Changes for page 05 Timer and counter
Last modified by Leo Wei on 2024/12/24 22:38
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,6 +8,7 @@ 8 8 9 9 **Content, range and data type** 10 10 11 + 11 11 |Parameter|Content|Range|Data type|Data type (label) 12 12 |(d)|Timer device number|-|Counter|ANY 13 13 |(value)|Timer setting value|0 to 32767|Unsigned BIN 16 bit|ANY16 ... ... @@ -15,14 +15,14 @@ 15 15 **Device used** 16 16 17 17 18 -|(% rowspan="2" %)Instruction|(% rowspan="2" %)Parameter|(% colspan="11" %)Devices|((( 19 -Offset modification 20 -)))|((( 21 -Pulse extension 19 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" style="width:130px" %)**Parameter**|(% colspan="11" style="width:486px" %)**Devices**|(% style="width:201px" %)((( 20 +**Offset modification** 21 +)))|(% style="width:169px" %)((( 22 +**Pulse extension** 22 22 ))) 23 -|KnX|KnY|KnM|KnS|T|C|D|R|SD|K|H|[D]|XXP 24 -|(% rowspan="2" %)OUT T|Parameter 1| | | | |●| | | | | | | | 25 -|Parameter 2|●|●|●|●| |●|●|●|●|●|●| | 24 +|(% style="width:35px" %)**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|(% style="width:67px" %)**K**|(% style="width:67px" %)**H**|(% style="width:201px" %)**[D]**|(% style="width:169px" %)**XXP** 25 +|(% rowspan="2" %)OUT T|(% style="width:130px" %)Parameter 1|(% style="width:35px" %) | | | |●| | | | |(% style="width:67px" %) |(% style="width:67px" %) |(% style="width:201px" %) |(% style="width:169px" %) 26 +|(% style="width:130px" %)Parameter 2|(% style="width:35px" %)●|●|●|●| |●|●|●|●|(% style="width:67px" %)●|(% style="width:67px" %)●|(% style="width:201px" %) |(% style="width:169px" %) 26 26 27 27 **Features** 28 28 ... ... @@ -31,10 +31,10 @@ 31 31 When the operation result before the OUT instruction changes from ON to OFF, the situation is as follows. 32 32 33 33 34 -|(% rowspan="2" %)Timer type|(% rowspan="2" %)Timer coil|(% rowspan="2" %)The current value of the timer|(% colspan="2" %)Before the time limit|(% colspan="2" %)After the time limit 35 -|Normally open contact|Normally closed contact|Normally open contact|Normally closed contact 36 -|Timer|OFF|0|Non-conductive|Conduction|Non-conductive|Conduction 37 -|Cumulative timer|OFF|Keep current value|Non-conductive|Conduction|Conduction|Non-conductive 35 +|(% rowspan="2" style="width:168px" %)**Timer type**|(% rowspan="2" style="width:101px" %)**Timer coil**|(% rowspan="2" style="width:220px" %)**The current value of the timer**|(% colspan="2" style="width:301px" %)**Before the time limit**|(% colspan="2" style="width:286px" %)**After the time limit** 36 +|(% style="width:149px" %)**Normally open contact**|(% style="width:151px" %)**Normally closed contact**|(% style="width:141px" %)**Normally open contact**|(% style="width:145px" %)**Normally closed contact** 37 +|(% style="width:168px" %)Timer|(% style="width:101px" %)OFF|(% style="width:220px" %)0|(% style="width:149px" %)Non-conductive|(% style="width:151px" %)Conduction|(% style="width:141px" %)Non-conductive|(% style="width:145px" %)Conduction 38 +|(% style="width:168px" %)Cumulative timer|(% style="width:101px" %)OFF|(% style="width:220px" %)Keep current value|(% style="width:149px" %)Non-conductive|(% style="width:151px" %)Conduction|(% style="width:141px" %)Conduction|(% style="width:145px" %)Non-conductive 38 38 39 39 • After the time limit expires, clear the current value of the accumulative timer and turn off the contact with the RST instruction. 40 40