Changes for page 17 LX3V/5V/5S comparsion
Last modified by Jim on 2025/02/11 11:34
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - 03Difference between3V,5V and 5S1 +17 LX3V/5V/5S comparsion - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PLC Editor2. 1 User manual.WebHome1 +PLC Editor2.WebHome - Content
-
... ... @@ -1,48 +1,58 @@ 1 -= **1 Basic difference between 5S and 5V** =1 += **1 Basic differences** = 2 2 3 -|Functions|5V|5S|3V 4 -|Running Mode|(% colspan="3" %)Cyclic scan /Interrupt 5 -|Power supply|(% colspan="3" %)A:AC 220V;D:DC 24V 6 -|Output type|MT:Transistor|MT:Transistor;MR:Relay|MT:Transistor;MR:Relay 7 -|I/O|1212;1412;1616;2416;2424;3624;|0806;1208;1212;1412; 3 +|=(% scope="row" %)Functions|=5V|=5S|=3V 4 +|=Running Mode|(% colspan="3" %)Cyclic scan /Interrupt 5 +|=Power supply|(% colspan="3" %)A:AC 220V;D:DC 24V 6 +|=Output type|MT:Transistor|MT:Transistor;MR:Relay|MT:Transistor;MR:Relay 7 +|=I/O|1212;1412;1616;2416;2424;3624;|0806;1208;1212;1412; 8 8 1616;2416;2424;3624;|0806;1208;1212;1412; 9 9 1616;2416;2424;3624; 10 -|Programming|(% colspan="3" %)Ladder 11 -|Type of instruction| | | 12 -|Execute Time|Basic 0.01-0.03μs|Basic 0.03-0.08μs|Basic 0.06μs/Applied instruction:1-10us 13 -|Program Capacity|(% colspan="2" %)512KB|16k 14 -|High Speed Pulse Output|≤1412MT and smaller: 4*200KHz; 10 +|=Programming|(% colspan="3" %)Ladder 11 +|=Execute Time|Basic 0.01-0.03μs|Basic 0.03-0.08μs|Basic 0.06μs/Applied instruction:1-10us 12 +|=Program Capacity|(% colspan="2" %)512KB|16k 13 +|=High Speed Pulse Output|≤1412MT and smaller: 4*200KHz; 15 15 ≥1616MT and bigger: 8*200KHz。|MT/MR2H: 2* 200KHz; 16 16 MT4H: 4* 200KHz。|MT/2H: 2*100KHZ, or 4H: 4*100, single: 200kHZ 17 -|High speed counter Interrupt|(% colspan="2" %)100 channels|21channels 18 -|Timer Interrupt|(% colspan="2" %)100 channels,Support 0.1ms Interrupt|95 channels 19 -|X Interrupt|X0-X7 Rising & Falling|X0-X5 Rising & Falling|X0-X5 Rising & Falling 20 -|**High speed counter Single Phase**|**≤1412 and smaller: 4*150KHz 16 +|=High speed counter Interrupt|(% colspan="2" %)100 channels|21channels 17 +|=Timer Interrupt|(% colspan="2" %)100 channels,Support 0.1ms Interrupt|95 channels 18 +|=X Interrupt|X0-X7 Rising & Falling|X0-X5 Rising & Falling|X0-X5 Rising & Falling 19 +|=**High speed counter Single Phase**|**≤1412 and smaller: 4*150KHz 21 21 ≥1616 and bigger: 8*150KHz**|**≤1412 and smaller: 2*150KHz;4*10KHz 22 -≥1616 and bigger: 6*150KHz**|**2*200KHz; 4*10KHz** 23 -|**High speed counter AB phase**|**≤1412 and smaller: 4*100KHz 21 +≥1616 and bigger: 6*150KHz**|((( 22 +**Hardware counter for the first two channels:2*200KHz;** 23 + 24 +**Software counter for the first two channels:2*100KHz;** 25 + 26 +**Software counter for back four channels:4*10KHz** 27 +))) 28 +|=**High speed counter AB phase**|**≤1412 and smaller: 4*100KHz 24 24 ≥1616 and bigger: 8*100KHz**|**≤1412 and smaller: 1*100KHz+2*10KHz 25 -≥1616 and bigger: 3*100KHz**|**2*100KHz** 26 -|Storage Type|(% colspan="3" %)FLASH 27 -|Serial Communication|((( 30 +≥1616 and bigger: 3*100KHz**|((( 31 +**Hardware counter for the first two channels:2*100KHz;** 32 + 33 +**Software counter for the first two channels:2*50KHz;** 34 + 35 +**Software counter for back four channels:4*5KHz** 36 +))) 37 +|=Storage Type|(% colspan="3" %)FLASH 