Changes for page 17 LX3V/5V/5S comparsion

Last modified by Jim on 2025/02/11 11:34

From version 24.1
edited by Jim
on 2022/09/06 11:25
Change comment: There is no comment for this version
To version 6.1
edited by Jim
on 2022/06/14 15:07
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -17 LX3V/5V/5S comparsion
1 +03 Difference between 3V, 5V and 5S
Parent
... ... @@ -1,1 +1,1 @@
1 -PLC Editor2.WebHome
1 +PLC Editor2.1 User manual.WebHome
Content
... ... @@ -1,75 +1,80 @@
1 -= **1 Basic differences** =
1 += **3.1 Basic difference between 5S and 5V** =
2 2  
3 -|=(% scope="row" %)Functions|=5V|=5S|=3V
4 -|=Running Mode|(% colspan="3" %)Cyclic scan /Interrupt
5 -|=Power supply|(% colspan="3" %)A:AC 220V;D:DC 24V
6 -|=Output type|MT:Transistor|MT:Transistor;MR:Relay|MT:Transistor;MR:Relay
7 -|=I/O|1212;1412;1616;2416;2424;3624;|0806;1208;1212;1412;
3 +|Functions|5V|5S|3V
4 +|Running Mode|(% colspan="3" %)Cyclic scan /Interrupt
5 +|Power supply|(% colspan="3" %)A:AC 220V;D:DC 24V
6 +|Output type|MT:Transistor|MT:Transistor;MR:Relay|MT:Transistor;MR:Relay
7 +|I/O|1212;1412;1616;2416;2424;3624;|0806;1208;1212;1412;
8 8  1616;2416;2424;3624;|0806;1208;1212;1412;
9 9  1616;2416;2424;3624;
10 -|=Programming|(% colspan="3" %)Ladder
11 -|=Type of instruction| | |
12 -|=Execute Time|Basic 0.01-0.03μs|Basic 0.03-0.08μs|Basic 0.06μs/Applied instruction:1-10us
13 -|=Program Capacity|(% colspan="2" %)512KB|16k
14 -|=High Speed Pulse Output|≤1412MT and smaller: 4*200KHz;
10 +|Programming|(% colspan="3" %)Ladder
11 +|Type of instruction| | |
12 +|Execute Time|Basic 0.01-0.03μs|Basic 0.03-0.08μs|Basic 0.06μs/Applied instruction:1-10us
13 +|Program Capacity|(% colspan="2" %)512KB|16k
14 +|High Speed Pulse Output|≤1412MT and smaller: 4*200KHz;
15 15  ≥1616MT and bigger:  8*200KHz。|MT/MR2H: 2* 200KHz;
16 16  MT4H: 4* 200KHz。|MT/2H: 2*100KHZ, or 4H: 4*100, single: 200kHZ
17 -|=High speed counter Interrupt|(% colspan="2" %)100 channels|21channels
18 -|=Timer Interrupt|(% colspan="2" %)100 channels,Support 0.1ms Interrupt|95 channels
19 -|=X Interrupt|X0-X7 Rising & Falling|X0-X5 Rising & Falling|X0-X5 Rising & Falling
20 -|=**High speed counter Single Phase**|**≤1412 and smaller: 4*150KHz
17 +|High speed counter Interrupt|(% colspan="2" %)100 channels|21channels
18 +|Timer Interrupt|(% colspan="2" %)100 channels,Support 0.1ms Interrupt|95 channels
19 +|X Interrupt|X0-X7 Rising & Falling|X0-X5 Rising & Falling|X0-X5 Rising & Falling
20 +|**High speed counter Single Phase**|**≤1412 and smaller: 4*150KHz
21 21  ≥1616 and bigger: 8*150KHz**|**≤1412 and smaller: 2*150KHz;4*10KHz
22 22  ≥1616 and bigger: 6*150KHz**|**2*200KHz; 4*10KHz**
23 -|=**High speed counter AB phase**|**≤1412 and smaller: 4*100KHz
23 +|**High speed counter AB phase**|**≤1412 and smaller: 4*100KHz
24 24  ≥1616 and bigger: 8*100KHz**|**≤1412 and smaller: 1*100KHz+2*10KHz
25 25  ≥1616 and bigger: 3*100KHz**|**2*100KHz**
26 -|=Storage Type|(% colspan="3" %)FLASH
27 -|=Serial Communication|(((
