Changes for page 17 LX3V/5V/5S comparsion

Last modified by Jim on 2025/02/11 11:34

From version 29.2
edited by Karen
on 2023/05/30 11:46
Change comment: There is no comment for this version
To version 12.1
edited by Leo Wei
on 2022/06/14 15:31
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -17 LX3V/5V/5S comparsion
1 +03 Difference between 3V, 5V and 5S
Parent
... ... @@ -1,1 +1,1 @@
1 -PLC Editor2.WebHome
1 +PLC Editor2.1 User manual.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Karen
1 +XWiki.admin
Content
... ... @@ -1,4 +1,4 @@
1 -= **1 Basic differences** =
1 += **1 Basic difference between 3V, 5V and 5S** =
2 2  
3 3  |=(% scope="row" %)Functions|=5V|=5S|=3V
4 4  |=Running Mode|(% colspan="3" %)Cyclic scan /Interrupt
... ... @@ -8,6 +8,7 @@
8 8  1616;2416;2424;3624;|0806;1208;1212;1412;
9 9  1616;2416;2424;3624;
10 10  |=Programming|(% colspan="3" %)Ladder
11 +|=Type of instruction| | |
11 11  |=Execute Time|Basic 0.01-0.03μs|Basic 0.03-0.08μs|Basic 0.06μs/Applied instruction:1-10us
12 12  |=Program Capacity|(% colspan="2" %)512KB|16k
13 13  |=High Speed Pulse Output|≤1412MT and smaller: 4*200KHz;
... ... @@ -18,22 +18,10 @@
18 18  |=X Interrupt|X0-X7 Rising & Falling|X0-X5 Rising & Falling|X0-X5 Rising & Falling
19 19  |=**High speed counter Single Phase**|**≤1412 and smaller: 4*150KHz
20 20  ≥1616 and bigger: 8*150KHz**|**≤1412 and smaller: 2*150KHz;4*10KHz
21 -≥1616 and bigger: 6*150KHz**|(((
22 -**Hardware counter for the first two channels:2*200KHz;**
23 -
24 -**Software counter for the first two channels:2*100KHz;**
25 -
26 -**Software counter for back four channels:4*10KHz**
27 -)))
22 +≥1616 and bigger: 6*150KHz**|**2*200KHz; 4*10KHz**
28 28  |=**High speed counter AB phase**|**≤1412 and smaller: 4*100KHz
29 29  ≥1616 and bigger: 8*100KHz**|**≤1412 and smaller: 1*100KHz+2*10KHz
30 -≥1616 and bigger: 3*100KHz**|(((
31 -**Hardware counter for the first two channels:2*100KHz;**
32 -
33 -**Software counter for the first two channels:2*50KHz;**
34 -
35 -**Software counter for back four channels:4*5KHz**
36 -)))
25 +≥1616 and bigger: 3*100KHz**|**2*100KHz**
37 37  |=Storage Type|(% colspan="3" %)FLASH
38 38  |=Serial Communication|(((
39 39  COM1: RS422、RS485;COM2: RS485
... ... @@ -41,18 +41,19 @@
41 41  1212 and bigger: COM1: RS422、RS485;COM2:RS485|1208 and smaller: COM1: RS422;COM2: RS485;
42 42  1212 and bigger: COM1: RS422、RS485;COM2: RS485
43 43  |=BD board support|yes|yes|yes
44 -|=Communication BD board|(% colspan="2" %)support LX5V-2RS485-BD and LX5V-ETH-BD|RS485 BD support, 3vp supports ethernet bd board
33 +|=Communication BD board|(% colspan="2" %)inbuilt ethernet port series, RS485 BD board in developing |RS485 BD support, 3vp supports ethernet bd board
45 45  |=Expansion Module|(% colspan="2" %)yes √ (1212 and bigger can support)|yes √ (1212 and bigger can support)
46 46  |=Electronic CAM|√(2 sheets for switch)|√(2 sheets for switch)|N/A
47 47  |=S-type CAM|√|√|N/A
48 -|=PLClink|√|√|N/A
37 +|=N:N Comm|√|√|N/A
49 49  |=Linear Interpolation|√|√|N/A
50 50  |=Circular Interpolation|√|√|N/A
51 51  |=sub-rotine|√|√|N/A
41 +|= | | |
52 52  
53 -= **2 Software difference between 5S vs 5V** =
43 += **2 Software interface difference between 5S and 5V** =
54 54  
55 -== **High speed counter configuration** ==
45 +== **2.1 High speed counter configuration** ==
56 56  
57 57  **5V as below**
58 58  
... ... @@ -60,29 +60,29 @@
60 60  
61 61  **5S is as below**
62 62  
63 -[[image:企业微信截图_16762524911554.png]]
