Changes for page 17 LX3V/5V/5S comparsion

Last modified by Jim on 2025/02/11 11:34

From version 32.1
edited by Mora Zhou
on 2023/09/08 17:38
Change comment: There is no comment for this version
To version 2.1
edited by Jim
on 2022/06/14 14:48
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -17 LX3V/5V/5S comparsion
1 +Difference between 3V, 5V and 5S
Parent
... ... @@ -1,1 +1,1 @@
1 -PLC Editor2.WebHome
1 +PLC Editor2.1 User manual.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Mora
1 +XWiki.Jim
Content
... ... @@ -1,88 +1,22 @@
1 -= **1 Basic differences** =
1 += **1.** **Functions that 3V has but 5V does not** =
2 2  
3 -|=(% scope="row" %)Functions|=5V|=5S|=3V
4 -|=Running Mode|(% colspan="3" %)Cyclic scan /Interrupt
5 -|=Power supply|(% colspan="3" %)A:AC 220V;D:DC 24V
6 -|=Output type|MT:Transistor|MT:Transistor;MR:Relay|MT:Transistor;MR:Relay
7 -|=I/O|1212;1412;1616;2416;2424;3624;|0806;1208;1212;1412;
8 -1616;2416;2424;3624;|0806;1208;1212;1412;
9 -1616;2416;2424;3624;
10 -|=Programming|(% colspan="3" %)Ladder
11 -|=Execute Time|Basic 0.01-0.03μs|Basic 0.03-0.08μs|Basic 0.06μs/Applied instruction:1-10us
12 -|=Program Capacity|(% colspan="2" %)512KB|16k
13 -|=High Speed Pulse Output|≤1412MT and smaller: 4*200KHz;
14 -≥1616MT and bigger:  8*200KHz。|MT/MR2H: 2* 200KHz;
15 -MT4H: 4* 200KHz。|MT/2H: 2*100KHZ, or 4H: 4*100, single: 200kHZ
16 -|=High speed counter Interrupt|(% colspan="2" %)100 channels|21channels
17 -|=Timer Interrupt|(% colspan="2" %)100 channels,Support 0.1ms Interrupt|95 channels
18 -|=X Interrupt|X0-X7 Rising & Falling|X0-X5 Rising & Falling|X0-X5 Rising & Falling
19 -|=**High speed counter Single Phase**|**≤1412 and smaller: 4*150KHz
20 -≥1616 and bigger: 8*150KHz**|**≤1412 and smaller: 2*150KHz;4*10KHz
21 -≥1616 and bigger: 6*150KHz**|(((
22 -**Hardware counter for the first two channels:2*200KHz;**
3 +== **1.1 BD board** ==
23 23  
24 -**Software counter for the first two channels:2*100KHz;**
5 +LX5V does not support RS485 BD
25 25  
26 -**Software counter for back four channels:4*10KHz**
27 -)))
28 -|=**High speed counter AB phase**|**≤1412 and smaller: 4*100KHz
29 -≥1616 and bigger: 8*100KHz**|**≤1412 and smaller: 1*100KHz+2*10KHz
30 -≥1616 and bigger: 3*100KHz**|(((
31 -**Hardware counter for the first two channels:2*100KHz;**
7 +LX5V does not support Ethernet BD
32 32  
33 -**Software counter for the first two channels:2*50KHz;**
9 +LX5V does not support CAN BD
34 34  
35 -**Software counter for back four channels:4*5KHz**
36 -)))
37 -|=Storage Type|(% colspan="3" %)FLASH
38 -|=Serial Communication|(((
39 -COM1: RS422、RS485;COM2: RS485
40 -)))|1208 and smaller: COM1: RS422;COM2: RS485;
41 -1212 and bigger: COM1: RS422、RS485;COM2:RS485|1208 and smaller: COM1: RS422;COM2: RS485;
42 -1212 and bigger: COM1: RS422、RS485;COM2: RS485
43 -|=BD board support|yes|yes|yes
44 -|=Communication BD board|(% colspan="2" %)support LX5V-2RS485-BD and LX5V-ETH-BD|RS485 BD support, 3vp supports ethernet bd board
45 -|=Expansion Module|(% colspan="2" %)yes √ (1212 and bigger can support)|yes √ (1212 and bigger can support)
46 -|=Electronic CAM|√(2 sheets for switch)|√(2 sheets for switch)|N/A
47 -|=S-type CAM|√|√|N/A
48 -|=PLClink|√|√|N/A
49 -|=Linear Interpolation|√|√|N/A
50 -|=Circular Interpolation|√|√|N/A
51 -|=sub-rotine|√|√|N/A
11 +== **1.2 Analog BD board expansion address** ==
52 52  
53 -= **2 Software difference between 5S vs 5V** =
13 +Provides the function of analog board BD to modify parameters such as filtering. For specific functions, please refer to the BD board manual.
