Changes for page 04 Program flow

Last modified by Devin Chen on 2024/01/28 11:38

From version 6.5
edited by Stone Wu
on 2022/07/28 16:17
Change comment: Renamed from xwiki:PLC Editor2.2\.1 LX5V user manual.04 Program flow.WebHome
To version 1.1
edited by Leo Wei
on 2022/06/08 12:57
Change comment: Imported from XAR

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -04 Program flow
1 +04 Program flow instructions
Parent
... ... @@ -1,1 +1,1 @@
1 -PLC Editor2.2\.1 LX5V user manual.WebHome
1 +PLC Editor2.1 User manual.2\.1 LX5V user manual.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Stone
1 +XWiki.admin
Content
... ... @@ -157,33 +157,41 @@
157 157  In the above program, if each input changes during the jump, the action of each coil is shown in the following table.
158 158  
159 159  (% class="table-bordered" %)
160 -|(% style="width:235px" %)**Content**|(% style="width:292px" %)**Contact state before jump**|(% style="width:549px" %)**Coil action in jump**
161 -|(% rowspan="2" style="width:235px" %)(((
162 -Y,M,S (Y1, M1, S1)
163 -)))|(% style="width:292px" %)X1, X2, X3 OFF|(% style="width:549px" %)Y1, M1, S1 OFF
164 -|(% style="width:292px" %)X1, X2, X3 ON|(% style="width:549px" %)Y1, M1, S1 ON
165 -|(% rowspan="2" style="width:235px" %)(((
166 -1ms, 10ms, 100ms timer (T0)
167 -)))|(% style="width:292px" %)X4 OFF|(% style="width:549px" %)Timer not working
168 -|(% style="width:292px" %)X4 ON|(% style="width:549px" %)Timer interrupt (continue after X0 OFF)
169 -|(% rowspan="2" style="width:235px" %)(((
170 -Program timer (T192)
171 -)))|(% style="width:292px" %)X5 OFF, X6 OFF|(% style="width:549px" %)Timer not working, but the timer is reset when X13 is ON
172 -|(% style="width:292px" %)X5 OFF, X6 ON|(% style="width:549px" %)Timing continues (contact action after X0 OFF)
173 -|(% rowspan="2" style="width:235px" %)(((
174 -Counter (C0)
175 -)))|(% style="width:292px" %)X7 OFF, X10 OFF|(% style="width:549px" %){{id name="OLE_LINK160"/}}Counting interrupt, but it is reset when X13 is ON
176 -|(% style="width:292px" %)X7 OFF, X10 ON|(% style="width:549px" %)Count interruption (continue after X0 OFF)
177 -|(% rowspan="2" style="width:235px" %)(((
160 +|**Content**|**Contact state before jump**|**Coil action in jump**
161 +|(% rowspan="2" %)(((
162 +Y,M,S
163 +
164 +(Y1, M1, S1)
165 +)))|X1, X2, X3 OFF|Y1, M1, S1 OFF
166 +|X1, X2, X3 ON|Y1, M1, S1 ON
167 +|(% rowspan="2" %)(((
168 +1ms, 10ms, 100ms timer
169 +
170 +(T0)
171 +)))|X4 OFF|Timer not working
172 +|X4 ON|Timer interrupt (continue after X0 OFF)
173 +|(% rowspan="2" %)(((
174 +Program timer
175 +
176 +(T192)
177 +)))|X5 OFF, X6 OFF|Timer not working, but the timer is reset when X13 is ON
178 +|X5 OFF, X6 ON|Timing continues (contact action after X0 OFF)
179 +|(% rowspan="2" %)(((
180 +Counter
181 +
182 +(C0)
183 +)))|X7 OFF, X10 OFF|{{id name="OLE_LINK160"/}}Counting interrupt, but it is reset when X13 is ON
184 +|X7 OFF, X10 ON|Count interruption (continue after X0 OFF)
185 +|(% rowspan="2" %)(((
178 178  Application instructions
179 179  
180 180  (MOV)
181 -)))|(% style="width:292px" %)X11 OFF|(% rowspan="2" style="width:549px" %)(((
189 +)))|X11 OFF|(% rowspan="2" %)(((
182 182  Single-cycle application instructions are not executed in the jump
183 183  
184 184  Multi-cycle application instructions are partially executable (such as high-speed pulse instructions)
185 185  )))
186 -|(% style="width:292px" %)X11 ON
194 +|X11 ON
187 187  
188 188  **(3) The relationship between CJ instruction and MC to MCR jump**
189 189  
... ... @@ -213,13 +213,15 @@
213 213  (% class="table-bordered" %)
214 214  |(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(((
215 215  **Offset modification**
216 -)))|(% style="width:211px" %)(((
224 +)))|(((
217 217  **Pulse extension**
218 -)))|(% style="width:214px" %)**other**
219 -|**[D]**|(% style="width:211px" %)**XXP**|(% style="width:214px" %)(((
220 -**Subroutine name**
226 +)))|**other**
227 +|**[D]**|**XXP**|(((
228 +**Subroutine**
229 +
230 +**name**
221 221  )))
222 -|CALL|Parameter 1| |(% style="width:211px" %)●|(% style="width:214px" %)
232 +|CALL|Parameter 1| |●|●
223 223  
224 224  Parameter 1 can only use the subroutine name.
225 225  
... ... @@ -323,7 +323,7 @@
323 323  • When the EI and DI instructions are not enabled, they all maintain the original enabled or forbidden interrupt program execution status. The currently disabled interrupt priority can be viewed in SD151.
324 324  
325 325  (% class="table-bordered" %)
326 -|SD151|(% style="width:297px" %)Currently disabled interrupt priority|(% style="width:571px" %)(((
336 +|SD151|Currently disabled interrupt priority|(((
327 327  According to the interrupt prohibition instruction (DI instruction), the interrupt prohibition instruction (DI instruction) below the specified priority, and the interrupt enable instruction (EI instruction), the priority of the interrupt prohibition will be stored.
328 328  
329 329  0: All priority interrupts are disabled (default);
... ... @@ -333,7 +333,7 @@
333 333  2: Priority 2 interrupt is prohibited;
334 334  
335 335  3: All priority interrupts are allowed
336 -)))|(% style="width:148px" %)R(read only)
346 +)))|R(read only)
337 337  