Changes for page 05 Timer and counter
Last modified by Leo Wei on 2024/12/24 22:38
Summary
-
Page properties (4 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -05 Timer and counter 1 +05 Timer and counter output instructions - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PLC Editor2.2\.1 LX5V user manual.WebHome 1 +PLC Editor2.1 User manual.2\.1 LX5V user manual.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.admin - Content
-
... ... @@ -15,15 +15,15 @@ 15 15 16 16 **Device used** 17 17 18 -(% class="table-bordered" style="width:1 111px" %)19 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" style="width:130px"%)**Parameter**|(% colspan="11" style="width:486px" %)**Devices**|(% style="width:201px" %)(((18 +(% class="table-bordered" style="width:1200px" %) 19 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="11" style="width:512px" %)**Devices**|(% style="width:229px" %)((( 20 20 **Offset modification** 21 -)))|(% style="width:16 9px" %)(((21 +)))|(% style="width:216px" %)((( 22 22 **Pulse extension** 23 23 ))) 24 -| (% style="width:35px" %)**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|(% style="width:67px" %)**K**|(% style="width:67px" %)**H**|(% style="width:201px" %)**[D]**|(% style="width:169px" %)**XXP**25 -|(% rowspan="2" %)OUT T| (% style="width:130px" %)Parameter 1|(%style="width:35px" %)| | | |●| | | | |(%style="width:67px" %)|(% style="width:67px" %) |(% style="width:201px" %) |(% style="width:169px" %)26 -| (% style="width:130px" %)Parameter 2|(% style="width:35px" %)●|●|●|●| |●|●|●|●|(% style="width:67px" %)●|(% style="width:67px" %)●|(% style="width:201px" %) |(% style="width:169px" %)24 +|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**K**|(% style="width:2px" %)**H**|(% style="width:229px" %)**[D]**|(% style="width:216px" %)**XXP** 25 +|(% rowspan="2" %)OUT T|Parameter 1| | | | |●| | | | | |(% style="width:2px" %) |(% style="width:229px" %) |(% style="width:216px" %) 26 +|Parameter 2|●|●|●|●| |●|●|●|●|●|(% style="width:2px" %)●|(% style="width:229px" %) |(% style="width:216px" %) 27 27 28 28 **Features** 29 29 ... ... @@ -32,10 +32,10 @@ 32 32 When the operation result before the OUT instruction changes from ON to OFF, the situation is as follows. 33 33 34 34 (% class="table-bordered" %) 35 -|(% rowspan="2" style="width:168px"%)**Timer type**|(% rowspan="2"style="width:101px"%)**Timer coil**|(% rowspan="2"style="width:220px"%)**The current value of the timer**|(% colspan="2"style="width:301px"%)**Before the time limit**|(% colspan="2"style="width:286px"%)**After the time limit**36 -| (% style="width:149px" %)**Normally open contact**|(% style="width:151px" %)**Normally closed contact**|(% style="width:141px" %)**Normally open contact**|(% style="width:145px" %)**Normally closed contact**37 -| (% style="width:168px" %)Timer|(% style="width:101px" %)OFF|(% style="width:220px" %)0|(% style="width:149px" %)Non-conductive|(% style="width:151px" %)Conduction|(% style="width:141px" %)Non-conductive|(% style="width:145px" %)Conduction38 -| (% style="width:168px" %)Cumulative timer|(% style="width:101px" %)OFF|(% style="width:220px" %)Keep current value|(% style="width:149px" %)Non-conductive|(% style="width:151px" %)Conduction|(% style="width:141px" %)Conduction|(% style="width:145px" %)Non-conductive35 +|(% rowspan="2" %)**Timer type**|(% rowspan="2" %)**Timer coil**|(% rowspan="2" %)**The current value of the timer**|(% colspan="2" %)**Before the time limit**|(% colspan="2" %)**After the time limit** 36 +|**Normally open contact**|**Normally closed contact**|**Normally open contact**|**Normally closed contact** 37 +|Timer|OFF|0|Non-conductive|Conduction|Non-conductive|Conduction 38 +|Cumulative timer|OFF|Keep current value|Non-conductive|Conduction|Conduction|Non-conductive 39 39 40 40 • After the time limit expires, clear the current value of the accumulative timer and turn off the contact with the RST instruction. 41 41 ... ... @@ -48,11 +48,11 @@ 48 48 • Description of each timer: 49 49 50 50 (% class="table-bordered" %) 51 -| (% style="width:171px" %)**Device number**|(% style="width:516px" %)**Timer specifications**|(% style="width:176px" %)**Device number**|(% style="width:213px" %)**Timer specifications**52 -| (% style="width:171px" %)T0 to T191|(% style="width:516px" %)100ms timer|(% style="width:176px" %)T246 to T249|(% style="width:213px" %)1ms accumulative timer53 -|(% rowspan="2" style="width:171px"%)T192 to T199|(% rowspan="2"style="width:516px"%)100ms subroutine timer (used in the subroutine, even if the subroutine is not called, it will still be updated)|(% style="width:176px" %)T250 to T255|(% style="width:213px" %)10ms cumulative timer54 -| (% style="width:176px" %)T256 to T383|(% style="width:213px" %)1ms timer55 -| (% style="width:171px" %)T200 to T245|(% style="width:516px" %)10ms timer|(% style="width:176px" %)T384 to T511|(% style="width:213px" %)0.1ms timer51 +|**Device number**|**Timer specifications**|**Device number**|**Timer specifications** 52 +|T0 to T191|100ms timer|T246 to T249|1ms accumulative timer 53 +|(% rowspan="2" %)T192 to T199|(% rowspan="2" %)100ms subroutine timer (used in the subroutine, even if the subroutine is not called, it will still be updated)|T250 to T255|10ms cumulative timer 54 +|T256 to T383|1ms timer 55 +|T200 to T245|10ms timer|T384 to T511|0.1ms timer 56 56 57 57 **Error code** 58 58