Changes for page 17 LX3V/5V/5S comparsion
Last modified by Jim on 2025/02/11 11:34
Summary
-
Page properties (4 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - 17LX3V/5V/5Scomparsion1 +03 Difference between 3V, 5V and 5S - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PLC Editor2.WebHome 1 +PLC Editor2.1 User manual.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Jim1 +XWiki.admin - Content
-
... ... @@ -1,4 +1,4 @@ 1 -= **1 Basic difference s** =1 += **1 Basic difference between 3V, 5V and 5S** = 2 2 3 3 |=(% scope="row" %)Functions|=5V|=5S|=3V 4 4 |=Running Mode|(% colspan="3" %)Cyclic scan /Interrupt ... ... @@ -8,6 +8,7 @@ 8 8 1616;2416;2424;3624;|0806;1208;1212;1412; 9 9 1616;2416;2424;3624; 10 10 |=Programming|(% colspan="3" %)Ladder 11 +|=Type of instruction| | | 11 11 |=Execute Time|Basic 0.01-0.03μs|Basic 0.03-0.08μs|Basic 0.06μs/Applied instruction:1-10us 12 12 |=Program Capacity|(% colspan="2" %)512KB|16k 13 13 |=High Speed Pulse Output|≤1412MT and smaller: 4*200KHz; ... ... @@ -18,22 +18,10 @@ 18 18 |=X Interrupt|X0-X7 Rising & Falling|X0-X5 Rising & Falling|X0-X5 Rising & Falling 19 19 |=**High speed counter Single Phase**|**≤1412 and smaller: 4*150KHz 20 20 ≥1616 and bigger: 8*150KHz**|**≤1412 and smaller: 2*150KHz;4*10KHz 21 -≥1616 and bigger: 6*150KHz**|((( 22 -**Hardware counter for the first two channels:2*200KHz;** 23 - 24 -**Software counter for the first two channels:2*100KHz;** 25 - 26 -**Software counter for back four channels:4*10KHz** 27 -))) 22 +≥1616 and bigger: 6*150KHz**|**2*200KHz; 4*10KHz** 28 28 |=**High speed counter AB phase**|**≤1412 and smaller: 4*100KHz 29 29 ≥1616 and bigger: 8*100KHz**|**≤1412 and smaller: 1*100KHz+2*10KHz 30 -≥1616 and bigger: 3*100KHz**|((( 31 -**Hardware counter for the first two channels:2*100KHz;** 32 - 33 -**Software counter for the first two channels:2*50KHz;** 34 - 35 -**Software counter for back four channels:4*5KHz** 36 -))) 25 +≥1616 and bigger: 3*100KHz**|**2*100KHz** 37 37 |=Storage Type|(% colspan="3" %)FLASH 38 38 |=Serial Communication|((( 39 39 COM1: RS422、RS485;COM2: RS485 ... ... @@ -41,18 +41,19 @@ 41 41 1212 and bigger: COM1: RS422、RS485;COM2:RS485|1208 and smaller: COM1: RS422;COM2: RS485; 42 42 1212 and bigger: COM1: RS422、RS485;COM2: RS485 43 43 |=BD board support|yes|yes|yes 44 -|=Communication BD board|(% colspan="2" %) supportLX5V-2RS485-BD andLX5V-ETH-BD|RS485 BD support, 3vp supports ethernet bd board33 +|=Communication BD board|(% colspan="2" %)inbuilt ethernet port series, RS485 BD board in developing |RS485 BD support, 3vp supports ethernet bd board 45 45 |=Expansion Module|(% colspan="2" %)yes √ (1212 and bigger can support)|yes √ (1212 and bigger can support) 46 46 |=Electronic CAM|√(2 sheets for switch)|√(2 sheets for switch)|N/A 47 47 |=S-type CAM|√|√|N/A 48 -|= PLClink|√|√|N/A37 +|=N:N Comm|√|√|N/A 49 49 |=Linear Interpolation|√|√|N/A 50 50 |=Circular Interpolation|√|√|N/A 51 51 |=sub-rotine|√|√|N/A 41 +|= | | | 52 52 53 -= **2 Software difference between 5S vs5V** =43 += **2 Software interface difference between 5S and 5V** = 54 54 55 -== **High speed counter configuration** == 45 +== **2.1 High speed counter configuration** == 56 56 57 57 **5V as below** 58 58 ... ... @@ -60,29 +60,29 @@ 60 60 61 61 **5S is as below** 62 62 63 -[[image: 企业微信截图_16762524911554.png]]53 +[[image:image-20220614151015-2.png]] 64 64 65 65 **More detail information,please check the product catalog** 66 66 67 67 = **3** **Functions that 3V has