38 +|=Serial Communication|((( 28 28 COM1: RS422、RS485;COM2: RS485 29 29 )))|1208 and smaller: COM1: RS422;COM2: RS485; 30 30 1212 and bigger: COM1: RS422、RS485;COM2:RS485|1208 and smaller: COM1: RS422;COM2: RS485; 31 31 1212 and bigger: COM1: RS422、RS485;COM2: RS485 32 -|BD board support|yes|yes|yes 33 -|Communication BD board|(% colspan="2" %)inbuilt ethernet port series, RS485 BD board in developing |RS485 BD support, 3vp supports ethernet bd board 34 -|Expansion Module|(% colspan="2" %)yes √ (1212 and bigger can support)|yes √ (1212 and bigger can support) 35 -|Electronic CAM|√(2 sheets for switch)|√(2 sheets for switch)|N/A 36 -|S-type CAM|√|√|N/A 37 -|N:N Comm|√|√|N/A 38 -|Linear Interpolation|√|√|N/A 39 -|Circular Interpolation|√|√|N/A 40 -|sub-rotine|√|√|N/A 41 -| | | | 43 +|=BD board support|yes|yes|yes 44 +|=Communication BD board|(% colspan="2" %)support LX5V-2RS485-BD and LX5V-ETH-BD|RS485 BD support, 3vp supports ethernet bd board 45 +|=Expansion Module|(% colspan="2" %)yes √ (1212 and bigger can support)|yes √ (1212 and bigger can support) 46 +|=Electronic CAM|√(2 sheets for switch)|√(2 sheets for switch)|N/A 47 +|=S-type CAM|√|√|N/A 48 +|=PLClink|√|√|N/A 49 +|=Linear Interpolation|√|√|N/A 50 +|=Circular Interpolation|√|√|N/A 51 +|=sub-rotine|√|√|N/A 42 42 43 -= **2 Software interfacedifference between 5Sand5V** =53 += **2 Software difference between 5S vs 5V** = 44 44 45 -== ** 2.1High speed counter configuration** ==55 +== **High speed counter configuration** == 46 46 47 47 **5V as below** 48 48 ... ... @@ -50,29 +50,29 @@ 50 50 51 51 **5S is as below** 52 52 53 -[[image: image-20220614151015-2.png]]63 +[[image:企业微信截图_16762524911554.png]] 54 54 55 55 **More detail information,please check the product catalog** 56 56 57 57 = **3** **Functions that 3V has but 5V does not** = 58 58 59 -== ** 3.1BD board** ==69 +== **BD board** == 60 60 61 -LX5V does not support RS485 71 +LX5V does not support LX3V-2RS485-BD 62 62 63 -LX5V does not support E thernetBD73 +LX5V does not support LX3V-ETH-BD 64 64 65 - LX5VdoesnotsupportCAN BD75 +== **Analog BD board expansion address** == 66 66 67 -== **3.2 Analog BD board expansion address** == 77 +Provides the function of analog board BD to modify parameters such as filtering. For specific functions, please refer to the below link: 78 +~1. LX3 series: [[5-9 System-special address - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor/05%20Registers/5-9%20system-special%20address/#HCOM1communicationsettings26BDmoduleconfiguration]] 79 +2. LX5 series: [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule]] [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule-1]] 68 68 69 - Providesthe function of analog board BDto modify parameters such as filtering. For specific functions, please refer to the BDboard manual.81 +== **PLDID** == 70 70 71 -== **3.3 PLDID** == 72 - 73 73 Program label function, when the label of the program corresponds to the label of the PLC, the ladder diagram can be uploaded and downloaded. Clearing the memory does not clear this tag either. It is mainly to limit the ladder diagram used by PLC. 74 74 75 -== ** 3.4Instructions** ==85 +== **Instructions** == 76 76 77 77 (1) NOP instruction (null instruction) 78 78 ... ... @@ -96,61 +96,55 @@ 96 96 97 97 (11) CPAVL instruction(communication