26 +|Storage Type|(% colspan="3" %)FLASH
27 +|Serial Communication|(((
28 28  COM1: RS422、RS485;COM2: RS485
29 29  )))|1208 and smaller: COM1: RS422;COM2: RS485;
30 30  1212 and bigger: COM1: RS422、RS485;COM2:RS485|1208 and smaller: COM1: RS422;COM2: RS485;
31 31  1212 and bigger: COM1: RS422、RS485;COM2: RS485
32 -|=BD board support|yes|yes|yes
33 -|=Communication BD board|(% colspan="2" %)support LX5V-2RS485-BD and LX5V-ETH-BD|RS485 BD support, 3vp supports ethernet bd board
34 -|=Expansion Module|(% colspan="2" %)yes √ (1212 and bigger can support)|yes √ (1212 and bigger can support)
35 -|=Electronic CAM|√(2 sheets for switch)|√(2 sheets for switch)|N/A
36 -|=S-type CAM|√|√|N/A
37 -|=N:N Comm|√|√|N/A
38 -|=Linear Interpolation|√|√|N/A
39 -|=Circular Interpolation|√|√|N/A
40 -|=sub-rotine|√|√|N/A
32 +|BD board support|yes|yes|yes
33 +|Communication BD board|(% colspan="2" %)inbuilt ethernet port series, RS485 BD board in developing |RS485 BD support, 3vp supports ethernet bd board
34 +|Expansion Module|(% colspan="2" %)yes √ (1212 and bigger can support)|yes √ (1212 and bigger can support)
35 +|Electronic CAM|√(2 sheets for switch)|√(2 sheets for switch)|N/A
36 +|S-type CAM|√|√|N/A
37 +|N:N Comm|√|√|N/A
38 +|Linear Interpolation|√|√|N/A
39 +|Circular Interpolation|√|√|N/A
40 +|sub-rotine|√|√|N/A
41 +| | | |
41 41  
42 -= **2 Software difference between 5S vs 5V** =
43 += **3.2 Software interface difference between 5S and 5V** =
43 43  
44 -== **High speed counter configuration** ==
45 +== **3.2.1 High speed counter configuration** ==
45 45  
46 46  **5V as below**
47 47  
48 -[[image:image-20220614151005-1.png]]
49 +(% style="text-align:center" %)
50 +[[image:1647833350904-233.png||height="377" width="900" class="img-thumbnail"]]
49 49  
50 50  **5S is as below**
51 51  
52 -[[image:image-20220614151015-2.png]]
54 +(% style="text-align:center" %)
55 +[[image:1647833437165-319.png||height="376" width="900" class="img-thumbnail"]]
53 53  
54 54  **More detail information,please check the product catalog**
55 55  
56 -= **3** **Functions that 3V has but 5V does not** =
59 += **1.** **Functions that 3V has but 5V does not** =
57 57  
58 -== **BD board** ==
61 +== **1.1 BD board** ==
59 59  
60 -LX5V does not support LX3V-2RS485-BD
63 +LX5V does not support RS485 BD
61 61  
62 -LX5V does not support LX3V-ETH-BD
65 +LX5V does not support Ethernet BD
63 63  
64 -== **Analog BD board expansion address** ==
67 +LX5V does not support CAN BD
65 65  
69 +== **1.2 Analog BD board expansion address** ==
70 +
66 66  Provides the function of analog board BD to modify parameters such as filtering. For specific functions, please refer to the BD board manual.
67 67  
68 -== **PLDID** ==
73 +== **1.3 PLDID** ==
69 69  
70 70  Program label function, when the label of the program corresponds to the label of the PLC, the ladder diagram can be uploaded and downloaded. Clearing the memory does not clear this tag either. It is mainly to limit the ladder diagram used by PLC.
