Changes for page 17 LX3V/5V/5S comparsion

Last modified by Jim on 2025/02/11 11:34

From version 32.1
edited by Mora Zhou
on 2023/09/08 17:38
Change comment: There is no comment for this version
To version 14.1
edited by Leo Wei
on 2022/06/14 15:36
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -17 LX3V/5V/5S comparsion
1 +03 Difference between 3V, 5V and 5S
Parent
... ... @@ -1,1 +1,1 @@
1 -PLC Editor2.WebHome
1 +PLC Editor2.1 User manual.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Mora
1 +XWiki.admin
Content
... ... @@ -1,4 +1,4 @@
1 -= **1 Basic differences** =
1 += **1 Basic difference between 3V, 5V and 5S** =
2 2  
3 3  |=(% scope="row" %)Functions|=5V|=5S|=3V
4 4  |=Running Mode|(% colspan="3" %)Cyclic scan /Interrupt
... ... @@ -8,6 +8,7 @@
8 8  1616;2416;2424;3624;|0806;1208;1212;1412;
9 9  1616;2416;2424;3624;
10 10  |=Programming|(% colspan="3" %)Ladder
11 +|=Type of instruction| | |
11 11  |=Execute Time|Basic 0.01-0.03μs|Basic 0.03-0.08μs|Basic 0.06μs/Applied instruction:1-10us
12 12  |=Program Capacity|(% colspan="2" %)512KB|16k
13 13  |=High Speed Pulse Output|≤1412MT and smaller: 4*200KHz;
... ... @@ -18,22 +18,10 @@
18 18  |=X Interrupt|X0-X7 Rising & Falling|X0-X5 Rising & Falling|X0-X5 Rising & Falling
19 19  |=**High speed counter Single Phase**|**≤1412 and smaller: 4*150KHz
20 20  ≥1616 and bigger: 8*150KHz**|**≤1412 and smaller: 2*150KHz;4*10KHz
21 -≥1616 and bigger: 6*150KHz**|(((
22 -**Hardware counter for the first two channels:2*200KHz;**
23 -
24 -**Software counter for the first two channels:2*100KHz;**
25 -
26 -**Software counter for back four channels:4*10KHz**
27 -)))
22 +≥1616 and bigger: 6*150KHz**|**2*200KHz; 4*10KHz**
28 28  |=**High speed counter AB phase**|**≤1412 and smaller: 4*100KHz
29 29  ≥1616 and bigger: 8*100KHz**|**≤1412 and smaller: 1*100KHz+2*10KHz
30 -≥1616 and bigger: 3*100KHz**|(((
31 -**Hardware counter for the first two channels:2*100KHz;**
32 -
33 -**Software counter for the first two channels:2*50KHz;**
34 -
35 -**Software counter for back four channels:4*5KHz**
36 -)))
25 +≥1616 and bigger: 3*100KHz**|**2*100KHz**
37 37  |=Storage Type|(% colspan="3" %)FLASH
38 38  |=Serial Communication|(((
39 39  COM1: RS422、RS485;COM2: RS485
... ... @@ -41,18 +41,18 @@
41 41  1212 and bigger: COM1: RS422、RS485;COM2:RS485|1208 and smaller: COM1: RS422;COM2: RS485;
42 42  1212 and bigger: COM1: RS422、RS485;COM2: RS485
43 43  |=BD board support|yes|yes|yes
44 -|=Communication BD board|(% colspan="2" %)support LX5V-2RS485-BD and LX5V-ETH-BD|RS485 BD support, 3vp supports ethernet bd board
33 +|=Communication BD board|(% colspan="2" %)inbuilt ethernet port series, RS485 BD board in developing |RS485 BD support, 3vp supports ethernet bd board
45 45  |=Expansion Module|(% colspan="2" %)yes √ (1212 and bigger can support)|yes √ (1212 and bigger can support)
46 46  |=Electronic CAM|√(2 sheets for switch)|√(2 sheets for switch)|N/A
47 47  |=S-type CAM|√|√|N/A
48 -|=PLClink|√|√|N/A
37 +|=N:N Comm|√|√|N/A
49 49  |=Linear Interpolation|√|√|N/A
50 50  |=Circular Interpolation|√|√|N/A
51 51  |=sub-rotine|√|√|N/A
52 52  
53 -= **2 Software difference between 5S vs 5V** =
42 += **2 Software interface difference between 5S and 5V** =
54 54  
55 -== **High speed counter configuration** ==
44 +== **2.1 High speed counter configuration** ==
56 56  
57 57  **5V as below**
58 58  
... ... @@ -60,29 +60,29 @@
60 60  
61 61  **5S is as below**
62 62  
63 -[[image:企业微信截图_16762524911554.png]]
