Changes for page 12 Clock operation
Last modified by Mora Zhou on 2023/11/21 17:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1722,16 +1722,14 @@ 1722 1722 1723 1723 **Device used** 1724 1724 1725 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="12" %)**Devices**|**Offset modification**|((( 1726 -**Pulse** 1727 - 1728 -**extension** 1725 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="11" %)**Devices**|**Offset modification**|((( 1726 +**Pulse extension** 1729 1729 ))) 1730 -|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**K**|**H**|** E**|**[D]**|**XXP**1731 -|(% rowspan="4" %)LIMIT|Parameter 1|●|●|●|●|●|●|●|●|●|●|●| |●|●1732 -|Parameter 2|●|●|●|●|●|●|●|●|●|●|●| |●|●1733 -|Parameter 3|●|●|●|●|●|●|●|●|●| | | |●|●1734 -|Parameter 4| |●|●|●|●|●|●|●|●| | | |●|●1728 +|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**K**|**H**|**[D]**|**XXP** 1729 +|(% rowspan="4" %)LIMIT|Parameter 1|●|●|●|●|●|●|●|●|●|●|●|●|● 1730 +|Parameter 2|●|●|●|●|●|●|●|●|●|●|●|●|● 1731 +|Parameter 3|●|●|●|●|●|●|●|●|●| | |●|● 1732 +|Parameter 4| |●|●|●|●|●|●|●|●| | |●|● 1735 1735 1736 1736 **Features** 1737 1737 ... ... @@ -1742,13 +1742,13 @@ 1742 1742 |High limit value (s1) <input value (s3)|High limit value (s2) 1743 1743 |Low limit value (s1) ≤ input value (s3) ≤ high limit value (s2)|Input value (s3) 1744 1744 1745 - 1746 1746 ((( 1747 -•Only in the case of controlling high limit value, set the minimum value of data range in the low limit value specified in (s1). 1744 +• Only in the case of controlling high limit value, set the minimum value of data range in the low limit value specified in (s1). 1748 1748 1749 1749 • Only in the case of controlling low limit value, set the maximum value of data range in the high limit value specified in (s2). 1750 1750 1751 -[[image:07-5 Basic instructions_html_50eb5229b027aa14.png]] 1748 +(% style="text-align:center" %) 1749 +[[image:07-5 Basic instructions_html_50eb5229b027aa14.png||height="297" width="550"]] 1752 1752 ))) 1753 1753 1754 1754 **Error code** ... ... @@ -1760,6 +1760,7 @@ 1760 1760 1761 1761 **Example** 1762 1762 1761 +(% style="text-align:center" %) 1763 1763 [[image:07-5 Basic instructions_html_d67a2e740d4fc738.png]] 1764 1764 1765 1765 When X000 is ON ... ... @@ -1770,9 +1770,9 @@ 1770 1770 1771 1771 • When 5,000 <D0, D1 is 5,000. 1772 1772 1773 - {{id name="_Toc32553"/}}{{id name="_Toc9981"/}}{{idname="_Toc9158"/}}**DLIMIT/BIN 32-bit data high and low limit control**1772 +== **DLIMIT/BIN 32-bit data high and low limit control** == 1774 1774 1775 - [[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]]**DLIMIT(P)**1774 +**DLIMIT(P)** 1776 1776 1777 1777 The input value (BIN 32-bit value) specified in (s3) controls the output value stored in the device specified in (d) according to the range of high and low limit values specified in (s1) and (s2). 1778 1778 ... ... @@ -1788,16 +1788,14 @@ 1788 1788 1789 1789 **Device used** 1790 1790 1791 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 1792 -**Pulse** 1793 - 1794 -**extension** 1790 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="13" %)**Devices**|**Offset modification**|((( 1791 +**Pulse extension** 1795 1795 ))) 1796 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**1797 -|(% rowspan="4" %)DLIMIT|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●||●|●1798 -|Parameter 2| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●||●|●1799 -|Parameter 3| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●| | ||●|●1800 -|Parameter 4| | | | | | | | | | | |●|●|●|●|●|●|●|●|●|●| | ||●|●1793 +|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**[D]**|**XXP** 1794 +|(% rowspan="4" %)DLIMIT|Parameter 1|●|●|●|●|●|●|●|●|●|●|●|●|●|●|● 1795 +|Parameter 2|●|●|●|●|●|●|●|●|●|●|●|●|●|●|● 1796 +|Parameter 3|●|●|●|●|●|●|●|●|●|●|●| | |●|● 1797 +|Parameter 4| |●|●|●|●|●|●|●|●|●|●| | |●|● 1801 1801 1802 1802 **Features** 1803 1803 ... ... @@ -1808,7 +1808,7 @@ 1808 1808 |High limit value ((s2), (s2)+1) <input value ((s3), (s3)+1)|High limit value ((s2), (s2)+1) 1809 1809 |Low limit value ((s1), (s1)+1) ≤ input value ((s3), (s3)+1) ≤ high limit value ((s2), (s2)+1)|Input value ((s3), (s3)+1) 1810 1810 1811 - {{idname="OLE_LINK43"/}}{{idname="OLE_LINK40"/}}•Only in the case of controlling high limit value, set the minimum value of data range in the low limit value specified in (s1).1808 +• Only in the case of controlling high limit value, set the minimum value of data range in the low limit value specified in (s1). 