54 54  
55 -== **High speed counter configuration** ==
15 +== **1.3 PLDID** ==
56 56  
57 -**5V as below**
58 -
59 -[[image:image-20220614151005-1.png]]
60 -
61 -**5S is as below**
62 -
63 -[[image:企业微信截图_16762524911554.png]]
64 -
65 -**More detail information,please check the product catalog**
66 -
67 -= **3** **Functions that 3V has but 5V does not** =
68 -
69 -== **BD module** ==
70 -
71 -LX5V does not support LX3V-2RS485-BD
72 -
73 -LX5V does not support LX3V-ETH-BD
74 -
75 -== **Analog BD module expansion address** ==
76 -
77 -Provides the function of analog module BD to modify parameters such as filtering. For specific functions, please refer to the below link:
78 -~1. LX3 series: [[5-9 System-special address - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor/05%20Registers/5-9%20system-special%20address/#HCOM1communicationsettings26BDmoduleconfiguration]]
79 -2. LX5 series: [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule]] [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule-1]]
80 -
81 -== **PLDID** ==
82 -
83 83  Program label function, when the label of the program corresponds to the label of the PLC, the ladder diagram can be uploaded and downloaded. Clearing the memory does not clear this tag either. It is mainly to limit the ladder diagram used by PLC.
84 84  
85 -== **Instructions** ==
19 +== **1.4 Instructions** ==
86 86  
87 87  (1) NOP instruction (null instruction)
88 88  
... ... @@ -106,55 +106,61 @@
106 106  
107 107  (11) CPAVL instruction(communication BD configuration)
108 108  
109 -== **Unsupported special register function (M8000, D8000)** ==
43 +== **1.5 Unsupported special register function (M8000, D8000)** ==
110 110  
111 -=== **Clock related** ===
45 +=== **1.5.1 Clock related** ===
112 112  
113 113  Clock function not supported by LX5V
114 114  
115 -|=M8014|Oscillation clock with 1 minute clock period
116 -|=M8015|Clock stop and preset
117 -|=M8016|Stop time to read the display
118 -|=M8017|±30 seconds correction
119 -|=M8018|install and examine
120 -|=M8019|Real-time clock (RTC) error
49 +(% class="table-bordered" %)
50 +|M8014|Oscillation clock with 1 minute clock period
51 +|M8015|Clock stop and preset
52 +|M8016|Stop time to read the display
53 +|M8017|±30 seconds correction
54 +|M8018|install and examine
55 +|M8019|Real-time clock (RTC) error
121 121  
122 -=== **High-speed counter ring counting function** ===
57 +=== **1.5.2 High-speed counter ring counting function** ===
123 123  
124 -|=M8099|High-speed ring counter count start
125 -|=M8099|Ring count configuration
59 +(% class="table-bordered" %)
