... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.DevinChen - Content
-
... ... @@ -38,6 +38,8 @@ 38 38 1. Each scan is executed. 39 39 1. One scan is executed. 40 40 41 +(% class="box infomessage" %) 42 +((( 41 41 **✎Note: ** 42 42 43 43 After turning ON the coil of the timer, if the timer whose coil is ON is jumped by the CJ(P) instruction, the measurement will not be performed normally. ... ... @@ -45,6 +45,7 @@ 45 45 When the OUT instruction is jumped by the CJ(P) instruction, the scan time will be shorter. 46 46 47 47 When the CJ(P) instruction is used to jump backward, the scan time will be longer. 50 +))) 48 48 49 49 For the CJ(P) instruction, you can jump to a step smaller than the step number being executed. However, in order to avoid the time limit of the watchdog timer, a method of jumping out of the loop during this period should be considered. 50 50 ... ... @@ -238,6 +238,8 @@ 238 238 (% style="text-align:center" %) 239 239 [[image:4_html_29c8e378dfb34066.png||class="img-thumbnail"]] 240 240 244 +(% class="box infomessage" %) 245 +((( 241 241 **✎Note: ** 242 242 243 243 • Multiple CALL(P) instructions can call the same subprogram, but subprograms with the same program name are not allowed. ... ... @@ -247,6 +247,7 @@ 247 247 • If the 1ms accumulative timer is used in a subroutine (the same in an interrupt program), when it reaches the set value, the output contact will act when the first coil instruction is executed (when the subroutine is executed), so be careful. 248 248 249 249 • The devices that are turned on in the subprogram (the same in the interrupt program) will be retained after the program ends. Therefore, these devices should be reset in the main program after the end of the program. 255 +))) 250 250 251 251 **Error code** 252 252 ... ... @@ -258,7 +258,7 @@ 258 258 259 259 **(1) New subroutine** 260 260 261 -Project management→Subroutine→ Scan→Right click to create267 +Project management→Subroutine→Right click to create 262 262 263 263 (% style="text-align:center" %) 264 264 [[image:4_html_3d0d21476f0bb476.png||class="img-thumbnail"]]