Changes for page 17 LX3V/5V/5S comparsion

Last modified by Jim on 2025/02/11 11:34

From version 8.1
edited by Jim
on 2022/06/14 15:14
Change comment: There is no comment for this version
To version 2.1
edited by Jim
on 2022/06/14 14:48
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -03 Difference between 3V, 5V and 5S
1 +Difference between 3V, 5V and 5S
Content
... ... @@ -1,63 +1,7 @@
1 -= **1 Basic difference between 3V, 5V and 5S** =
1 += **1.** **Functions that 3V has but 5V does not** =
2 2  
3 -|Functions|5V|5S|3V
4 -|Running Mode|(% colspan="3" %)Cyclic scan /Interrupt
5 -|Power supply|(% colspan="3" %)A:AC 220V;D:DC 24V
6 -|Output type|MT:Transistor|MT:Transistor;MR:Relay|MT:Transistor;MR:Relay
7 -|I/O|1212;1412;1616;2416;2424;3624;|0806;1208;1212;1412;
8 -1616;2416;2424;3624;|0806;1208;1212;1412;
9 -1616;2416;2424;3624;
10 -|Programming|(% colspan="3" %)Ladder
11 -|Type of instruction| | |
12 -|Execute Time|Basic 0.01-0.03μs|Basic 0.03-0.08μs|Basic 0.06μs/Applied instruction:1-10us
13 -|Program Capacity|(% colspan="2" %)512KB|16k
14 -|High Speed Pulse Output|≤1412MT and smaller: 4*200KHz;
15 -≥1616MT and bigger:  8*200KHz。|MT/MR2H: 2* 200KHz;
16 -MT4H: 4* 200KHz。|MT/2H: 2*100KHZ, or 4H: 4*100, single: 200kHZ
17 -|High speed counter Interrupt|(% colspan="2" %)100 channels|21channels
18 -|Timer Interrupt|(% colspan="2" %)100 channels,Support 0.1ms Interrupt|95 channels
19 -|X Interrupt|X0-X7 Rising & Falling|X0-X5 Rising & Falling|X0-X5 Rising & Falling
20 -|**High speed counter Single Phase**|**≤1412 and smaller: 4*150KHz
21 -≥1616 and bigger: 8*150KHz**|**≤1412 and smaller: 2*150KHz;4*10KHz
22 -≥1616 and bigger: 6*150KHz**|**2*200KHz; 4*10KHz**
23 -|**High speed counter AB phase**|**≤1412 and smaller: 4*100KHz
24 -≥1616 and bigger: 8*100KHz**|**≤1412 and smaller: 1*100KHz+2*10KHz
25 -≥1616 and bigger: 3*100KHz**|**2*100KHz**
26 -|Storage Type|(% colspan="3" %)FLASH
27 -|Serial Communication|(((
28 -COM1: RS422、RS485;COM2: RS485
29 -)))|1208 and smaller: COM1: RS422;COM2: RS485;
30 -1212 and bigger: COM1: RS422、RS485;COM2:RS485|1208 and smaller: COM1: RS422;COM2: RS485;
31 -1212 and bigger: COM1: RS422、RS485;COM2: RS485
32 -|BD board support|yes|yes|yes
33 -|Communication BD board|(% colspan="2" %)inbuilt ethernet port series, RS485 BD board in developing |RS485 BD support, 3vp supports ethernet bd board
34 -|Expansion Module|(% colspan="2" %)yes √ (1212 and bigger can support)|yes √ (1212 and bigger can support)
35 -|Electronic CAM|√(2 sheets for switch)|√(2 sheets for switch)|N/A
36 -|S-type CAM|√|√|N/A
37 -|N:N Comm|√|√|N/A
38 -|Linear Interpolation|√|√|N/A
39 -|Circular Interpolation|√|√|N/A
40 -|sub-rotine|√|√|N/A
41 -| | | |
3 +== **1.1 BD board** ==
42 42  
43 -= **2 Software interface difference between 5S and 5V** =
44 -
45 -== **2.1 High speed counter configuration** ==
46 -
47 -**5V as below**
48 -
49 -[[image:image-20220614151005-1.png]]
50 -
51 -**5S is as below**
52 -
53 -[[image:image-20220614151015-2.png]]
54 -
55 -**More detail information,please check the product catalog**
56 -
57 -= **3** **Functions that 3V has but 5V does not** =
58 -
59 -== **3.1 BD board** ==
60 -
61 61  LX5V does not support RS485 BD
62 62  
63 63  LX5V does not support Ethernet BD
... ... @@ -64,15 +64,15 @@
64 64  
65 65  LX5V does not support CAN BD
66 66  
67 -== **3.2 Analog BD board expansion address** ==
11 +== **1.2 Analog BD board expansion address** ==
68 68  
69 69  Provides the function of analog board BD to modify parameters such as filtering. For specific functions, please refer to the BD board manual.
70 70  
71 -== **3.3 PLDID** ==
15 +== **1.3 PLDID** ==
72 72  
73 73  Program label function, when the label of the program corresponds to the label of the PLC, the ladder diagram can be uploaded and downloaded. Clearing the memory does not clear this tag either. It is mainly to limit the ladder diagram used by PLC.