71 71  
72 -== **Instructions** ==
77 +== **1.4 Instructions** ==
73 73  
74 74  (1) NOP instruction (null instruction)
75 75  
... ... @@ -93,55 +93,61 @@
93 93  
94 94  (11) CPAVL instruction(communication BD configuration)
95 95  
96 -== **Unsupported special register function (M8000, D8000)** ==
101 +== **1.5 Unsupported special register function (M8000, D8000)** ==
97 97  
98 -=== **Clock related** ===
103 +=== **1.5.1 Clock related** ===
99 99  
100 100  Clock function not supported by LX5V
101 101  
102 -|=M8014|Oscillation clock with 1 minute clock period
103 -|=M8015|Clock stop and preset
104 -|=M8016|Stop time to read the display
105 -|=M8017|±30 seconds correction
106 -|=M8018|install and examine
107 -|=M8019|Real-time clock (RTC) error
107 +(% class="table-bordered" %)
108 +|M8014|Oscillation clock with 1 minute clock period
109 +|M8015|Clock stop and preset
110 +|M8016|Stop time to read the display
111 +|M8017|±30 seconds correction
112 +|M8018|install and examine
113 +|M8019|Real-time clock (RTC) error
108 108  
109 -=== **High-speed counter ring counting function** ===
115 +=== **1.5.2 High-speed counter ring counting function** ===
110 110  
111 -|=M8099|High-speed ring counter count start
112 -|=M8099|Ring count configuration
117 +(% class="table-bordered" %)
118 +|M8099|High-speed ring counter count start
119 +|M8099|Ring count configuration
113 113  
114 -=== **X0~~X5 pulse capture function** ===
121 +=== **1.5.3 X0~~X5 pulse capture function** ===
115 115  
116 -|=M8170|X000 pulse capture
117 -|=M8171|X001 pulse capture
118 -|=M8172|X002 pulse capture
119 -|=M8173|X003 pulse capture
120 -|=M8174|X004 pulse capture
121 -|=M8175|X005 pulse capture
123 +(% class="table-bordered" %)
124 +|M8170|X000 pulse capture
125 +|M8171|X001 pulse capture
126 +|M8172|X002 pulse capture
127 +|M8173|X003 pulse capture
128 +|M8174|X004 pulse capture
129 +|M8175|X005 pulse capture
122 122  
123 -= **4 3V and 5V incompatible functions** =
131 += **2. 5V function under development** =
124 124  
125 -(% class="wikigeneratedid" %)
126 -**(These can be automatically converted in the future)**
133 +N:N communication protocol
127 127  
128 -== **General register** ==
135 +Interpolation instructions (G90G01, G90G02, G90G03, G91G01, G91G02, G91G03)
129 129  
137 += **3. 3V and 5V incompatible functions (These can be automatically converted in the future)** =
138 +
139 +== **3.1 General register** ==
140 +
130 130  (% class="table-bordered" %)
131 -|=(% scope="row" %)**register**|=**LX3V**|=**LX5V**|=**Remarks**
132 -|=Input|X0~~X377|X0~~X1777|
133 -|=Output|Y0~~Y377|Y0~~Y1777|
134 -|=Auxiliary|M0~~M3071|M0~~M7999|
135 -|=Status|S0~~S999|S0~~S4095|
136 -|=Timer|T0~~T255|T0~~T511|
137 -|=counter|C0~~C199|C0~~C255|
138 -|=Double word counter|C200~~C219|LC0~~LC99|Non-power-down save
139 -|=Double word counter|C220~~C234|LC100~~LC255|Power-down save
140 -|=High-speed counter|C235~~C255|HSC0~~HSC7|Check the high-speed input function
141 -|=Data Register|D0~~D7999|D0~~D7999 (R0~~R29999)|
142 -|=Pointer P|P0~~P127|P0~~P4095|
143 -|=Instruction I|I0~~I8xx|None|
144 -|=constant|K, H, E|K, H, E|
142 +|**register**|**LX3V**|**LX5V**|**Remarks**
143 +|Input|X0~~X377|X0~~X1777|
144 +|Output|Y0~~Y377|Y0~~Y1777|
145 +|Auxiliary|M0~~M3071|M0~~M7999|
146 +|Status|S0~~S999|S0~~S4095|
147 +|Timer|T0~~T255|T0~~T511|
148 +|counter|C0~~C199|C0~~C255|
149 +|Double word counter|C200~~C219|LC0~~LC99|Non-power-down save
150 +|Double word counter|C220~~C234|LC100~~LC255|Power-down save
151 +|High-speed counter|C235~~C255|HSC0~~HSC7|Check the high-speed input function
152 +|Data Register|D0~~D7999|D0~~D7999 (R0~~R29999)|
153 +|Pointer P|P0~~P127|P0~~P4095|
154 +|Instruction I|I0~~I8xx|None|
155 +|constant|K, H, E|K, H, E|
145 145  
146 146  **Incompatible part**
147 147  
... ... @@ -155,13 +155,10 @@
155 155  
156 156  5. Pointer I is cancelled in LX5V, please check the programming mode for details.