53 +[[image:image-20220614151015-2.png]]
64 64  
65 65  **More detail information,please check the product catalog**
66 66  
67 67  = **3** **Functions that 3V has but 5V does not** =
68 68  
69 -== **BD module** ==
59 +== **3.1 BD board** ==
70 70  
71 -LX5V does not support LX3V-2RS485-BD
61 +LX5V does not support RS485 BD
72 72  
73 -LX5V does not support LX3V-ETH-BD
63 +LX5V does not support Ethernet BD
74 74  
75 -== **Analog BD board expansion address** ==
65 +LX5V does not support CAN BD
76 76  
77 -Provides the function of analog board BD to modify parameters such as filtering. For specific functions, please refer to the below link:
78 -~1. LX3 series: [[5-9 System-special address - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor/05%20Registers/5-9%20system-special%20address/#HCOM1communicationsettings26BDmoduleconfiguration]]
79 -2. LX5 series: [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule]] [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule-1]]
67 +== **3.2 Analog BD board expansion address** ==
80 80  
81 -== **PLDID** ==
69 +Provides the function of analog board BD to modify parameters such as filtering. For specific functions, please refer to the BD board manual.
82 82  
71 +== **3.3 PLDID** ==
72 +
83 83  Program label function, when the label of the program corresponds to the label of the PLC, the ladder diagram can be uploaded and downloaded. Clearing the memory does not clear this tag either. It is mainly to limit the ladder diagram used by PLC.
84 84  
85 -== **Instructions** ==
75 +== **3.4 Instructions** ==
86 86  
87 87  (1) NOP instruction (null instruction)
88 88  
... ... @@ -106,9 +106,9 @@
106 106  
107 107  (11) CPAVL instruction(communication BD configuration)
108 108  
109 -== **Unsupported special register function (M8000, D8000)** ==
99 +== **3.5 Unsupported special register function (M8000, D8000)** ==
110 110  
111 -=== **Clock related** ===
101 +=== **3.5.1 Clock related** ===
112 112  
113 113  Clock function not supported by LX5V
114 114  
... ... @@ -119,12 +119,12 @@
119 119  |=M8018|install and examine
120 120  |=M8019|Real-time clock (RTC) error
121 121  
122 -=== **High-speed counter ring counting function** ===
112 +=== **3.5.2 High-speed counter ring counting function** ===
123 123  
124 124  |=M8099|High-speed ring counter count start
125 125  |=M8099|Ring count configuration
126 126  
127 -=== **X0~~X5 pulse capture function** ===
117 +=== **3.5.3 X0~~X5 pulse capture function** ===
128 128  
129 129  |=M8170|X000 pulse capture
130 130  |=M8171|X001 pulse capture
... ... @@ -133,13 +133,16 @@
133 133  |=M8174|X004 pulse capture
134 134  |=M8175|X005 pulse capture
135 135  
136 -= **4 3V and 5V incompatible functions** =
126 += **4. 5V function under development** =
137 137  
138 -(% class="wikigeneratedid" %)
139 -**(These can be automatically converted in the future)**
128 +N:N communication protocol
140 140  
141 -== **General register** ==
130 +Interpolation instructions (G90G01, G90G02, G90G03, G91G01, G91G02, G91G03)
142 142  
132 += **5. 3V and 5V incompatible functions (These can be automatically converted in the future)** =
133 +
134 +== **5.1 General register** ==
135 +
143 143  (% class="table-bordered" %)
144 144  |=(% scope="row" %)**register**|=**LX3V**|=**LX5V**|=**Remarks**
145 145  |=Input|X0~~X377|X0~~X1777|
... ... @@ -168,13 +168,10 @@
168 168  
169 169  5. Pointer I is cancelled in LX5V, please check the programming mode for details.
