Changes for page 12 Clock operation
Last modified by Mora Zhou on 2023/11/21 17:27
Summary
-
Page properties (4 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,0 +1,1 @@ 1 +12 Clock operation instruction - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PLC Editor2.1 User manual.2\.1 LX5V user manual.WebHome 1 +PLC Editor2.1 User manual.2\.1 LX5V user manual.07.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.J oey1 +XWiki.Jim - Content
-
... ... @@ -1,390 +1,5 @@ 1 -= ** Contactcomparisoninstruction** =1 +== **TADD/The addition of clock data** == 2 2 3 -== **Signed 16-bit contact comparison instruction** == 4 - 5 -**LD £, AND £, OR £** 6 - 7 -The BIN 16-bit data of the device specified in (s1) and the BIN 16-bit data of the device specified in (s2) are compared by normal open contact processing. 8 - 9 -LD£: Normally open contact comparison instruction 10 - 11 -AND£: Normally open contact series connection comparison instruction 12 - 13 -OR£: Normally open contact parallel connection comparison instruction 14 - 15 -**Ladder diagram** 16 - 17 -(% style="text-align:center" %) 18 -[[image:07-5 Basic instructions_html_63210db6b7e1512f.png]] 19 - 20 -(You can enter "=", "<>", ">", "<", ">=", "<=" in "£") 21 - 22 -**Content, range and data type** 23 - 24 -|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 25 -|(s1)|Comparison data or device storing comparison data|-32768 to 32767|Signed BIN 16 bit|ANY16_S 26 -|(s2)|Comparison data or device storing comparison data|-32768 to 32767|Signed BIN 16 bit|ANY16_S 27 - 28 -**Device used** 29 - 30 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="11" %)**Devices**|((( 31 -**Offset modification** 32 -)))|((( 33 -**Pulse extension** 34 -))) 35 -|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**K**|**H**|**[D]**|**XXP** 36 -|LD=|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●| 37 -|LD>|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●| 38 -|LD<|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●| 39 -|LD>=|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●| 40 -|LD<=|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●| 41 -|LD<>|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●| 42 -|AND=|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●| 43 -|AND>|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●| 44 -|AND<|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●| 45 -|AND>=|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●| 46 -|AND<=|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●| 47 -|AND<>|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●| 48 -|OR=|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●| 49 -|OR>|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●| 50 -|OR<|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●| 51 -|OR>=|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●| 52 -|OR<=|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●| 53 -|OR<>|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●| 54 - 55 -**Features** 56 - 57 -The BIN 16-bit data of the device specified in (s1) and the BIN 16-bit data of the device specified in (s2) are compared by normal open contact processing. 58 - 59 -The comparison operation result of each instruction is shown below. 60 - 61 -|**Instruction Sign**|**Condition**|**Comparison operation result**|**Instruction Sign**|**Condition**|**Comparison operation result** 62 -|==|(s1)=(s2)|(% rowspan="6" %)On state|==|(s1)≠(s2)|(% rowspan="6" %)Non-conduction state 63 -|<>|(s1)≠(s2)|<>|(s1)=(s2) 64 -|>|(s1)>(s2)|>|(s1)≤(s2) 65 -|<|(s1)<(s2)|<|(s1)≥(s2) 66 -|>=|(s1)≥(s2)|>=|(s1)<(s2) 67 -|<=|(s1)≤(s2)|<=|(s1)>(s2) 68 - 69 -**Error code** 70 - 71 -|**Error code**|**Content** 72 -|4085H|(s) read address exceeds the device range 73 - 74 -**Example** 75 - 76 -((( 77 -(1) LD£ instruction: 78 - 79 -(% style="text-align:center" %) 80 -[[image:07-5 Basic instructions_html_1309199eccc7134.png]] 81 -))) 82 - 83 -When the current value of counter C10 is 200, Y10 is set 84 - 85 -When the content of D200 is above -29, and X1 is ON, Y11 is set 86 - 87 -(2) AND£ instruction: 88 - 89 -(% style="text-align:center" %) 90 -[[image:07-5 Basic instructions_html_1c966f74b0bd808e.png]] 91 - 92 -((( 93 -When X0 is ON, or when the current value of counter C10 is 200, Y10 is set 94 - 95 -When X1 is OFF, and the content of data counter D0 is not -10, Y11 is set 96 - 97 - 98 -))) 99 - 100 -(3) OR£ instruction: 101 - 102 -(% style="text-align:center" %) 103 -[[image:07-5 Basic instructions_html_8b000809015ea436.png]] 104 - 105 -((( 106 -When X1 is ON, or when the current value of counter C10 is 200, Y0 is set 107 - 108 -When X2 and M30 are ON, or the content of register D100 is K10000 and above, M60 is set 109 -))) 110 - 111 -== **Signed 32-bit contact comparison instruction** == 112 - 113 -**LDD £, ANDD £, ORD £** 114 - 115 -The BIN 32-bit data of the device specified in (s1) and the BIN 32-bit data of the device specified in (s2) are compared by normal open contact processing. 116 - 117 -LDD£: Normally open contact comparison command 118 - 119 -ANDD£: Normally open contact series link comparison instruction 120 - 121 -ORD£: Normally open contact parallel link comparison instruction 122 - 123 -**Ladder diagram** 124 - 125 -(% style="text-align:center" %) 126 -[[image:07-5 Basic instructions_html_63210db6b7e1512f.png]] 127 - 128 -“=”, “<>”, “>”, “<”, “>=”, “<=” can be input in “£” 129 - 130 -**Content, range and data type** 131 - 132 -|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 133 -|(s1)|Comparison data or device storing comparison data|-2147483648 to 2147483647|Signed BIN 32 bit|ANY32_S 134 -|(s2)|Comparison data or device storing comparison data|-2147483648 to 2147483647|Signed BIN 32 bit|ANY32_S 135 - 136 -**Device used** 137 - 138 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="13" %)**Devices**|((( 139 -**Offset modification** 140 -)))|((( 141 -**Pulse extension** 142 -))) 143 -|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**[D]**|**XXP** 144 -|LDD=|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●|●|●| 145 -|LDD>|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●|●|●| 146 -|LDD<|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●|●|●| 147 -|LDD>=|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●|●|●| 148 -|LDD<=|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●|●|●| 149 -|LDD<>|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●|●|●| 150 -|ANDD=|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●|●|●| 151 -|ANDD>|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●|●|●| 152 -|ANDD<|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●|●|●| 153 -|ANDD>=|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●|●|●| 154 -|ANDD<=|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●|●|●| 155 -|ANDD<>|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●|●|●| 156 -|ORD=|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●|●|●| 157 -|ORD>|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●|●|●| 158 -|ORD<|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●|●|●| 159 -|ORD>=|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●|●|●| 160 -|ORD<=|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●|●|●| 161 -|ORD<>|s1, s2|●|●|●|●|●|●|●|●|●|●|●|●|●|●| 162 - 163 -**Features** 164 - 165 -The BIN 32-bit data of the device specified in (s1) and the BIN 32-bit data of the device specified in (s2) are compared by normal open contact processing. 166 - 167 -The comparison operation result of each instruction is shown below. 168 - 169 -|**Instruction Sign**|**Condition**|**Comparison operation result**|**Instruction Sign**|**Condition**|**Comparison operation result** 170 -|==|(s1)=(s2)|(% rowspan="6" %)On state|==|(s1)≠(s2)|(% rowspan="6" %)Non-conduction state 171 -|<>|(s1)≠(s2)|<>|(s1)=(s2) 172 -|>|(s1)>(s2)|>|(s1)≤(s2) 173 -|<|(s1)<(s2)|<|(s1)≥(s2) 174 -|>=|(s1)≥(s2)|>=|(s1)<(s2) 175 -|<=|(s1)≤(s2)|<=|(s1)>(s2) 176 - 177 -**Error code** 178 - 179 -|**Error code**|**Content** 180 -|4085H|(S) read address exceeds the device range 181 - 182 -**Example** 183 - 184 -(1) LDD£ instruction: 185 - 186 -(% style="text-align:center" %) 187 -[[image:07-5 Basic instructions_html_8acf0d489297c561.png]] 188 - 189 -When the data of LC10 is 200000, Y10 is set, otherwise Y10 is reset. 190 - 191 -When the 32-bit data composed of D201 and D200 exceeds -5000, and X1 is ON, Y11 is turned ON. 192 - 193 -(2) ANDD£ instruction: 194 - 195 -(% style="text-align:center" %) 196 -[[image:07-5 Basic instructions_html_38be93eec0ced6c.png]] 197 - 198 -When X0 is ON and the value of LC10 is 200000, Y10 is set, otherwise it is reset. 199 - 200 -When X1 is OFF and the 32-bit data composed of D1 and D0 is not equal to K-50000, Y11 is set. 201 - 202 -(3) ORD£ instruction: 203 - 204 -(% style="text-align:center" %) 205 -[[image:07-5 Basic instructions_html_8ebfc7b0562cf370.png]] 206 - 207 -When X1 is ON, or the data of LC10 is equal to the data of LC10 is equal to 200000, Y0 is set. 208 - 209 -When X2 and M30 are set, or the double word data composed of D101 and D100 is greater than or equal to 100000, M60 is set. 210 - 211 -== **Single precision real number contact comparison instruction** == 212 - 213 -**LDE £, ANDE £, ORE £** 214 - 215 -The single precision real number of the device specified in (s1) and the single precision real number of the device specified in (s2) are compared by normal open contact processing. 