Changes for page 17 LX3V/5V/5S comparsion
Last modified by Jim on 2025/02/11 11:34
Summary
-
Page properties (4 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - 03Difference between3V,5V and 5S1 +17 LX3V/5V/5S comparsion - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PLC Editor2. 1 User manual.WebHome1 +PLC Editor2.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. admin1 +XWiki.Jim - Content
-
... ... @@ -1,4 +1,4 @@ 1 -= **1 Basic difference between 3V, 5V and 5S** =1 += **1 Basic differences** = 2 2 3 3 |=(% scope="row" %)Functions|=5V|=5S|=3V 4 4 |=Running Mode|(% colspan="3" %)Cyclic scan /Interrupt ... ... @@ -8,7 +8,6 @@ 8 8 1616;2416;2424;3624;|0806;1208;1212;1412; 9 9 1616;2416;2424;3624; 10 10 |=Programming|(% colspan="3" %)Ladder 11 -|=Type of instruction| | | 12 12 |=Execute Time|Basic 0.01-0.03μs|Basic 0.03-0.08μs|Basic 0.06μs/Applied instruction:1-10us 13 13 |=Program Capacity|(% colspan="2" %)512KB|16k 14 14 |=High Speed Pulse Output|≤1412MT and smaller: 4*200KHz; ... ... @@ -19,10 +19,22 @@ 19 19 |=X Interrupt|X0-X7 Rising & Falling|X0-X5 Rising & Falling|X0-X5 Rising & Falling 20 20 |=**High speed counter Single Phase**|**≤1412 and smaller: 4*150KHz 21 21 ≥1616 and bigger: 8*150KHz**|**≤1412 and smaller: 2*150KHz;4*10KHz 22 -≥1616 and bigger: 6*150KHz**|**2*200KHz; 4*10KHz** 21 +≥1616 and bigger: 6*150KHz**|((( 22 +**Hardware counter for the first two channels:2*200KHz;** 23 + 24 +**Software counter for the first two channels:2*100KHz;** 25 + 26 +**Software counter for back four channels:4*10KHz** 27 +))) 23 23 |=**High speed counter AB phase**|**≤1412 and smaller: 4*100KHz 24 24 ≥1616 and bigger: 8*100KHz**|**≤1412 and smaller: 1*100KHz+2*10KHz 25 -≥1616 and bigger: 3*100KHz**|**2*100KHz** 30 +≥1616 and bigger: 3*100KHz**|((( 31 +**Hardware counter for the first two channels:2*100KHz;** 32 + 33 +**Software counter for the first two channels:2*50KHz;** 34 + 35 +**Software counter for back four channels:4*5KHz** 36 +))) 26 26 |=Storage Type|(% colspan="3" %)FLASH 27 27 |=Serial Communication|((( 28 28 COM1: RS422、RS485;COM2: RS485 ... ... @@ -30,19 +30,18 @@ 30 30 1212 and bigger: COM1: RS422、RS485;COM2:RS485|1208 and smaller: COM1: RS422;COM2: RS485; 31 31 1212 and bigger: COM1: RS422、RS485;COM2: RS485 32 32 |=BD board support|yes|yes|yes 33 -|=Communication BD board|(% colspan="2" %) inbuilt ethernetportseries,RS485board ineveloping|RS485 BD support, 3vp supports ethernet bd board44 +|=Communication BD board|(% colspan="2" %)support LX5V-2RS485-BD and LX5V-ETH-BD|RS485 BD support, 3vp supports ethernet bd board 34 34 |=Expansion Module|(% colspan="2" %)yes √ (1212 and bigger can support)|yes √ (1212 and bigger can support) 35 35 |=Electronic CAM|√(2 sheets for switch)|√(2 sheets for switch)|N/A 36 36 |=S-type CAM|√|√|N/A 37 -|= N:NComm|√|√|N/A48 +|=PLClink|√|√|N/A 38 38 |=Linear Interpolation|√|√|N/A 39 39 |=Circular Interpolation|√|√|N/A 40 40 |=sub-rotine|√|√|N/A 41 -|= | | | 42 42 43 -= **2 Software interfacedifference between 5Sand5V** =53 += **2 Software difference between 5S vs 5V** = 44 44 45 -== ** 2.1High speed counter configuration** ==55 +== **High speed counter configuration** == 46 46 47 47 **5V as below** 48 48 ... ... @@ -50,29 +50,29 @@ 50 50 51 51 **5S is as below** 52 52 53 -[[image: image-20220614151015-2.png]]63 +[[image:企业微信截图_16762524911554.png]] 54 54 55 55 **More detail information,please check the product catalog** 56 56 57 57 = **3** **Functions that 3V has but 5V does not** = 58 58 59 -== ** 3.1BD board** ==69 +== **BD board** == 60 60 61 -LX5V does not support RS485 71 +LX5V does not support LX3V-2RS485-BD 62 62 63 -LX5V does not support E thernetBD73 +LX5V does not support LX3V-ETH-BD 64 64 65 - LX5VdoesnotsupportCAN BD75 +== **Analog BD board expansion address** == 66 66 67 -== **3.2 Analog BD board expansion address** == 77 +Provides