Changes for page 05 Timer and counter
Last modified by Leo Wei on 2024/12/24 22:38
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,14 +16,14 @@ 16 16 **Device used** 17 17 18 18 19 -|(% rowspan="2" %) **Instruction**|(% rowspan="2"style="width:130px"%)**Parameter**|(% colspan="11"style="width:486px"%)**Devices**|(% style="width:201px" %)(((20 - **Offset modification**21 -)))|( % style="width:169px" %)(((22 - **Pulse extension**19 +|(% rowspan="2" %)Instruction|(% rowspan="2" %)Parameter|(% colspan="11" %)Devices|((( 20 +Offset modification 21 +)))|((( 22 +Pulse extension 23 23 ))) 24 -| (% style="width:35px" %)**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|(% style="width:67px" %)**K**|(% style="width:67px" %)**H**|(% style="width:201px" %)**[D]**|(% style="width:169px" %)**XXP**25 -|(% rowspan="2" %)OUT T| (% style="width:130px" %)Parameter 1|(%style="width:35px" %)| | | |●| | | | |(%style="width:67px" %)|(%style="width:67px" %)|(%style="width:201px" %)|(%style="width:169px" %)26 -| (% style="width:130px" %)Parameter 2|(% style="width:35px" %)●|●|●|●| |●|●|●|●|(% style="width:67px" %)●|(% style="width:67px" %)●|(%style="width:201px" %)|(%style="width:169px" %)24 +|KnX|KnY|KnM|KnS|T|C|D|R|SD|K|H|[D]|XXP 25 +|(% rowspan="2" %)OUT T|Parameter 1| | | | |●| | | | | | | | 26 +|Parameter 2|●|●|●|●| |●|●|●|●|●|●| | 27 27 28 28 **Features** 29 29 ... ... @@ -32,10 +32,10 @@ 32 32 When the operation result before the OUT instruction changes from ON to OFF, the situation is as follows. 33 33 34 34 35 -|(% rowspan="2" style="width:168px"%)**Timer type**|(% rowspan="2"style="width:101px"%)**Timer coil**|(% rowspan="2"style="width:220px"%)**The current value of the timer**|(% colspan="2"style="width:301px"%)**Before the time limit**|(% colspan="2"style="width:286px"%)**After the time limit**36 -| (% style="width:149px" %)**Normally open contact**|(% style="width:151px" %)**Normally closed contact**|(% style="width:141px" %)**Normally open contact**|(% style="width:145px" %)**Normally closed contact**37 -| (% style="width:168px" %)Timer|(% style="width:101px" %)OFF|(% style="width:220px" %)0|(% style="width:149px" %)Non-conductive|(% style="width:151px" %)Conduction|(% style="width:141px" %)Non-conductive|(% style="width:145px" %)Conduction38 -| (% style="width:168px" %)Cumulative timer|(% style="width:101px" %)OFF|(% style="width:220px" %)Keep current value|(% style="width:149px" %)Non-conductive|(% style="width:151px" %)Conduction|(% style="width:141px" %)Conduction|(% style="width:145px" %)Non-conductive35 +|(% rowspan="2" %)Timer type|(% rowspan="2" %)Timer coil|(% rowspan="2" %)The current value of the timer|(% colspan="2" %)Before the time limit|(% colspan="2" %)After the time limit 36 +|Normally open contact|Normally closed contact|Normally open contact|Normally closed contact 37 +|Timer|OFF|0|Non-conductive|Conduction|Non-conductive|Conduction 38 +|Cumulative timer|OFF|Keep current value|Non-conductive|Conduction|Conduction|Non-conductive 39 39 40 40 • After the time limit expires, clear the current value of the accumulative timer and turn off the contact with the RST instruction. 41 41