216 - 217 -LDE£: Normally open contact comparison command 218 - 219 -ANDE£: Normally open contact series link comparison instruction 220 - 221 -ORE£: Normally open contact parallel link comparison instruction 222 - 223 -**Ladder diagram** 224 - 225 -(% style="text-align:center" %) 226 -[[image:07-5 Basic instructions_html_6ac28f30e24ad296.png||height="352" width="550"]] 227 - 228 -“=”, “<>”, “>”, “<”, “>=”, “<=” can be input in “£” 229 - 230 -**Content, range and data type** 231 - 232 -|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 233 -|(s1)|Comparison data or the device start number storing the comparison data|0, 2^^-126^^ ≤~|(s)~|< 2^^128^^|Single precision real number|ANYREAL_32 234 -|(s2)|Comparison data or the device start number storing the comparison data|0, 2^^-126^^ ≤~|(s)~|< 2^^128^^|Single precision real number|ANYREAL_32 235 - 236 -**Device used** 237 - 238 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="8" %)**Devices**|((( 239 -**Offset modification** 240 -)))|((( 241 -**Pulse extension** 242 -))) 243 -|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**E**|**[D]**|**XXP** 244 -|LDE=|s1, s2|●|●|●|●|●|●|●|●|●| 245 -|LDE>|s1, s2|●|●|●|●|●|●|●|●|●| 246 -|LDE<|s1, s2|●|●|●|●|●|●|●|●|●| 247 -|LDE>=|s1, s2|●|●|●|●|●|●|●|●|●| 248 -|LDE<=|s1, s2|●|●|●|●|●|●|●|●|●| 249 -|LDE<>|s1, s2|●|●|●|●|●|●|●|●|●| 250 -|ANDE=|s1, s2|●|●|●|●|●|●|●|●|●| 251 -|ANDE>|s1, s2|●|●|●|●|●|●|●|●|●| 252 -|ANDE<|s1, s2|●|●|●|●|●|●|●|●|●| 253 -|ANDE>=|s1, s2|●|●|●|●|●|●|●|●|●| 254 -|ANDE<=|s1, s2|●|●|●|●|●|●|●|●|●| 255 -|ANDE<>|s1, s2|●|●|●|●|●|●|●|●|●| 256 -|ORE=|s1, s2|●|●|●|●|●|●|●|●|●| 257 -|ORD>|s1, s2|●|●|●|●|●|●|●|●|●| 258 -|ORE<|s1, s2|●|●|●|●|●|●|●|●|●| 259 -|ORE>=|s1, s2|●|●|●|●|●|●|●|●|●| 260 -|ORE<=|s1, s2|●|●|●|●|●|●|●|●|●| 261 -|ORE<>|s1, s2|●|●|●|●|●|●|●|●|●| 262 - 263 -**Features** 264 - 265 -The single precision real number of the device specified in (s1) and the single precision real number of the device specified in (s2) are compared by normal open contact processing. 266 - 267 -The comparison operation result of each instruction is shown below. 268 - 269 -|**Instruction Sign**|**Condition**|**Comparison operation result**|**Instruction Sign**|**Condition**|**Comparison operation result** 270 -|E=|(s1)=(s2)|(% rowspan="6" %)On state|E=|(s1)≠(s2)|(% rowspan="6" %)Non-conduction state 271 -|E<>|(s1)≠(s2)|E<>|(s1)=(s2) 272 -|E>|(s1)>(s2)|E>|(s1)≤(s2) 273 -|E<|(s1)<(s2)|E<|(s1)≥(s2) 274 -|E>=|(s1)≥(s2)|E>=|(s1)<(s2) 275 -|E<=|(s1)≤(s2)|E<=|(s1)>(s2) 276 - 277 -**Error code** 278 - 279 -|**Error code**|**Content** 280 -|4084H|When the content of the specified device by (s1) and (s2) is an irregular number, a non-number, or ±∞ 281 -|4085H|The read address of (s1) and (s2exceeds the device range 282 - 283 -**Example** 284 - 285 -(1) LDE£ instruction: 286 - 287 -(% style="text-align:center" %) 288 -[[image:07-5 Basic instructions_html_c4c820cf59601493.png]] 289 - 290 -When the real number input in D0 is equal to E1.23, Y10 is ON, otherwise Y10 is OFF. 291 - 292 -When the real number in R0 is greater than or equal to the real number in LC0, Y11 is ON, otherwise it is OFF. 293 - 294 -If the input in D0, R0, LC0 is not a real number, it will report H4084 error. 295 - 296 -(2) ANDE£ instruction: 297 - 298 -(% style="text-align:center" %) 299 -[[image:07-5 Basic instructions_html_7cdd2117360e179b.png]] 300 - 301 -Only when M0 is ON and D2 real number is not equal to E1.23 and R2 real number is less than real number LC2 , Y12 is ON, otherwise all are OFF. 302 - 303 -(3) ORE£ instruction: 304 - 305 -(% style="text-align:center" %) 306 -[[image:07-5 Basic instructions_html_3eba0bd56176441d.png]] 307 - 308 -When the real number of R4 is less than or equal to the real number of R15, or the real number R6 is equal to the real number R20, Y13 is ON, otherwise Y13 is OFF. 309 - 310 -{{id name="_Toc16295"/}}**String comparison** 311 - 312 -**LDS£、ANDS£、 ORS£** 313 - 314 -{{id name="OLE_LINK27"/}}Compare the string stored after the device number specified in (s1) with the string stored after the device number specified in (s2). 315 - 316 -LDS£: String comparison instruction 317 - 318 -ANDS£: String serial connection comparison instruction 319 - 320 -{{id name="OLE_LINK341"/}}ORS£: String parallel connection comparison instruction 321 - 322 -**Ladder diagram** 323 - 324 -[[image:07-5 Basic instructions_html_5fb3b3b70645fef5.png]] 325 - 326 -“=” and “<>” could be entered in “£” 327 - 328 -**Content, range and data type** 329 - 330 -|**Parameter**|**Content**|**Range**|**Date type**|**Date type(label)** 331 -|(S1)|{{id name="OLE_LINK342"/}}Connection data or the device start number storing the data or the string specified directly|-|String|ANYSTRING_SINGLE 332 -|(S1)|Connection data or the device start number storing the data or the string specified directly|-|{{id name="OLE_LINK29"/}}String|ANYSTRING_SINGLE 333 - 334 -**Device used** 335 - 336 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|((( 337 -**Offset** 338 - 339 -**modification** 340 -)))|((( 341 -**Pulse** 342 - 343 -**extension** 344 -))) 345 -|**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 346 -|LDS=|s1、s2| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | | | | |●| 347 -|LDS<>|s1、s2| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | | | | |●| 348 -|ANDS=|s1、s2| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | | | | |●| 349 -|ANDS<>|s1、s2| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | | | | |●| 350 -|ORS=|s1、s2| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | | | | |●| 351 -|ORS<>|s1、s2| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | | | | |●| 352 - 353 -**Features** 354 - 355 -• Compare the string stored after the device number specified in (s1) with the string stored after the device number specified in (s2). 356 - 357 -• The comparison operation result of each instruction is shown below. 358 - 359 -|**Instruction sign**|**Condition**|**Comparison operation result**|**Instruction sign**|**Condition**|**Comparison operation result** 360 -|= |(s1)=(s2)|(% rowspan="2" %)On stat|= |(s1)≠(s2)|(% rowspan="2" %)Non-conduction state 361 -|<>|(s1)≠(s2)|<>|(s1)=(s2) 362 - 363 -**Error code** 364 - 365 -|**Error code**|**Content** 366 -|4085H|The read address of (s1) or (s2) exceeds the device range 367 -|408AH|The length of the read string of (s1) or (s2) exceeds, and the continuous length of the string exceeds 400 characters. 368 -|408BH|When (s1) or (s2) reading the string, the maximum range of the device is read but 00H is not found as the end. 369 - 370 -**Example** 371 - 372 -1. 1、LDS£ instruction 373 - 374 -[[image:07-5 Basic instructions_html_449a071f61ff5b58.png]] 375 - 376 -1. ANDS£ instruction 377 - 378 -[[image:07-5 Basic instructions_html_dd6aa995d193bdd2.png]] 379 - 380 -1. ORS£ instruction 381 - 382 -[[image:07-5 Basic instructions_html_4f8fb7c94f87c58d.png]] 383 - 384 -{{id name="_Toc11737"/}}[[image:07-5 Basic instructions_html_a2e3294e01b2f206.gif]] **7.12 Clock operation instruction** 385 - 386 -{{id name="_Toc9100"/}}{{id name="_Toc26958"/}}[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] **TADD/The addition of clock data** 387 - 388 388 **TADD(P)** 389 389 390 390 Add the time data stored after the device number specified in (s1) and the time data stored after the device number specified in (s2), and store the result of the addition operation after the device number specified in (d) . ... ... @@ -394,7 +394,7 @@ 394 394 **Content, range and data type** 395 395 396 396 |**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 397 -|(s1)| {{id name="OLE_LINK345"/}}The device start number that stores the added time data|-|Signed BIN 16 bit|(((12 +|(s1)|The device start number that stores the added time data|-|Signed BIN 16 bit|((( 398 398 ANY16_ARRAY 399 399 400 400 (number of elements: 3) ... ... @@ -412,35 +412,34 @@ 412 412 413 413 **Device used** 414 414 415 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|((( 416 -**Offset** 417 - 418 -**modification** 30 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="5" %)**Devices**|((( 31 +**Offset modification** 419 419 )))|((( 420 -**Pulse** 421 - 422 -**extension** 33 +**Pulse extension** 423 423 ))) 424 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**425 -|(% rowspan="3" %)TADD|Parameter 1| | | | | | | | | | | | | | |●|●|●|●|●|| | | | |●|●426 -|Parameter 2| | | | | | | | | | | | | | |●|●|●|●|●|| | | | |●|●427 -|Parameter 3| | | | | | | | | | | | | | |●|●|●|●|●|| | | | |●|●35 +|**T**|**C**|**D**|**R**|**SD**|**[D]**|**XXP** 36 +|(% rowspan="3" %)TADD|Parameter 1|●|●|●|●|●|●|● 37 +|Parameter 2|●|●|●|●|●|●|● 38 +|Parameter 3|●|●|●|●|●|●|● 428 428 429 429 **Features** 430 430 431 431 Add the time data specified in (s1) and the time data specified in (s2), and store the result of the addition in the device number specified in (d) or later. 432 432 433 -[[image:07-5 Basic instructions_html_37222a6e282347f9.png]] 44 +(% style="text-align:center" %) 45 +[[image:07-5 Basic instructions_html_37222a6e282347f9.png||height="79" width="750"]] 434 434 435 435 **Example** 436 436 437 437 When 6:32:40 and 7:48:10 are added together 438 438 439 -[[image:07-5 Basic instructions_html_90138670198ab422.png]] 51 +(% style="text-align:center" %) 52 +[[image:07-5 Basic instructions_html_90138670198ab422.png||height="94" width="750"]] 440 440 441 441 When the calculation result time exceeds 24 o'clock, the carry flag turns ON, and the value after 24 hours is subtracted becomes the calculation result. For example, when 14:20:30 and 20:20:20 are added, the result is not 34:40:50, but 10:40:50. 442 442 443 -[[image:07-5 Basic instructions_html_bac419ce2dc0dc2.png]] 56 +(% style="text-align:center" %) 57 +[[image:07-5 Basic instructions_html_bac419ce2dc0dc2.png||height="91" width="750"]] 444 444 445 445 When the calculation result is 0 (0 hour, 0 minute, 0 second), the zero flag turns on. 446 446 ... ... @@ -452,7 +452,7 @@ 452 452 |SM151|Carry|It is ON when the result of the TADD(P) instruction exceeds the maximum clock data value of 23:59:59 453 453 |SM153|Zero|It is ON when the result of the TADD(P) instruction is 0:00:00 454 454 455 -✎**Note** 69 +✎**Note:** 456 456 457 457 The devices specified in (s1), (s2), (d) occupy 3 points respectively. Be careful not to overlap with the device used for machine control. 458 458 ... ... @@ -461,7 +461,7 @@ 461 461 **Error code** 462 462 463 463 |**Error code**|**Content** 464 -|4085H| {{id name="OLE_LINK344"/}}When reading the specified device range exceeds the corresponding device range78 +|4085H|When reading the specified device range exceeds the corresponding device range 465 465 |4086H|When writing the specified device range exceeds the corresponding device range 466 466 |4084H|((( 467 467 When the values specified in (s1) and (s2) are other than 0 to 23 ... ... @@ -471,24 +471,26 @@ 471 471 472 472 **Example** 473 473 474 -[[image:07-5 Basic instructions_html_4f75eedee7172bbb.png]] 88 +(% style="text-align:center" %) 89 +[[image:07-5 Basic instructions_html_4f75eedee7172bbb.png||height="35" width="349"]] 475 475 476 476 Set D0 time to 16:30:00 and D10 time to 4:30:0 477 477 93 +(% style="text-align:center" %) 478 478 [[image:07-5 Basic instructions_html_c64e0faf2af172f8.png]] 479 479 96 +(% style="text-align:center" %) 480 480 [[image:07-5 Basic instructions_html_66e3a2eadeb2ecbb.png]] 481 481 482 482 After the coil is turned on, the D20 time is 21:0:0 483 483 101 +(% style="text-align:center" %) 484 484 [[image:07-5 Basic instructions_html_a9b235835aa41200.png]] 485 485 104 +== **TSUB/The subtraction of clock data** == 486 486 106 +**TSUB(P)** 487 487 488 -{{id name="_Toc6604"/}}{{id name="_Toc16422"/}}**TSUB/The subtraction of clock data** 489 - 490 -[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] **TSUB(P)** 491 - 492 492 Subtract the time data stored after the device number specified in (s1) and the time data stored after the device number specified in (s2), and store the subtraction result in the device number specified in (d) or later . 