BD configuration) 98 98 99 -== ** 3.5Unsupported special register function (M8000, D8000)** ==109 +== **Unsupported special register function (M8000, D8000)** == 100 100 101 -=== ** 3.5.1Clock related** ===111 +=== **Clock related** === 102 102 103 103 Clock function not supported by LX5V 104 104 105 -(% class="table-bordered" %) 106 -|M8014|Oscillation clock with 1 minute clock period 107 -|M8015|Clock stop and preset 108 -|M8016|Stop time to read the display 109 -|M8017|±30 seconds correction 110 -|M8018|install and examine 111 -|M8019|Real-time clock (RTC) error 115 +|=M8014|Oscillation clock with 1 minute clock period 116 +|=M8015|Clock stop and preset 117 +|=M8016|Stop time to read the display 118 +|=M8017|±30 seconds correction 119 +|=M8018|install and examine 120 +|=M8019|Real-time clock (RTC) error 112 112 113 -=== ** 3.5.2High-speed counter ring counting function** ===122 +=== **High-speed counter ring counting function** === 114 114 115 -(% class="table-bordered" %) 116 -|M8099|High-speed ring counter count start 117 -|M8099|Ring count configuration 124 +|=M8099|High-speed ring counter count start 125 +|=M8099|Ring count configuration 118 118 119 -=== ** 3.5.3X0~~X5 pulse capture function** ===127 +=== **X0~~X5 pulse capture function** === 120 120 121 -(% class="table-bordered" %) 122 -|M8170|X000 pulse capture 123 -|M8171|X001 pulse capture 124 -|M8172|X002 pulse capture 125 -|M8173|X003 pulse capture 126 -|M8174|X004 pulse capture 127 -|M8175|X005 pulse capture 129 +|=M8170|X000 pulse capture 130 +|=M8171|X001 pulse capture 131 +|=M8172|X002 pulse capture 132 +|=M8173|X003 pulse capture 133 +|=M8174|X004 pulse capture 134 +|=M8175|X005 pulse capture 128 128 129 -= **4 .5Vfunctionunder development** =136 += **4 3V and 5V incompatible functions** = 130 130 131 -N:N communication protocol 138 +(% class="wikigeneratedid" %) 139 +**(These can be automatically converted in the future)** 132 132 133 - Interpolationinstructions(G90G01, G90G02, G90G03, G91G01, G91G02, G91G03)141 +== **General register** == 134 134 135 -= **5. 3V and 5V incompatible functions (These can be automatically converted in the future)** = 136 - 137 -== **5.1 General register** == 138 - 139 139 (% class="table-bordered" %) 140 -|**register**|**LX3V**|**LX5V**|**Remarks** 141 -|Input|X0~~X377|X0~~X1777| 142 -|Output|Y0~~Y377|Y0~~Y1777| 143 -|Auxiliary|M0~~M3071|M0~~M7999| 144 -|Status|S0~~S999|S0~~S4095| 145 -|Timer|T0~~T255|T0~~T511| 146 -|counter|C0~~C199|C0~~C255| 147 -|Double word counter|C200~~C219|LC0~~LC99|Non-power-down save 148 -|Double word counter|C220~~C234|LC100~~LC255|Power-down save 149 -|High-speed counter|C235~~C255|HSC0~~HSC7|Check the high-speed input function 150 -|Data Register|D0~~D7999|D0~~D7999 (R0~~R29999)| 151 -|Pointer P|P0~~P127|P0~~P4095| 152 -|Instruction I|I0~~I8xx|None| 153 -|constant|K, H, E|K, H, E| 144 +|=(% scope="row" %)**register**|=**LX3V**|=**LX5V**|=**Remarks** 145 +|=Input|X0~~X377|X0~~X1777| 146 +|=Output|Y0~~Y377|Y0~~Y1777| 147 +|=Auxiliary|M0~~M3071|M0~~M7999| 148 +|=Status|S0~~S999|S0~~S4095| 149 +|=Timer|T0~~T255|T0~~T511| 150 +|=counter|C0~~C199|C0~~C255| 151 +|=Double word counter|C200~~C219|LC0~~LC99|Non-power-down save 152 +|=Double word counter|C220~~C234|LC100~~LC255|Power-down save 153 +|=High-speed counter|C235~~C255|HSC0~~HSC7|Check the high-speed input function 154 +|=Data Register|D0~~D7999|D0~~D7999 (R0~~R29999)| 155 +|=Pointer P|P0~~P127|P0~~P4095| 156 +|=Instruction I|I0~~I8xx|None| 157 +|=constant|K, H, E|K, H, E| 154 154 155 155 **Incompatible part** 156 156 ... ... @@ -164,10 +164,13 @@ 164 164 165 165 5. Pointer I is cancelled in LX5V, please check the programming mode for details. 