Changes for page 01 Transfer and comparison
Last modified by Mora Zhou on 2023/11/22 16:08
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Mora1 +XWiki.admin - Content
-
... ... @@ -430,7 +430,7 @@ 430 430 431 431 **Device used** 432 432 433 -|(% rowspan="2" style="text-align:center; vertical-align:middle" %)**Instruction**|(% rowspan="2" style="text-align:center; vertical-align:middle" %)**Parameter**|(% colspan="16" style="text-align:center; vertical-align:middle" %)**Devices**| **Offset modification**|(((433 +|(% rowspan="2" style="text-align:center; vertical-align:middle" %)**Instruction**|(% rowspan="2" style="text-align:center; vertical-align:middle" %)**Parameter**|(% colspan="16" style="text-align:center; vertical-align:middle" %)**Devices**|Offset modification|((( 434 434 **Pulse extension** 435 435 ))) 436 436 |Y|M|S|SM|D.b|KnX|KnY|KnM|KnS|T|C|D|R|SD|K|H|[D]|XXP ... ... @@ -451,10 +451,7 @@ 451 451 452 452 (1): Even if the instruction input is OFF and the CMP instruction is not executed, (D) to (D)+2 will keep the state before the instruction input changed from ON to OFF. 453 453 454 -(% class="box infomessage" %) 455 -((( 456 456 ✎**Note: **Occupy the device specified in 3 points (D) at the beginning, please be careful not to overlap with the device used for other control. 457 -))) 458 458 459 459 **Error code** 460 460 ... ... @@ -511,10 +511,7 @@ 511 511 512 512 (1): Even if the instruction input is OFF, the DCMP instruction is not executed, (D) to (D)+2 will keep the state before the instruction input changed from ON to OFF. 513 513 514 -(% class="box infomessage" %) 515 -((( 516 516 ✎**Note: ** Occupy the device specified in 3 points (D) at the beginning. Please be careful not to overlap with other control devices. 517 -))) 518 518 519 519 **Error code** 520 520 ... ... @@ -570,10 +570,7 @@ 570 570 571 571 [[image:07-1 Basic instructions_html_c0cea7cfb5b2e83c.png]] 572 572 573 -(% class="box infomessage" %) 574 -((( 575 575 ✎**Note: **If continuous execution instructions are used, conversion will be performed every operation cycle. 576 -))) 577 577 578 578 **Error code** 579 579 ... ... @@ -753,8 +753,6 @@ 753 753 754 754 (1): Even if the instruction input is OFF and the ZCP instruction is not executed, (D) to (D)+2 will keep the state before the instruction input turns from ON to OFF. 755 755 756 -(% class="box infomessage" %) 757 -((( 758 758 ✎**Note: ** 759 759 760 760 • Please set the lower comparison value (S1) to a value smaller than the upper comparison value (S2). ... ... @@ -762,7 +762,6 @@ 762 762 • When (S1) is greater than (S2), it will be processed as (S2)=(S1). 763 763 764 764 • The device specified in 3 points (D) is occupied at the beginning. Please be careful not to overlap with other control devices. 765 -))) 766 766 767 767 **Error code** 768 768