170 170  
171 -== **Programming method** ==
164 +== **5.2 Programming method** ==
172 172  
173 -=== **Subroutine** ===
166 +=== **5.2.1 Subroutine (For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)** ===
174 174  
175 -(% class="wikigeneratedid" %)
176 -**(For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)**
177 -
178 178  **Use of LX3V subroutines**
179 179  [[image:1652684087594-147.png]]
180 180  
... ... @@ -188,11 +188,8 @@
188 188  
189 189  [[image:1652684829740-769.png]]
190 190  
191 -=== **Interrupt** ===
181 +=== **5.2.2 Interrupt (For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)** ===
192 192  
193 -(% class="wikigeneratedid" %)
194 -**(For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)**
195 -
196 196  **LX3V interrupt**
197 197  
198 198  The interrupt program is under FEND and returns with IRET. The meaning of the specific interrupt is distinguished by the pointer I number.(Refer to EI/DI instruction in 3V)
... ... @@ -211,9 +211,9 @@
211 211  
212 212  [[image:1652685809566-630.png]]
213 213  
214 -=== **Instructions** ===
201 +=== **5.2.3 Instructions** ===
215 215  
216 -**OUT instruction**
203 +**OUT command**
217 217  
218 218  Double word counter[[image:file:///C:\Users\ANNAXU~~1\AppData\Local\Temp\ksohtml14432\wps28.png]]
219 219  
... ... @@ -279,9 +279,9 @@
279 279  
280 280  [[image:1652689626279-240.png]]
281 281  
282 -= **5 High-speed input function** =
269 += **6. High-speed input function** =
283 283  
284 -== **Use on LX3V** ==
271 +== **6.1 Use on LX3V** ==
285 285  
286 286  Find the high-speed input counter you need to use according to the following table:
287 287  
... ... @@ -293,7 +293,7 @@
293 293  
294 294  [[image:1652690126303-800.png]]
295 295  
296 -== **Use on LX5V** ==
283 +== **6.2 Use on LX5V** ==
297 297  
298 298  According to channel, select the HSC register to use:
299 299  
... ... @@ -307,10 +307,11 @@
307 307  
308 308  [[image:1652692388207-617.png]]
309 309  
310 -== **Difference between high-speed counters on LX5V and LX3V** ==
297 +== **6.3 Difference between high-speed counters on LX5V and LX3V** ==
311 311  
312 312  LX3V updates the count value when the OUT instruction is executed, which is affected by the scan cycle.
313 313  
301 +
314 314  LX5V is updated in the 100us interrupt, not affected by the scan cycle, and provides the REF instruction to refresh the current high-speed counter value immediately.
315 315  
316 316  LX5V single-phase high-speed counter supports filtering function, configurable 0~~17us.
... ... @@ -317,7 +317,7 @@
317 317  
318 318  LX5V high-speed input counter will update the input frequency in the special soft element (SD) every 100us.
319 319  
320 -= **6 High-speed output function** =
308 += **7. High-speed output function** =
321 321  
322 322  **High-speed pulse commands are the same in the use of commands.**
323 323  
... ... @@ -464,7 +464,7 @@
464 464  
465 465  ⑨Support direction reversal (can set the forward direction to low level)
466 466  
467 -= **7 Communication function** =
455 += **8. Communication function** =
468 468  
469 469  **~1. Communication parameter configuration**
470 470  
... ... @@ -489,13 +489,13 @@
489 489  5V settings:
490 490  
491 491  (% class="table-bordered" %)
492 -|=(% scope="row" %)**SD2592 value setting**|=**Protocol**
493 -|=0 H|Wecon Modbus slave
494 -|=2 H|ModbusRTU slave
495 -|=3 H|ModbusASCII slave
496 -|=10 H|User-defined protocol
497 -|=20 H|ModbusRTU master station
498 -|=30 H|(((
480 +|**SD2592 value setting**|**Protocol**
481 +|0 H|Wecon Modbus slave
482 +|2 H|ModbusRTU slave
483 +|3 H|ModbusASCII slave
484 +|10 H|User-defined protocol
485 +|20 H|ModbusRTU master station
486 +|30 H|(((
499 499  ModbusASCII master
500 500  
501 501  
... ... @@ -512,31 +512,34 @@
512 512  5V address:
513 513  
514 514  (% class="table-bordered" %)
515 -|=(% scope="row" %)Port|=Occupy|=(% style="width: 240px;" %)Address range|=(% style="width: 221px;" %)(((
503 +|Port|Occupy|(% style="width:240px" %)Address range|(% style="width:221px" %)(((
516 516  10 hex Register
517 -)))|=(((
505 +)))|(((