157 157  
158 -== **Programming method** ==
169 +== **3.2 Programming method** ==
159 159  
160 -=== **Subroutine** ===
171 +=== **3.2.1 Subroutine (For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)** ===
161 161  
162 -(% class="wikigeneratedid" %)
163 -**(For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)**
164 -
165 165  **Use of LX3V subroutines**
166 166  [[image:1652684087594-147.png]]
167 167  
... ... @@ -175,11 +175,8 @@
175 175  
176 176  [[image:1652684829740-769.png]]
177 177  
178 -=== **Interrupt** ===
186 +=== **3.2.2 Interrupt (For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)** ===
179 179  
180 -(% class="wikigeneratedid" %)
181 -**(For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)**
182 -
183 183  **LX3V interrupt**
184 184  
185 185  The interrupt program is under FEND and returns with IRET. The meaning of the specific interrupt is distinguished by the pointer I number.(Refer to EI/DI instruction in 3V)
... ... @@ -198,9 +198,9 @@
198 198  
199 199  [[image:1652685809566-630.png]]
200 200  
201 -=== **Instructions** ===
206 +=== **3.2.3 Instructions** ===
202 202  
203 -**OUT instruction**
208 +**OUT command**
204 204  
205 205  Double word counter[[image:file:///C:\Users\ANNAXU~~1\AppData\Local\Temp\ksohtml14432\wps28.png]]
206 206  
... ... @@ -266,9 +266,9 @@
266 266  
267 267  [[image:1652689626279-240.png]]
268 268  
269 -= **5 High-speed input function** =
274 += **4. High-speed input function** =
270 270  
271 -== **Use on LX3V** ==
276 +== **4.1 Use on LX3V** ==
272 272  
273 273  Find the high-speed input counter you need to use according to the following table:
274 274  
... ... @@ -280,7 +280,7 @@
280 280  
281 281  [[image:1652690126303-800.png]]
282 282  
283 -== **Use on LX5V** ==
288 +== **4.2 Use on LX5V** ==
284 284  
285 285  According to channel, select the HSC register to use:
286 286  
... ... @@ -294,10 +294,11 @@
294 294  
295 295  [[image:1652692388207-617.png]]
296 296  
297 -== **Difference between high-speed counters on LX5V and LX3V** ==
302 +== **4.3 Difference between high-speed counters on LX5V and LX3V** ==
298 298  
299 299  LX3V updates the count value when the OUT instruction is executed, which is affected by the scan cycle.
300 300  
306 +
301 301  LX5V is updated in the 100us interrupt, not affected by the scan cycle, and provides the REF instruction to refresh the current high-speed counter value immediately.
302 302  
303 303  LX5V single-phase high-speed counter supports filtering function, configurable 0~~17us.
... ... @@ -304,20 +304,20 @@
304 304  
305 305  LX5V high-speed input counter will update the input frequency in the special soft element (SD) every 100us.
