1 General register** == 134 - 135 135 (% class="table-bordered" %) 136 136 |=(% scope="row" %)**register**|=**LX3V**|=**LX5V**|=**Remarks** 137 137 |=Input|X0~~X377|X0~~X1777| ... ... @@ -160,10 +160,13 @@ 160 160 161 161 5. Pointer I is cancelled in LX5V, please check the programming mode for details. 162 162 163 -== ** 5.2Programming method** ==171 +== **Programming method** == 164 164 165 -=== ** 5.2.1Subroutine(For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)** ===173 +=== **Subroutine** === 166 166 175 +(% class="wikigeneratedid" %) 176 +**(For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)** 177 + 167 167 **Use of LX3V subroutines** 168 168 [[image:1652684087594-147.png]] 169 169 ... ... @@ -177,8 +177,11 @@ 177 177 178 178 [[image:1652684829740-769.png]] 179 179 180 -=== ** 5.2.2Interrupt(For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)** ===191 +=== **Interrupt** === 181 181 193 +(% class="wikigeneratedid" %) 194 +**(For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)** 195 + 182 182 **LX3V interrupt** 183 183 184 184 The interrupt program is under FEND and returns with IRET. The meaning of the specific interrupt is distinguished by the pointer I number.(Refer to EI/DI instruction in 3V) ... ... @@ -197,9 +197,9 @@ 197 197 198 198 [[image:1652685809566-630.png]] 199 199 200 -=== ** 5.2.3Instructions** ===214 +=== **Instructions** === 201 201 202 -**OUT co mmand**216 +**OUT instruction** 203 203 204 204 Double word counter[[image:file:///C:\Users\ANNAXU~~1\AppData\Local\Temp\ksohtml14432\wps28.png]] 205 205 ... ... @@ -265,9 +265,9 @@ 265 265 266 266 [[image:1652689626279-240.png]] 267 267 268 -= ** 6.High-speed input function** =282 += **5 High-speed input function** = 269 269 270 -== ** 6.1Use on LX3V** ==284 +== **Use on LX3V** == 271 271 272 272 Find the high-speed input counter you need to use according to the following table: 273 273 ... ... @@ -279,7 +279,7 @@ 279 279 280 280 [[image:1652690126303-800.png]] 281 281 282 -== ** 6.2Use on LX5V** ==296 +== **Use on LX5V** == 283 283 284 284 According to channel, select the HSC register to use: 285 285 ... ... @@ -293,11 +293,10 @@ 293 293 294 294 [[image:1652692388207-617.png]] 295 295 296 -== ** 6.3Difference between high-speed counters on LX5V and LX3V** ==310 +== **Difference between high-speed counters on LX5V and LX3V** == 297 297 298 298 LX3V updates the count value when the OUT instruction is executed, which is affected by the scan cycle. 299 299 300 - 301 301 LX5V is updated in the 100us interrupt, not affected by the scan cycle, and provides the REF instruction to refresh the current high-speed counter value immediately. 302 302 303 303 LX5V single-phase high-speed counter supports filtering function, configurable 0~~17us. ... ... @@ -304,7 +304,7 @@ 304 304 305 305 LX5V high-speed input counter will update the input frequency in the special soft element (SD) every 100us. 306 306 307 -= ** 7.High-speed output function** =320 += **6 High-speed output function** = 308 308 309 309 **High-speed pulse commands are the same in the use of commands.** 310 310 ... ... @@ -332,13 +332,13 @@ 332 332 (% class="table-bordered" %) 333 333 |=(% scope="row" %)**3V**|=**Description**|=**5V**|=**Description** 334 334 |=M8145|Y000 pulse output stop|SM898|Y000 pulse output stop 335 -|=M8146|Y001 Pulse output stop|SM958|Y001 Pulse output stop348 +|=M8146|Y001 pulse output stop|SM958|Y001 Pulse output stop 336 336 |=M8152|Y002 pulse output stop|SM1018|Y002 pulse output stop 337 -|=M8153|Y003 Pulse output stop|SM1078|Y003 Pulse output stop350 +|=M8153|Y003 pulse output stop|SM1078|Y003 Pulse output stop 338 