52 +[[image:image-20220614151015-2.png]]
64 64  
65 65  **More detail information,please check the product catalog**
66 66  
67 67  = **3** **Functions that 3V has but 5V does not** =
68 68  
69 -== **BD module** ==
58 +== **3.1 BD board** ==
70 70  
71 -LX5V does not support LX3V-2RS485-BD
60 +LX5V does not support RS485 BD
72 72  
73 -LX5V does not support LX3V-ETH-BD
62 +LX5V does not support Ethernet BD
74 74  
75 -== **Analog BD module expansion address** ==
64 +LX5V does not support CAN BD
76 76  
77 -Provides the function of analog module BD to modify parameters such as filtering. For specific functions, please refer to the below link:
78 -~1. LX3 series: [[5-9 System-special address - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor/05%20Registers/5-9%20system-special%20address/#HCOM1communicationsettings26BDmoduleconfiguration]]
79 -2. LX5 series: [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule]] [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule-1]]
66 +== **3.2 Analog BD board expansion address** ==
80 80  
81 -== **PLDID** ==
68 +Provides the function of analog board BD to modify parameters such as filtering. For specific functions, please refer to the BD board manual.
82 82  
70 +== **3.3 PLDID** ==
71 +
83 83  Program label function, when the label of the program corresponds to the label of the PLC, the ladder diagram can be uploaded and downloaded. Clearing the memory does not clear this tag either. It is mainly to limit the ladder diagram used by PLC.
84 84  
85 -== **Instructions** ==
74 +== **3.4 Instructions** ==
86 86  
87 87  (1) NOP instruction (null instruction)
88 88  
... ... @@ -106,9 +106,9 @@
106 106  
107 107  (11) CPAVL instruction(communication BD configuration)
108 108  
109 -== **Unsupported special register function (M8000, D8000)** ==
98 +== **3.5 Unsupported special register function (M8000, D8000)** ==
110 110  
111 -=== **Clock related** ===
100 +=== **3.5.1 Clock related** ===
112 112  
113 113  Clock function not supported by LX5V
114 114  
... ... @@ -119,12 +119,12 @@
119 119  |=M8018|install and examine
120 120  |=M8019|Real-time clock (RTC) error
121 121  
122 -=== **High-speed counter ring counting function** ===
111 +=== **3.5.2 High-speed counter ring counting function** ===
123 123  
124 124  |=M8099|High-speed ring counter count start
125 125  |=M8099|Ring count configuration
126 126  
127 -=== **X0~~X5 pulse capture function** ===
116 +=== **3.5.3 X0~~X5 pulse capture function** ===
128 128  
129 129  |=M8170|X000 pulse capture
130 130  |=M8171|X001 pulse capture
... ... @@ -133,13 +133,16 @@
133 133  |=M8174|X004 pulse capture
134 134  |=M8175|X005 pulse capture
135 135  
136 -= **4 3V and 5V incompatible functions** =
125 += **4. 5V function under development** =
137 137  
138 -(% class="wikigeneratedid" %)
139 -**(These can be automatically converted in the future)**
127 +N:N communication protocol
140 140  
141 -== **General register** ==
129 +Interpolation instructions (G90G01, G90G02, G90G03, G91G01, G91G02, G91G03)
142 142  
131 += **5. 3V and 5V incompatible functions (These can be automatically converted in the future)** =
132 +
133 +== **5.1 General register** ==
134 +
143 143  (% class="table-bordered" %)
144 144  |=(% scope="row" %)**register**|=**LX3V**|=**LX5V**|=**Remarks**
145 145  |=Input|X0~~X377|X0~~X1777|
... ... @@ -168,13 +168,10 @@
168 168  
169 169  5. Pointer I is cancelled in LX5V, please check the programming mode for details.