166 166 167 -== ** 5.2Programming method** ==171 +== **Programming method** == 168 168 169 -=== ** 5.2.1Subroutine(For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)** ===173 +=== **Subroutine** === 170 170 175 +(% class="wikigeneratedid" %) 176 +**(For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)** 177 + 171 171 **Use of LX3V subroutines** 172 172 [[image:1652684087594-147.png]] 173 173 ... ... @@ -181,8 +181,11 @@ 181 181 182 182 [[image:1652684829740-769.png]] 183 183 184 -=== ** 5.2.2Interrupt(For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)** ===191 +=== **Interrupt** === 185 185 193 +(% class="wikigeneratedid" %) 194 +**(For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)** 195 + 186 186 **LX3V interrupt** 187 187 188 188 The interrupt program is under FEND and returns with IRET. The meaning of the specific interrupt is distinguished by the pointer I number.(Refer to EI/DI instruction in 3V) ... ... @@ -201,9 +201,9 @@ 201 201 202 202 [[image:1652685809566-630.png]] 203 203 204 -=== ** 5.2.3Instructions** ===214 +=== **Instructions** === 205 205 206 -**OUT co mmand**216 +**OUT instruction** 207 207 208 208 Double word counter[[image:file:///C:\Users\ANNAXU~~1\AppData\Local\Temp\ksohtml14432\wps28.png]] 209 209 ... ... @@ -269,9 +269,9 @@ 269 269 270 270 [[image:1652689626279-240.png]] 271 271 272 -= ** 6.High-speed input function** =282 += **5 High-speed input function** = 273 273 274 -== ** 6.1Use on LX3V** ==284 +== **Use on LX3V** == 275 275 276 276 Find the high-speed input counter you need to use according to the following table: 277 277 ... ... @@ -283,7 +283,7 @@ 283 283 284 284 [[image:1652690126303-800.png]] 285 285 286 -== ** 6.2Use on LX5V** ==296 +== **Use on LX5V** == 287 287 288 288 According to channel, select the HSC register to use: 289 289 ... ... @@ -297,11 +297,10 @@ 297 297 298 298 [[image:1652692388207-617.png]] 299 299 300 -== ** 6.3Difference between high-speed counters on LX5V and LX3V** ==310 +== **Difference between high-speed counters on LX5V and LX3V** == 301 301 302 302 LX3V updates the count value when the OUT instruction is executed, which is affected by the scan cycle. 303 303 304 - 305 305 LX5V is updated in the 100us interrupt, not affected by the scan cycle, and provides the REF instruction to refresh the current high-speed counter value immediately. 306 306 307 307 LX5V single-phase high-speed counter supports filtering function, configurable 0~~17us. ... ... @@ -308,20 +308,20 @@ 308 308 309 309 LX5V high-speed input counter will update the input frequency in the special soft element (SD) every 100us. 310 310 311 -= ** 7.High-speed output function** =320 += **6 High-speed output function** = 312 312 313 313 **High-speed pulse commands are the same in the use of commands.