the function of analog board BD to modify parameters such as filtering. For specific functions, please refer to the below link: 78 +~1. LX3 series: [[5-9 System-special address - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor/05%20Registers/5-9%20system-special%20address/#HCOM1communicationsettings26BDmoduleconfiguration]] 79 +2. LX5 series: [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule]] [[15 Appendix - Wecon (we-con.com.cn)>>url:https://docs.we-con.com.cn/bin/view/PLC%20Editor2/15/#HBDboardmodule-1]] 68 68 69 - Providesthe function of analog board BDto modify parameters such as filtering. For specific functions, please refer to the BDboard manual.81 +== **PLDID** == 70 70 71 -== **3.3 PLDID** == 72 - 73 73 Program label function, when the label of the program corresponds to the label of the PLC, the ladder diagram can be uploaded and downloaded. Clearing the memory does not clear this tag either. It is mainly to limit the ladder diagram used by PLC. 74 74 75 -== ** 3.4Instructions** ==85 +== **Instructions** == 76 76 77 77 (1) NOP instruction (null instruction) 78 78 ... ... @@ -96,14 +96,13 @@ 96 96 97 97 (11) CPAVL instruction(communication BD configuration) 98 98 99 -== ** 3.5Unsupported special register function (M8000, D8000)** ==109 +== **Unsupported special register function (M8000, D8000)** == 100 100 101 -=== ** 3.5.1Clock related** ===111 +=== **Clock related** === 102 102 103 103 Clock function not supported by LX5V 104 104 105 -(% class="table-bordered" %) 106 -|=(% scope="row" %)M8014|Oscillation clock with 1 minute clock period 115 +|=M8014|Oscillation clock with 1 minute clock period 107 107 |=M8015|Clock stop and preset 108 108 |=M8016|Stop time to read the display 109 109 |=M8017|±30 seconds correction ... ... @@ -110,16 +110,14 @@ 110 110 |=M8018|install and examine 111 111 |=M8019|Real-time clock (RTC) error 112 112 113 -=== ** 3.5.2High-speed counter ring counting function** ===122 +=== **High-speed counter ring counting function** === 114 114 115 -(% class="table-bordered" %) 116 -|=(% scope="row" %)M8099|High-speed ring counter count start 124 +|=M8099|High-speed ring counter count start 117 117 |=M8099|Ring count configuration 118 118 119 -=== ** 3.5.3X0~~X5 pulse capture function** ===127 +=== **X0~~X5 pulse capture function** === 120 120 121 -(% class="table-bordered" %) 122 -|=(% scope="row" %)M8170|X000 pulse capture 129 +|=M8170|X000 pulse capture 123 123 |=M8171|X001 pulse capture 124 124 |=M8172|X002 pulse capture 125 125 |=M8173|X003 pulse capture ... ... @@ -126,16 +126,13 @@ 126 126 |=M8174|X004 pulse capture 127 127 |=M8175|X005 pulse capture 128 128 129 -= **4 .5Vfunctionunder development** =136 += **4 3V and 5V incompatible functions** = 130 130 131 -N:N communication protocol 138 +(% class="wikigeneratedid" %) 139 +**(These can be automatically converted in the future)** 132 132 133 - Interpolationinstructions(G90G01, G90G02, G90G03, G91G01, G91G02, G91G03)141 +== **General register** == 134 134 135 -= **5. 3V and 5V incompatible functions (These can be automatically converted in the future)** = 136 - 137 -== **5.1 General register** == 138 - 139 139 (% class="table-bordered" %) 140 140 |=(% scope="row" %)**register**|=**LX3V**|=**LX5V**|=**Remarks** 141 141 |=Input|X0~~X377|X0~~X1777| ... ... @@ -164,10 +164,13 @@ 164 164 165 165 5. Pointer I is cancelled in LX5V, please check the programming mode for details. 