Changes for page 05 Timer and counter
Last modified by Leo Wei on 2024/12/24 22:38
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PLC Editor2. 2\.1 LX5V user manual.WebHome1 +PLC Editor2.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Stone1 +XWiki.admin - Content
-
... ... @@ -8,22 +8,21 @@ 8 8 9 9 **Content, range and data type** 10 10 11 -(% class="table-bordered" style="width:1200px" %) 12 -|**Parameter**|(% style="width:324px" %)**Content**|(% style="width:197px" %)**Range**|(% style="width:245px" %)**Data type**|(% style="width:283px" %)**Data type (label)** 13 -|(d)|(% style="width:324px" %)Timer device number|(% style="width:197px" %)-|(% style="width:245px" %)Counter|(% style="width:283px" %)ANY 14 -|(value)|(% style="width:324px" %)Timer setting value|(% style="width:197px" %)0 to 32767|(% style="width:245px" %)Unsigned BIN 16 bit|(% style="width:283px" %)ANY16 11 +|Parameter|Content|Range|Data type|Data type (label) 12 +|(d)|Timer device number|-|Counter|ANY 13 +|(value)|Timer setting value|0 to 32767|Unsigned BIN 16 bit|ANY16 15 15 16 16 **Device used** 17 17 18 - (% class="table-bordered" style="width:1111px" %)19 -|(% rowspan="2" %) **Instruction**|(% rowspan="2"style="width:130px"%)**Parameter**|(% colspan="11"style="width:486px"%)**Devices**|(% style="width:201px" %)(((20 - **Offset modification**21 -)))|( % style="width:169px" %)(((22 - **Pulse extension**17 + 18 +|(% rowspan="2" %)Instruction|(% rowspan="2" %)Parameter|(% colspan="11" %)Devices|((( 19 +Offset modification 20 +)))|((( 21 +Pulse extension 23 23 ))) 24 -| (% style="width:35px" %)**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|(% style="width:67px" %)**K**|(% style="width:67px" %)**H**|(% style="width:201px" %)**[D]**|(% style="width:169px" %)**XXP**25 -|(% rowspan="2" %)OUT T| (% style="width:130px" %)Parameter 1|(%style="width:35px" %)| | | |●| | | | |(%style="width:67px" %)|(%style="width:67px" %)|(%style="width:201px" %)|(%style="width:169px" %)26 -| (% style="width:130px" %)Parameter 2|(% style="width:35px" %)●|●|●|●| |●|●|●|●|(% style="width:67px" %)●|(% style="width:67px" %)●|(%style="width:201px" %)|(%style="width:169px" %)23 +|KnX|KnY|KnM|KnS|T|C|D|R|SD|K|H|[D]|XXP 24 +|(% rowspan="2" %)OUT T|Parameter 1| | | | |●| | | | | | | | 25 +|Parameter 2|●|●|●|●| |●|●|●|●|●|●| | 27 27 28 28 **Features** 29 29 ... ... @@ -31,12 +31,12 @@ 31 31 32 32 When the operation result before the OUT instruction changes from ON to OFF, the situation is as follows. 33 33 34 -(% class="table-bordered" %) 35 -|(% rowspan="2" style="width:168px" %)**Timer type**|(% rowspan="2" style="width:101px" %)**Timer coil**|(% rowspan="2" style="width:220px" %)**The current value of the timer**|(% colspan="2" style="width:301px" %)**Before the time limit**|(% colspan="2" style="width:286px" %)**After the time limit** 36 -|(% style="width:149px" %)**Normally open contact**|(% style="width:151px" %)**Normally closed contact**|(% style="width:141px" %)**Normally open contact**|(% style="width:145px" %)**Normally closed contact** 37 -|(% style="width:168px" %)Timer|(% style="width:101px" %)OFF|(% style="width:220px" %)0|(% style="width:149px" %)Non-conductive|(% style="width:151px" %)Conduction|(% style="width:141px" %)Non-conductive|(% style="width:145px" %)Conduction 38 -|(% style="width:168px" %)Cumulative timer|(% style="width:101px" %)OFF|(% style="width:220px" %)Keep current value|(% style="width:149px" %)Non-conductive|(% style="width:151px" %)Conduction|(% style="width:141px" %)Conduction|(% style="width:145px" %)Non-conductive 39 39 34 +|(% rowspan="2" %)Timer type|(% rowspan="2" %)Timer coil|(% rowspan="2" %)The current value of the timer|(% colspan="2" %)Before the time limit|(% colspan="2" %)After the time limit 35 +|Normally open contact|Normally closed contact|Normally open contact|Normally closed contact 36 +|Timer|OFF|0|Non-conductive|Conduction|Non-conductive|Conduction 37 +|Cumulative timer|OFF|Keep current value|Non-conductive|Conduction|Conduction|Non-conductive 38 + 40 40 • After the time limit expires, clear the current value of the accumulative timer and turn off the contact with the RST instruction. 