** 314 314 315 315 (% class="table-bordered" %) 316 -| |LX3V|LX5V 317 -|DRVI|√|√ 318 -|DRVA|√|√ 319 -|PLSR|√|√ 320 -|PLSV|√|√ 321 -|PLSY|√|√ 322 -|DVIT|√|√ 323 -|ZRN|√|√ 324 -|PLSR2|√|√ 325 +|=(% scope="row" %) |=LX3V|=LX5V 326 +|=DRVI|√|√ 327 +|=DRVA|√|√ 328 +|=PLSR|√|√ 329 +|=PLSV|√|√ 330 +|=PLSY|√|√ 331 +|=DVIT|√|√ 332 +|=ZRN|√|√ 333 +|=PLSR2|√|√ 325 325 326 326 **High-speed pulse command difference.** 327 327 ... ... @@ -334,16 +334,16 @@ 334 334 2. Comparison of bit devices 335 335 336 336 (% class="table-bordered" %) 337 -|**3V**|**Description**|**5V**|**Description** 338 -|M8145|Y000 pulse output stop|SM898|Y000 pulse output stop 339 -|M8146|Y001 Pulse output stop|SM958|Y001 Pulse output stop 340 -|M8152|Y002 pulse output stop|SM1018|Y002 pulse output stop 341 -|M8153|Y003 Pulse output stop|SM1078|Y003 Pulse output stop 342 -|M8147|Y000 monitoring during pulse output|SM880|Y000 monitoring during pulse output 343 -|M8148|Y001 Monitoring during pulse output|SM940|Y001 Monitoring during pulse output 344 -|M8149|Y002 Monitoring during pulse output|SM1000|Y002 Monitoring during pulse output 345 -|M8150|Y003 Monitoring during pulse output|SM1060|Y003 Monitoring during pulse output 346 -|(% rowspan="4" %)((( 346 +|=(% scope="row" %)**3V**|=**Description**|=**5V**|=**Description** 347 +|=M8145|Y000 pulse output stop|SM898|Y000 pulse output stop 348 +|=M8146|Y001 Pulse output stop|SM958|Y001 Pulse output stop 349 +|=M8152|Y002 pulse output stop|SM1018|Y002 pulse output stop 350 +|=M8153|Y003 Pulse output stop|SM1078|Y003 Pulse output stop 351 +|=M8147|Y000 monitoring during pulse output|SM880|Y000 monitoring during pulse output 352 +|=M8148|Y001 Monitoring during pulse output|SM940|Y001 Monitoring during pulse output 353 +|=M8149|Y002 Monitoring during pulse output|SM1000|Y002 Monitoring during pulse output 354 +|=M8150|Y003 Monitoring during pulse output|SM1060|Y003 Monitoring during pulse output 355 +|=(% rowspan="4" %)((( 347 347 348 348 349 349 ... ... @@ -353,35 +353,35 @@ 353 353 354 354 Some instructions (PLSR, etc.) instruction execution completed (Y0-Y3) 355 355 )))|SM882|Y0 pulse sending completed 356 -|SM942|Y1 pulse sending completed 357 -|SM1002|Y2 pulse transmission completed 358 -|SM1062|Y3 pulse transmission completed 359 -|M8134|Y0's thousandth control bit|SM897|Y0's thousandth control bit 360 -|M8135|((( 365 +|=SM942|Y1 pulse sending completed 366 +|=SM1002|Y2 pulse transmission completed 367 +|=SM1062|Y3 pulse transmission completed 368 +|=M8134|Y0's thousandth control bit|SM897|Y0's thousandth control bit 369 +|=M8135|((( 361 361 The acceleration and deceleration time between each axis of Y1's thousandth control position positioning command is separated 362 362 )))|((( 363 363 SM957 364 364 )))|Y1 Perimeter control bit 365 -|M8136|Y2 Perimeter control bit|SM1017|Y2 Perimeter control bit 366 -|M8137|Y3 Perimeter control bit|SM1077|Y3 Perimeter control bit 374 +|=M8136|Y2 Perimeter control bit|SM1017|Y2 Perimeter control bit 375 +|=M8137|Y3 Perimeter control bit|SM1077|Y3 Perimeter control bit 367 367 368 368 3. Comparison of word devices 369 369 370 370 (% class="table-bordered" %) 371 -|**3V**|**Description**|**5V**|**Description** 372 -|D8104|Y0 acceleration and deceleration time (open M8135)|SD902/SD962|Y0 acceleration/deceleration time 373 -|D8105|Y1 acceleration and deceleration time (open M8135)|SD1022/SD1082|Y1 acceleration/deceleration time 374 -|D8106|Y2 