Changes for page 17 LX3V/5V/5S comparsion
Last modified by Jim on 2025/02/11 11:34
From version 31.1
edited by Karen
on 2023/05/30 11:47
on 2023/05/30 11:47
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - 17LX3V/5V/5S comparsion1 +03 LX3V/5V/5S comparion - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PLC Editor2.WebHome 1 +PLC Editor2.1 User manual.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Karen1 +XWiki.Stone - Content
-
... ... @@ -1,4 +1,4 @@ 1 -= **1 Basic difference s** =1 += **1 Basic difference between 3V, 5V and 5S** = 2 2 3 3 |=(% scope="row" %)Functions|=5V|=5S|=3V 4 4 |=Running Mode|(% colspan="3" %)Cyclic scan /Interrupt ... ... @@ -8,6 +8,7 @@ 8 8 1616;2416;2424;3624;|0806;1208;1212;1412; 9 9 1616;2416;2424;3624; 10 10 |=Programming|(% colspan="3" %)Ladder 11 +|=Type of instruction| | | 11 11 |=Execute Time|Basic 0.01-0.03μs|Basic 0.03-0.08μs|Basic 0.06μs/Applied instruction:1-10us 12 12 |=Program Capacity|(% colspan="2" %)512KB|16k 13 13 |=High Speed Pulse Output|≤1412MT and smaller: 4*200KHz; ... ... @@ -18,22 +18,10 @@ 18 18 |=X Interrupt|X0-X7 Rising & Falling|X0-X5 Rising & Falling|X0-X5 Rising & Falling 19 19 |=**High speed counter Single Phase**|**≤1412 and smaller: 4*150KHz 20 20 ≥1616 and bigger: 8*150KHz**|**≤1412 and smaller: 2*150KHz;4*10KHz 21 -≥1616 and bigger: 6*150KHz**|((( 22 -**Hardware counter for the first two channels:2*200KHz;** 23 - 24 -**Software counter for the first two channels:2*100KHz;** 25 - 26 -**Software counter for back four channels:4*10KHz** 27 -))) 22 +≥1616 and bigger: 6*150KHz**|**2*200KHz; 4*10KHz** 28 28 |=**High speed counter AB phase**|**≤1412 and smaller: 4*100KHz 29 29 ≥1616 and bigger: 8*100KHz**|**≤1412 and smaller: 1*100KHz+2*10KHz 30 -≥1616 and bigger: 3*100KHz**|((( 31 -**Hardware counter for the first two channels:2*100KHz;** 32 - 33 -**Software counter for the first two channels:2*50KHz;** 34 - 35 -**Software counter for back four channels:4*5KHz** 36 -))) 25 +≥1616 and bigger: 3*100KHz**|**2*100KHz** 37 37 |=Storage Type|(% colspan="3" %)FLASH 38 38 |=Serial Communication|((( 39 39 COM1: RS422、RS485;COM2: RS485 ... ... @@ -41,16 +41,16 @@ 41 41 1212 and bigger: COM1: RS422、RS485;COM2:RS485|1208 and smaller: COM1: RS422;COM2: RS485; 42 42 1212 and bigger: COM1: RS422、RS485;COM2: RS485 43 43 |=BD board support|yes|yes|yes 44 -|=Communication BD board|(% colspan="2" %) supportLX5V-2RS485-BD andLX5V-ETH-BD|RS485 BD support, 3vp supports ethernet bd board33 +|=Communication BD board|(% colspan="2" %)inbuilt ethernet port series, RS485 BD board in developing |RS485 BD support, 3vp supports ethernet bd board 45 45 |=Expansion Module|(% colspan="2" %)yes √ (1212 and bigger can support)|yes √ (1212 and bigger can support) 46 46 |=Electronic CAM|√(2 sheets for switch)|√(2 sheets for switch)|N/A 47 47 |=S-type CAM|√|√|N/A 48 -|= PLClink|√|√|N/A37 +|=N:N Comm|√|√|N/A 49 49 |=Linear Interpolation|√|√|N/A 50 50 |=Circular Interpolation|√|√|N/A 51 51 |=sub-rotine|√|√|N/A 52 52 53 -= **2 Software difference between 5S vs5V** =42 += **2 Software interface difference between 5S and 5V** = 54 54 55 55 == **High speed counter configuration** == 56 56 ... ... @@ -60,24 +60,24 @@ 60 60 61 61 **5S is as below** 62 62 63 -[[image: 企业微信截图_16762524911554.png]]52 +[[image:image-20220614151015-2.png]] 64 64 65 65 **More detail information,please check the product catalog** 66 66 67 67 = **3** **Functions that 3V has but 5V does not** = 68 68 69 -== **BD module** ==58 +== **BD board** == 70 70 71 -LX5V does not support LX3V-2RS485-BD60 +LX5V does not support RS485 BD 72 72 73 -LX5V does not support LX3V-ETH-BD62 +LX5V does not support Ethernet BD 74 74 75 - ==**Analog BD moduleexpansionaddress**==64 +LX5V does not support CAN BD 76 76 77 -Provides the function of analog module BD to modify parameters such as filtering. For specific functions, please refer to the below link: 78 -~1. LX3 series: [[5-9 System-special address - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor/05%20Registers/5-9%20system-special%20address/#HCOM1communicationsettings26BDmoduleconfiguration]] 79 -2. LX5 series: [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule]] [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule-1]] 66 +== **Analog BD board expansion address** == 80 80 68 +Provides the function of analog board BD to modify parameters such as filtering. For specific functions, please refer to the BD board manual. 69 + 81 81 == **PLDID** == 82 82 83 83 Program label function, when the label of the program corresponds to the label of the PLC, the ladder diagram can be uploaded and downloaded. Clearing the memory does not clear this tag either. It is mainly to limit the ladder diagram used by PLC. ... ... @@ -133,8 +133,14 @@ 133 133 |=M8174|X004 pulse capture 134 134 |=M8175|X005 pulse capture 135 135 136 -= **4 3V and5Vincompatiblefunctions** =125 += **4 5V function under development** = 137 137 127 +N:N communication protocol 128 + 129 +Interpolation instructions (G90G01, G90G02, G90G03, G91G01, G91G02, G91G03) 130 + 131 += **5 3V and 5V incompatible functions** = 132 + 138 138 (% class="wikigeneratedid" %) 139 139 **(These can be automatically converted in the future)** 140 140 ... ... @@ -279,7 +279,7 @@ 279 279 280 280 [[image:1652689626279-240.png]] 281 281 282 -= ** 5High-speed input function** =277 += **6 High-speed input function** = 283 283 284 284 == **Use on LX3V** == 285 285 ... ... @@ -317,7 +317,7 @@ 317 317 318 318 LX5V high-speed input counter will update the input frequency in the special soft element (SD) every 100us. 319 319 320 -= ** 6High-speed output function** =315 += **7 High-speed output function** = 321 321 322 322 **High-speed pulse commands are the same in the use of commands.** 323 323 ... ... @@ -464,7 +464,7 @@ 464 464 465 465 ⑨Support direction reversal (can set the forward direction to low level) 466 466 467 -= ** 7Communication function** =462 += **8 Communication function** = 468 468 469 469 **~1. Communication parameter configuration** 470 470
- 企业微信截图_16762524911554.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Jim - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.4 KB - Content