166 166 167 -== ** 5.2Programming method** ==171 +== **Programming method** == 168 168 169 -=== ** 5.2.1Subroutine(For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)** ===173 +=== **Subroutine** === 170 170 175 +(% class="wikigeneratedid" %) 176 +**(For details, please refer to LX5V Programming Manual Chapter 1.4-Subroutine Branch)** 177 + 171 171 **Use of LX3V subroutines** 172 172 [[image:1652684087594-147.png]] 173 173 ... ... @@ -181,8 +181,11 @@ 181 181 182 182 [[image:1652684829740-769.png]] 183 183 184 -=== ** 5.2.2Interrupt(For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)** ===191 +=== **Interrupt** === 185 185 193 +(% class="wikigeneratedid" %) 194 +**(For details, please refer to LX5V Programming Manual Chapter 1.4-Branch)** 195 + 186 186 **LX3V interrupt** 187 187 188 188 The interrupt program is under FEND and returns with IRET. The meaning of the specific interrupt is distinguished by the pointer I number.(Refer to EI/DI instruction in 3V) ... ... @@ -201,9 +201,9 @@ 201 201 202 202 [[image:1652685809566-630.png]] 203 203 204 -=== ** 5.2.3Instructions** ===214 +=== **Instructions** === 205 205 206 -**OUT co mmand**216 +**OUT instruction** 207 207 208 208 Double word counter[[image:file:///C:\Users\ANNAXU~~1\AppData\Local\Temp\ksohtml14432\wps28.png]] 209 209 ... ... @@ -269,9 +269,9 @@ 269 269 270 270 [[image:1652689626279-240.png]] 271 271 272 -= ** 6.High-speed input function** =282 += **5 High-speed input function** = 273 273 274 -== ** 6.1Use on LX3V** ==284 +== **Use on LX3V** == 275 275 276 276 Find the high-speed input counter you need to use according to the following table: 277 277 ... ... @@ -283,7 +283,7 @@ 283 283 284 284 [[image:1652690126303-800.png]] 285 285 286 -== ** 6.2Use on LX5V** ==296 +== **Use on LX5V** == 287 287 288 288 According to channel, select the HSC register to use: 289 289 ... ... @@ -297,11 +297,10 @@ 297 297 298 298 [[image:1652692388207-617.png]] 299 299 300 -== ** 6.3Difference between high-speed counters on LX5V and LX3V** ==310 +== **Difference between high-speed counters on LX5V and LX3V** == 301 301 302 302 LX3V updates the count value when the OUT instruction is executed, which is affected by the scan cycle. 303 303 304 - 305 305 LX5V is updated in the 100us interrupt, not affected by the scan cycle, and provides the REF instruction to refresh the current high-speed counter value immediately. 306 306 307 307 LX5V single-phase high-speed counter supports filtering function, configurable 0~~17us. ... ... @@ -308,7 +308,7 @@ 308 308 309 309 LX5V high-speed input counter will update the input frequency in the special soft element (SD) every 100us. 310 310 311 -= ** 7.High-speed output function** =320 += **6 High-speed output function** = 312 312 313 313 **High-speed pulse commands are the same in the use of commands.** 314 314 ... ... @@ -455,7 +455,7 @@ 455 455 456 456 ⑨Support direction reversal (can set the forward direction to low level) 457 457 458 -= ** 8.Communication function** =467 += **7 Communication function** = 459 459 460 460 **~1. Communication parameter configuration** 461 461 ... ... @@ -480,13 +480,13 @@ 480 480 5V settings: 481 481 482 482 (% class="table-bordered" %) 483 -|**SD2592 value setting**|**Protocol** 484 -|0 H|Wecon Modbus slave 485 -|2 H|ModbusRTU slave 486 -|3 H|ModbusASCII slave 487 -|10 H|User-defined protocol 488 -|20 H|ModbusRTU master station 489 -|30 H|((( 492 +|=(% scope="row" %)**SD2592 value setting**|=**Protocol** 493 +|=0 H|Wecon Modbus slave 494 +|=2 H|ModbusRTU slave 495 +|=3 H|ModbusASCII slave 496 +|=10 H|User-defined protocol 497 +|=20 H|ModbusRTU master station 498 +|=30 H|((( 490 490 ModbusASCII master 491 491 492 492 ... ... @@ -503,34 +503,31 @@ 503 503 5V address: 504 504 505 505 (% class="table-bordered" %) 506 -|Port|Occupy|(% style="width:240px" %)Address range|(% style="width:221px" %)((( 515 +|=(% scope="row" %)Port|=Occupy|=(% style="width: 240px;" %)Address range|=(% style="width: 221px;" %)((( 507 507 10 hex Register 508 -)))|((( 517 +)))|=((( 509 509 Total reserved land Address size 510 510 ))) 511 -|**Word address**| |(% style="width:240px" %) |(% style="width:221px" %) | 512 -|T0~~T511|512 WORD|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %)0|1536 513 -|C0~~C255|256 WORD|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024 