306 306  
307 -= **6 High-speed output function** =
313 += **5. High-speed output function** =
308 308  
309 309  **High-speed pulse commands are the same in the use of commands.**
310 310  
311 311  (% class="table-bordered" %)
312 -|=(% scope="row" %) |=LX3V|=LX5V
313 -|=DRVI|√|√
314 -|=DRVA|√|√
315 -|=PLSR|√|√
316 -|=PLSV|√|√
317 -|=PLSY|√|√
318 -|=DVIT|√|√
319 -|=ZRN|√|√
320 -|=PLSR2|√|√
318 +| |LX3V|LX5V
319 +|DRVI|√|√
320 +|DRVA|√|√
321 +|PLSR|√|√
322 +|PLSV|√|√
323 +|PLSY|√|√
324 +|DVIT|√|√
325 +|ZRN|√|√
326 +|PLSR2|√|√
321 321  
322 322  **High-speed pulse command difference.**
323 323  
... ... @@ -330,16 +330,16 @@
330 330  2. Comparison of bit devices
331 331  
332 332  (% class="table-bordered" %)
333 -|=(% scope="row" %)**3V**|=**Description**|=**5V**|=**Description**
334 -|=M8145|Y000 pulse output stop|SM898|Y000 pulse output stop
335 -|=M8146|Y001 Pulse output stop|SM958|Y001 Pulse output stop
336 -|=M8152|Y002 pulse output stop|SM1018|Y002 pulse output stop
337 -|=M8153|Y003 Pulse output stop|SM1078|Y003 Pulse output stop
338 -|=M8147|Y000 monitoring during pulse output|SM880|Y000 monitoring during pulse output
339 -|=M8148|Y001 Monitoring during pulse output|SM940|Y001 Monitoring during pulse output
340 -|=M8149|Y002 Monitoring during pulse output|SM1000|Y002 Monitoring during pulse output
341 -|=M8150|Y003 Monitoring during pulse output|SM1060|Y003 Monitoring during pulse output
342 -|=(% rowspan="4" %)(((
339 +|**3V**|**Description**|**5V**|**Description**
340 +|M8145|Y000 pulse output stop|SM898|Y000 pulse output stop
341 +|M8146|Y001 Pulse output stop|SM958|Y001 Pulse output stop
342 +|M8152|Y002 pulse output stop|SM1018|Y002 pulse output stop
343 +|M8153|Y003 Pulse output stop|SM1078|Y003 Pulse output stop
344 +|M8147|Y000 monitoring during pulse output|SM880|Y000 monitoring during pulse output
345 +|M8148|Y001 Monitoring during pulse output|SM940|Y001 Monitoring during pulse output
346 +|M8149|Y002 Monitoring during pulse output|SM1000|Y002 Monitoring during pulse output
347 +|M8150|Y003 Monitoring during pulse output|SM1060|Y003 Monitoring during pulse output
348 +|(% rowspan="4" %)(((
343 343  
344 344  
345 345  
... ... @@ -349,35 +349,35 @@
349 349  
350 350  Some instructions (PLSR, etc.) instruction execution completed (Y0-Y3)
351 351  )))|SM882|Y0 pulse sending completed
352 -|=SM942|Y1 pulse sending completed
353 -|=SM1002|Y2 pulse transmission completed
354 -|=SM1062|Y3 pulse transmission completed
355 -|=M8134|Y0's thousandth control bit|SM897|Y0's thousandth control bit
356 -|=M8135|(((
358 +|SM942|Y1 pulse sending completed
359 +|SM1002|Y2 pulse transmission completed
360 +|SM1062|Y3 pulse transmission completed
361 +|M8134|Y0's thousandth control bit|SM897|Y0's thousandth control bit
362 +|M8135|(((
357 357  The acceleration and deceleration time between each axis of Y1's thousandth control position positioning command is separated
358 358  )))|(((
359 359  SM957
360 360  )))|Y1 Perimeter control bit
361 -|=M8136|Y2 Perimeter control bit|SM1017|Y2 Perimeter control bit
362 -|=M8137|Y3 Perimeter control bit|SM1077|Y3 Perimeter control bit
367 +|M8136|Y2 Perimeter control bit|SM1017|Y2 Perimeter control bit
368 +|M8137|Y3 Perimeter control bit|SM1077|Y3 Perimeter control bit
363 363  
364 364  3. Comparison of word devices
365 365  
366 366  (% class="table-bordered" %)
367 -|=(% scope="row" %)**3V**|=**Description**|=**5V**|=**Description**