1812 1812 1813 1813 • Only in the case of controlling low limit value, set the maximum value of data range in the high limit value specified in (s2). 1814 1814 ... ... @@ -1821,7 +1821,8 @@ 1821 1821 1822 1822 **Example** 1823 1823 1824 -[[image:07-5 Basic instructions_html_217355b90f4b4e16.png]] 1821 +(% style="text-align:center" %) 1822 +[[image:07-5 Basic instructions_html_217355b90f4b4e16.png||height="53" width="400"]] 1825 1825 1826 1826 Operation: 1827 1827 ... ... @@ -1831,9 +1831,9 @@ 1831 1831 1832 1832 • When 1,000,000 <(D1, D0), (D11, D10) is 1,000,000. 1833 1833 1834 - {{id name="_Toc12534"/}}{{id name="_Toc28213"/}}{{idname="_Toc24591"/}}**SCL/BIN 16-bit unit scale (coordinate data of each point)**1832 +== **SCL/BIN 16-bit unit scale (coordinate data of each point)** == 1835 1835 1836 - [[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]]**SCL(P)**1834 +**SCL(P)** 1837 1837 1838 1838 The scaling conversion data (16-bit data unit) specified in (s2) is scaled from the input value specified in (s1), and the calculation result is stored in the device specified in (d). 1839 1839 ... ... @@ -1848,15 +1848,13 @@ 1848 1848 1849 1849 **Device used** 1850 1850 1851 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 1852 -**Pulse** 1853 - 1854 -**extension** 1849 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="11" %)**Devices**|**Offset modification**|((( 1850 +**Pulse extension** 1855 1855 ))) 1856 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**1857 -|(% rowspan="3" %)SCL|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|| |●|●||●|●1858 -|Parameter 2| | | | | | | | | | | | | | | | |●|●|●| | || | |●|●1859 -|Parameter 3| | | | | | | | | | | |●|●|●|●|●|●|●|●| | || | |●|●1852 +|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**K**|**H**|**[D]**|**XXP** 1853 +|(% rowspan="3" %)SCL|Parameter 1|●|●|●|●|●|●|●|●|●|●|●|●|● 1854 +|Parameter 2| | | | | | |●|●|●| | |●|● 1855 +|Parameter 3| |●|●|●|●|●|●|●|●| | |●|● 1860 1860 1861 1861 **Features** 1862 1862 ... ... @@ -1872,7 +1872,8 @@ 1872 1872 |(% rowspan="2" %)Point n|X coordinate|(s2)+2n-1 1873 1873 |Y coordinate|(s2)+2n 1874 1874 1875 -[[image:07-5 Basic instructions_html_80185ccddb878234.png]] 1871 +(% style="text-align:center" %) 1872 +[[image:07-5 Basic instructions_html_80185ccddb878234.png||height="422" width="750"]] 1876 1876 1877 1877 • If the operation result is not an integer value, round the first digit below the decimal point. 1878 1878 ... ... @@ -1888,10 +1888,13 @@ 1888 1888 1889 1889 In the case of scaling conversion characteristics as shown in the figure below, set it as the following data sheet. 1890 1890 1891 -[[image:07-5 Basic instructions_html_74fd22d845ad450e.png]] 1888 +(% style="text-align:center" %) 1889 +[[image:07-5 Basic instructions_html_74fd22d845ad450e.png||height="210" width="750"]] 1892 1892 1893 -|(% colspan="2" rowspan="2" %)**Set items**|(% colspan="3" %)**Sett device and content**|(% rowspan="2" %)**Remarks** 1894 -|(% colspan="2" %)**When R0 is specified in (s2)**|**Set content** 1891 +|(% colspan="2" rowspan="2" %)((( 1892 +**Set items** 1893 +)))|(% colspan="3" %)**Sett device and content**|(% rowspan="2" %)**Remarks** 1894 +|(% colspan="2" %)**When R0 is specified in (s2)**|**Set content** 1895 1895 |(% colspan="2" %)Coordinate points|(s2)|R0|K10| 1896 1896 |(% rowspan="2" %)Point 1|X coordinate|(s2)+1|R1|K5| 1897 1897 |Y coordinate|(s2)+2|R2|K20| ... ... @@ -1939,6 +1939,7 @@ 1939 1939 1940 1940 **Example** 1941 1941 1942 +(% style="text-align:center" %) 1942 1942 [[image:07-5 Basic instructions_html_5519d7b41f15b6d6.png]] 1943 1943 1944 1944 [[image:07-5 Basic instructions_html_ace075fb7675de8e.gif]] When -100 ≤ D0(X) < 0, D100(Y)=