60 +|M8099|High-speed ring counter count start
61 +|M8099|Ring count configuration
126 126  
127 -=== **X0~~X5 pulse capture function** ===
63 +=== **1.5.3 X0~~X5 pulse capture function** ===
128 128  
129 -|=M8170|X000 pulse capture
130 -|=M8171|X001 pulse capture
131 -|=M8172|X002 pulse capture
132 -|=M8173|X003 pulse capture
133 -|=M8174|X004 pulse capture
134 -|=M8175|X005 pulse capture
65 +(% class="table-bordered" %)
66 +|M8170|X000 pulse capture
67 +|M8171|X001 pulse capture
68 +|M8172|X002 pulse capture
69 +|M8173|X003 pulse capture
70 +|M8174|X004 pulse capture
71 +|M8175|X005 pulse capture
135 135  
136 -= **4 3V and 5V incompatible functions** =
73 += **2. 5V function under development** =
137 137  
138 -(% class="wikigeneratedid" %)
139 -**(These can be automatically converted in the future)**
75 +N:N communication protocol
140 140  
141 -== **General register** ==
77 +Interpolation instructions (G90G01, G90G02, G90G03, G91G01, G91G02, G91G03)
142 142  
79 += **3. 3V and 5V incompatible functions (These can be automatically converted in the future)** =
80 +
81 +== **3.1 General register** ==
82 +
143 143  (% class="table-bordered" %)
144 -|=(% scope="row" %)**register**|=**LX3V**|=**LX5V**|=**Remarks**
145 -|=Input|X0~~X377|X0~~X1777|
146 -|=Output|Y0~~Y377|Y0~~Y1777|
147 -|=Auxiliary|M0~~M3071|M0~~M7999|
148 -|=Status|S0~~S999|S0~~S4095|
149 -|=Timer|T0~~T255|T0~~T511|
150 -|=counter|C0~~C199|C0~~C255|
151 -|=Double word counter|C200~~C219|LC0~~LC99|Non-power-down save
152 -|=Double word counter|C220~~C234|LC100~~LC255|Power-down save
153 -|=High-speed counter|C235~~C255|HSC0~~HSC7|Check the high-speed input function
154 -|=Data Register|D0~~D7999|D0~~D7999 (R0~~R29999)|
155 -|=Pointer P|P0~~P127|P0~~P4095|
156 -|=Instruction I|I0~~I8xx|None|
157 -|=constant|K, H, E|K, H, E|
84 +|**register**|**LX3V**|**LX5V**|**Remarks**
85 +|Input|X0~~X377|X0~~X1777|
86 +|Output|Y0~~Y377|Y0~~Y1777|
87 +|Auxiliary|M0~~M3071|M0~~M7999|
88 +|Status|S0~~S999|S0~~S4095|
89 +|Timer|T0~~T255|T0~~T511|
90 +|counter|C0~~C199|C0~~C255|
91 +|Double word counter|C200~~C219|LC0~~LC99|Non-power-down save
92 +|Double word counter|C220~~C234|LC100~~LC255|Power-down save
93 +|High-speed counter|C235~~C255|HSC0~~HSC7|Check the high-speed input function
94 +|Data Register|D0~~D7999|D0~~D7999 (R0~~R29999)|
95 +|Pointer P|P0~~P127|P0~~P4095|
96 +|Instruction I|I0~~I8xx|None|
97 +|constant|K, H, E|K, H, E|
158 158  
159 159  **Incompatible part**
160 160  
... ... @@ -168,13 +168,10 @@
168 168  
169 169  5. Pointer I is cancelled in LX5V, please check the programming mode for details.