514 -|LC0~~LC255|512 WORD|(% style="width:240px" %)0x0A00-0x0BFF|(% style="width:221px" %)2560|1024 515 -|HSC0~~HSC15|128 WORD|(% style="width:240px" %)0x0E00-0x0E1F|(% style="width:221px" %)3584|512 516 -|D0~~D7999|8000 WORD|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384 517 -|SD0~~SD4095|4096 WORD|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288 518 -|R0~~R30000|30000 WORD|(% style="width:240px" %)0x8000-0xF52F|(% style="width:221px" %)32768|30000 519 -|**Bit address**| |(% style="width:240px" %) |(% style="width:221px" %) | 520 -|T0~~T511|512 bit|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %) |1536 521 -|C0~~C255|256 bit|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024 522 -|LC0~~LC255|256 bit|(% style="width:240px" %)0x0A00-0x0AFF|(% style="width:221px" %)2560|1024 523 -|HSC0~~HSC15|64 bit|(% style="width:240px" %)0x0E00-0x0E0F|(% style="width:221px" %)3584|512 524 -|M0~~M8000|8192bit|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384 525 -|SM0~~SM4095|4096bit|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288 526 -|Reserved| |(% style="width:240px" %)0x8000-0xBFFF|(% style="width:221px" %) |16383 527 -|S0~~S4095|4096bit|(% style="width:240px" %)0xC000-0xCFFF|(% style="width:221px" %)49152|8192 528 -|X0~~X1023|1024bit|(% style="width:240px" %)0xE000-0xE3FF|(% style="width:221px" %)57344|4096 529 -|Y0~~Y1023|1024bit|(% style="width:240px" %)0xF000-0xF3FF|(% style="width:221px" %)61440|4096 520 +|=**Word address**| |(% style="width:240px" %) |(% style="width:221px" %) | 521 +|=T0~~T511|512 WORD|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %)0|1536 522 +|=C0~~C255|256 WORD|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024 523 +|=LC0~~LC255|512 WORD|(% style="width:240px" %)0x0A00-0x0BFF|(% style="width:221px" %)2560|1024 524 +|=HSC0~~HSC15|128 WORD|(% style="width:240px" %)0x0E00-0x0E1F|(% style="width:221px" %)3584|512 525 +|=D0~~D7999|8000 WORD|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384 526 +|=SD0~~SD4095|4096 WORD|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288 527 +|=R0~~R30000|30000 WORD|(% style="width:240px" %)0x8000-0xF52F|(% style="width:221px" %)32768|30000 528 +|=**Bit address**| |(% style="width:240px" %) |(% style="width:221px" %) | 529 +|=T0~~T511|512 bit|(% style="width:240px" %)0x0000-0x01ff|(% style="width:221px" %) |1536 530 +|=C0~~C255|256 bit|(% style="width:240px" %)0x0600-0x06ff|(% style="width:221px" %)1536|1024 531 +|=LC0~~LC255|256 bit|(% style="width:240px" %)0x0A00-0x0AFF|(% style="width:221px" %)2560|1024 532 +|=HSC0~~HSC15|64 bit|(% style="width:240px" %)0x0E00-0x0E0F|(% style="width:221px" %)3584|512 533 +|=M0~~M8000|8192bit|(% style="width:240px" %)0x1000-0x2F3F|(% style="width:221px" %)4096|16384 534 +|=SM0~~SM4095|4096bit|(% style="width:240px" %)0x5000-0x5FFF|(% style="width:221px" %)20480|12288 535 +|=Reserved| |(% style="width:240px" %)0x8000-0xBFFF|(% style="width:221px" %) |16383 536 +|=S0~~S4095|4096bit|(% style="width:240px" %)0xC000-0xCFFF|(% style="width:221px" %)49152|8192 537 +|=X0~~X1023|1024bit|(% style="width:240px" %)0xE000-0xE3FF|(% style="width:221px" %)57344|4096 538 +|=Y0~~Y1023|1024bit|(% style="width:240px" %)0xF000-0xF3FF|(% style="width:221px" %)61440|4096 530 530 531 531 **5. LX5V added functions** 532 532 533 533 Modify serial communication parameters during RUN. For example, use PROTOCOL instruction to modify the protocol during run. The corresponding instruction description can also find the method of setting without instruction. For details, please refer to the relevant instructions of the instruction. Commands are PROTOCOL (set serial port protocol), PROTPARA (set serial port parameters), STATION (set station number) 534 - 535 - 536 -
- 企业微信截图_16762524911554.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.4 KB - Content