493 493 494 494 -[TSUB (s1) (s2) (d)] ... ... @@ -514,24 +514,21 @@ 514 514 515 515 **Device used** 516 516 517 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|((( 518 -**Offset** 519 - 520 -**modification** 133 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="5" %)**Devices**|((( 134 +**Offset modification** 521 521 )))|((( 522 -**Pulse** 523 - 524 -**extension** 136 +**Pulse extension** 525 525 ))) 526 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**527 -|(% rowspan="3" %)TSUB|Parameter 1| | | | | | | | | | | | | | |●|●|●|●|●|| | | | |●|●528 -|Parameter 2| | | | | | | | | | | | | | |●|●|●|●|●|| | | | |●|●529 -|Parameter 3| | | | | | | | | | | | | | |●|●|●|●|●|| | | | |●|●138 +|**T**|**C**|**D**|**R**|**SD**|**[D]**|**XXP** 139 +|(% rowspan="3" %)TSUB|Parameter 1|●|●|●|●|●|●|● 140 +|Parameter 2|●|●|●|●|●|●|● 141 +|Parameter 3|●|●|●|●|●|●|● 530 530 531 531 **Features** 532 532 533 533 Subtract the time data specified in (s1) and the time data specified in (s2), and store the subtraction result in the device number specified in (d) or later. 534 534 147 +(% style="text-align:center" %) 535 535 [[image:07-5 Basic instructions_html_5a93455e4cd8a27.png]] 536 536 537 537 **Example** ... ... @@ -538,10 +538,12 @@ 538 538 539 539 When subtracting 10:40:20 and 3:50:10 540 540 154 +(% style="text-align:center" %) 541 541 [[image:07-5 Basic instructions_html_2473f03fc493780c.png]] 542 542 543 543 When the calculation result time is a negative number, the borrow flag turns on and the data +24 is the calculation result. For example, in the case of subtracting 4:50:32 and 10:42:12, the result is not -6:8:20, but 18:8:20. 544 544 159 +(% style="text-align:center" %) 545 545 [[image:07-5 Basic instructions_html_24b998b4c3c4ec73.png]] 546 546 547 547 When the calculation result is 0 (0 hour, 0 minute, 0 second), the zero flag turns on. ... ... @@ -552,7 +552,7 @@ 552 552 |SM152|Borrow|It is ON when the result of the TSUB(P) instruction is less than 0:00:00 553 553 |SM153|Zero|It is ON when the result of the TSUB(P) instruction is at the time of 0:00:00:00 554 554 555 -✎**Note** 170 +✎**Note:** 556 556 557 557 • The devices specified in (s1), (s2), and (d) occupy 3 points respectively. Be careful not to overlap with the device used for machine control. 558 558 ... ... @@ -571,19 +571,23 @@ 571 571 572 572 **Example** 573 573 574 -[[image:07-5 Basic instructions_html_e3a5d4793d3ccd2d.png]] 189 +(% style="text-align:center" %) 190 +[[image:07-5 Basic instructions_html_e3a5d4793d3ccd2d.png||height="36" width="372"]] 575 575 576 576 Set D0 time to 16:30:00 and D10 time to 4:30:0 577 577 194 +(% style="text-align:center" %) 578 578 [[image:07-5 Basic instructions_html_c64e0faf2af172f8.png]] 579 579 197 +(% style="text-align:center" %) 580 580 [[image:07-5 Basic instructions_html_66e3a2eadeb2ecbb.png]] 581 581 582 582 After the coil is turned on, the D20 time is 12:00:00 583 583 202 +(% style="text-align:center" %) 584 584 [[image:07-5 Basic instructions_html_8f93ea19ba10652b.png]] 585 585 586 - {{id name="_Toc10358"/}}{{id name="_Toc12073"/}}[[image:07-5 Basic instructions_html_501fb256fd034ca6.gif]]**TRD/Clock data reading**205 +**TRD/Clock data reading** 587 587 588 588 **TRD(P)** 589 589 ... ... @@ -602,17 +602,13 @@ 602 602 603 603 **Device used** 604 604 605 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|((( 606 -**Offset** 607 - 608 -**modification** 224 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="4" %)**Devices**|((( 225 +**Offset modification** 609 609 )))|((( 610 -**Pulse** 611 - 612 -**extension** 227 +**Pulse extension** 613 613 ))) 614 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**615 -|TRD|Parameter 1| | | | | | | | | | | | | | |●|●|●|●|| | | | | |●|●229 +|**T**|**C**|**D**|**R**|**[D]**|**XXP** 230 +|TRD|Parameter 1|●|●|●|●|●|● 616 616 617 617 **Features** 618 618 ... ... @@ -638,7 +638,7 @@ 638 638 |SD105|The year data of the clock data is stored in a 4-digit BIN code of the Gregorian calendar. 639 639 |SD106|The week data of the clock data is stored in BIN code. (0: day, 1: one, ..., 6: six) are stored in BIN code. 640 640 641 -✎**Note** 256 +✎**Note:** 642 642 643 643 • The device specified in (d) occupies 7 points. Be careful not to overlap with the device used for machine control. 644 644 ... ... @@ -649,15 +649,17 @@ 649 649 650 650 **Example** 651 651 652 -[[image:07-5 Basic instructions_html_b81c1991fec5b4b1.png]] 267 +(% style="text-align:center" %) 268 +[[image:07-5 Basic instructions_html_b81c1991fec5b4b1.png||height="68" width="250"]] 653 653 654 654 After the M0 coil is turned on, the current date and time are read as 2020-2-19 13:10:38 Wednesday 655 655 656 -[[image:07-5 Basic instructions_html_fe82ecd18ebfd787.png]] 272 +(% style="text-align:center" %) 273 +[[image:07-5 Basic instructions_html_fe82ecd18ebfd787.png||height="48" width="602"]] 657 657 658 - {{id name="_Toc24237"/}}{{id name="_Toc487"/}}**TWR/Clock data writing**275 +== **TWR/Clock data writing** == 659 659 660 - [[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]]**TWR(P)**277 +**TWR(P)** 661 661 662 662 Write the clock data of the built-in real-time clock of the CPU module. 663 663 ... ... @@ -670,17 +670,13 @@ 670 670 671 671 **Device used** 672 672 673 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|((( 674 -**Offset** 675 - 676 -**modification** 290 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="4" %)**Devices**|((( 291 +**Offset modification** 677 677 )))|((( 678 -**Pulse** 679 - 680 -**extension** 293 +**Pulse extension** 681 681 ))) 682 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**683 -|TWR|Parameter 1| | | | | | | | | | | | | | |●|●|●|●|| | | | | |●|●295 +|**T**|**C**|**D**|**R**|**[D]**|**XXP** 296 +|TWR|Parameter 1|●|●|●|●|●|● 684 684 685 685 **Features** 686 686 ... ... @@ -715,7 +715,7 @@ 715 715 |SD105|The year data of the clock data is stored in a 4-digit BIN code of the Gregorian calendar. 716 716 |SD106|The week data of the clock data is stored in BIN code. (0: day, 1: one, ..., 6: six) are stored in BIN code. 717 717 718 -✎**Note** 331 +✎**Note:** 719 719 720 720 The device specified in (s) occupies 7 points. Be careful not to overlap with the device used for machine control. 721 721 ... ... @@ -728,13 +728,15 @@ 728 728 729 729 Set D0 date and time to 2020-2-19 12:36:00 in advance 730 730 731 -[[image:07-5 Basic instructions_html_994c66d1a4cbd45f.png]] 344 +(% style="text-align:center" %) 345 +[[image:07-5 Basic instructions_html_994c66d1a4cbd45f.png||height="57" width="305"]] 732 732 733 733 At the moment when the time 12:36:00 arrives, turn on the M0 coil and write the time. 734 734 735 -[[image:07-5 Basic instructions_html_bf3e906ee5265598.png]] 349 +(% style="text-align:center" %) 350 +[[image:07-5 Basic instructions_html_bf3e906ee5265598.png||height="42" width="586"]] 736 736 737 - {{id name="_Toc5357"/}}{{id name="_Toc6196"/}}[[image:07-5Basic instructions_html_11b3991e89e21efc.gif]]**HTOS/16-bit data conversion of time data (hour, minute, second → second)**352 +== **HTOS/16-bit data conversion of time data (hour, minute, second → second)** == 738 738 739 739 **HTOS(P)** 740 740 ... ... @@ -750,26 +750,26 @@ 750 750 751 751 **Device used** 752 752 753 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 754 -**Pulse** 755 - 756 -**extension** 368 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="9" %)**Devices**|**Offset modification**|((( 369 +**Pulse extension** 757 757 ))) 758 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**759 -|(% rowspan="2" %)HTOS|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|| | | | |●|●760 -|Parameter 2| | | | | | | | | | | |●|●|●|●|●|●|●|●|| | | | |●|●371 +|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**[D]**|**XXP** 372 +|(% rowspan="2" %)HTOS|Parameter 1|●|●|●|●|●|●|●|●|●|●|● 373 +|Parameter 2| |●|●|●|●|●|●|●|●|●|● 761 761 762 762 **Features** 763 763 764 764 Convert the time data stored after the device number specified in (s) into seconds and store the conversion result in the device specified in (d). 765 765 766 -[[image:07-5 Basic instructions_html_a84b7741fd5bef2f.png]] 379 +(% style="text-align:center" %) 380 +[[image:07-5 Basic instructions_html_a84b7741fd5bef2f.png||height="130" width="550"]] 767 767 768 768 **Example** 769 769 770 770 When 4 hours, 29 minutes and 31 seconds are specified in (s) 771 771 772 -[[image:07-5 Basic instructions_html_5effb7bc9b8e5cf7.png]] 386 +(% style="text-align:center" %) 387 +[[image:07-5 Basic instructions_html_5effb7bc9b8e5cf7.png||height="162" width="550"]] 773 773 774 774 **Error code** 775 775 ... ... @@ -777,7 +777,7 @@ 777 777 |4085H|When reading the specified device range exceeds the corresponding device range 778 778 |4086H|When writing the specified device range exceeds the corresponding device range 779 779 |4084H|((( 780 - {{id name="OLE_LINK348"/}}When the calculation result is not in the range of 0 to 32767395 +When the calculation result is not in the range of 0 to 32767 781 781 782 782 When the value specified in (s) is not in the range of 0 to 9 783 783 ... ... @@ -786,19 +786,22 @@ 786 786 787 787 **Example** 788 788 789 -[[image:07-5 Basic instructions_html_e23e38c4ba4c34bb.png]] 404 +(% style="text-align:center" %) 405 +[[image:07-5 Basic instructions_html_e23e38c4ba4c34bb.png||height="43" width="338"]] 790 790 791 791 D0 time is set to 5:36:53 792 792 409 +(% style="text-align:center" %) 793 793 [[image:07-5 Basic instructions_html_2866a121e5ca5713.png]] 794 794 795 795 The time of D10 after the M0 coil is turned on is as below. 