170 170  
171 -== **Programming method** ==
111 +== **3.2 Programming method** ==
172 172  
173 -=== **Subroutine** ===
113 +=== **3.2.1 Subroutine (For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)** ===
174 174  
175 -(% class="wikigeneratedid" %)
176 -**(For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)**
177 -
178 178  **Use of LX3V subroutines**
179 179  [[image:1652684087594-147.png]]
180 180  
... ... @@ -188,11 +188,8 @@
188 188  
189 189  [[image:1652684829740-769.png]]
190 190  
191 -=== **Interrupt** ===
128 +=== **3.2.2 Interrupt (For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)** ===
192 192  
193 -(% class="wikigeneratedid" %)
194 -**(For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)**
195 -
196 196  **LX3V interrupt**
197 197  
198 198  The interrupt program is under FEND and returns with IRET. The meaning of the specific interrupt is distinguished by the pointer I number.(Refer to EI/DI instruction in 3V)
... ... @@ -211,9 +211,9 @@
211 211  
212 212  [[image:1652685809566-630.png]]
213 213  
214 -=== **Instructions** ===
148 +=== **3.2.3 Instructions** ===
215 215  
216 -**OUT instruction**
150 +**OUT command**
217 217  
218 218  Double word counter[[image:file:///C:\Users\ANNAXU~~1\AppData\Local\Temp\ksohtml14432\wps28.png]]
219 219  
... ... @@ -279,9 +279,9 @@
279 279  
280 280  [[image:1652689626279-240.png]]
281 281  
282 -= **5 High-speed input function** =
216 += **4. High-speed input function** =
283 283  
284 -== **Use on LX3V** ==
218 +== **4.1 Use on LX3V** ==
285 285  
286 286  Find the high-speed input counter you need to use according to the following table:
287 287  
... ... @@ -293,7 +293,7 @@
293 293  
294 294  [[image:1652690126303-800.png]]
295 295  
296 -== **Use on LX5V** ==
230 +== **4.2 Use on LX5V** ==
297 297  
298 298  According to channel, select the HSC register to use:
299 299  
... ... @@ -307,10 +307,11 @@
307 307  
308 308  [[image:1652692388207-617.png]]
309 309  
310 -== **Difference between high-speed counters on LX5V and LX3V** ==
244 +== **4.3 Difference between high-speed counters on LX5V and LX3V** ==
311 311  
312 312  LX3V updates the count value when the OUT instruction is executed, which is affected by the scan cycle.
313 313  
248 +
314 314  LX5V is updated in the 100us interrupt, not affected by the scan cycle, and provides the REF instruction to refresh the current high-speed counter value immediately.
315 315  
316 316  LX5V single-phase high-speed counter supports filtering function, configurable 0~~17us.
... ... @@ -317,20 +317,20 @@
317 317  
318 318  LX5V high-speed input counter will update the input frequency in the special soft element (SD) every 100us.
319 319  
320 -= **6 High-speed output function** =
255 += **5. High-speed output function** =
321 321  
322 322  **High-speed pulse commands are the same in the use of commands.**
323 323  
324 324  (% class="table-bordered" %)
325 -|=(% scope="row" %) |=LX3V|=LX5V
326 -|=DRVI|√|√
327 -|=DRVA|√|√
328 -|=PLSR|√|√
329 -|=PLSV|√|√
330 -|=PLSY|√|√
331 -|=DVIT|√|√
332 -|=ZRN|√|√
333 -|=PLSR2|√|√
260 +| |LX3V|LX5V
261 +|DRVI|√|√
262 +|DRVA|√|√
263 +|PLSR|√|√
264 +|PLSV|√|√
265 +|PLSY|√|√
266 +|DVIT|√|√
267 +|ZRN|√|√
268 +|PLSR2|√|√
334 334  
335 335  **High-speed pulse command difference.**
336 336  
... ... @@ -343,16 +343,16 @@