368 -|=D8104|Y0 acceleration and deceleration time (open M8135)|SD902/SD962|Y0 acceleration/deceleration time
369 -|=D8105|Y1 acceleration and deceleration time (open M8135)|SD1022/SD1082|Y1 acceleration/deceleration time
370 -|=D8106|Y2 acceleration and deceleration time (open M8135)|SD1142/SD1202|Y2 acceleration/deceleration time
371 -|=D8107|Y3 acceleration and deceleration time (open M8135)|SD1262/SD1322|Y3 acceleration/deceleration time
372 -|=D8140|Y000 Current position low|SD880|Y000 Current position low
373 -|=D8141|Y000 current position high|SD881|Y000 current position high
374 -|=D8142|Y001 Current position low|SD940|Y001 Current position low
375 -|=D8143|Y001 Current position high|SD941|Y001 Current position high
376 -|=D8150|Y002 current position low|SD1000|Y002 current position low
377 -|=D8151|Y002 current position high|SD1001|Y002 current position high
378 -|=D8152|Y003 Current position low|SD1060|Y003 Current position low
379 -|=D8153|Y003 Current position high|SD1061|Y003 Current position high
380 -|=(% rowspan="4" %)(((
373 +|**3V**|**Description**|**5V**|**Description**
374 +|D8104|Y0 acceleration and deceleration time (open M8135)|SD902/SD962|Y0 acceleration/deceleration time
375 +|D8105|Y1 acceleration and deceleration time (open M8135)|SD1022/SD1082|Y1 acceleration/deceleration time
376 +|D8106|Y2 acceleration and deceleration time (open M8135)|SD1142/SD1202|Y2 acceleration/deceleration time
377 +|D8107|Y3 acceleration and deceleration time (open M8135)|SD1262/SD1322|Y3 acceleration/deceleration time
378 +|D8140|Y000 Current position low|SD880|Y000 Current position low
379 +|D8141|Y000 current position high|SD881|Y000 current position high
380 +|D8142|Y001 Current position low|SD940|Y001 Current position low
381 +|D8143|Y001 Current position high|SD941|Y001 Current position high
382 +|D8150|Y002 current position low|SD1000|Y002 current position low
383 +|D8151|Y002 current position high|SD1001|Y002 current position high
384 +|D8152|Y003 Current position low|SD1060|Y003 Current position low
385 +|D8153|Y003 Current position high|SD1061|Y003 Current position high
386 +|(% rowspan="4" %)(((
381 381  
382 382  
383 383  
... ... @@ -388,10 +388,10 @@
388 388  
389 389  Y0-Y3 Paranoid speed (single word)
390 390  )))|SD900, SD901|Y0 Paranoid speed (double word)
391 -|=SD960, SD961|Y1 Paranoid speed (double word)
392 -|=SD1020, SD1021|Y2 Paranoid speed (double word)
393 -|=SD1080, SD1081|Y3 Paranoid speed (double word)
394 -|=(% rowspan="8" %)(((
397 +|SD960, SD961|Y1 Paranoid speed (double word)
398 +|SD1020, SD1021|Y2 Paranoid speed (double word)
399 +|SD1080, SD1081|Y3 Paranoid speed (double word)
400 +|(% rowspan="8" %)(((
395 395  
396 396  
397 397  
... ... @@ -406,14 +406,14 @@
406 406  
407 407  Y0-Y3 maximum frequency (double word)
408 408  )))|SD898|Y0 Maximum speed low
409 -|=SD899|Y0 Highest speed
410 -|=SD958|Y1 Maximum speed low
411 -|=SD959|Y1 Highest speed
412 -|=SD1018|Y2 Maximum speed low
413 -|=SD1019|Y2 Highest speed
414 -|=SD1078|Y3 Maximum speed low
415 -|=SD1079|Y3 Highest speed
416 -|=(% rowspan="4" %)(((
415 +|SD899|Y0 Highest speed
416 +|SD958|Y1 Maximum speed low
417 +|SD959|Y1 Highest speed
418 +|SD1018|Y2 Maximum speed low
419 +|SD1019|Y2 Highest speed
420 +|SD1078|Y3 Maximum speed low
421 +|SD1079|Y3 Highest speed
422 +|(% rowspan="4" %)(((
417 417  
418 418  
419 419  
... ... @@ -423,9 +423,9 @@
423 423  
424 424  4-axis acceleration/deceleration time (when M8135 is not turned on)