796 796 414 +(% style="text-align:center" %) 797 797 [[image:07-5 Basic instructions_html_1dd6c5de05890797.png]] 798 798 799 - {{id name="_Toc13431"/}}{{id name="_Toc5278"/}}**DHTOS/32-bit data conversion of time data (hour, minute, second → second)**417 +== **DHTOS/32-bit data conversion of time data (hour, minute, second → second)** == 800 800 801 - [[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]]**DHTOS(P)**419 +**DHTOS(P)** 802 802 803 803 Convert the time data stored after the device number specified in (s) into seconds and store the conversion result as BIN 32-bit data in the device specified in (d). 804 804 ... ... @@ -812,30 +812,28 @@ 812 812 813 813 **Device used** 814 814 815 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|((( 816 -**Offset** 817 - 818 -**modification** 433 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="9" %)**Devices**|((( 434 +**Offset modification** 819 819 )))|((( 820 -**Pulse** 821 - 822 -**extension** 436 +**Pulse extension** 823 823 ))) 824 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**825 -|(% rowspan="2" %)DHTOS|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|| | | | |●|●826 -|Parameter 2| | | | | | | | | | | |●|●|●|●|●|●|●|●|| | | | |●|●438 +|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**[D]**|**XXP** 439 +|(% rowspan="2" %)DHTOS|Parameter 1|●|●|●|●|●|●|●|●|●|●|● 440 +|Parameter 2| |●|●|●|●|●|●|●|●|●|● 827 827 828 828 **Features** 829 829 830 830 Convert the time data stored after the device number specified in (s) into seconds and store the conversion result in the device specified in (d). 831 831 832 -[[image:07-5 Basic instructions_html_f4be08508575ea01.png]] 446 +(% style="text-align:center" %) 447 +[[image:07-5 Basic instructions_html_f4be08508575ea01.png||height="99" width="550"]] 833 833 834 834 **Example** 835 835 836 836 When 35 hours, 10 minutes and 58 seconds are specified in (s) 837 837 838 -[[image:07-5 Basic instructions_html_5b9ad230ed5e1fd0.png]] 453 +(% style="text-align:center" %) 454 +[[image:07-5 Basic instructions_html_5b9ad230ed5e1fd0.png||height="125" width="550"]] 839 839 840 840 **Error code** 841 841 ... ... @@ -850,17 +850,20 @@ 850 850 851 851 **Example** 852 852 853 -[[image:07-5 Basic instructions_html_ae8ab4379e8bdb91.png]] 469 +(% style="text-align:center" %) 470 +[[image:07-5 Basic instructions_html_ae8ab4379e8bdb91.png||height="45" width="263"]] 854 854 855 855 D0 time is set to 15:33:24 856 856 857 -[[image:07-5 Basic instructions_html_57a15d9e1045e93e.png]] 474 +(% style="text-align:center" %) 475 +[[image:07-5 Basic instructions_html_57a15d9e1045e93e.png||height="41" width="313"]] 858 858 859 859 The second of D10 after the M0 coil is turned on is 860 860 861 -[[image:07-5 Basic instructions_html_194e906b1dc12078.png]] 479 +(% style="text-align:center" %) 480 +[[image:07-5 Basic instructions_html_194e906b1dc12078.png||height="64" width="365"]] 862 862 863 - {{id name="_Ref22686"/}}{{id name="_Toc11231"/}}{{id name="_Toc7401"/}}[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]]**HOUR/Hour measuring 16-bit**482 +**HOUR/Hour measuring 16-bit** 864 864 865 865 **HOUR(P)** 866 866 ... ... @@ -885,19 +885,15 @@ 885 885 886 886 **Device used** 887 887 888 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|((( 889 -**Offset** 890 - 891 -**modification** 507 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="17" %)**Devices**|((( 508 +**Offset modification** 892 892 )))|((( 893 -**Pulse** 894 - 895 -**extension** 510 +**Pulse extension** 896 896 ))) 897 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**898 -|(% rowspan="3" %)HOUR|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|| |●|●| |●|●899 -|Parameter 2| | | | | | | | | | | | | | | | |●|●|●| | | || |●|●900 -|Parameter 3| |●|●|●|●|| | | |●| | | | | | | | | | | | || |●|●512 +|**Y**|**M**|**S**|**SM**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**K**|**H**|**E**|**[D]**|**XXP** 513 +|(% rowspan="3" %)HOUR|Parameter 1| | | | | |●|●|●|●|●|●|●|●|●|●|●| |●|● 514 +|Parameter 2| | | | | | | | | | | |●|●|●| | | |●|● 515 +|Parameter 3|●|●|●|●|●| | | | | | | | | | | | |●|● 901 901 902 902 **Features** 903 903 ... ... @@ -919,7 +919,7 @@ 919 919 920 920 • The measurement stops when the current value reaches the 16-bit maximum. To continue the measurement, clear the current value of (d1) to (d1)+1. 921 921 922 -✎**Note** 537 +✎**Note:** 923 923 924 924 • The device specified in (d1) occupies 2 points. Be careful not to overlap with the device used for machine control. 925 925 ... ... @@ -932,15 +932,14 @@ 932 932 |4086H|When writing the specified device range exceeds the corresponding device range 933 933 |4084H|When the value of (s) is negative 934 934 935 - 936 - 937 937 **Example** 938 938 939 -[[image:07-5 Basic instructions_html_7570f8c392470a9f.png]] 552 +(% style="text-align:center" %) 553 +[[image:07-5 Basic instructions_html_7570f8c392470a9f.png||height="45" width="320"]] 940 940 941 941 When M0 = ON, the duration of the state is accumulated, the time is recorded in D0, and the seconds less than 1 hour are recorded in D1. When the accumulated time of D0 reaches 98 hours, the Y0 output state is ON. When the timing conditions are met, after reaching the specified value (K98), the accumulated timing will continue and the reading will continue to increase; the current time value D0 reaches the maximum value of 32767 hours and D1 reaches 3599 seconds, the timing measurement will stop. The current time values D0 and D1 are cleared to 0. 942 942 943 - {{id name="_Toc8523"/}}{{id name="_Toc9364"/}}[[image:07-5Basic instructions_html_11b3991e89e21efc.gif]]**DHOUR/Hour measuring 32 bits**557 +== **DHOUR/Hour measuring 32 bits** == 944 944 945 945 **DHOUR(P)** 946 946 ... ... @@ -952,9 +952,7 @@ 952 952 953 953 |**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 954 954 |(s)|((( 955 -The time when the alarm (d2) is turned ON 956 - 957 -(set by one hour) 569 +The time when the alarm (d2) is turned ON (set by one hour) 958 958 )))|0 to 2147483647|Signed BIN 32 bit|ANY32 959 959 |(d1)|Device that stores the current value of measurement (specified data register for power failure retention)|-|Unsigned BIN 32 bit|((( 960 960 ANY32_ARRAY ... ... @@ -965,19 +965,15 @@ 965 965 966 966 **Device used** 967 967 968 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|((( 969 -**Offset** 970 - 971 -**modification** 580 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="18" %)**Devices**|((( 581 +**Offset modification** 972 972 )))|((( 973 -**Pulse** 974 - 975 -**extension** 583 +**Pulse extension** 976 976 ))) 977 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**978 -|(% rowspan="3" %)DHOUR|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●||●|●979 -|Parameter 2| | | | | | | | | | | | | | | | |●|●|●| | | | ||●|●980 -|Parameter 3| |●|●|●|●|| | | |●| | | | | | | | | | | | | ||●|●585 +|**Y**|**M**|**S**|**SM**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**[D]**|**XXP** 586 +|(% rowspan="3" %)DHOUR|Parameter 1| | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●|●|● 587 +|Parameter 2| | | | | | | | | | | |●|●|●| | | | |●|● 588 +|Parameter 3|●|●|●|●|●| | | | | | | | | | | | | |●|● 981 981 982 982 **Features** 983 983 ... ... @@ -999,7 +999,7 @@ 999 999 1000 1000 • The measurement stops when the current value reaches the 32-bit maximum. To continue the measurement, clear the current value of (d1) to (d1)+2. 1001 1001 1002 -✎**Note** 610 +✎**Note:** 1003 1003 1004 1004 • The device specified in (d1) occupies 3 points. Be careful not to overlap with the device used for machine control. 1005 1005 ... ... @@ -1012,17 +1012,16 @@ 1012 1012 |4086H|When writing the specified device range exceeds the corresponding device range 1013 1013 |4084H|When the value of (s) is negative 1014 1014 1015 - 1016 - 1017 1017 **Example** 1018 1018 1019 -[[image:07-5 Basic instructions_html_3f1ef5ecc835de30.png]] 625 +(% style="text-align:center" %) 626 +[[image:07-5 Basic instructions_html_3f1ef5ecc835de30.png||height="43" width="448"]] 1020 1020 1021 1021 When M0=ON, the duration of this state is accumulated, the time is recorded in D1, D0, and the seconds less than 1 hour are recorded in D2. When the accumulated time of D1, D0 reaches 1000 hours, the Y0 output state is ON. When the timing conditions are met, after reaching the specified value (K1000), the accumulated timing will continue, and the reading will continue to increase; the current time values D1 and D0 reach the maximum value of 2147483647 hours, and when D2 reaches 3599 seconds, the timing measurement will stop and the timing should be restarted. The current time values D0, D1, and D2 must be cleared to 0. 1022 1022 1023 -** {{id name="_Toc11629"/}}STOH/16-bit data conversion of time data (second → hour, minute, second)**630 +== **STOH/16-bit data conversion of time data (second → hour, minute, second)** == 1024 1024 1025 - [[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]]**STOH(P)**632 +**STOH(P)** 1026 1026 1027 1027 Convert the second 16-bit data stored in the device number specified in (s) into hour, minute, and second, and store the conversion result in the device specified in (d) and later. 1028 1028 ... ... @@ -1031,39 +1031,35 @@ 1031 1031 **Content, range and data type** 1032 1032 1033 1033 |**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 1034 -|(s)| {{id name="OLE_LINK353"/}}The device start number that stores the clock data before conversion|0 to 32767|Signed BIN 16 bit|ANY16641 +|(s)|The device start number that stores the clock data before conversion|0 to 32767|Signed BIN 16 bit|ANY16 1035 1035 |(d)|The device start number that stores the converted clock data|-|Signed BIN 16 bit|((( 1036 -ANY16_ARRAY 1037 - 1038 -(number of elements: 3) 643 +ANY16_ARRAY (number of elements: 3) 1039 1039 ))) 1040 1040 1041 1041 **Device used** 1042 1042 1043 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|((( 1044 -**Offset** 1045 - 1046 -**modification** 648 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="9" %)**Devices**|((( 649 +**Offset modification** 1047 1047 )))|((( 1048 -**Pulse** 1049 - 1050 -**extension** 651 +**Pulse extension** 1051 1051 ))) 1052 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**1053 -|(% rowspan="2" %)STOH|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|| | | | |●|●1054 -|Parameter 2| | | | | | | | | | | |●|●|●|●|●|●|●|●|| | | | |●|●653 +|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**[D]**|**XXP** 654 +|(% rowspan="2" %)STOH|Parameter 1|●|●|●|●|●|●|●|●|●|●|● 655 +|Parameter 2| |●|●|●|●|●|●|●|●|●|● 1055 1055 1056 1056 **Features** 1057 1057 1058 1058 Convert the second data stored after the device number specified in (s) into hour, minute, and second, and store the conversion result in the device specified in (d) and later. 