343 343  2. Comparison of bit devices
344 344  
345 345  (% class="table-bordered" %)
346 -|=(% scope="row" %)**3V**|=**Description**|=**5V**|=**Description**
347 -|=M8145|Y000 pulse output stop|SM898|Y000 pulse output stop
348 -|=M8146|Y001 pulse output stop|SM958|Y001 Pulse output stop
349 -|=M8152|Y002 pulse output stop|SM1018|Y002 pulse output stop
350 -|=M8153|Y003 pulse output stop|SM1078|Y003 Pulse output stop
351 -|=M8147|Y000 monitoring during pulse output|SM880|Y000 monitoring during pulse output
352 -|=M8148|Y001 monitoring during pulse output|SM940|Y001 Monitoring during pulse output
353 -|=M8149|Y002 monitoring during pulse output|SM1000|Y002 Monitoring during pulse output
354 -|=M8150|Y003 monitoring during pulse output|SM1060|Y003 Monitoring during pulse output
355 -|=(% rowspan="4" %)(((
281 +|**3V**|**Description**|**5V**|**Description**
282 +|M8145|Y000 pulse output stop|SM898|Y000 pulse output stop
283 +|M8146|Y001 Pulse output stop|SM958|Y001 Pulse output stop
284 +|M8152|Y002 pulse output stop|SM1018|Y002 pulse output stop
285 +|M8153|Y003 Pulse output stop|SM1078|Y003 Pulse output stop
286 +|M8147|Y000 monitoring during pulse output|SM880|Y000 monitoring during pulse output
287 +|M8148|Y001 Monitoring during pulse output|SM940|Y001 Monitoring during pulse output
288 +|M8149|Y002 Monitoring during pulse output|SM1000|Y002 Monitoring during pulse output
289 +|M8150|Y003 Monitoring during pulse output|SM1060|Y003 Monitoring during pulse output
290 +|(% rowspan="4" %)(((
356 356  
357 357  
358 358  
... ... @@ -362,35 +362,35 @@
362 362  
363 363  Some instructions (PLSR, etc.) instruction execution completed (Y0-Y3)
364 364  )))|SM882|Y0 pulse sending completed
365 -|=SM942|Y1 pulse sending completed
366 -|=SM1002|Y2 pulse transmission completed
367 -|=SM1062|Y3 pulse transmission completed
368 -|=M8134|Y0's thousandth control bit|SM897|Y0's thousandth control bit
369 -|=M8135|(((
300 +|SM942|Y1 pulse sending completed
301 +|SM1002|Y2 pulse transmission completed
302 +|SM1062|Y3 pulse transmission completed
303 +|M8134|Y0's thousandth control bit|SM897|Y0's thousandth control bit
304 +|M8135|(((
370 370  The acceleration and deceleration time between each axis of Y1's thousandth control position positioning command is separated
371 371  )))|(((
372 372  SM957
373 373  )))|Y1 Perimeter control bit
374 -|=M8136|Y2 perimeter control bit|SM1017|Y2 Perimeter control bit
375 -|=M8137|Y3 perimeter control bit|SM1077|Y3 Perimeter control bit
309 +|M8136|Y2 Perimeter control bit|SM1017|Y2 Perimeter control bit
310 +|M8137|Y3 Perimeter control bit|SM1077|Y3 Perimeter control bit
376 376  
377 377  3. Comparison of word devices
378 378  
379 379  (% class="table-bordered" %)
380 -|=(% scope="row" %)**3V**|=**Description**|=**5V**|=**Description**
381 -|=D8104|Y0 acceleration and deceleration time (open M8135)|SD902/SD962|Y0 acceleration/deceleration time
382 -|=D8105|Y1 acceleration and deceleration time (open M8135)|SD1022/SD1082|Y1 acceleration/deceleration time
383 -|=D8106|Y2 acceleration and deceleration time (open M8135)|SD1142/SD1202|Y2 acceleration/deceleration time
384 -|=D8107|Y3 acceleration and deceleration time (open M8135)|SD1262/SD1322|Y3 acceleration/deceleration time
385 -|=D8140|Y000 current position low|SD880|Y000 Current position low