74 74  
75 -== **3.4 Instructions** ==
19 +== **1.4 Instructions** ==
76 76  
77 77  (1) NOP instruction (null instruction)
78 78  
... ... @@ -96,9 +96,9 @@
96 96  
97 97  (11) CPAVL instruction(communication BD configuration)
98 98  
99 -== **3.5 Unsupported special register function (M8000, D8000)** ==
43 +== **1.5 Unsupported special register function (M8000, D8000)** ==
100 100  
101 -=== **3.5.1 Clock related** ===
45 +=== **1.5.1 Clock related** ===
102 102  
103 103  Clock function not supported by LX5V
104 104  
... ... @@ -110,13 +110,13 @@
110 110  |M8018|install and examine
111 111  |M8019|Real-time clock (RTC) error
112 112  
113 -=== **3.5.2 High-speed counter ring counting function** ===
57 +=== **1.5.2 High-speed counter ring counting function** ===
114 114  
115 115  (% class="table-bordered" %)
116 116  |M8099|High-speed ring counter count start
117 117  |M8099|Ring count configuration
118 118  
119 -=== **3.5.3 X0~~X5 pulse capture function** ===
63 +=== **1.5.3 X0~~X5 pulse capture function** ===
120 120  
121 121  (% class="table-bordered" %)
122 122  |M8170|X000 pulse capture
... ... @@ -126,15 +126,15 @@
126 126  |M8174|X004 pulse capture
127 127  |M8175|X005 pulse capture
128 128  
129 -= **4. 5V function under development** =
73 += **2. 5V function under development** =
130 130  
131 131  N:N communication protocol
132 132  
133 133  Interpolation instructions (G90G01, G90G02, G90G03, G91G01, G91G02, G91G03)
134 134  
135 -= **5. 3V and 5V incompatible functions (These can be automatically converted in the future)** =
79 += **3. 3V and 5V incompatible functions (These can be automatically converted in the future)** =
136 136  
137 -== **5.1 General register** ==
81 +== **3.1 General register** ==
138 138  
139 139  (% class="table-bordered" %)
140 140  |**register**|**LX3V**|**LX5V**|**Remarks**
... ... @@ -164,9 +164,9 @@
164 164  
165 165  5. Pointer I is cancelled in LX5V, please check the programming mode for details.
166 166  
167 -== **5.2 Programming method** ==
111 +== **3.2 Programming method** ==
168 168  
169 -=== **5.2.1 Subroutine (For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)** ===
113 +=== **3.2.1 Subroutine (For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)** ===
170 170  
171 171  **Use of LX3V subroutines**
172 172  [[image:1652684087594-147.png]]
... ... @@ -181,7 +181,7 @@
181 181  
182 182  [[image:1652684829740-769.png]]
183 183  
184 -=== **5.2.2 Interrupt (For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)** ===
128 +=== **3.2.2 Interrupt (For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)** ===
185 185  
186 186  **LX3V interrupt**
187 187  
... ... @@ -201,7 +201,7 @@
201 201  
202 202  [[image:1652685809566-630.png]]
203 203  
204 -=== **5.2.3 Instructions** ===
148 +=== **3.2.3 Instructions** ===
205 205  
206 206  **OUT command**
207 207  
... ... @@ -269,9 +269,9 @@
269 269  
270 270  [[image:1652689626279-240.png]]
271 271  
272 -= **6. High-speed input function** =
216 += **4. High-speed input function** =
273 273  
274 -== **6.1 Use on LX3V** ==
218 +== **4.1 Use on LX3V** ==
275 275  
276 276  Find the high-speed input counter you need to use according to the following table:
277 277  
... ... @@ -283,7 +283,7 @@
283 283  
284 284  [[image:1652690126303-800.png]]
285 285  
286 -== **6.2 Use on LX5V** ==
230 +== **4.2 Use on LX5V** ==
287 287  
288 288  According to channel, select the HSC register to use:
289 289  
... ... @@ -297,7 +297,7 @@
297 297  
298 298  [[image:1652692388207-617.png]]
299 299  
300 -== **6.3 Difference between high-speed counters on LX5V and LX3V** ==
244 +== **4.3 Difference between high-speed counters on LX5V and LX3V** ==
301 301  
302 302  LX3V updates the count value when the OUT instruction is executed, which is affected by the scan cycle.
303 303  
... ... @@ -308,7 +308,7 @@
308 308  
309 309  LX5V high-speed input counter will update the input frequency in the special soft element (SD) every 100us.
310 310  
311 -= **7. High-speed output function** =
255 += **5. High-speed output function** =
312 312  
313 313  **High-speed pulse commands are the same in the use of commands.**
314 314  
... ... @@ -455,7 +455,7 @@
455 455  
456 456  ⑨Support direction reversal (can set the forward direction to low level)
457 457  
458 -= **8. Communication function** =
402 += **6. Communication function** =
459 459  
460 460  **~1. Communication parameter configuration**
461 461  
image-20220614151005-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Jim
Size
... ... @@ -1,1 +1,0 @@
1 -25.3 KB
Content
image-20220614151015-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Jim
Size
... ... @@ -1,1 +1,0 @@
1 -25.3 KB
Content