518 518  Total reserved land Address size
519 519  )))
520 -|=**Word address**| |(% style="width:240px" %) |(% style="width:221px" %) |
521 -|=T0~~T511|512 WORD|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %)0|1536
522 -|=C0~~C255|256 WORD|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024
523 -|=LC0~~LC255|512 WORD|(% style="width:240px" %)0x0A00-0x0BFF|(% style="width:221px" %)2560|1024
524 -|=HSC0~~HSC15|128 WORD|(% style="width:240px" %)0x0E00-0x0E1F|(% style="width:221px" %)3584|512
525 -|=D0~~D7999|8000 WORD|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384
526 -|=SD0~~SD4095|4096 WORD|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288
527 -|=R0~~R30000|30000 WORD|(% style="width:240px" %)0x8000-0xF52F|(% style="width:221px" %)32768|30000
528 -|=**Bit address**| |(% style="width:240px" %) |(% style="width:221px" %) |
529 -|=T0~~T511|512 bit|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %) |1536
530 -|=C0~~C255|256 bit|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024
531 -|=LC0~~LC255|256 bit|(% style="width:240px" %)0x0A00-0x0AFF|(% style="width:221px" %)2560|1024
532 -|=HSC0~~HSC15|64 bit|(% style="width:240px" %)0x0E00-0x0E0F|(% style="width:221px" %)3584|512
533 -|=M0~~M8000|8192bit|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384
534 -|=SM0~~SM4095|4096bit|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288
535 -|=Reserved| |(% style="width:240px" %)0x8000-0xBFFF|(% style="width:221px" %) |16383
536 -|=S0~~S4095|4096bit|(% style="width:240px" %)0xC000-0xCFFF|(% style="width:221px" %)49152|8192
537 -|=X0~~X1023|1024bit|(% style="width:240px" %)0xE000-0xE3FF|(% style="width:221px" %)57344|4096
538 -|=Y0~~Y1023|1024bit|(% style="width:240px" %)0xF000-0xF3FF|(% style="width:221px" %)61440|4096
508 +|**Word address**| |(% style="width:240px" %) |(% style="width:221px" %) |
509 +|T0~~T511|512 WORD|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %)0|1536
510 +|C0~~C255|256 WORD|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024
511 +|LC0~~LC255|512 WORD|(% style="width:240px" %)0x0A00-0x0BFF|(% style="width:221px" %)2560|1024
512 +|HSC0~~HSC15|128 WORD|(% style="width:240px" %)0x0E00-0x0E1F|(% style="width:221px" %)3584|512
513 +|D0~~D7999|8000 WORD|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384
514 +|SD0~~SD4095|4096 WORD|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288
515 +|R0~~R30000|30000 WORD|(% style="width:240px" %)0x8000-0xF52F|(% style="width:221px" %)32768|30000
516 +|**Bit address**| |(% style="width:240px" %) |(% style="width:221px" %) |
517 +|T0~~T511|512 bit|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %) |1536
518 +|C0~~C255|256 bit|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024
519 +|LC0~~LC255|256 bit|(% style="width:240px" %)0x0A00-0x0AFF|(% style="width:221px" %)2560|1024
520 +|HSC0~~HSC15|64 bit|(% style="width:240px" %)0x0E00-0x0E0F|(% style="width:221px" %)3584|512
521 +|M0~~M8000|8192bit|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384
522 +|SM0~~SM4095|4096bit|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288
523 +|Reserved| |(% style="width:240px" %)0x8000-0xBFFF|(% style="width:221px" %) |16383
524 +|S0~~S4095|4096bit|(% style="width:240px" %)0xC000-0xCFFF|(% style="width:221px" %)49152|8192
525 +|X0~~X1023|1024bit|(% style="width:240px" %)0xE000-0xE3FF|(% style="width:221px" %)57344|4096
526 +|Y0~~Y1023|1024bit|(% style="width:240px" %)0xF000-0xF3FF|(% style="width:221px" %)61440|4096
539 539  
540 540  **5. LX5V added functions**
541 541  
542 542  Modify serial communication parameters during RUN. For example, use PROTOCOL instruction to modify the protocol during run. The corresponding instruction description can also find the method of setting without instruction. For details, please refer to the relevant instructions of the instruction. Commands are PROTOCOL (set serial port protocol), PROTPARA (set serial port parameters), STATION (set station number)
531 +
532 +
533 +
企业微信截图_16762524911554.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Jim
Size
... ... @@ -1,1 +1,0 @@
1 -20.4 KB
Content