386 -|=D8141|Y000 current position high|SD881|Y000 current position high
387 -|=D8142|Y001 current position low|SD940|Y001 Current position low
388 -|=D8143|Y001 current position high|SD941|Y001 Current position high
389 -|=D8150|Y002 current position low|SD1000|Y002 current position low
390 -|=D8151|Y002 current position high|SD1001|Y002 current position high
391 -|=D8152|Y003 current position low|SD1060|Y003 Current position low
392 -|=D8153|Y003 current position high|SD1061|Y003 Current position high
393 -|=(% rowspan="4" %)(((
315 +|**3V**|**Description**|**5V**|**Description**
316 +|D8104|Y0 acceleration and deceleration time (open M8135)|SD902/SD962|Y0 acceleration/deceleration time
317 +|D8105|Y1 acceleration and deceleration time (open M8135)|SD1022/SD1082|Y1 acceleration/deceleration time
318 +|D8106|Y2 acceleration and deceleration time (open M8135)|SD1142/SD1202|Y2 acceleration/deceleration time
319 +|D8107|Y3 acceleration and deceleration time (open M8135)|SD1262/SD1322|Y3 acceleration/deceleration time
320 +|D8140|Y000 Current position low|SD880|Y000 Current position low
321 +|D8141|Y000 current position high|SD881|Y000 current position high
322 +|D8142|Y001 Current position low|SD940|Y001 Current position low
323 +|D8143|Y001 Current position high|SD941|Y001 Current position high
324 +|D8150|Y002 current position low|SD1000|Y002 current position low
325 +|D8151|Y002 current position high|SD1001|Y002 current position high
326 +|D8152|Y003 Current position low|SD1060|Y003 Current position low
327 +|D8153|Y003 Current position high|SD1061|Y003 Current position high
328 +|(% rowspan="4" %)(((
394 394  
395 395  
396 396  
... ... @@ -399,12 +399,12 @@
399 399  
400 400  
401 401  
402 -Y0-Y3 paranoid speed (single word)
337 +Y0-Y3 Paranoid speed (single word)
403 403  )))|SD900, SD901|Y0 Paranoid speed (double word)
404 -|=SD960, SD961|Y1 Paranoid speed (double word)
405 -|=SD1020, SD1021|Y2 Paranoid speed (double word)
406 -|=SD1080, SD1081|Y3 Paranoid speed (double word)
407 -|=(% rowspan="8" %)(((
339 +|SD960, SD961|Y1 Paranoid speed (double word)
340 +|SD1020, SD1021|Y2 Paranoid speed (double word)
341 +|SD1080, SD1081|Y3 Paranoid speed (double word)
342 +|(% rowspan="8" %)(((
408 408  
409 409  
410 410  
... ... @@ -419,14 +419,14 @@
419 419  
420 420  Y0-Y3 maximum frequency (double word)
421 421  )))|SD898|Y0 Maximum speed low
422 -|=SD899|Y0 Highest speed
423 -|=SD958|Y1 Maximum speed low
424 -|=SD959|Y1 Highest speed
425 -|=SD1018|Y2 Maximum speed low
426 -|=SD1019|Y2 Highest speed
427 -|=SD1078|Y3 Maximum speed low
428 -|=SD1079|Y3 Highest speed
429 -|=(% rowspan="4" %)(((
357 +|SD899|Y0 Highest speed
358 +|SD958|Y1 Maximum speed low
359 +|SD959|Y1 Highest speed
360 +|SD1018|Y2 Maximum speed low
361 +|SD1019|Y2 Highest speed
362 +|SD1078|Y3 Maximum speed low
363 +|SD1079|Y3 Highest speed
364 +|(% rowspan="4" %)(((
430 430  
431 431  
432 432  
... ... @@ -436,9 +436,9 @@
436 436  
437 437  4-axis acceleration/deceleration time (when M8135 is not turned on)
438 438  )))|SD902/SD962|Y0 acceleration/deceleration time
439 -|=SD1022/SD1082|Y1 acceleration/deceleration time
440 -|=SD1142/SD1202|Y2 acceleration/deceleration time
441 -|=SD1262/SD1322|Y3 acceleration/deceleration time
374 +|SD1022/SD1082|Y1 acceleration/deceleration time
375 +|SD1142/SD1202|Y2 acceleration/deceleration time