1059 1059 1060 -[[image:07-5 Basic instructions_html_1f5f3f1d80af2a34.png]] 661 +(% style="text-align:center" %) 662 +[[image:07-5 Basic instructions_html_1f5f3f1d80af2a34.png||height="110" width="550"]] 1061 1061 1062 1062 **Example** 1063 1063 1064 1064 When 29,011 seconds are specified in (s) 1065 1065 1066 -[[image:07-5 Basic instructions_html_682516cbf773f515.png]] 668 +(% style="text-align:center" %) 669 +[[image:07-5 Basic instructions_html_682516cbf773f515.png||height="163" width="550"]] 1067 1067 1068 1068 **Error code** 1069 1069 ... ... @@ -1074,17 +1074,19 @@ 1074 1074 1075 1075 **Example** 1076 1076 1077 -[[image:07-5 Basic instructions_html_e783349d57adf7d2.png]] 680 +(% style="text-align:center" %) 681 +[[image:07-5 Basic instructions_html_e783349d57adf7d2.png||height="47" width="350"]] 1078 1078 1079 1079 Set D0 seconds to 12537 1080 1080 1081 1081 The hour, minute and second of D10 after the M0 coil is turned on are 1082 1082 1083 -[[image:07-5 Basic instructions_html_d3c33949e8684891.png]] 687 +(% style="text-align:center" %) 688 +[[image:07-5 Basic instructions_html_d3c33949e8684891.png||height="52" width="645"]] 1084 1084 1085 - {{id name="_Toc10764"/}}{{id name="_Toc30243"/}}**DSTOH/32-bit data conversion of time data (second → hour, minute, second)**690 +== **DSTOH/32-bit data conversion of time data (second → hour, minute, second)** == 1086 1086 1087 - [[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]]**DSTOH(P)**692 +**DSTOH(P)** 1088 1088 1089 1089 Convert the second 32-bit data of second stored in the device number specified in (s) into hour, minute, and second, and store the conversion result in the device specified in (d) and later. 1090 1090 ... ... @@ -1095,37 +1095,33 @@ 1095 1095 |**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 1096 1096 |(s)|The device start number that stores the clock data before conversion|0 to 117964799|Signed BIN 32 bit|ANY32 1097 1097 |(d)|The device start number that stores the converted clock data|-|Signed BIN 16 bit|((( 1098 -ANY16_ARRAY 1099 - 1100 -(number of elements: 3) 703 +ANY16_ARRAY (number of elements: 3) 1101 1101 ))) 1102 1102 1103 1103 **Device used** 1104 1104 1105 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|((( 1106 -**Offset** 1107 - 1108 -**modification** 708 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="9" %)**Devices**|((( 709 +**Offset modification** 1109 1109 )))|((( 1110 -**Pulse** 1111 - 1112 -**extension** 711 +**Pulse extension** 1113 1113 ))) 1114 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**1115 -|(% rowspan="2" %)DSTOH|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|| | | | |●|●1116 -|Parameter 2| | | | | | | | | | | |●|●|●|●|●|●|●|●|| | | | |●|●713 +|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**[D]**|**XXP** 714 +|(% rowspan="2" %)DSTOH|Parameter 1|●|●|●|●|●|●|●|●|●|●|● 715 +|Parameter 2| |●|●|●|●|●|●|●|●|●|● 1117 1117 1118 1118 **Features** 1119 1119 1120 1120 Convert the second data stored after the device number specified in (s) into hour, minute, and second, and store the conversion result in the device specified in (d) and later. 1121 1121 1122 -[[image:07-5 Basic instructions_html_cbf13fc3d10fbe61.png]] 721 +(% style="text-align:center" %) 722 +[[image:07-5 Basic instructions_html_cbf13fc3d10fbe61.png||height="99" width="600"]] 1123 1123 1124 1124 **Example** 1125 1125 1126 1126 When 45,325 seconds is specified in (s) 1127 1127 1128 -[[image:07-5 Basic instructions_html_d6045506b13275a0.png]] 728 +(% style="text-align:center" %) 729 +[[image:07-5 Basic instructions_html_d6045506b13275a0.png||height="135" width="600"]] 1129 1129 1130 1130 **Error code** 1131 1131 ... ... @@ -1136,15 +1136,17 @@ 1136 1136 1137 1137 **Example** 1138 1138 1139 -[[image:07-5 Basic instructions_html_e7dd49d953db6da4.png]] 740 +(% style="text-align:center" %) 741 +[[image:07-5 Basic instructions_html_e7dd49d953db6da4.png||height="39" width="316"]] 1140 1140 1141 1141 Set D0 seconds to 2152537 1142 1142 1143 1143 The hour, minute and second of D10 after the M0 coil is turned on are 1144 1144 1145 -[[image:07-5 Basic instructions_html_10d57bde1ac0a218.png]] 747 +(% style="text-align:center" %) 748 +[[image:07-5 Basic instructions_html_10d57bde1ac0a218.png||height="52" width="661"]] 1146 1146 1147 - {{id name="_Toc2937"/}}{{id name="_Toc24209"/}}[[image:07-5Basic instructions_html_11b3991e89e21efc.gif]]**TCMP/Clock data comparison**750 +== **TCMP/Clock data comparison** == 1148 1148 1149 1149 **TCMP(P)** 1150 1150 ... ... @@ -1163,29 +1163,26 @@ 1163 1163 1164 1164 **Device used** 1165 1165 1166 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|((( 1167 -**Offset** 1168 - 1169 -**modification** 769 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="17" %)**Devices**|((( 770 +**Offset modification** 1170 1170 )))|((( 1171 -**Pulse** 1172 - 1173 -**extension** 772 +**Pulse extension** 1174 1174 ))) 1175 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**1176 -|(% rowspan="5" %)TCMP|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|| |●|●| |●|●1177 -|Parameter 2| | | | | | | | | | |●|●|●|●|●|●|●|●|●|| |●|●| |●|●1178 -|Parameter 3| | | | | | | | | | |●|●|●|●|●|●|●|●|●|| |●|●| |●|●1179 -|Parameter 4| | | | | | | | | | | | | | |●|●|●|●|●| | | || |●|●1180 -|Parameter 5| |●|●|●|●|| | | |●| | | | | | | | | | | | || |●|●774 +|**Y**|**M**|**S**|**SM**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**K**|**H**|**E**|**[D]**|**XXP** 775 +|(% rowspan="5" %)TCMP|Parameter 1| | | | | |●|●|●|●|●|●|●|●|●|●|●| |●|● 776 +|Parameter 2| | | | | |●|●|●|●|●|●|●|●|●|●|●| |●|● 777 +|Parameter 3| | | | | |●|●|●|●|●|●|●|●|●|●|●| |●|● 778 +|Parameter 4| | | | | | | | | |●|●|●|●|●| | | |●|● 779 +|Parameter 5|●|●|●|●|●| | | | | | | | | | | | |●|● 1181 1181 1182 1182 **Features** 1183 1183 1184 1184 Compare the time of the reference time (hour, minute, second) [(s1), (s2), (s3)] with the time data (hour, minute, second) [(s4), (s4)+1, (s4) +2] Compare the size and turn on/off the 3 points from (d) according to the result of the same size. 1185 1185 1186 -[[image:07-5 Basic instructions_html_5df7ad3057fada12.png]] 785 +(% style="text-align:center" %) 786 +[[image:07-5 Basic instructions_html_5df7ad3057fada12.png||height="385" width="750"]] 1187 1187 1188 -✎**Note** 788 +✎**Note:** 1189 1189 1190 1190 The device specified in (s4) and (d) occupies 3 points. Be careful not to overlap with the device used for machine control. 1191 1191 ... ... @@ -1199,26 +1199,29 @@ 1199 1199 |4084H|((( 1200 1200 When the value specified in (s) and (s4) is not in the range of 0 to 23 1201 1201 1202 - {{id name="OLE_LINK355"/}}When the value specified in (s2),(s3) (s4)+1 and (s4)+2 is not in the range of 0 to 59802 +When the value specified in (s2),(s3) (s4)+1 and (s4)+2 is not in the range of 0 to 59 1203 1203 ))) 1204 1204 1205 1205 **Example** 1206 1206 1207 -[[image:07-5 Basic instructions_html_fcc16317cf7c0700.png]] 807 +(% style="text-align:center" %) 808 +[[image:07-5 Basic instructions_html_fcc16317cf7c0700.png||height="68" width="359"]] 1208 1208 1209 1209 Set D10 to 1, D11 to 30, D12 to 0 1210 1210 1211 1211 When M0 is turned on, the time that D23 will come is 0:31:27 1212 1212 1213 -[[image:07-5 Basic instructions_html_de97dd7a612b2323.png]] 814 +(% style="text-align:center" %) 815 +[[image:07-5 Basic instructions_html_de97dd7a612b2323.png||height="50" width="653"]] 1214 1214 1215 1215 M10 is turned ON 1216 1216 1217 -[[image:07-5 Basic instructions_html_56e2d606adc09fd.png]] 819 +(% style="text-align:center" %) 820 +[[image:07-5 Basic instructions_html_56e2d606adc09fd.png||height="52" width="239"]] 1218 1218 1219 - {{id name="_Toc29031"/}}{{id name="_Toc22923"/}}**TZCP/Clock data bandwidth comparison**822 +== **TZCP/Clock data bandwidth comparison** == 1220 1220 1221 - [[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]]**TZCP(P)**824 +**TZCP(P)** 1222 1222 1223 1223 Compare the comparison time of the high and low points specified in (s1) and (s2) with the time data specified in (s3), and turn the bit device specified in (d) ON/OFF according to its size and bandwidth. 1224 1224 ... ... @@ -1228,46 +1228,37 @@ 1228 1228 1229 1229 |**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 1230 1230 |(s1)|Specify the "hour" of the lower limit time (hour, minute, second)|-|Signed BIN 16 bit|((( 1231 -ANY16_ARRAY 1232 - 1233 -(number of elements: 3) 834 +ANY16_ARRAY (number of elements: 3) 1234 1234 ))) 1235 1235 |(s2)|Specify the "hour" of the lower limit time (hour, minute, second)|-|Signed BIN 16 bit|((( 1236 -ANY16_ARRAY 1237 - 1238 -(number of elements: 3) 837 +ANY16_ARRAY (number of elements: 3) 1239 1239 ))) 1240 1240 |(s3)|Specify "hour" of time data (hour, minute, second)|-|Signed BIN 16 bit|((( 1241 -ANY16_ARRAY 1242 - 1243 -(number of elements: 3) 840 +ANY16_ARRAY (number of elements: 3) 1244 1244 ))) 1245 1245 |(d)|The bit device is turned ON/OFF according to the comparison result.|-|Bit|((( 1246 -ANY16_ARRAY 1247 - 1248 -(number of elements: 3) 843 +ANY16_ARRAY (number of elements: 3) 1249 1249 ))) 1250 1250 1251 1251 **Device used** 1252 1252 1253 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 1254 -**Pulse** 1255 - 1256 -**extension** 848 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="10" %)**Devices**|**Offset modification**|((( 849 +**Pulse extension** 1257 1257 ))) 1258 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**1259 -|(% rowspan="4" %)TZCP|Parameter 1| | | | | | | | | | | | | | |●|●|●|●|●|| | | | |●|●1260 -|Parameter 2| | | | | | | | | | | | | | |●|●|●|●|●|| | | | |●|●1261 -|Parameter 3| | | | | | | | | | | | | | |●|●|●|●|●|| | | | |●|●1262 -|Parameter 4| |●|●|●|●|| | | |●| | | | | || | | | | | | | |●|●851 +|**Y**|**M**|**S**|**SM**|**D.b**|**T**|**C**|**D**|**R**|**SD**|**[D]**|**XXP** 852 +|(% rowspan="4" %)TZCP|Parameter 1| | | | | |●|●|●|●|●|●|● 853 +|Parameter 2| | | | | |●|●|●|●|●|●|● 854 +|Parameter 3| | | | | |●|●|●|●|●|●|● 855 +|Parameter 4|●|●|●|●|●| | | | | |●|● 1263 1263 1264 1264 **Features** 1265 1265 1266 1266 Compare the comparison time of the high and low points specified in (s1) and (s2) with the time data specified in (s3), and turn the bit device specified in (d) ON/OFF according to its size and bandwidth. 