425 425  )))|SD902/SD962|Y0 acceleration/deceleration time
426 -|=SD1022/SD1082|Y1 acceleration/deceleration time
427 -|=SD1142/SD1202|Y2 acceleration/deceleration time
428 -|=SD1262/SD1322|Y3 acceleration/deceleration time
432 +|SD1022/SD1082|Y1 acceleration/deceleration time
433 +|SD1142/SD1202|Y2 acceleration/deceleration time
434 +|SD1262/SD1322|Y3 acceleration/deceleration time
429 429  
430 430   4. New features of high-speed pulse instructions on LX5V
431 431  
... ... @@ -451,7 +451,7 @@
451 451  
452 452  ⑨Support direction reversal (can set the forward direction to low level)
453 453  
454 -= **7 Communication function** =
460 += **6. Communication function** =
455 455  
456 456  **~1. Communication parameter configuration**
457 457  
... ... @@ -462,27 +462,27 @@
462 462  3V settings:
463 463  
464 464  (% class="table-bordered" %)
465 -|=(% scope="row" %)**protocol**|=**D8126 value setting**
466 -|=RS instruction (custom protocol)|00H
467 -|=HMI monitoring protocol (PLC protocol)|01H
468 -|=MODBUS-RTU slave|02H
469 -|=MODBUS-ASCII slave|03H
470 -|=N:N network communication protocol slave|04H
471 -|=RS instruction (custom protocol)|10H
472 -|=MODBUS-RTU master station|20H
473 -|=MODBUS-ASCII master station|30H
474 -|=N:N network communication protocol master station|40H
471 +|**protocol**|**D8126 value setting**
472 +|RS instruction (custom protocol)|00H
473 +|HMI monitoring protocol (PLC protocol)|01H
474 +|MODBUS-RTU slave|02H
475 +|MODBUS-ASCII slave|03H
476 +|N:N network communication protocol slave|04H
477 +|RS instruction (custom protocol)|10H
478 +|MODBUS-RTU master station|20H
479 +|MODBUS-ASCII master station|30H
480 +|N:N network communication protocol master station|40H
475 475  
476 476  5V settings:
477 477  
478 478  (% class="table-bordered" %)
479 -|=(% scope="row" %)**SD2592 value setting**|=**Protocol**
480 -|=0 H|Wecon Modbus slave
481 -|=2 H|ModbusRTU slave
482 -|=3 H|ModbusASCII slave
483 -|=10 H|User-defined protocol
484 -|=20 H|ModbusRTU master station
485 -|=30 H|(((
485 +|**SD2592 value setting**|**Protocol**
486 +|0 H|Wecon Modbus slave
487 +|2 H|ModbusRTU slave
488 +|3 H|ModbusASCII slave
489 +|10 H|User-defined protocol
490 +|20 H|ModbusRTU master station
491 +|30 H|(((
486 486  ModbusASCII master
487 487  
488 488  
... ... @@ -499,31 +499,34 @@
499 499  5V address:
500 500  
501 501  (% class="table-bordered" %)
502 -|=(% scope="row" %)Port|=Occupy|=(% style="width: 240px;" %)Address range|=(% style="width: 221px;" %)(((
508 +|Port|Occupy|(% style="width:240px" %)Address range|(% style="width:221px" %)(((
503 503  10 hex Register
504 -)))|=(((
510 +)))|(((
505 505  Total reserved land Address size
506 506  )))
507 -|=**Word address**| |(% style="width:240px" %) |(% style="width:221px" %) |
508 -|=T0~~T511|512 WORD|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %)0|1536
509 -|=C0~~C255|256 WORD|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024
510 -|=LC0~~LC255|512 WORD|(% style="width:240px" %)0x0A00-0x0BFF|(% style="width:221px" %)2560|1024
511 -|=HSC0~~HSC15|128 WORD|(% style="width:240px" %)0x0E00-0x0E1F|(% style="width:221px" %)3584|512
512 -|=D0~~D7999|8000 WORD|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384
513 -|=SD0~~SD4095|4096 WORD|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288
514 -|=R0~~R30000|30000 WORD|(% style="width:240px" %)0x8000-0xF52F|(% style="width:221px" %)32768|30000