376 +|SD1262/SD1322|Y3 acceleration/deceleration time
442 442  
443 443   4. New features of high-speed pulse instructions on LX5V
444 444  
... ... @@ -464,7 +464,7 @@
464 464  
465 465  ⑨Support direction reversal (can set the forward direction to low level)
466 466  
467 -= **7 Communication function** =
402 += **6. Communication function** =
468 468  
469 469  **~1. Communication parameter configuration**
470 470  
... ... @@ -475,27 +475,27 @@
475 475  3V settings:
476 476  
477 477  (% class="table-bordered" %)
478 -|=(% scope="row" %)**protocol**|=**D8126 value setting**
479 -|=RS instruction (custom protocol)|00H
480 -|=HMI monitoring protocol (PLC protocol)|01H
481 -|=MODBUS-RTU slave|02H
482 -|=MODBUS-ASCII slave|03H
483 -|=N:N network communication protocol slave|04H
484 -|=RS instruction (custom protocol)|10H
485 -|=MODBUS-RTU master station|20H
486 -|=MODBUS-ASCII master station|30H
487 -|=N:N network communication protocol master station|40H
413 +|**protocol**|**D8126 value setting**
414 +|RS instruction (custom protocol)|00H
415 +|HMI monitoring protocol (PLC protocol)|01H
416 +|MODBUS-RTU slave|02H
417 +|MODBUS-ASCII slave|03H
418 +|N:N network communication protocol slave|04H
419 +|RS instruction (custom protocol)|10H
420 +|MODBUS-RTU master station|20H
421 +|MODBUS-ASCII master station|30H
422 +|N:N network communication protocol master station|40H
488 488  
489 489  5V settings:
490 490  
491 491  (% class="table-bordered" %)
492 -|=(% scope="row" %)**SD2592 value setting**|=**Protocol**
493 -|=0 H|Wecon Modbus slave
494 -|=2 H|ModbusRTU slave
495 -|=3 H|ModbusASCII slave
496 -|=10 H|User-defined protocol
497 -|=20 H|ModbusRTU master station
498 -|=30 H|(((
427 +|**SD2592 value setting**|**Protocol**
428 +|0 H|Wecon Modbus slave
429 +|2 H|ModbusRTU slave
430 +|3 H|ModbusASCII slave
431 +|10 H|User-defined protocol
432 +|20 H|ModbusRTU master station
433 +|30 H|(((
499 499  ModbusASCII master
500 500  
501 501  
... ... @@ -512,31 +512,34 @@
512 512  5V address:
513 513  
514 514  (% class="table-bordered" %)
515 -|=(% scope="row" %)Port|=Occupy|=(% style="width: 240px;" %)Address range|=(% style="width: 221px;" %)(((
450 +|Port|Occupy|(% style="width:240px" %)Address range|(% style="width:221px" %)(((
516 516  10 hex Register
517 -)))|=(((
452 +)))|(((
518 518  Total reserved land Address size
519 519  )))
520 -|=**Word address**| |(% style="width:240px" %) |(% style="width:221px" %) |
521 -|=T0~~T511|512 WORD|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %)0|1536
522 -|=C0~~C255|256 WORD|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024
523 -|=LC0~~LC255|512 WORD|(% style="width:240px" %)0x0A00-0x0BFF|(% style="width:221px" %)2560|1024
524 -|=HSC0~~HSC15|128 WORD|(% style="width:240px" %)0x0E00-0x0E1F|(% style="width:221px" %)3584|512
525 -|=D0~~D7999|8000 WORD|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384
526 -|=SD0~~SD4095|4096 WORD|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288
527 -|=R0~~R30000|30000 WORD|(% style="width:240px" %)0x8000-0xF52F|(% style="width:221px" %)32768|30000
528 -|=**Bit address**| |(% style="width:240px" %) |(% style="width:221px" %) |
529 -|=T0~~T511|512 bit|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %) |1536
530 -|=C0~~C255|256 bit|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024