1267 1267 1268 -[[image:07-5 Basic instructions_html_844291270080313d.png]] 861 +(% style="text-align:center" %) 862 +[[image:07-5 Basic instructions_html_844291270080313d.png||height="339" width="750"]] 1269 1269 1270 -✎**Note** 864 +✎**Note:** 1271 1271 1272 1272 • The devices specified in (s1), (s2), (s3), (d) occupy 3 points. Be careful not to overlap with the device used for machine control. 1273 1273 ... ... @@ -1288,1176 +1288,23 @@ 1288 1288 1289 1289 **Example** 1290 1290 1291 -[[image:07-5 Basic instructions_html_30027a2387c26c2e.png]] 885 +(% style="text-align:center" %) 886 +[[image:07-5 Basic instructions_html_30027a2387c26c2e.png||height="46" width="439"]] 1292 1292 1293 1293 Set D0 time to 16:30:00 and D10 time to 4:30:0 1294 1294 1295 -[[image:07-5 Basic instructions_html_c64e0faf2af172f8.png]] 890 +(% style="text-align:center" %) 891 +[[image:07-5 Basic instructions_html_c64e0faf2af172f8.png||height="49" width="626"]] 1296 1296 1297 -[[image:07-5 Basic instructions_html_66e3a2eadeb2ecbb.png]] 893 +(% style="text-align:center" %) 894 +[[image:07-5 Basic instructions_html_66e3a2eadeb2ecbb.png||height="50" width="625"]] 1298 1298 1299 1299 After the coil is turned on, the reading time to D20 time is 8:30:00 1300 1300 1301 -[[image:07-5 Basic instructions_html_75c44dad07eaf80a.png]] 898 +(% style="text-align:center" %) 899 +[[image:07-5 Basic instructions_html_75c44dad07eaf80a.png||height="49" width="625"]] 1302 1302 1303 1303 M0/M12 is ON 1304 1304 1305 -[[image:07-5 Basic instructions_html_f512f36261705953.png]] 1306 - 1307 -{{id name="_Toc6129"/}}[[image:07-5 Basic instructions_html_a2e3294e01b2f206.gif]] **7.13 Data control instructions** 1308 - 1309 -{{id name="_Toc3339"/}}{{id name="_Toc27829"/}}{{id name="_Toc9204"/}}**BAND/BIN 16-bit data dead zone control** 1310 - 1311 -[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] **BAND(P)** 1312 - 1313 -The input value (BIN 16-bit value) specified in (s3) controls the output value stored in the device specified in (d) according to the upper and lower limits of the dead zone specified in (s1) and (s2). 1314 - 1315 --[BAND (s1) (s2) (S3) (d)] 1316 - 1317 -**Content, range and data type** 1318 - 1319 -|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 1320 -|(s1)|Lower limit of dead zone (no output zone)|-32,768 to +32,767|Signed BIN 16 bit|ANY16_S 1321 -|(s2)|Upper limit of dead zone (no output zone)|-32,768 to +32,767|Signed BIN 16 bit|ANY16_S 1322 -|(S3)|Input value controlled by dead zone control|-32768 to +32,767|Signed BIN 16 bit|ANY16_S 1323 -|(D)|The start number of the device that stores the output value controlled by the dead zone control|-|Signed BIN 16 bit|ANY16_S 1324 - 1325 -**Device used** 1326 - 1327 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|((( 1328 -**Offset** 1329 - 1330 -**modification** 1331 -)))|((( 1332 -**Pulse** 1333 - 1334 -**extension** 1335 -))) 1336 -|**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 1337 -|(% rowspan="4" %)BAND|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | |●|●| |●|● 1338 -|Parameter 2| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | |●|●| |●|● 1339 -|Parameter 3| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | | | | |●|● 1340 -|Parameter 4| | | | | | | | | | | |●|●|●|●|●|●|●|●| | | | | |●|● 1341 - 1342 -**Features** 1343 - 1344 -The input value (BIN 16-bit value) specified in (s3) controls the output value stored in the device specified in (d) according to the upper and lower limits of the dead zone specified in (s1) and (s2). The output value is controlled as follows. 1345 - 1346 -|**Condition**|**The value stored in the output value** 1347 -|When dead zone low limit (s1)> input value (s3)|Input value (s3)-Dead zone low limit (s1) 1348 -|When dead zone high limit (s1) <input value (s3)|Input value (s3)- Dead zone high limit (s2) 1349 -|When dead zone low limit (s1) ≤ input value (s3) ≤ dead zone low limit (s2)|0 1350 - 1351 - 1352 -((( 1353 -•When the output value stored in (d) is a signed BIN 16-bit value, and the operation result exceeds the range of -32768 to 32767, the situation is shown in the following example. 1354 - 1355 -For example, when (s1) is 10 and (s3) is -32768, 1356 - 1357 -the output value = -32768-10=8000H-000AH=7FFFH=32758. 1358 - 1359 -[[image:07-5 Basic instructions_html_6850e21a76b813c0.png]] 1360 -))) 1361 - 1362 -**Error code** 1363 - 1364 -|**Error code**|**Content** 1365 -|4085H|When the specified device range for reading exceeds the range of the corresponding device. 1366 -|4086H|When the specified device range for writing exceeds the range of the corresponding device. 1367 -|4084H|When the low limit specified in (s1) is greater than the high limit specified in (s2). 1368 - 1369 -**Example ** 1370 - 1371 -[[image:07-5 Basic instructions_html_c0e65cfeed403ecf.png]] 1372 - 1373 -When X000 is ON, when D0<(-1,000), the value of ( D0)-(-1,000) is stored in (D1). 1374 - 1375 -• When -1,000≦ D0≦1,000, 0 is stored in D1. 1376 - 1377 -• When D0<1,000, the value of (D0)-1,000 is stored in D1. 1378 - 1379 -{{id name="_Toc1180"/}}{{id name="_Toc21657"/}}{{id name="_Toc27323"/}}[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] **DBAND/BIN 32-bit data dead zone control** 1380 - 1381 -**DBAND(P)** 1382 - 1383 -The input value (BIN 32-bit value) specified in (s3) controls the output value stored in the device specified in (d) according to the upper and lower limits of the dead zone specified in (s1) and (s2). 1384 - 1385 --[DBAND (s1) (s2) (S3) (d)] 1386 - 1387 -**Content, range and data type** 1388 - 1389 -|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 1390 -|(s1)|Dead zone low limit (no output zone)|-2,147,483,648 to +2,147,483,647|Signed BIN 32 bit|ANY32_S 1391 -|(s2)|Dead zone high limit (no output zone)|-2,147,483,648 to +2,147,483,647|Signed BIN 32 bit|ANY32_S 1392 -|(S3)|Input value controlled by dead zone control|-2,147,483,648 to +2,147,483,647|Signed BIN 32 bit|ANY32_S 1393 -|(d)|The start number of the device that stores the output value controlled by the dead zone control|-|Signed BIN 32 bit|ANY32_S 1394 - 1395 -**Device used** 1396 - 1397 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 1398 -**Pulse** 1399 - 1400 -**extension** 1401 -))) 1402 -|**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 1403 -|(% rowspan="4" %)DBAND|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●| |●|● 1404 -|Parameter 2| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●| |●|● 1405 -|Parameter 3| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●| | | |●|● 1406 -|Parameter 4| | | | | | | | | | | |●|●|●|●|●|●|●|●|●|●| | | |●|● 1407 - 1408 -**Features** 1409 - 1410 -The input value (BIN 32-bit value) specified in (s3) controls the output value stored in the device specified in (d) according to the upper and lower limits of the dead zone specified in (s1) and (s2). The output value is controlled as follows. 1411 - 1412 -|**Condition**|**The value stored in the output value** 1413 -|When dead zone low limit ((s1), (s1)+1)> input value ((s3), (s3)+1)|{{id name="OLE_LINK42"/}}Input value ((s3), (s3)+1)-dead zone low limit ((s1), (s1)+1) 1414 -|When dead zone high limit ((s1), (s1)+1) <input value ((s3), (s3)+1)|{{id name="OLE_LINK357"/}}Input value ((s3), (s3)+1)-dead zone high limit ((s2), (s2)+1) 1415 -|When dead zone low limit ((s1), (s1)+1) ≤ input value ((s3), (s3)+1) ≤ dead zone high limit ((s2), (s2)+1)|0 1416 - 1417 - 1418 -((( 1419 -• When the output value stored in (d) is a signed BIN 32-bit value, and the operation result exceeds the range of -2,147,483,648 to 2,147,483,647, the situation is as the following example. For example,** **When (s1) and (s1)+1 are 1000, (s3) and (s3)+1 are -2,147,483,648, then the output value= 1420 - 1421 --2,147,483,648-1000=80000000H-000003E8H=7FFFFC18H=2,147,482,648. 1422 - 1423 -[[image:07-5 Basic instructions_html_e0144674dad3e8fd.png]] 1424 - 1425 - 1426 - 1427 -))) 1428 - 1429 -**Error code** 1430 - 1431 -|**Error code**|**Content** 1432 -|4085H|When the specified device range for reading exceeds the range of the corresponding device. 1433 -|4086H|When the specified device range for writing exceeds the range of the corresponding device. 1434 -|4084H|When the low limit specified in (s1) is greater than the high limit specified in (s2). 1435 - 1436 -**Example** 1437 - 1438 -[[image:07-5 Basic instructions_html_88f3fe0fb4841bab.png]] 1439 - 1440 -• When (D1, D0)<(-10,000), the value of (D1, D0)-(-10,000) is stored in (D11, D10). 1441 - 1442 -• When -10,000≦(D1, D0)≦10,000, 0 is stored in (D11, D10). 1443 - 1444 -• When 10,000< (D1, D0), the value of (D1, D0)-10,000 is stored in D1. 1445 - 1446 -{{id name="_Toc21668"/}}{{id name="_Toc25056"/}}{{id name="_Toc17582"/}}{{id name="OLE_LINK165"/}}**BINDA/BIN 16-bit data → Decimal ASCII conversion** 1447 - 1448 -[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] **BINDA(P)** 1449 - 1450 -Convert the BIN 16-bit data specified in (s) and the value of each digit in decimal numbers into ASCII codes and store them after the device number specified in (d). 1451 - 1452 --[BINDA(s)(d)] 1453 - 1454 -**Content, range and data type** 1455 - 1456 -|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 1457 -|(s)|BIN data for ASCII conversion|-32768 to +32767|Signed BIN 16 bit|ANY16_S 1458 -|(d)|The start number of the device storing the conversion result|-|String|ANYSTRING_SINGLE 1459 - 1460 -**Device used** 1461 - 1462 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 1463 -**Pulse** 1464 - 1465 -**extension** 1466 -))) 1467 -|**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 1468 -|(% rowspan="2" %)BINDA|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | |●|●| |●|● 1469 -|Parameter 2| | | | | | | | | | | | | | | | |●|●|●| | | | | |●|● 1470 - 1471 -**Features** 1472 - 1473 -Convert the BIN 16-bit data specified in (s) and the value of each digit in decimal numbers into ASCII codes and store them after the device number specified in (d). 1474 - 1475 - 1476 - 1477 -((( 1478 -←Only store 0 when SM191 is OFF 1479 - 1480 -[[image:07-5 Basic instructions_html_57bda5f08026449d.png]] 1481 -))) 1482 - 1483 -For example, when -12,345 is specified in (s) (in the case of specifying signed) 1484 - 1485 -[[image:07-5 Basic instructions_html_f346102467b9bef9.png]] 1486 - 1487 -The calculation result stored in (d) will be as below. 