but 5V does not** = 68 68 69 -== **BD board** == 59 +== **3.1 BD board** == 70 70 71 -LX5V does not support LX3V-2RS485-BD61 +LX5V does not support RS485 BD 72 72 73 -LX5V does not support LX3V-ETH-BD63 +LX5V does not support Ethernet BD 74 74 75 - ==**AnalogBD boardexpansion address**==65 +LX5V does not support CAN BD 76 76 77 -Provides the function of analog board BD to modify parameters such as filtering. For specific functions, please refer to the below link: 78 -~1. LX3 series: [[5-9 System-special address - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor/05%20Registers/5-9%20system-special%20address/#HCOM1communicationsettings26BDmoduleconfiguration]] 79 -2. LX5 series: [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule]] [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule-1]] 67 +== **3.2 Analog BD board expansion address** == 80 80 81 - == **PLDID**==69 +Provides the function of analog board BD to modify parameters such as filtering. For specific functions, please refer to the BD board manual. 82 82 71 +== **3.3 PLDID** == 72 + 83 83 Program label function, when the label of the program corresponds to the label of the PLC, the ladder diagram can be uploaded and downloaded. Clearing the memory does not clear this tag either. It is mainly to limit the ladder diagram used by PLC. 84 84 85 -== **Instructions** == 75 +== **3.4 Instructions** == 86 86 87 87 (1) NOP instruction (null instruction) 88 88 ... ... @@ -106,9 +106,9 @@ 106 106 107 107 (11) CPAVL instruction(communication BD configuration) 108 108 109 -== **Unsupported special register function (M8000, D8000)** == 99 +== **3.5 Unsupported special register function (M8000, D8000)** == 110 110 111 -=== **Clock related** === 101 +=== **3.5.1 Clock related** === 112 112 113 113 Clock function not supported by LX5V 114 114 ... ... @@ -119,12 +119,12 @@ 119 119 |=M8018|install and examine 120 120 |=M8019|Real-time clock (RTC) error 121 121 122 -=== **High-speed counter ring counting function** === 112 +=== **3.5.2 High-speed counter ring counting function** === 123 123 124 124 |=M8099|High-speed ring counter count start 125 125 |=M8099|Ring count configuration 126 126 127 -=== **X0~~X5 pulse capture function** === 117 +=== **3.5.3 X0~~X5 pulse capture function** === 128 128 129 129 |=M8170|X000 pulse capture 130 130 |=M8171|X001 pulse capture ... ... @@ -133,13 +133,16 @@ 133 133 |=M8174|X004 pulse capture 134 134 |=M8175|X005 pulse capture 135 135 136 -= **4 3V and5Vincompatiblefunctions** =126 += **4. 5V function under development** = 137 137 138 -(% class="wikigeneratedid" %) 139 -**(These can be automatically converted in the future)** 128 +N:N communication protocol 140 140 141 - == **Generalregister**==130 +Interpolation instructions (G90G01, G90G02, G90G03, G91G01, G91G02, G91G03) 142 142 132 += **5. 3V and 5V incompatible functions (These can be automatically converted in the future)** = 133 + 134 +== **5.1 General register** == 135 + 143 143 (% class="table-bordered" %) 144 144 |=(% scope="row" %)**register**|=**LX3V**|=**LX5V**|=**Remarks** 145 145 |=Input|X0~~X377|X0~~X1777| ... ... @@ -168,13 +168,10 @@ 168 168 169 169 5. Pointer I is cancelled in LX5V, please check the programming mode for details. 