531 -|=LC0~~LC255|256 bit|(% style="width:240px" %)0x0A00-0x0AFF|(% style="width:221px" %)2560|1024
532 -|=HSC0~~HSC15|64 bit|(% style="width:240px" %)0x0E00-0x0E0F|(% style="width:221px" %)3584|512
533 -|=M0~~M8000|8192bit|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384
534 -|=SM0~~SM4095|4096bit|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288
535 -|=Reserved| |(% style="width:240px" %)0x8000-0xBFFF|(% style="width:221px" %) |16383
536 -|=S0~~S4095|4096bit|(% style="width:240px" %)0xC000-0xCFFF|(% style="width:221px" %)49152|8192
537 -|=X0~~X1023|1024bit|(% style="width:240px" %)0xE000-0xE3FF|(% style="width:221px" %)57344|4096
538 -|=Y0~~Y1023|1024bit|(% style="width:240px" %)0xF000-0xF3FF|(% style="width:221px" %)61440|4096
455 +|**Word address**| |(% style="width:240px" %) |(% style="width:221px" %) |
456 +|T0~~T511|512 WORD|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %)0|1536
457 +|C0~~C255|256 WORD|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024
458 +|LC0~~LC255|512 WORD|(% style="width:240px" %)0x0A00-0x0BFF|(% style="width:221px" %)2560|1024
459 +|HSC0~~HSC15|128 WORD|(% style="width:240px" %)0x0E00-0x0E1F|(% style="width:221px" %)3584|512
460 +|D0~~D7999|8000 WORD|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384
461 +|SD0~~SD4095|4096 WORD|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288
462 +|R0~~R30000|30000 WORD|(% style="width:240px" %)0x8000-0xF52F|(% style="width:221px" %)32768|30000
463 +|**Bit address**| |(% style="width:240px" %) |(% style="width:221px" %) |
464 +|T0~~T511|512 bit|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %) |1536
465 +|C0~~C255|256 bit|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024
466 +|LC0~~LC255|256 bit|(% style="width:240px" %)0x0A00-0x0AFF|(% style="width:221px" %)2560|1024
467 +|HSC0~~HSC15|64 bit|(% style="width:240px" %)0x0E00-0x0E0F|(% style="width:221px" %)3584|512
468 +|M0~~M8000|8192bit|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384
469 +|SM0~~SM4095|4096bit|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288
470 +|Reserved| |(% style="width:240px" %)0x8000-0xBFFF|(% style="width:221px" %) |16383
471 +|S0~~S4095|4096bit|(% style="width:240px" %)0xC000-0xCFFF|(% style="width:221px" %)49152|8192
472 +|X0~~X1023|1024bit|(% style="width:240px" %)0xE000-0xE3FF|(% style="width:221px" %)57344|4096
473 +|Y0~~Y1023|1024bit|(% style="width:240px" %)0xF000-0xF3FF|(% style="width:221px" %)61440|4096
539 539  
540 540  **5. LX5V added functions**
541 541  
542 542  Modify serial communication parameters during RUN. For example, use PROTOCOL instruction to modify the protocol during run. The corresponding instruction description can also find the method of setting without instruction. For details, please refer to the relevant instructions of the instruction. Commands are PROTOCOL (set serial port protocol), PROTPARA (set serial port parameters), STATION (set station number)
478 +
479 +
480 +
image-20220614151005-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Jim
Size
... ... @@ -1,1 +1,0 @@
1 -25.3 KB
Content
image-20220614151015-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Jim
Size
... ... @@ -1,1 +1,0 @@
1 -25.3 KB
Content
企业微信截图_16762524911554.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Jim
Size
... ... @@ -1,1 +1,0 @@
1 -20.4 KB
Content