1488 - 1489 -• In "Sign", 20H is stored when the BIN data is positive, and 2DH is stored when it is negative. 1490 - 1491 -• In the 0 to the left of the effective digit, 20H is stored. (Suppress 0.) For example, in the case of "00325", "00" becomes 20H, and "325" becomes the effective digit. 1492 - 1493 -• When storing data to the device specified in (d)+3, when SM191 (output character number switching signal) is OFF, 0 is stored, and it does not change when it is ON. 1494 - 1495 -✎**Note: **The number of occupied points of (d) is 3 when SM191 is ON, and it is 4 when SM191 is OFF. 1496 - 1497 -**Error code** 1498 - 1499 -|**Error code**|**Content** 1500 -|4085H|The read address of (s) exceeds the device range. 1501 -|4086H|The write address of (d) exceeds the device range. 1502 - 1503 -**Example** 1504 - 1505 - 1506 - 1507 -((( 1508 -When X000 is ON, convert the value of 16-bit data (BIN) D1000 into decimal ASCII code, and then use PR instruction to output the 1509 - 1510 -converted ASCII code character by character to the program of Y040 to Y057. 1511 - 1512 -[[image:07-5 Basic instructions_html_c598806a42484ed.png]] 1513 -))) 1514 - 1515 -{{id name="_Toc12255"/}}{{id name="_Toc8216"/}}{{id name="_Toc470"/}}**DBINDA/BIN 32-bit data → Decimal ASCII conversion** 1516 - 1517 -[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] **DBINDA(P)** 1518 - 1519 -Convert the BIN 32-bit data specified in (s) and the value of each bit in decimal numbers into ASCII codes and store them after the device number specified in (d). 1520 - 1521 --[DBINDA(s)(d)] 1522 - 1523 -**Content, range and data type** 1524 - 1525 -|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 1526 -|(s)|BIN data for ASCII conversion|-2,147483648 to 2147483647|Signed BIN 32 bit|ANY32_S 1527 -|(d)|{{id name="OLE_LINK2"/}}The start number of the device storing the conversion result|-|String|ANYSTRING_SINGLE 1528 - 1529 -**Device used** 1530 - 1531 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|((( 1532 -**Offset** 1533 - 1534 -**modification** 1535 -)))|((( 1536 -**Pulse** 1537 - 1538 -**extension** 1539 -))) 1540 -|**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 1541 -|(% rowspan="2" %)DBINDA|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●| |●|● 1542 -|Parameter 2| | | | | | | | | | | | | | | | |●|●|●| | | | | |●|● 1543 - 1544 -**Features** 1545 - 1546 -Convert the BIN 32-bit data specified in (s) and the value of each bit when expressed in decimal numbers into ASCII codes, and store them after the device number specified in (d). 1547 - 1548 -For example, when -12345678 is specified in (s). (in the case of specifying signed) 1549 - 1550 -[[image:07-5 Basic instructions_html_4d939462838cf09b.gif]] The calculation result stored in (d) will be as below. 1551 - 1552 -• In "Sign", 20H is stored when the BIN data is positive, and 2DH is stored when it is negative. 1553 - 1554 -• 20H is stored at 0 to the left of the effective number of digits. (Suppress 0.) For example, in the case of "0012034560", "00" becomes 20H, and "12034560" becomes effective digits. 1555 - 1556 -• For the data stored in the upper 8 bits of the device specified in (d)+5, 0 will be stored when SM191 (output character switching signal) is OFF, and 20H will be stored when it is ON. 1557 - 1558 -✎**Note: **(d) Occupies 6 points. 1559 - 1560 -**Error code** 1561 - 1562 -|**Error code**|**Content** 1563 -|4085H|(s) read address exceeds the device range 1564 -|4086H|(d) write address exceeds the device range 1565 - 1566 -**Example** 1567 - 1568 -[[image:07-5 Basic instructions_html_ec8ac32d748a991c.png]] 1569 - 1570 -When X000 is ON, convert the value of 32-bit data (BIN) D1000 into decimal ASCII code, and then use PR (FNC 77) instruction to output the converted ASCII code character by character to the program in Y040 to Y051 in time and time division. 1571 - 1572 -{{id name="_Toc19693"/}}{{id name="_Toc18078"/}}{{id name="_Toc5726"/}}**DABIN/Decimal ASCII → BIN conversion** 1573 - 1574 -[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] **DABIN(P)** 1575 - 1576 -Digital ASCII code (30H to 39H) is a instruction to convert real data into BIN data. 1577 - 1578 --[DABIN (s) (d)] 1579 - 1580 -**Content, range and data type** 1581 - 1582 -|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 1583 -|(s)|The start number of the device that stores the data (ASCII code) to be converted into a BIN value|-|String|ANYSTRING_SINGLE 1584 -|(d)|The device number for storing conversion result|-|BIN16 bit|ANY16_S 1585 - 1586 -**Device used** 1587 - 1588 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 1589 -**Pulse** 1590 - 1591 -**extension** 1592 -))) 1593 -|**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 1594 -|(% rowspan="2" %)DABIN|Parameter 1| | | | | | | | | | | | | | | | |●|●|●| | | | | |●|● 1595 -|Parameter 2| | | | | | | | | | | |●|●|●|●|●|●|●|●| | | | | |●|● 1596 - 1597 -**Features** 1598 - 1599 -The decimal ASCII data stored after the device number specified in (s) is converted into BIN 16-bit data and stored in the device specified in (d). 1600 - 1601 -[[image:07-5 Basic instructions_html_22c5cb32a0a32214.png]] 1602 - 1603 -|**ASCII S**|**ASCII 10^^0^^**|**ASCII 10^^1^^**|**ASCII 10^^2^^**|**ASCII 10^^3^^**|**ASCII 10^^4^^** 1604 -|**ASCII code**|((( 1605 -{{id name="OLE_LINK36"/}}Units of 1606 - 1607 -ASCII code 1608 -)))|((( 1609 -Tens of 1610 - 1611 -ASCII code 1612 -)))|((( 1613 -Hundreds of 1614 - 1615 -ASCII code 1616 -)))|((( 1617 -Thousands of 1618 - 1619 -ASCII code 1620 -)))|((( 1621 -Ten thousands 1622 - 1623 -of ASCII code 1624 -))) 1625 - 1626 -For example, When -25,108 is specified in (s) 1627 - 1628 -[[image:07-5 Basic instructions_html_10fb2792e37dbf23.png]] 1629 - 1630 -• The ASCII data specified in (s) to (s)+2 is within the range of -32,768 to +32,767. 1631 - 1632 -• In “Sign”, set 20H when the converted data is positive, and set 2DH when it is negative. (When other than 20H or 2DH is set, it will be treated as positive data. (DABIN(P)) 1633 - 1634 -• The range of the ASCII code set in each digit is 30H to 39H. 1635 - 1636 -• When the ASCII code set in each bit is 20H or 00H, it will be treated as 30H. 1637 - 1638 -**Error code** 1639 - 1640 -|**Error code**|**Content** 1641 -|4084H|((( 1642 -When the Sign data exceeds the range of 30H to 39H, 20H, 00H, 2DH; 1643 - 1644 -When the ASCII code of each bit specified in (s) to (s)+2 exceeds the range of 30H to 39H, 20H, 00H; 1645 - 1646 -When the ASCII data specified in (s) to (s)+2 is other than -32,768 to +32,767. 1647 -))) 1648 -|4085H|The read address of (s) exceeds the device range. 1649 -|4086H|The write address of (d) exceeds the device range. 1650 - 1651 - 1652 -((( 1653 -When X000 is ON, the Signs set in D20 to D22 and the ASCII code data of 5-digit decimal numbers are converted into BIN values, and then stored in the program of D0. 1654 - 1655 -**Example** 1656 -))) 1657 - 1658 -[[image:07-5 Basic instructions_html_bec2bea131b58c03.png]] 1659 - 1660 -{{id name="_Toc3351"/}}{{id name="_Toc26383"/}}{{id name="_Toc26233"/}}**DDABIN/Decimal ASCII → BIN32-bit data conversion** 1661 - 1662 -[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] **DDABIN(P)** 1663 - 1664 -The decimal ASCII data stored after the device number specified in (s) is converted into BIN 32-bit data and stored in the device number specified in (d). 1665 - 1666 --[DDABIN (s) (d) ] 1667 - 1668 -**Content, range and data type** 1669 - 1670 -|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 1671 -|(s)|The start number of the device that stores data (ASCII code) to be converted into a BIN value|-|String|ANYSTRING_SINGLE 1672 -|(d)|The device number for storing conversion result|-|Signed BIN 32 bit|ANY32_S 1673 - 1674 -**Device used** 1675 - 1676 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 1677 -**Pulse** 1678 - 1679 -**extension** 1680 -))) 1681 -|**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 1682 -|(% rowspan="2" %)DDABIN|Parameter 1| | | | | | | | | | | | | | | | |●|●|●| | | | | |●|● 1683 -|Parameter 2| | | | | | | | | | | |●|●|●|●|●|●|●|●|●|●| | | |●|● 1684 - 1685 -**Features** 1686 - 1687 -The decimal ASCII data stored after the device number specified in (s) is converted into BIN 32-bit data and stored in the device specified in (d). 1688 - 1689 -[[image:07-5 Basic instructions_html_c444110b273f33b7.gif]] 1690 - 1691 -|**ASCII S**|**ASCII code**|**ASCII S**|**ASCII code** 1692 -|ASCII 10^^0^^|Units of ASCII code|ASCII 10^^5^^|{{id name="OLE_LINK38"/}}Hundred thousands of ASCII code 1693 -|ASCII 10^^1^^|Tens of ASCII code|ASCII 10^^6^^|Millions of ASCII code 1694 -|ASCII 10^^2^^|Hundreds of ASCII code|ASCII 10^^7^^|Ten millions of ASCII code 1695 -|ASCII 10^^3^^|{{id name="OLE_LINK37"/}}Thousands of ASCII code|ASCII 10^^8^^|Hundred millions of ASCII code 1696 -|ASCII 10^^4^^|Tens thousands of ASCII code|ASCII 10^^9^^|billions of ASCII code 1697 - 1698 -When -1234543210 is specified in (s) (When signed is specified) 1699 - 1700 -[[image:07-5 Basic instructions_html_1b4c7e1c663a4399.png]] 1701 - 1702 -• The ASCII data specified in (s) to (s)+5 is within the range of -2,147,483,648 to +2,147,483,647. In addition, the data stored in the high byte of (s)+5 will be ignored. 1703 - 1704 -• In the Sign data, set 20H when the converted data is positive, and set 2DH when it is negative. (When other than 20H or 2DH is set, it will be treated as positive data. (DABIN(P)) 1705 - 1706 -• The range of ASCII code set in each digit is 30H to 39H. 1707 - 1708 -• When the ASCII code set in each bit is 20H or 00H, it will be treated as 30H. 1709 - 1710 -**Error code** 1711 - 1712 -|**Error code**|**Content** 1713 -|4084H|((( 1714 -When the Sign data exceeds the range of 30H to 39H, 20H, 00H and 2DH; 1715 - 1716 -{{id name="OLE_LINK39"/}}When the ASCII code of each bit specified in (s) to (s)+5 exceeds the range of 30H to 39H, 20H and 00H; 1717 - 1718 -When the ASCII data specified in (s) to (s)+5 exceeds the range of -2,147,483,648 to +2,147,483,647 1719 -))) 1720 -|4085H|The read address of (s) exceeds the device range. 1721 -|4086H|The write address of (d) exceeds the device range. 1722 - 1723 -**Example** 1724 - 1725 -[[image:07-5 Basic instructions_html_feea438c943ea9dd.png]] 1726 - 1727 -When X000 is ON, the Signs set in to D20 to D25 and the ASCII code data of 10-digit decimal numbers are converted into BIN values and then saved to the program in D0 to D1. 