170 170  
171 -== **Programming method** ==
163 +== **5.2 Programming method** ==
172 172  
173 -=== **Subroutine** ===
165 +=== **5.2.1 Subroutine (For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)** ===
174 174  
175 -(% class="wikigeneratedid" %)
176 -**(For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)**
177 -
178 178  **Use of LX3V subroutines**
179 179  [[image:1652684087594-147.png]]
180 180  
... ... @@ -188,11 +188,8 @@
188 188  
189 189  [[image:1652684829740-769.png]]
190 190  
191 -=== **Interrupt** ===
180 +=== **5.2.2 Interrupt (For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)** ===
192 192  
193 -(% class="wikigeneratedid" %)
194 -**(For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)**
195 -
196 196  **LX3V interrupt**
197 197  
198 198  The interrupt program is under FEND and returns with IRET. The meaning of the specific interrupt is distinguished by the pointer I number.(Refer to EI/DI instruction in 3V)
... ... @@ -211,9 +211,9 @@
211 211  
212 212  [[image:1652685809566-630.png]]
213 213  
214 -=== **Instructions** ===
200 +=== **5.2.3 Instructions** ===
215 215  
216 -**OUT instruction**
202 +**OUT command**
217 217  
218 218  Double word counter[[image:file:///C:\Users\ANNAXU~~1\AppData\Local\Temp\ksohtml14432\wps28.png]]
219 219  
... ... @@ -279,9 +279,9 @@
279 279  
280 280  [[image:1652689626279-240.png]]
281 281  
282 -= **5 High-speed input function** =
268 += **6. High-speed input function** =
283 283  
284 -== **Use on LX3V** ==
270 +== **6.1 Use on LX3V** ==
285 285  
286 286  Find the high-speed input counter you need to use according to the following table:
287 287  
... ... @@ -293,7 +293,7 @@
293 293  
294 294  [[image:1652690126303-800.png]]
295 295  
296 -== **Use on LX5V** ==
282 +== **6.2 Use on LX5V** ==
297 297  
298 298  According to channel, select the HSC register to use:
299 299  
... ... @@ -307,10 +307,11 @@
307 307  
308 308  [[image:1652692388207-617.png]]
309 309  
310 -== **Difference between high-speed counters on LX5V and LX3V** ==
296 +== **6.3 Difference between high-speed counters on LX5V and LX3V** ==
311 311  
312 312  LX3V updates the count value when the OUT instruction is executed, which is affected by the scan cycle.
313 313  
300 +
314 314  LX5V is updated in the 100us interrupt, not affected by the scan cycle, and provides the REF instruction to refresh the current high-speed counter value immediately.
315 315  
316 316  LX5V single-phase high-speed counter supports filtering function, configurable 0~~17us.
... ... @@ -317,7 +317,7 @@
317 317  
318 318  LX5V high-speed input counter will update the input frequency in the special soft element (SD) every 100us.
