Changes for page 01 Transfer and comparison
Last modified by Mora Zhou on 2023/11/22 16:08
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PLC Editor2. 1 User manual.2\.1 LX5V user manual.07 Basic instructions.WebHome1 +PLC Editor2.07 Basic instructions.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.a dmin1 +XWiki.Mora - Content
-
... ... @@ -49,18 +49,16 @@ 49 49 50 50 **Content, range and data type** 51 51 52 -|Parameter|Content|Range|Data type|Data type (label) 53 -|(S)|Transmit source data or the device number stored data|-2147483648 to 2147483647|Signed BIN32|ANY32_S 54 -|(D)|Transmit destination device number|-|Signed BIN32|ANY32_S 52 +|=(% scope="row" %)Parameter|=Content|=Range|=Data type|=Data type (label) 53 +|=(S)|Transmit source data or the device number stored data|-2147483648 to 2147483647|Signed BIN32|ANY32_S 54 +|=(D)|Transmit destination device number|-|Signed BIN32|ANY32_S 55 55 56 56 **Device used** 57 57 58 -|(% rowspan="2" style="text-align:center; vertical-align:middle" %)**Instruction**|(% rowspan="2" style="text-align:center; vertical-align:middle" %)**Parameter**|(% colspan="13" style="text-align:center; vertical-align:middle" %)**Devices**|Offset modification|((( 59 -**Pulse extension** 60 -))) 58 +|=(% rowspan="2" scope="row" %)Instruction|=(% rowspan="2" %)Parameter|=(% colspan="13" %)Devices|=Offset modification|=Pulse extension 61 61 |KnX|KnY|KnM|KnS|T|C|D|R|SD|LC|HSC|K|H|[D]|XXP 62 -|(% rowspan="2" style="text-align:center; vertical-align:middle"%)DMOV|Parameter 1|●|●|●|●|●|●|●|●|●| | |●|●|●|●63 -|Parameter 2| |●|●|●|●|●|●|●|●|●|●| | |●|● 60 +|=(% rowspan="2" %)DMOV|=Parameter 1|●|●|●|●|●|●|●|●|●| | |●|●|●|● 61 +|=Parameter 2| |●|●|●|●|●|●|●|●|●|●| | |●|● 64 64 65 65 **Features** 66 66 ... ... @@ -432,7 +432,7 @@ 432 432 433 433 **Device used** 434 434 435 -|(% rowspan="2" style="text-align:center; vertical-align:middle" %)**Instruction**|(% rowspan="2" style="text-align:center; vertical-align:middle" %)**Parameter**|(% colspan="16" style="text-align:center; vertical-align:middle" %)**Devices**|Offset modification|((( 433 +|(% rowspan="2" style="text-align:center; vertical-align:middle" %)**Instruction**|(% rowspan="2" style="text-align:center; vertical-align:middle" %)**Parameter**|(% colspan="16" style="text-align:center; vertical-align:middle" %)**Devices**|**Offset modification**|((( 436 436 **Pulse extension** 437 437 ))) 438 438 |Y|M|S|SM|D.b|KnX|KnY|KnM|KnS|T|C|D|R|SD|K|H|[D]|XXP ... ... @@ -453,7 +453,10 @@ 453 453 454 454 (1): Even if the instruction input is OFF and the CMP instruction is not executed, (D) to (D)+2 will keep the state before the instruction input changed from ON to OFF. 455 455 454 +(% class="box infomessage" %) 455 +((( 456 456 ✎**Note: **Occupy the device specified in 3 points (D) at the beginning, please be careful not to overlap with the device used for other control. 457 +))) 457 457 458 458 **Error code** 459 459 ... ... @@ -510,7 +510,10 @@ 510 510 511 511 (1): Even if the instruction input is OFF, the DCMP instruction is not executed, (D) to (D)+2 will keep the state before the instruction input changed from ON to OFF. 512 512 514 +(% class="box infomessage" %) 515 +((( 513 513 ✎**Note: ** Occupy the device specified in 3 points (D) at the beginning. Please be careful not to overlap with other control devices. 517 +))) 514 514 515 515 **Error code** 516 516 ... ... @@ -566,7 +566,10 @@ 566 566 567 567 [[image:07-1 Basic instructions_html_c0cea7cfb5b2e83c.png]] 568 568 573 +(% class="box infomessage" %) 574 +((( 569 569 ✎**Note: **If continuous execution instructions are used, conversion will be performed every operation cycle. 576 +))) 570 570 571 571 **Error code** 572 572