Changes for page 05 Timer and counter

Last modified by Leo Wei on 2024/12/24 22:38

From version 5.1
edited by Leo Wei
on 2024/12/24 22:37
Change comment: There is no comment for this version
To version 4.7
edited by Leo Wei
on 2024/12/24 22:36
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -16,14 +16,14 @@
16 16  **Device used**
17 17  
18 18  
19 -|(% rowspan="2" %)Instruction|(% rowspan="2" %)Parameter|(% colspan="11" %)Devices|(((
20 -Offset modification
21 -)))|(((
22 -Pulse extension
19 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" style="width:130px" %)**Parameter**|(% colspan="11" style="width:486px" %)**Devices**|(% style="width:201px" %)(((
20 +**Offset modification**
21 +)))|(% style="width:169px" %)(((
22 +**Pulse extension**
23 23  )))
24 -|KnX|KnY|KnM|KnS|T|C|D|R|SD|K|H|[D]|XXP
25 -|(% rowspan="2" %)OUT T|Parameter 1| | | | |●| | | | | | | |
26 -|Parameter 2|●|●|●|●| |●|●|●|●|●|●| |
24 +|(% style="width:35px" %)**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|(% style="width:67px" %)**K**|(% style="width:67px" %)**H**|(% style="width:201px" %)**[D]**|(% style="width:169px" %)**XXP**
25 +|(% rowspan="2" %)OUT T|(% style="width:130px" %)Parameter 1|(% style="width:35px" %) | | | |●| | | | |(% style="width:67px" %) |(% style="width:67px" %) |(% style="width:201px" %) |(% style="width:169px" %)
26 +|(% style="width:130px" %)Parameter 2|(% style="width:35px" %)●|●|●|●| |●|●|●|●|(% style="width:67px" %)●|(% style="width:67px" %)●|(% style="width:201px" %) |(% style="width:169px" %)
27 27  
28 28  **Features**
29 29  
... ... @@ -32,10 +32,10 @@
32 32  When the operation result before the OUT instruction changes from ON to OFF, the situation is as follows.
33 33  
34 34  
35 -|(% rowspan="2" %)Timer type|(% rowspan="2" %)Timer coil|(% rowspan="2" %)The current value of the timer|(% colspan="2" %)Before the time limit|(% colspan="2" %)After the time limit
36 -|Normally open contact|Normally closed contact|Normally open contact|Normally closed contact
37 -|Timer|OFF|0|Non-conductive|Conduction|Non-conductive|Conduction
38 -|Cumulative timer|OFF|Keep current value|Non-conductive|Conduction|Conduction|Non-conductive
35 +|(% rowspan="2" style="width:168px" %)**Timer type**|(% rowspan="2" style="width:101px" %)**Timer coil**|(% rowspan="2" style="width:220px" %)**The current value of the timer**|(% colspan="2" style="width:301px" %)**Before the time limit**|(% colspan="2" style="width:286px" %)**After the time limit**
36 +|(% style="width:149px" %)**Normally open contact**|(% style="width:151px" %)**Normally closed contact**|(% style="width:141px" %)**Normally open contact**|(% style="width:145px" %)**Normally closed contact**
37 +|(% style="width:168px" %)Timer|(% style="width:101px" %)OFF|(% style="width:220px" %)0|(% style="width:149px" %)Non-conductive|(% style="width:151px" %)Conduction|(% style="width:141px" %)Non-conductive|(% style="width:145px" %)Conduction
38 +|(% style="width:168px" %)Cumulative timer|(% style="width:101px" %)OFF|(% style="width:220px" %)Keep current value|(% style="width:149px" %)Non-conductive|(% style="width:151px" %)Conduction|(% style="width:141px" %)Conduction|(% style="width:145px" %)Non-conductive
39 39  
40 40  • After the time limit expires, clear the current value of the accumulative timer and turn off the contact with the RST instruction.
41 41