515 -|=**Bit address**| |(% style="width:240px" %) |(% style="width:221px" %) |
516 -|=T0~~T511|512 bit|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %) |1536
517 -|=C0~~C255|256 bit|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024
518 -|=LC0~~LC255|256 bit|(% style="width:240px" %)0x0A00-0x0AFF|(% style="width:221px" %)2560|1024
519 -|=HSC0~~HSC15|64 bit|(% style="width:240px" %)0x0E00-0x0E0F|(% style="width:221px" %)3584|512
520 -|=M0~~M8000|8192bit|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384
521 -|=SM0~~SM4095|4096bit|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288
522 -|=Reserved| |(% style="width:240px" %)0x8000-0xBFFF|(% style="width:221px" %) |16383
523 -|=S0~~S4095|4096bit|(% style="width:240px" %)0xC000-0xCFFF|(% style="width:221px" %)49152|8192
524 -|=X0~~X1023|1024bit|(% style="width:240px" %)0xE000-0xE3FF|(% style="width:221px" %)57344|4096
525 -|=Y0~~Y1023|1024bit|(% style="width:240px" %)0xF000-0xF3FF|(% style="width:221px" %)61440|4096
513 +|**Word address**| |(% style="width:240px" %) |(% style="width:221px" %) |
514 +|T0~~T511|512 WORD|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %)0|1536
515 +|C0~~C255|256 WORD|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024
516 +|LC0~~LC255|512 WORD|(% style="width:240px" %)0x0A00-0x0BFF|(% style="width:221px" %)2560|1024
517 +|HSC0~~HSC15|128 WORD|(% style="width:240px" %)0x0E00-0x0E1F|(% style="width:221px" %)3584|512
518 +|D0~~D7999|8000 WORD|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384
519 +|SD0~~SD4095|4096 WORD|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288
520 +|R0~~R30000|30000 WORD|(% style="width:240px" %)0x8000-0xF52F|(% style="width:221px" %)32768|30000
521 +|**Bit address**| |(% style="width:240px" %) |(% style="width:221px" %) |
522 +|T0~~T511|512 bit|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %) |1536
523 +|C0~~C255|256 bit|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024
524 +|LC0~~LC255|256 bit|(% style="width:240px" %)0x0A00-0x0AFF|(% style="width:221px" %)2560|1024
525 +|HSC0~~HSC15|64 bit|(% style="width:240px" %)0x0E00-0x0E0F|(% style="width:221px" %)3584|512
526 +|M0~~M8000|8192bit|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384
527 +|SM0~~SM4095|4096bit|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288
528 +|Reserved| |(% style="width:240px" %)0x8000-0xBFFF|(% style="width:221px" %) |16383
529 +|S0~~S4095|4096bit|(% style="width:240px" %)0xC000-0xCFFF|(% style="width:221px" %)49152|8192
530 +|X0~~X1023|1024bit|(% style="width:240px" %)0xE000-0xE3FF|(% style="width:221px" %)57344|4096
531 +|Y0~~Y1023|1024bit|(% style="width:240px" %)0xF000-0xF3FF|(% style="width:221px" %)61440|4096
526 526  
527 527  **5. LX5V added functions**
528 528  
529 529  Modify serial communication parameters during RUN. For example, use PROTOCOL instruction to modify the protocol during run. The corresponding instruction description can also find the method of setting without instruction. For details, please refer to the relevant instructions of the instruction. Commands are PROTOCOL (set serial port protocol), PROTPARA (set serial port parameters), STATION (set station number)
536 +
537 +
538 +
image-20220614151005-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Jim
Size
... ... @@ -1,1 +1,0 @@
1 -25.3 KB
Content
image-20220614151015-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Jim
Size
... ... @@ -1,1 +1,0 @@
1 -25.3 KB
Content