170 170 171 -== **Programming method** == 164 +== **5.2 Programming method** == 172 172 173 -=== **Subroutine** === 166 +=== **5.2.1 Subroutine (For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)** === 174 174 175 -(% class="wikigeneratedid" %) 176 -**(For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)** 177 - 178 178 **Use of LX3V subroutines** 179 179 [[image:1652684087594-147.png]] 180 180 ... ... @@ -188,11 +188,8 @@ 188 188 189 189 [[image:1652684829740-769.png]] 190 190 191 -=== **Interrupt** === 181 +=== **5.2.2 Interrupt (For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)** === 192 192 193 -(% class="wikigeneratedid" %) 194 -**(For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)** 195 - 196 196 **LX3V interrupt** 197 197 198 198 The interrupt program is under FEND and returns with IRET. The meaning of the specific interrupt is distinguished by the pointer I number.(Refer to EI/DI instruction in 3V) ... ... @@ -211,9 +211,9 @@ 211 211 212 212 [[image:1652685809566-630.png]] 213 213 214 -=== **Instructions** === 201 +=== **5.2.3 Instructions** === 215 215 216 -**OUT instruction**203 +**OUT command** 217 217 218 218 Double word counter[[image:file:///C:\Users\ANNAXU~~1\AppData\Local\Temp\ksohtml14432\wps28.png]] 219 219 ... ... @@ -279,9 +279,9 @@ 279 279 280 280 [[image:1652689626279-240.png]] 281 281 282 -= ** 5High-speed input function** =269 += **6. High-speed input function** = 283 283 284 -== **Use on LX3V** == 271 +== **6.1 Use on LX3V** == 285 285 286 286 Find the high-speed input counter you need to use according to the following table: 287 287 ... ... @@ -293,7 +293,7 @@ 293 293 294 294 [[image:1652690126303-800.png]] 295 295 296 -== **Use on LX5V** == 283 +== **6.2 Use on LX5V** == 297 297 298 298 According to channel, select the HSC register to use: 299 299 ... ... @@ -307,10 +307,11 @@ 307 307 308 308 [[image:1652692388207-617.png]] 309 309 310 -== **Difference between high-speed counters on LX5V and LX3V** == 297 +== **6.3 Difference between high-speed counters on LX5V and LX3V** == 311 311 312 312 LX3V updates the count value when the OUT instruction is executed, which is affected by the scan cycle. 313 313 301 + 314 314 LX5V is updated in the 100us interrupt, not affected by the scan cycle, and provides the REF instruction to refresh the current high-speed counter value immediately. 315 315 316 316 LX5V single-phase high-speed counter supports filtering function, configurable 0~~17us. ... ... @@ -317,7 +317,7 @@ 317 317 318 318 LX5V high-speed input counter will update the input frequency in the special soft element (SD) every 100us. 319 319 320 -= ** 6High-speed output function** =308 += **7. High-speed output function** = 321 321 322 322 **High-speed pulse commands are the same in the use of commands.** 323 323 ... ... @@ -464,7 +464,7 @@ 464 464 465 465 ⑨Support direction reversal (can set the forward direction to low level) 466 466 467 -= ** 7Communication function** =455 += **8. Communication function** = 468 468 469 469 **~1. Communication parameter configuration** 470 470 ... ... @@ -540,3 +540,6 @@ 540 540 **5. LX5V added functions** 541 541 542 542 Modify serial communication parameters during RUN. For example, use PROTOCOL instruction to modify the protocol during run. The corresponding instruction description can also find the method of setting without instruction. For details, please refer to the relevant instructions of the instruction. Commands are PROTOCOL (set serial port protocol), PROTPARA (set serial port parameters), STATION (set station number) 531 + 532 + 533 +
- 企业微信截图_16762524911554.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Jim - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.4 KB - Content