338 |=M8147|Y000 monitoring during pulse output|SM880|Y000 monitoring during pulse output 339 -|=M8148|Y001 Monitoring during pulse output|SM940|Y001 Monitoring during pulse output340 -|=M8149|Y002 Monitoring during pulse output|SM1000|Y002 Monitoring during pulse output341 -|=M8150|Y003 Monitoring during pulse output|SM1060|Y003 Monitoring during pulse output352 +|=M8148|Y001 monitoring during pulse output|SM940|Y001 Monitoring during pulse output 353 +|=M8149|Y002 monitoring during pulse output|SM1000|Y002 Monitoring during pulse output 354 +|=M8150|Y003 monitoring during pulse output|SM1060|Y003 Monitoring during pulse output 342 342 |=(% rowspan="4" %)((( 343 343 344 344 ... ... @@ -358,8 +358,8 @@ 358 358 )))|((( 359 359 SM957 360 360 )))|Y1 Perimeter control bit 361 -|=M8136|Y2 Perimeter control bit|SM1017|Y2 Perimeter control bit362 -|=M8137|Y3 Perimeter control bit|SM1077|Y3 Perimeter control bit374 +|=M8136|Y2 perimeter control bit|SM1017|Y2 Perimeter control bit 375 +|=M8137|Y3 perimeter control bit|SM1077|Y3 Perimeter control bit 363 363 364 364 3. Comparison of word devices 365 365 ... ... @@ -369,14 +369,14 @@ 369 369 |=D8105|Y1 acceleration and deceleration time (open M8135)|SD1022/SD1082|Y1 acceleration/deceleration time 370 370 |=D8106|Y2 acceleration and deceleration time (open M8135)|SD1142/SD1202|Y2 acceleration/deceleration time 371 371 |=D8107|Y3 acceleration and deceleration time (open M8135)|SD1262/SD1322|Y3 acceleration/deceleration time 372 -|=D8140|Y000 Current position low|SD880|Y000 Current position low385 +|=D8140|Y000 current position low|SD880|Y000 Current position low 373 373 |=D8141|Y000 current position high|SD881|Y000 current position high 374 -|=D8142|Y001 Current position low|SD940|Y001 Current position low375 -|=D8143|Y001 Current position high|SD941|Y001 Current position high387 +|=D8142|Y001 current position low|SD940|Y001 Current position low 388 +|=D8143|Y001 current position high|SD941|Y001 Current position high 376 376 |=D8150|Y002 current position low|SD1000|Y002 current position low 377 377 |=D8151|Y002 current position high|SD1001|Y002 current position high 378 -|=D8152|Y003 Current position low|SD1060|Y003 Current position low379 -|=D8153|Y003 Current position high|SD1061|Y003 Current position high391 +|=D8152|Y003 current position low|SD1060|Y003 Current position low 392 +|=D8153|Y003 current position high|SD1061|Y003 Current position high 380 380 |=(% rowspan="4" %)((( 381 381 382 382 ... ... @@ -386,7 +386,7 @@ 386 386 387 387 388 388 389 -Y0-Y3 Paranoid speed (single word)402 +Y0-Y3 paranoid speed (single word) 390 390 )))|SD900, SD901|Y0 Paranoid speed (double word) 391 391 |=SD960, SD961|Y1 Paranoid speed (double word) 392 392 |=SD1020, SD1021|Y2 Paranoid speed (double word) ... ... @@ -451,7 +451,7 @@ 451 451 452 452 ⑨Support direction reversal (can set the forward direction to low level) 453 453 454 -= ** 8.Communication function** =467 += **7 Communication function** = 455 455 456 456 **~1. Communication parameter configuration** 457 457 ... ... @@ -527,6 +527,3 @@ 527 527 **5. LX5V added functions** 528 528 529 529 Modify serial communication parameters during RUN. For example, use PROTOCOL instruction to modify the protocol during run. The corresponding instruction description can also find the method of setting without instruction. For details, please refer to the relevant instructions of the instruction. Commands are PROTOCOL (set serial port protocol), PROTPARA (set serial port parameters), STATION (set station number) 530 - 531 - 532 -
- 企业微信截图_16762524911554.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.4 KB - Content