319 319  
320 -= **6 High-speed output function** =
307 += **7. High-speed output function** =
321 321  
322 322  **High-speed pulse commands are the same in the use of commands.**
323 323  
... ... @@ -345,13 +345,13 @@
345 345  (% class="table-bordered" %)
346 346  |=(% scope="row" %)**3V**|=**Description**|=**5V**|=**Description**
347 347  |=M8145|Y000 pulse output stop|SM898|Y000 pulse output stop
348 -|=M8146|Y001 pulse output stop|SM958|Y001 Pulse output stop
335 +|=M8146|Y001 Pulse output stop|SM958|Y001 Pulse output stop
349 349  |=M8152|Y002 pulse output stop|SM1018|Y002 pulse output stop
350 -|=M8153|Y003 pulse output stop|SM1078|Y003 Pulse output stop
337 +|=M8153|Y003 Pulse output stop|SM1078|Y003 Pulse output stop
351 351  |=M8147|Y000 monitoring during pulse output|SM880|Y000 monitoring during pulse output
352 -|=M8148|Y001 monitoring during pulse output|SM940|Y001 Monitoring during pulse output
353 -|=M8149|Y002 monitoring during pulse output|SM1000|Y002 Monitoring during pulse output
354 -|=M8150|Y003 monitoring during pulse output|SM1060|Y003 Monitoring during pulse output
339 +|=M8148|Y001 Monitoring during pulse output|SM940|Y001 Monitoring during pulse output
340 +|=M8149|Y002 Monitoring during pulse output|SM1000|Y002 Monitoring during pulse output
341 +|=M8150|Y003 Monitoring during pulse output|SM1060|Y003 Monitoring during pulse output
355 355  |=(% rowspan="4" %)(((
356 356  
357 357  
... ... @@ -371,8 +371,8 @@
371 371  )))|(((
372 372  SM957
373 373  )))|Y1 Perimeter control bit
374 -|=M8136|Y2 perimeter control bit|SM1017|Y2 Perimeter control bit
375 -|=M8137|Y3 perimeter control bit|SM1077|Y3 Perimeter control bit
361 +|=M8136|Y2 Perimeter control bit|SM1017|Y2 Perimeter control bit
362 +|=M8137|Y3 Perimeter control bit|SM1077|Y3 Perimeter control bit
376 376  
377 377  3. Comparison of word devices
378 378  
... ... @@ -382,14 +382,14 @@
382 382  |=D8105|Y1 acceleration and deceleration time (open M8135)|SD1022/SD1082|Y1 acceleration/deceleration time
383 383  |=D8106|Y2 acceleration and deceleration time (open M8135)|SD1142/SD1202|Y2 acceleration/deceleration time
384 384  |=D8107|Y3 acceleration and deceleration time (open M8135)|SD1262/SD1322|Y3 acceleration/deceleration time
385 -|=D8140|Y000 current position low|SD880|Y000 Current position low
372 +|=D8140|Y000 Current position low|SD880|Y000 Current position low
386 386  |=D8141|Y000 current position high|SD881|Y000 current position high
387 -|=D8142|Y001 current position low|SD940|Y001 Current position low
388 -|=D8143|Y001 current position high|SD941|Y001 Current position high
374 +|=D8142|Y001 Current position low|SD940|Y001 Current position low
375 +|=D8143|Y001 Current position high|SD941|Y001 Current position high
389 389  |=D8150|Y002 current position low|SD1000|Y002 current position low
390 390  |=D8151|Y002 current position high|SD1001|Y002 current position high
391 -|=D8152|Y003 current position low|SD1060|Y003 Current position low
392 -|=D8153|Y003 current position high|SD1061|Y003 Current position high
378 +|=D8152|Y003 Current position low|SD1060|Y003 Current position low
379 +|=D8153|Y003 Current position high|SD1061|Y003 Current position high
393 393  |=(% rowspan="4" %)(((
394 394  
395 395  
... ... @@ -399,7 +399,7 @@
399 399  
400 400  
401 401  
402 -Y0-Y3 paranoid speed (single word)
389 +Y0-Y3 Paranoid speed (single word)
403 403  )))|SD900, SD901|Y0 Paranoid speed (double word)
404 404  |=SD960, SD961|Y1 Paranoid speed (double word)
405 405  |=SD1020, SD1021|Y2 Paranoid speed (double word)
... ... @@ -464,7 +464,7 @@
464 464  
465 465  ⑨Support direction reversal (can set the forward direction to low level)
466 466  
467 -= **7 Communication function** =
454 += **8. Communication function** =
468 468  
469 469  **~1. Communication parameter configuration**
470 470  
... ... @@ -540,3 +540,6 @@
540 540  **5. LX5V added functions**
541 541  
542 542  Modify serial communication parameters during RUN. For example, use PROTOCOL instruction to modify the protocol during run. The corresponding instruction description can also find the method of setting without instruction. For details, please refer to the relevant instructions of the instruction. Commands are PROTOCOL (set serial port protocol), PROTPARA (set serial port parameters), STATION (set station number)
530 +
531 +
532 +
企业微信截图_16762524911554.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Jim
Size
... ... @@ -1,1 +1,0 @@
1 -20.4 KB
Content