Changes for page 17 LX3V/5V/5S comparsion

Last modified by Jim on 2025/02/11 11:34

From version 26.1
edited by Jim
on 2022/12/07 11:00
Change comment: There is no comment for this version
To version 32.1
edited by Mora Zhou
on 2023/09/08 17:38
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Jim
1 +XWiki.Mora
Content
... ... @@ -8,7 +8,6 @@
8 8  1616;2416;2424;3624;|0806;1208;1212;1412;
9 9  1616;2416;2424;3624;
10 10  |=Programming|(% colspan="3" %)Ladder
11 -|=Type of instruction| | |
12 12  |=Execute Time|Basic 0.01-0.03μs|Basic 0.03-0.08μs|Basic 0.06μs/Applied instruction:1-10us
13 13  |=Program Capacity|(% colspan="2" %)512KB|16k
14 14  |=High Speed Pulse Output|≤1412MT and smaller: 4*200KHz;
... ... @@ -46,7 +46,7 @@
46 46  |=Expansion Module|(% colspan="2" %)yes √ (1212 and bigger can support)|yes √ (1212 and bigger can support)
47 47  |=Electronic CAM|√(2 sheets for switch)|√(2 sheets for switch)|N/A
48 48  |=S-type CAM|√|√|N/A
49 -|=N:N Comm|√|√|N/A
48 +|=PLClink|√|√|N/A
50 50  |=Linear Interpolation|√|√|N/A
51 51  |=Circular Interpolation|√|√|N/A
52 52  |=sub-rotine|√|√|N/A
... ... @@ -61,21 +61,21 @@
61 61  
62 62  **5S is as below**
63 63  
64 -[[image:image-20220614151015-2.png]]
63 +[[image:企业微信截图_16762524911554.png]]
65 65  
66 66  **More detail information,please check the product catalog**
67 67  
68 68  = **3** **Functions that 3V has but 5V does not** =
69 69  
70 -== **BD board** ==
69 +== **BD module** ==
71 71  
72 72  LX5V does not support LX3V-2RS485-BD
73 73  
74 74  LX5V does not support LX3V-ETH-BD
75 75  
76 -== **Analog BD board expansion address** ==
75 +== **Analog BD module expansion address** ==
77 77  
78 -Provides the function of analog board BD to modify parameters such as filtering. For specific functions, please refer to the below link:
77 +Provides the function of analog module BD to modify parameters such as filtering. For specific functions, please refer to the below link:
79 79  ~1. LX3 series: [[5-9 System-special address - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor/05%20Registers/5-9%20system-special%20address/#HCOM1communicationsettings26BDmoduleconfiguration]]
80 80  2. LX5 series: [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule]] [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule-1]]
81 81  
... ... @@ -346,13 +346,13 @@
346 346  (% class="table-bordered" %)
347 347  |=(% scope="row" %)**3V**|=**Description**|=**5V**|=**Description**
348 348  |=M8145|Y000 pulse output stop|SM898|Y000 pulse output stop
349 -|=M8146|Y001 Pulse output stop|SM958|Y001 Pulse output stop
348 +|=M8146|Y001 pulse output stop|SM958|Y001 Pulse output stop
350 350  |=M8152|Y002 pulse output stop|SM1018|Y002 pulse output stop
351 -|=M8153|Y003 Pulse output stop|SM1078|Y003 Pulse output stop
350 +|=M8153|Y003 pulse output stop|SM1078|Y003 Pulse output stop
352 352  |=M8147|Y000 monitoring during pulse output|SM880|Y000 monitoring during pulse output
353 -|=M8148|Y001 Monitoring during pulse output|SM940|Y001 Monitoring during pulse output
354 -|=M8149|Y002 Monitoring during pulse output|SM1000|Y002 Monitoring during pulse output
355 -|=M8150|Y003 Monitoring during pulse output|SM1060|Y003 Monitoring during pulse output
352 +|=M8148|Y001 monitoring during pulse output|SM940|Y001 Monitoring during pulse output
353 +|=M8149|Y002 monitoring during pulse output|SM1000|Y002 Monitoring during pulse output
354 +|=M8150|Y003 monitoring during pulse output|SM1060|Y003 Monitoring during pulse output
356 356  |=(% rowspan="4" %)(((
357 357  
358 358  
... ... @@ -372,8 +372,8 @@
372 372  )))|(((
373 373  SM957
374 374  )))|Y1 Perimeter control bit
375 -|=M8136|Y2 Perimeter control bit|SM1017|Y2 Perimeter control bit
376 -|=M8137|Y3 Perimeter control bit|SM1077|Y3 Perimeter control bit
374 +|=M8136|Y2 perimeter control bit|SM1017|Y2 Perimeter control bit
375 +|=M8137|Y3 perimeter control bit|SM1077|Y3 Perimeter control bit
377 377  
378 378  3. Comparison of word devices
379 379  
... ... @@ -383,14 +383,14 @@
383 383  |=D8105|Y1 acceleration and deceleration time (open M8135)|SD1022/SD1082|Y1 acceleration/deceleration time
384 384  |=D8106|Y2 acceleration and deceleration time (open M8135)|SD1142/SD1202|Y2 acceleration/deceleration time
385 385  |=D8107|Y3 acceleration and deceleration time (open M8135)|SD1262/SD1322|Y3 acceleration/deceleration time
386 -|=D8140|Y000 Current position low|SD880|Y000 Current position low
385 +|=D8140|Y000 current position low|SD880|Y000 Current position low
387 387  |=D8141|Y000 current position high|SD881|Y000 current position high
388 -|=D8142|Y001 Current position low|SD940|Y001 Current position low
389 -|=D8143|Y001 Current position high|SD941|Y001 Current position high
387 +|=D8142|Y001 current position low|SD940|Y001 Current position low
388 +|=D8143|Y001 current position high|SD941|Y001 Current position high
390 390  |=D8150|Y002 current position low|SD1000|Y002 current position low
391 391  |=D8151|Y002 current position high|SD1001|Y002 current position high
392 -|=D8152|Y003 Current position low|SD1060|Y003 Current position low
393 -|=D8153|Y003 Current position high|SD1061|Y003 Current position high
391 +|=D8152|Y003 current position low|SD1060|Y003 Current position low
392 +|=D8153|Y003 current position high|SD1061|Y003 Current position high
394 394  |=(% rowspan="4" %)(((
395 395  
396 396  
... ... @@ -400,7 +400,7 @@
400 400  
401 401  
402 402  
403 -Y0-Y3 Paranoid speed (single word)
402 +Y0-Y3 paranoid speed (single word)
404 404  )))|SD900, SD901|Y0 Paranoid speed (double word)
405 405  |=SD960, SD961|Y1 Paranoid speed (double word)
406 406  |=SD1020, SD1021|Y2 Paranoid speed (double word)
企业微信截图_16762524911554.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Jim
Size
... ... @@ -1,0 +1,1 @@
1 +20.4 KB
Content