Changes for page 17 LX3V/5V/5S comparsion

Last modified by Jim on 2025/02/11 11:34

From version 21.1
edited by Jim
on 2022/09/03 13:50
Change comment: There is no comment for this version
To version 31.1
edited by Karen
on 2023/05/30 11:47
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Jim
1 +XWiki.Karen
Content
... ... @@ -8,7 +8,6 @@
8 8  1616;2416;2424;3624;|0806;1208;1212;1412;
9 9  1616;2416;2424;3624;
10 10  |=Programming|(% colspan="3" %)Ladder
11 -|=Type of instruction| | |
12 12  |=Execute Time|Basic 0.01-0.03μs|Basic 0.03-0.08μs|Basic 0.06μs/Applied instruction:1-10us
13 13  |=Program Capacity|(% colspan="2" %)512KB|16k
14 14  |=High Speed Pulse Output|≤1412MT and smaller: 4*200KHz;
... ... @@ -19,10 +19,22 @@
19 19  |=X Interrupt|X0-X7 Rising & Falling|X0-X5 Rising & Falling|X0-X5 Rising & Falling
20 20  |=**High speed counter Single Phase**|**≤1412 and smaller: 4*150KHz
21 21  ≥1616 and bigger: 8*150KHz**|**≤1412 and smaller: 2*150KHz;4*10KHz
22 -≥1616 and bigger: 6*150KHz**|**2*200KHz; 4*10KHz**
21 +≥1616 and bigger: 6*150KHz**|(((
22 +**Hardware counter for the first two channels:2*200KHz;**
23 +
24 +**Software counter for the first two channels:2*100KHz;**
25 +
26 +**Software counter for back four channels:4*10KHz**
27 +)))
23 23  |=**High speed counter AB phase**|**≤1412 and smaller: 4*100KHz
24 24  ≥1616 and bigger: 8*100KHz**|**≤1412 and smaller: 1*100KHz+2*10KHz
25 -≥1616 and bigger: 3*100KHz**|**2*100KHz**
30 +≥1616 and bigger: 3*100KHz**|(((
31 +**Hardware counter for the first two channels:2*100KHz;**
32 +
33 +**Software counter for the first two channels:2*50KHz;**
34 +
35 +**Software counter for back four channels:4*5KHz**
36 +)))
26 26  |=Storage Type|(% colspan="3" %)FLASH
27 27  |=Serial Communication|(((
28 28  COM1: RS422、RS485;COM2: RS485
... ... @@ -30,11 +30,11 @@
30 30  1212 and bigger: COM1: RS422、RS485;COM2:RS485|1208 and smaller: COM1: RS422;COM2: RS485;
31 31  1212 and bigger: COM1: RS422、RS485;COM2: RS485
32 32  |=BD board support|yes|yes|yes
33 -|=Communication BD board|(% colspan="2" %)support LX5V-RS485 BD and LX5V-ETH-BD|RS485 BD support, 3vp supports ethernet bd board
44 +|=Communication BD board|(% colspan="2" %)support LX5V-2RS485-BD and LX5V-ETH-BD|RS485 BD support, 3vp supports ethernet bd board
34 34  |=Expansion Module|(% colspan="2" %)yes √ (1212 and bigger can support)|yes √ (1212 and bigger can support)
35 35  |=Electronic CAM|√(2 sheets for switch)|√(2 sheets for switch)|N/A
36 36  |=S-type CAM|√|√|N/A
37 -|=N:N Comm|√|√|N/A
48 +|=PLClink|√|√|N/A
38 38  |=Linear Interpolation|√|√|N/A
39 39  |=Circular Interpolation|√|√|N/A
40 40  |=sub-rotine|√|√|N/A
... ... @@ -49,24 +49,24 @@
49 49  
50 50  **5S is as below**
51 51  
52 -[[image:image-20220614151015-2.png]]
63 +[[image:企业微信截图_16762524911554.png]]
53 53  
54 54  **More detail information,please check the product catalog**
55 55  
56 56  = **3** **Functions that 3V has but 5V does not** =
57 57  
58 -== **BD board** ==
69 +== **BD module** ==
59 59  
60 -LX5V does not support RS485 BD
71 +LX5V does not support LX3V-2RS485-BD
61 61  
62 -LX5V does not support Ethernet BD
73 +LX5V does not support LX3V-ETH-BD
63 63  
64 -LX5V does not support CAN BD
75 +== **Analog BD module expansion address** ==
65 65  
66 -== **Analog BD board expansion address** ==
77 +Provides the function of analog module BD to modify parameters such as filtering. For specific functions, please refer to the below link:
78 +~1. LX3 series: [[5-9 System-special address - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor/05%20Registers/5-9%20system-special%20address/#HCOM1communicationsettings26BDmoduleconfiguration]]
79 +2. LX5 series: [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule]] [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule-1]]
67 67  
68 -Provides the function of analog board BD to modify parameters such as filtering. For specific functions, please refer to the BD board manual.
69 -
70 70  == **PLDID** ==
71 71  
72 72  Program label function, when the label of the program corresponds to the label of the PLC, the ladder diagram can be uploaded and downloaded. Clearing the memory does not clear this tag either. It is mainly to limit the ladder diagram used by PLC.
... ... @@ -122,14 +122,8 @@
122 122  |=M8174|X004 pulse capture
123 123  |=M8175|X005 pulse capture
124 124  
125 -= **4 5V function under development** =
136 += **4 3V and 5V incompatible functions** =
126 126  
127 -N:N communication protocol
128 -
129 -Interpolation instructions (G90G01, G90G02, G90G03, G91G01, G91G02, G91G03)
130 -
131 -= **5 3V and 5V incompatible functions** =
132 -
133 133  (% class="wikigeneratedid" %)
134 134  **(These can be automatically converted in the future)**
135 135  
... ... @@ -274,7 +274,7 @@
274 274  
275 275  [[image:1652689626279-240.png]]
276 276  
277 -= **6 High-speed input function** =
282 += **5 High-speed input function** =
278 278  
279 279  == **Use on LX3V** ==
280 280  
... ... @@ -312,7 +312,7 @@
312 312  
313 313  LX5V high-speed input counter will update the input frequency in the special soft element (SD) every 100us.
314 314  
315 -= **7 High-speed output function** =
320 += **6 High-speed output function** =
316 316  
317 317  **High-speed pulse commands are the same in the use of commands.**
318 318  
... ... @@ -459,7 +459,7 @@
459 459  
460 460  ⑨Support direction reversal (can set the forward direction to low level)
461 461  
462 -= **8 Communication function** =
467 += **7 Communication function** =
463 463  
464 464  **~1. Communication parameter configuration**
465 465  
企业微信截图_16762524911554.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Jim
Size
... ... @@ -1,0 +1,1 @@
1 +20.4 KB
Content