41 41 42 42 • When the setting value is 0, the time limit will expire when the OUT instruction is executed. ... ... @@ -47,17 +47,17 @@ 47 47 48 48 • Description of each timer: 49 49 50 -(% class="table-bordered" %) 51 -|(% style="width:171px" %)**Device number**|(% style="width:516px" %)**Timer specifications**|(% style="width:176px" %)**Device number**|(% style="width:213px" %)**Timer specifications** 52 -|(% style="width:171px" %)T0 to T191|(% style="width:516px" %)100ms timer|(% style="width:176px" %)T246 to T249|(% style="width:213px" %)1ms accumulative timer 53 -|(% rowspan="2" style="width:171px" %)T192 to T199|(% rowspan="2" style="width:516px" %)100ms subroutine timer (used in the subroutine, even if the subroutine is not called, it will still be updated)|(% style="width:176px" %)T250 to T255|(% style="width:213px" %)10ms cumulative timer 54 -|(% style="width:176px" %)T256 to T383|(% style="width:213px" %)1ms timer 55 -|(% style="width:171px" %)T200 to T245|(% style="width:516px" %)10ms timer|(% style="width:176px" %)T384 to T511|(% style="width:213px" %)0.1ms timer 56 56 50 +|Device number|Timer specifications|Device number|Timer specifications 51 +|T0 to T191|100ms timer|T246 to T249|1ms accumulative timer 52 +|(% rowspan="2" %)T192 to T199|(% rowspan="2" %)100ms subroutine timer (used in the subroutine, even if the subroutine is not called, it will still be updated)|T250 to T255|10ms cumulative timer 53 +|T256 to T383|1ms timer 54 +|T200 to T245|10ms timer|T384 to T511|0.1ms timer 55 + 57 57 **Error code** 58 58 59 - (% class="table-bordered" %)60 -| **Error code**|**Content**58 + 59 +|Error code|Content 61 61 |4084H|The parameter setting in (value) is out of range 62 62 63 63 **Example** ... ... @@ -77,24 +77,24 @@ 77 77 78 78 **Content, range and data type** 79 79 80 - (% class="table-bordered" %)81 -| **Parameter**|**Content**|**Range**|**Data type**|**Data type (label)**79 + 80 +|Parameter|Content|Range|Data type|Data type (label) 82 82 |(d)|Counter device number|-|Counter|ANY 83 83 |(value)|Counter setting value|0 to 32767|Unsigned BIN 16 bit|ANY_INT 84 84 85 85 **Device used** 86 86 87 -(% class="table-bordered" %) 88 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="12" %)**Devices**|((( 89 -**Offset** 90 90 91 -**modification** 87 +|(% rowspan="2" %)Instruction|(% rowspan="2" %)Parameter|(% colspan="12" %)Devices|((( 88 +Offset 89 + 90 +modification 92 92 )))|((( 93 - **Pulse**92 +Pulse 94 94 95 - **extension**94 +extension 96 96 ))) 97 -| **KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**K**|**H**|**E**|**[D]**|**XXP**96 +|KnX|KnY|KnM|KnS|T|C|D|R|SD|K|H|E|[D]|XXP 98 98 |(% rowspan="2" %)OUT C|Parameter 1| | | | | |●| | | | | | | | 99 99 |Parameter 2|●|●|●|●|●| |●|●|●|●|●|●| | 100 100 ... ... @@ -110,8 +110,8 @@ 110 110 111 111 **Error code** 112 112 113 - (% class="table-bordered" %)114 -| **Error code**|**Content**112 + 113 +|Error code|Content 115 115 |4084H|The parameter setting in (value) is out of range 116 116 |4085H|The (value) parameter exceeds the device range 117 117 ... ... @@ -132,24 +132,22 @@ 132 132 133 133 **Content, range and data type** 134 134 135 -(% class="table-bordered" %) 136 -|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 134 +|Parameter|Content|Range|Data type|Data type (label) 137 137 |(d)|Long counter device number|-|Counter|ANY 138 138 |(value)|Long counter setting value|0 to 4294967295|Unsigned BIN 32 bit|ANY_INT 139 139 140 140 **Device used** 141 141 142 -(% class="table-bordered" %) 143 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="12" %)**Devices**|((( 144 -**Offset** 140 +|(% rowspan="2" %)Instruction|(% rowspan="2" %)Parameter|(% colspan="12" %)Devices|((( 141 +Offset 145 145 146 - **modification**143 +modification 147 147 )))|((( 148 - **Pulse**145 +Pulse 149 149 150 - **extension**147 +extension 151 151 ))) 152 -| **KnX**|**KnY**|**KnM**|**KnS**|**T**|**D**|**R**|**SD**|**LC**|**K**|**H**|**E**|**[D]**|**XXP**149 +|KnX|KnY|KnM|KnS|T|D|R|SD|LC|K|H|E|[D]|XXP 153 153 |(% rowspan="2" %)OUT LC|Parameter 1| | | | | | | | |●| | | | | 154 154 |Parameter 2|●|●|●|●|●|●|●|●| |●|●|●| | 155 155 ... ... @@ -165,8 +165,8 @@ 165 165 166 166 **Error code** 167 167 168 - (% class="table-bordered" %)169 -| **Error code**|**Content**165 + 166 +|Error code|Content 170 170 |4085H|The (value) parameter exceeds the device range 171 171 172 172 **Example**