acceleration and deceleration time (open M8135)|SD1142/SD1202|Y2 acceleration/deceleration time 375 -|D8107|Y3 acceleration and deceleration time (open M8135)|SD1262/SD1322|Y3 acceleration/deceleration time 376 -|D8140|Y000 Current position low|SD880|Y000 Current position low 377 -|D8141|Y000 current position high|SD881|Y000 current position high 378 -|D8142|Y001 Current position low|SD940|Y001 Current position low 379 -|D8143|Y001 Current position high|SD941|Y001 Current position high 380 -|D8150|Y002 current position low|SD1000|Y002 current position low 381 -|D8151|Y002 current position high|SD1001|Y002 current position high 382 -|D8152|Y003 Current position low|SD1060|Y003 Current position low 383 -|D8153|Y003 Current position high|SD1061|Y003 Current position high 384 -|(% rowspan="4" %)((( 380 +|=(% scope="row" %)**3V**|=**Description**|=**5V**|=**Description** 381 +|=D8104|Y0 acceleration and deceleration time (open M8135)|SD902/SD962|Y0 acceleration/deceleration time 382 +|=D8105|Y1 acceleration and deceleration time (open M8135)|SD1022/SD1082|Y1 acceleration/deceleration time 383 +|=D8106|Y2 acceleration and deceleration time (open M8135)|SD1142/SD1202|Y2 acceleration/deceleration time 384 +|=D8107|Y3 acceleration and deceleration time (open M8135)|SD1262/SD1322|Y3 acceleration/deceleration time 385 +|=D8140|Y000 Current position low|SD880|Y000 Current position low 386 +|=D8141|Y000 current position high|SD881|Y000 current position high 387 +|=D8142|Y001 Current position low|SD940|Y001 Current position low 388 +|=D8143|Y001 Current position high|SD941|Y001 Current position high 389 +|=D8150|Y002 current position low|SD1000|Y002 current position low 390 +|=D8151|Y002 current position high|SD1001|Y002 current position high 391 +|=D8152|Y003 Current position low|SD1060|Y003 Current position low 392 +|=D8153|Y003 Current position high|SD1061|Y003 Current position high 393 +|=(% rowspan="4" %)((( 385 385 386 386 387 387 ... ... @@ -392,10 +392,10 @@ 392 392 393 393 Y0-Y3 Paranoid speed (single word) 394 394 )))|SD900, SD901|Y0 Paranoid speed (double word) 395 -|SD960, SD961|Y1 Paranoid speed (double word) 396 -|SD1020, SD1021|Y2 Paranoid speed (double word) 397 -|SD1080, SD1081|Y3 Paranoid speed (double word) 398 -|(% rowspan="8" %)((( 404 +|=SD960, SD961|Y1 Paranoid speed (double word) 405 +|=SD1020, SD1021|Y2 Paranoid speed (double word) 406 +|=SD1080, SD1081|Y3 Paranoid speed (double word) 407 +|=(% rowspan="8" %)((( 399 399 400 400 401 401 ... ... @@ -410,14 +410,14 @@ 410 410 411 411 Y0-Y3 maximum frequency (double word) 412 412 )))|SD898|Y0 Maximum speed low 413 -|SD899|Y0 Highest speed 414 -|SD958|Y1 Maximum speed low 415 -|SD959|Y1 Highest speed 416 -|SD1018|Y2 Maximum speed low 417 -|SD1019|Y2 Highest speed 418 -|SD1078|Y3 Maximum speed low 419 -|SD1079|Y3 Highest speed 420 -|(% rowspan="4" %)((( 422 +|=SD899|Y0 Highest speed 423 +|=SD958|Y1 Maximum speed low 424 +|=SD959|Y1 Highest speed 425 +|=SD1018|Y2 Maximum speed low 426 +|=SD1019|Y2 Highest speed 427 +|=SD1078|Y3 Maximum speed low 428 +|=SD1079|Y3 Highest speed 429 +|=(% rowspan="4" %)((( 421 421 422 422 423 423 ... ... @@ -427,9 +427,9 @@ 427 427 428 428 4-axis acceleration/deceleration time (when M8135 is not turned on) 429 429 )))|SD902/SD962|Y0 acceleration/deceleration time 430 -|SD1022/SD1082|Y1 acceleration/deceleration time 431 -|SD1142/SD1202|Y2 acceleration/deceleration time 432 -|SD1262/SD1322|Y3 acceleration/deceleration time 439 +|=SD1022/SD1082|Y1 acceleration/deceleration time 440 +|=SD1142/SD1202|Y2 acceleration/deceleration time 441 +|=SD1262/SD1322|Y3 acceleration/deceleration time 433 433 434 434 4. New features of high-speed pulse instructions on LX5V 435 435 ... ... @@ -455,7 +455,7 @@ 455 455 456 456 ⑨Support direction reversal (can set the forward direction to low level) 457 457 458 -= ** 8.Communication function** =467 += **7 Communication function** = 459 459 460 460 **~1. Communication parameter configuration** 461 461 ... ... @@ -466,27 +466,27 @@ 466 466 3V settings: 467 467 468 468 (% class="table-bordered" %) 469 -|**protocol**|**D8126 value setting** 470 -|RS instruction (custom protocol)|00H 471 -|HMI monitoring protocol (PLC protocol)|01H 472 -|MODBUS-RTU slave|02H 473 -|MODBUS-ASCII slave|03H 474 -|N:N network communication protocol slave|04H 475 -|RS instruction (custom protocol)|10H 476 -|MODBUS-RTU master station|20H 477 -|MODBUS-ASCII master station|30H 478 -|N:N network communication protocol master station|40H 478 +|=(% scope="row" %)**protocol**|=**D8126 value setting** 479 +|=RS instruction (custom protocol)|00H 480 +|=HMI monitoring protocol (PLC protocol)|01H 481 +|=MODBUS-RTU slave|02H 482 +|=MODBUS-ASCII slave|03H 483 +|=N:N network communication protocol slave|04H 484 +|=RS instruction (custom protocol)|10H 485 +|=MODBUS-RTU master station|20H 486 +|=MODBUS-ASCII master station|30H 487 +|=N:N network communication protocol master station|40H 479 479 480 480 5V settings: 481 481 482 482 (% class="table-bordered" %) 483 -|**SD2592 value setting**|**Protocol** 484 -|0 H|Wecon Modbus slave 485 -|2 H|ModbusRTU slave 486 -|3 H|ModbusASCII slave 487 -|10 H|User-defined protocol 488 -|20 H|ModbusRTU master station 489 -|30 H|((( 492 +|=(% scope="row" %)**SD2592 value setting**|=**Protocol** 493 +|=0 H|Wecon Modbus slave 494 +|=2 H|ModbusRTU slave 495 +|=3 H|ModbusASCII slave 496 +|=10 H|User-defined protocol 497 +|=20 H|ModbusRTU master station 498 +|=30 H|((( 490 490 ModbusASCII master 491 491 492 492 ... ... @@ -503,34 +503,31 @@ 503 503 5V address: 504 504 505 505 (% class="table-bordered" %) 506 -|Port|Occupy|(% style="width:240px" %)Address range|(% style="width:221px" %)((( 515 +|=(% scope="row" %)Port|=Occupy|=(% style="width: 240px;" %)Address range|=(% style="width: 221px;" %)((( 507 507 10 hex Register 508 -)))|((( 517 +)))|=((( 509 509 Total reserved land Address size 510 510 ))) 511 -|**Word address**| |(% style="width:240px" %) |(% style="width:221px" %) | 512 -|T0~~T511|512 WORD|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %)0|1536 513 -|C0~~C255|256 WORD|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024 514 -|LC0~~LC255|512 WORD|(% style="width:240px" %)0x0A00-0x0BFF|(% style="width:221px" %)2560|1024 515 -|HSC0~~HSC15|128 WORD|(% style="width:240px" %)0x0E00-0x0E1F|(% style="width:221px" %)3584|512 516 -|D0~~D7999|8000 WORD|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384 517 -|SD0~~SD4095|4096 WORD|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288 518 -|R0~~R30000|30000 WORD|(% style="width:240px" %)0x8000-0xF52F|(% style="width:221px" %)32768|30000 