Changes for page 03 Sequence control

Last modified by Mora Zhou on 2023/11/22 15:46

From version 3.6
edited by Stone Wu
on 2022/07/28 15:58
Change comment: Update document after refactoring.
To version 6.1
edited by Mora Zhou
on 2023/11/22 15:46
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.Mora
Content
... ... @@ -598,9 +598,12 @@
598 598  (% style="text-align:center" %)
599 599  [[image:新建 DOCX 文档_html_594cb1456a9831b1.png||class="img-thumbnail"]]
600 600  
601 -**{{id name="OLE_LINK156"/}}✎Note: **
601 +(% class="box infomessage" %)
602 +(((
603 +{{id name="OLE_LINK156"/}}
602 602  
603 -For the output relay (Y), if the SET instruction and the RST instruction are executed in the same operation, the instruction result close to the END instruction (end of program) will be output.
605 +**✎Note: **For the output relay (Y), if the SET instruction and the RST instruction are executed in the same operation, the instruction result close to the END instruction (end of program) will be output.
606 +)))
604 604  
605 605  **Error code**
606 606  
... ... @@ -619,7 +619,7 @@
619 619  
620 620  **(2) Offset modification**
621 621  
622 -All the devices used in the SET instruction can be indexed with D data devices (the status register S cannot be modified).
625 +All the devices used in the SET instruction can be indexed with D data devices (The status register S cannot be modified).
623 623  
624 624  D0 to D7999 can be used in index modification.
625 625  
... ... @@ -695,9 +695,12 @@
695 695  (% style="text-align:center" %)
696 696  [[image:新建 DOCX 文档_html_bc583793d90dd044.png||class="img-thumbnail"]]
697 697  
698 -**{{id name="OLE_LINK146"/}}✎Note: **
701 +(% class="box infomessage" %)
702 +(((
703 +**✎Note: **
699 699  
700 700  For timers and counters, when the RST instruction is executed in the program, subroutine, and interrupt program where the RST instruction is jumped, the timer and counter may remain unchanged after reset, and the timer and counter will not operate.
706 +)))
701 701  
702 702  **Error code**
703 703  
... ... @@ -775,9 +775,12 @@
775 775  (% style="text-align:center" %)
776 776  [[image:新建 DOCX 文档_html_87ff2fa9f7df8f73.gif||class="img-thumbnail"]]
777 777  
784 +(% class="box infomessage" %)
785 +(((
778 778  **✎Note: **
779 779  
780 780  If the PLF instruction is jumped by the CJ instruction, or the executed subroutine is not called by the CALL(P) instruction, the device specified in (d) may be turned on for more than one scan. Be careful.
789 +)))
781 781  
782 782  **Error code**
783 783