Changes for page 17 LX3V/5V/5S comparsion

Last modified by Jim on 2025/02/11 11:34

From version 31.1
edited by Karen
on 2023/05/30 11:47
Change comment: There is no comment for this version
To version 17.2
edited by Stone Wu
on 2022/07/13 23:55
Change comment: Update document after refactoring.

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -17 LX3V/5V/5S comparsion
1 +03 LX3V/5V/5S comparion
Parent
... ... @@ -1,1 +1,1 @@
1 -PLC Editor2.WebHome
1 +PLC Editor2.1 User manual.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Karen
1 +XWiki.Stone
Content
... ... @@ -1,4 +1,4 @@
1 -= **1 Basic differences** =
1 += **1 Basic difference between 3V, 5V and 5S** =
2 2  
3 3  |=(% scope="row" %)Functions|=5V|=5S|=3V
4 4  |=Running Mode|(% colspan="3" %)Cyclic scan /Interrupt
... ... @@ -8,6 +8,7 @@
8 8  1616;2416;2424;3624;|0806;1208;1212;1412;
9 9  1616;2416;2424;3624;
10 10  |=Programming|(% colspan="3" %)Ladder
11 +|=Type of instruction| | |
11 11  |=Execute Time|Basic 0.01-0.03μs|Basic 0.03-0.08μs|Basic 0.06μs/Applied instruction:1-10us
12 12  |=Program Capacity|(% colspan="2" %)512KB|16k
13 13  |=High Speed Pulse Output|≤1412MT and smaller: 4*200KHz;
... ... @@ -18,22 +18,10 @@
18 18  |=X Interrupt|X0-X7 Rising & Falling|X0-X5 Rising & Falling|X0-X5 Rising & Falling
19 19  |=**High speed counter Single Phase**|**≤1412 and smaller: 4*150KHz
20 20  ≥1616 and bigger: 8*150KHz**|**≤1412 and smaller: 2*150KHz;4*10KHz
21 -≥1616 and bigger: 6*150KHz**|(((
22 -**Hardware counter for the first two channels:2*200KHz;**
23 -
24 -**Software counter for the first two channels:2*100KHz;**
25 -
26 -**Software counter for back four channels:4*10KHz**
27 -)))
22 +≥1616 and bigger: 6*150KHz**|**2*200KHz; 4*10KHz**
28 28  |=**High speed counter AB phase**|**≤1412 and smaller: 4*100KHz
29 29  ≥1616 and bigger: 8*100KHz**|**≤1412 and smaller: 1*100KHz+2*10KHz
30 -≥1616 and bigger: 3*100KHz**|(((
31 -**Hardware counter for the first two channels:2*100KHz;**
32 -
33 -**Software counter for the first two channels:2*50KHz;**
34 -
35 -**Software counter for back four channels:4*5KHz**
36 -)))
25 +≥1616 and bigger: 3*100KHz**|**2*100KHz**
37 37  |=Storage Type|(% colspan="3" %)FLASH
38 38  |=Serial Communication|(((
39 39  COM1: RS422、RS485;COM2: RS485
... ... @@ -41,16 +41,16 @@
41 41  1212 and bigger: COM1: RS422、RS485;COM2:RS485|1208 and smaller: COM1: RS422;COM2: RS485;
42 42  1212 and bigger: COM1: RS422、RS485;COM2: RS485
43 43  |=BD board support|yes|yes|yes
44 -|=Communication BD board|(% colspan="2" %)support LX5V-2RS485-BD and LX5V-ETH-BD|RS485 BD support, 3vp supports ethernet bd board
33 +|=Communication BD board|(% colspan="2" %)inbuilt ethernet port series, RS485 BD board in developing |RS485 BD support, 3vp supports ethernet bd board
45 45  |=Expansion Module|(% colspan="2" %)yes √ (1212 and bigger can support)|yes √ (1212 and bigger can support)
46 46  |=Electronic CAM|√(2 sheets for switch)|√(2 sheets for switch)|N/A
47 47  |=S-type CAM|√|√|N/A
48 -|=PLClink|√|√|N/A
37 +|=N:N Comm|√|√|N/A
49 49  |=Linear Interpolation|√|√|N/A
50 50  |=Circular Interpolation|√|√|N/A
51 51  |=sub-rotine|√|√|N/A
52 52  
53 -= **2 Software difference between 5S vs 5V** =
42 += **2 Software interface difference between 5S and 5V** =
54 54  
55 55  == **High speed counter configuration** ==
56 56  
... ... @@ -60,24 +60,24 @@
60 60  
61 61  **5S is as below**
62 62  
63 -[[image:企业微信截图_16762524911554.png]]
52 +[[image:image-20220614151015-2.png]]
64 64  
65 65  **More detail information,please check the product catalog**
66 66  
67 67  = **3** **Functions that 3V has but 5V does not** =
68 68  
69 -== **BD module** ==
58 +== **BD board** ==
70 70  
71 -LX5V does not support LX3V-2RS485-BD
60 +LX5V does not support RS485 BD
72 72  
73 -LX5V does not support LX3V-ETH-BD
62 +LX5V does not support Ethernet BD
74 74  
75 -== **Analog BD module expansion address** ==
64 +LX5V does not support CAN BD
76 76  
77 -Provides the function of analog module BD to modify parameters such as filtering. For specific functions, please refer to the below link:
78 -~1. LX3 series: [[5-9 System-special address - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor/05%20Registers/5-9%20system-special%20address/#HCOM1communicationsettings26BDmoduleconfiguration]]
79 -2. LX5 series: [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule]] [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule-1]]
66 +== **Analog BD board expansion address** ==
80 80  
68 +Provides the function of analog board BD to modify parameters such as filtering. For specific functions, please refer to the BD board manual.
69 +
81 81  == **PLDID** ==
82 82  
83 83  Program label function, when the label of the program corresponds to the label of the PLC, the ladder diagram can be uploaded and downloaded. Clearing the memory does not clear this tag either. It is mainly to limit the ladder diagram used by PLC.
... ... @@ -133,8 +133,14 @@
133 133  |=M8174|X004 pulse capture
134 134  |=M8175|X005 pulse capture
135 135  
136 -= **4 3V and 5V incompatible functions** =
125 += **4 5V function under development** =
137 137  
127 +N:N communication protocol
128 +
129 +Interpolation instructions (G90G01, G90G02, G90G03, G91G01, G91G02, G91G03)
130 +
131 += **5 3V and 5V incompatible functions** =
132 +
138 138  (% class="wikigeneratedid" %)
139 139  **(These can be automatically converted in the future)**
140 140  
... ... @@ -279,7 +279,7 @@
279 279  
280 280  [[image:1652689626279-240.png]]
281 281  
282 -= **5 High-speed input function** =
277 += **6 High-speed input function** =
283 283  
284 284  == **Use on LX3V** ==
285 285  
... ... @@ -317,7 +317,7 @@
317 317  
318 318  LX5V high-speed input counter will update the input frequency in the special soft element (SD) every 100us.
319 319  
320 -= **6 High-speed output function** =
315 += **7 High-speed output function** =
321 321  
322 322  **High-speed pulse commands are the same in the use of commands.**
323 323  
... ... @@ -464,7 +464,7 @@
464 464  
465 465  ⑨Support direction reversal (can set the forward direction to low level)
466 466  
467 -= **7 Communication function** =
462 += **8 Communication function** =
468 468  
469 469  **~1. Communication parameter configuration**
470 470  
企业微信截图_16762524911554.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Jim
Size
... ... @@ -1,1 +1,0 @@
1 -20.4 KB
Content