519 -|**Bit address**| |(% style="width:240px" %) |(% style="width:221px" %) | 520 -|T0~~T511|512 bit|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %) |1536 521 -|C0~~C255|256 bit|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024 522 -|LC0~~LC255|256 bit|(% style="width:240px" %)0x0A00-0x0AFF|(% style="width:221px" %)2560|1024 523 -|HSC0~~HSC15|64 bit|(% style="width:240px" %)0x0E00-0x0E0F|(% style="width:221px" %)3584|512 524 -|M0~~M8000|8192bit|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384 525 -|SM0~~SM4095|4096bit|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288 526 -|Reserved| |(% style="width:240px" %)0x8000-0xBFFF|(% style="width:221px" %) |16383 527 -|S0~~S4095|4096bit|(% style="width:240px" %)0xC000-0xCFFF|(% style="width:221px" %)49152|8192 528 -|X0~~X1023|1024bit|(% style="width:240px" %)0xE000-0xE3FF|(% style="width:221px" %)57344|4096 529 -|Y0~~Y1023|1024bit|(% style="width:240px" %)0xF000-0xF3FF|(% style="width:221px" %)61440|4096 520 +|=**Word address**| |(% style="width:240px" %) |(% style="width:221px" %) | 521 +|=T0~~T511|512 WORD|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %)0|1536 522 +|=C0~~C255|256 WORD|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024 523 +|=LC0~~LC255|512 WORD|(% style="width:240px" %)0x0A00-0x0BFF|(% style="width:221px" %)2560|1024 524 +|=HSC0~~HSC15|128 WORD|(% style="width:240px" %)0x0E00-0x0E1F|(% style="width:221px" %)3584|512 525 +|=D0~~D7999|8000 WORD|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384 526 +|=SD0~~SD4095|4096 WORD|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288 527 +|=R0~~R30000|30000 WORD|(% style="width:240px" %)0x8000-0xF52F|(% style="width:221px" %)32768|30000 528 +|=**Bit address**| |(% style="width:240px" %) |(% style="width:221px" %) | 529 +|=T0~~T511|512 bit|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %) |1536 530 +|=C0~~C255|256 bit|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024 531 +|=LC0~~LC255|256 bit|(% style="width:240px" %)0x0A00-0x0AFF|(% style="width:221px" %)2560|1024 532 +|=HSC0~~HSC15|64 bit|(% style="width:240px" %)0x0E00-0x0E0F|(% style="width:221px" %)3584|512 533 +|=M0~~M8000|8192bit|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384 534 +|=SM0~~SM4095|4096bit|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288 535 +|=Reserved| |(% style="width:240px" %)0x8000-0xBFFF|(% style="width:221px" %) |16383 536 +|=S0~~S4095|4096bit|(% style="width:240px" %)0xC000-0xCFFF|(% style="width:221px" %)49152|8192 537 +|=X0~~X1023|1024bit|(% style="width:240px" %)0xE000-0xE3FF|(% style="width:221px" %)57344|4096 538 +|=Y0~~Y1023|1024bit|(% style="width:240px" %)0xF000-0xF3FF|(% style="width:221px" %)61440|4096 530 530 531 531 **5. LX5V added functions** 532 532 533 533 Modify serial communication parameters during RUN. For example, use PROTOCOL instruction to modify the protocol during run. The corresponding instruction description can also find the method of setting without instruction. For details, please refer to the relevant instructions of the instruction. Commands are PROTOCOL (set serial port protocol), PROTPARA (set serial port parameters), STATION (set station number) 534 - 535 - 536 -
- 企业微信截图_16762524911554.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.4 KB - Content