1728 - 1729 -{{id name="_Toc26556"/}}{{id name="_Toc12799"/}}{{id name="_Toc23863"/}}**LIMIT/ BIN 16-bit data high and low limit control** 1730 - 1731 -[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] **LIMIT(P)** 1732 - 1733 -The input value (BIN 16-bit value) specified in (s3) controls the output value stored in the device specified in (d) according to the upper and lower limit value ranges specified in (s1) and (s2). 1734 - 1735 --[LIMIT (s1) (s2) (s3) (d)] 1736 - 1737 -**Content, range and data type** 1738 - 1739 -|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 1740 -|s1|Low limit value (minimum output limit value)|-32,768 to 32,767|BIN16 bit|ANY16_S 1741 -|s2|High limit value (maximum output limit value)|-32,768 to 32,767|BIN16 bit|ANY16_S 1742 -|s3|Input value controlled by high and low limit control|-32,768 to 32,767|BIN16 bit|ANY16_S 1743 -|d|The start number of device that stores the output value controlled by high and low limit control|-|BIN16 bit|ANY16_S 1744 - 1745 -**Device used** 1746 - 1747 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 1748 -**Pulse** 1749 - 1750 -**extension** 1751 -))) 1752 -|**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 1753 -|(% rowspan="4" %)LIMIT|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | |●|●| |●|● 1754 -|Parameter 2| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | |●|●| |●|● 1755 -|Parameter 3| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | | | | |●|● 1756 -|Parameter 4| | | | | | | | | | | |●|●|●|●|●|●|●|●| | | | | |●|● 1757 - 1758 -**Features** 1759 - 1760 -The input value (BIN 16-bit value) specified in (s3) controls the output value stored in the device specified in (d) according to the high and low limit value ranges specified in (s1) and (s2). The output value is controlled as follows. 1761 - 1762 -|**Condition**|**The value stored in the output value** 1763 -|Low limit value (s1)>input value (s3)|Low limit value (s1) 1764 -|High limit value (s1) <input value (s3)|High limit value (s2) 1765 -|Low limit value (s1) ≤ input value (s3) ≤ high limit value (s2)|Input value (s3) 1766 - 1767 - 1768 -((( 1769 -•Only in the case of controlling high limit value, set the minimum value of data range in the low limit value specified in (s1). 1770 - 1771 -• Only in the case of controlling low limit value, set the maximum value of data range in the high limit value specified in (s2). 1772 - 1773 -[[image:07-5 Basic instructions_html_50eb5229b027aa14.png]] 1774 -))) 1775 - 1776 -**Error code** 1777 - 1778 -|**Error code**|**Content** 1779 -|4085H|The read address exceeds the device range 1780 -|4086H|The write address exceeds the device range 1781 -|4084H|High limit <low limit 1782 - 1783 -**Example** 1784 - 1785 -[[image:07-5 Basic instructions_html_d67a2e740d4fc738.png]] 1786 - 1787 -When X000 is ON 1788 - 1789 -• When D0 <500, D1 is 500. 1790 - 1791 -• When 500 ≤ D0 ≤ 5,000, D1 is the value of D0. 1792 - 1793 -• When 5,000 <D0, D1 is 5,000. 1794 - 1795 -{{id name="_Toc32553"/}}{{id name="_Toc9981"/}}{{id name="_Toc9158"/}}**DLIMIT/BIN 32-bit data high and low limit control** 1796 - 1797 -[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] **DLIMIT(P)** 1798 - 1799 -The input value (BIN 32-bit value) specified in (s3) controls the output value stored in the device specified in (d) according to the range of high and low limit values specified in (s1) and (s2). 1800 - 1801 --[DLIMIT (s1) (s2) (s3) (d)] 1802 - 1803 -**Content, range and data type** 1804 - 1805 -|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 1806 -|s1|Low limit value (minimum output limit value)|-2,147,483,648 to 2,147,483,647|BIN32 bit|ANY32_S 1807 -|s2|High limit value (maximum output limit value)|-2,147,483,648 to 2,147,483,647|BIN32 bit|ANY32_S 1808 -|s3|Input value controlled by high and low limit control|-2,147,483,648 to 2,147,483,647|BIN32 bit|ANY32_S 1809 -|d|The start number of the device that stores the output value controlled by high and low limit control|-|BIN32 bit|ANY32_S 1810 - 1811 -**Device used** 1812 - 1813 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 1814 -**Pulse** 1815 - 1816 -**extension** 1817 -))) 1818 -|**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 1819 -|(% rowspan="4" %)DLIMIT|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●| |●|● 1820 -|Parameter 2| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●| |●|● 1821 -|Parameter 3| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●| | | |●|● 1822 -|Parameter 4| | | | | | | | | | | |●|●|●|●|●|●|●|●|●|●| | | |●|● 1823 - 1824 -**Features** 1825 - 1826 -The input value (BIN 32-bit value) specified in (s3) controls the output value stored in the device specified in (d) according to the range of high and low limit values specified in (s1) and (s2). The output value is controlled as follows. 1827 - 1828 -|**Condition**|**The value stored in the output value** 1829 -|Low limit value ((s1), (s1)+1)> input value ((s3), (s3)+1)|Low limit value ((s1), (s1)+1) 1830 -|High limit value ((s2), (s2)+1) <input value ((s3), (s3)+1)|High limit value ((s2), (s2)+1) 1831 -|Low limit value ((s1), (s1)+1) ≤ input value ((s3), (s3)+1) ≤ high limit value ((s2), (s2)+1)|Input value ((s3), (s3)+1) 1832 - 1833 -{{id name="OLE_LINK43"/}}{{id name="OLE_LINK40"/}}•Only in the case of controlling high limit value, set the minimum value of data range in the low limit value specified in (s1). 1834 - 1835 -• Only in the case of controlling low limit value, set the maximum value of data range in the high limit value specified in (s2). 1836 - 1837 -**Error code** 1838 - 1839 -|**Error code**|**Content** 1840 -|4085H|The read address exceeds the device range 1841 -|4086H|The write address exceeds the device range 1842 -|4084H|High limit <low limit 1843 - 1844 -**Example** 1845 - 1846 -[[image:07-5 Basic instructions_html_217355b90f4b4e16.png]] 1847 - 1848 -Operation: 1849 - 1850 -• When (D1, D0) <10,000, (D11, D10) is 10,000. 1851 - 1852 -• When 10,000 ≤ (D1, D0) ≤ 1,000,000, (D11, D10) is the value of (D1, D0). 1853 - 1854 -• When 1,000,000 <(D1, D0), (D11, D10) is 1,000,000. 1855 - 1856 -{{id name="_Toc12534"/}}{{id name="_Toc28213"/}}{{id name="_Toc24591"/}}**SCL/BIN 16-bit unit scale (coordinate data of each point)** 1857 - 1858 -[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] **SCL(P)** 1859 - 1860 -The scaling conversion data (16-bit data unit) specified in (s2) is scaled from the input value specified in (s1), and the calculation result is stored in the device specified in (d). 1861 - 1862 --[SCL (s1) (s2) (d)] 1863 - 1864 -**Content, range and data type** 1865 - 1866 -|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 1867 -|(s1)|The input value for scaling or the start number of device storing the input value|-32,768 to 32,767|Signed BIN 16 bit|ANY16_S 1868 -|(s2)|The start number of the device storing conversion data for scaling|-|Signed BIN 16 bit|ANY16_S 1869 -|(d)|The start number of the device that stores the output value controlled by scaling|-|Signed BIN 16 bit|ANY16_S 1870 - 1871 -**Device used** 1872 - 1873 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 1874 -**Pulse** 1875 - 1876 -**extension** 1877 -))) 1878 -|**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 1879 -|(% rowspan="3" %)SCL|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | |●|●| |●|● 1880 -|Parameter 2| | | | | | | | | | | | | | | | |●|●|●| | | | | |●|● 1881 -|Parameter 3| | | | | | | | | | | |●|●|●|●|●|●|●|●| | | | | |●|● 1882 - 1883 -**Features** 1884 - 1885 -For the scale conversion data (16-bit data unit) specified in (s2), scale by the input value specified in (s1), and store the operation result in the device specified in (d). Scale conversion is performed based on the scale conversion data stored after the device specified in (s2). 1886 - 1887 -|(% colspan="2" %)**Setting items (n represents the number of coordinate points specified in (s2))**|**Device allocation** 1888 -|(% colspan="2" %)Coordinate points|(s2) 1889 -|(% rowspan="2" %)Point 1|X coordinate|(s2)+1 1890 -|Y coordinate|(s2)+2 1891 -|(% rowspan="2" %)Point 2|X coordinate|(s2)+3 1892 -|Y coordinate|(s2)+4 1893 -|(% colspan="3" %)........ 1894 -|(% rowspan="2" %)Point n|X coordinate|(s2)+2n-1 1895 -|Y coordinate|(s2)+2n 1896 - 1897 -[[image:07-5 Basic instructions_html_80185ccddb878234.png]] 1898 - 1899 -• If the operation result is not an integer value, round the first digit below the decimal point. 1900 - 1901 -• The X coordinate data of the conversion data for scaling should be set in ascending order. 1902 - 1903 -• (s1) should be set within the range of conversion data for scaling (device value of (s2)). 1904 - 1905 -• If the same X coordinate is specified for multiple points, the Y coordinate value of the second point will be output. 1906 - 1907 -• Set the number of coordinate points of the conversion data for scaling within the range of 1 to 32,767. 1908 - 1909 -• Setting example of conversion table for scaling. 1910 - 1911 -In the case of scaling conversion characteristics as shown in the figure below, set it as the following data sheet. 1912 - 1913 -[[image:07-5 Basic instructions_html_74fd22d845ad450e.png]] 1914 - 1915 -|(% colspan="2" rowspan="2" %)**Set items**|(% colspan="3" %)**Sett device and content**|(% rowspan="2" %)**Remarks** 1916 -|(% colspan="2" %)**When R0 is specified in (s2)**|**Set content** 1917 -|(% colspan="2" %)Coordinate points|(s2)|R0|K10| 1918 -|(% rowspan="2" %)Point 1|X coordinate|(s2)+1|R1|K5| 1919 -|Y coordinate|(s2)+2|R2|K20| 1920 -|(% rowspan="2" %)Point 2|X coordinate|(s2)+3|R3|K30| 1921 -|Y coordinate|(s2)+4|R4|K50| 1922 -|(% rowspan="2" %)Point 3|X coordinate|(s2)+5|R5|K100| 1923 -|Y coordinate|(s2)+6|R6|K200| 1924 -|(% rowspan="2" %)Point 4|X coordinate|(s2)+7|R7|K25|(% rowspan="6" %)((( 1925 -If the coordinates are specified by 3 points, the intermediate value could be the output value. 1926 - 1927 -In this example, the output value (median value) is specified by the Y coordinate of point 5. 1928 - 1929 -When the X coordinate is the same at 3 points or more, the value of the 2nd point is also output. 1930 -))) 1931 -|Y coordinate|(s2)+8|R8|K200 1932 -|(% rowspan="2" %)Point 5|X coordinate|(s2)+9|R9|K70 1933 -|Y coordinate|(s2)+10|R10|K200 1934 -|(% rowspan="2" %)Point 6|X coordinate|(s2)+11|R11|K250 1935 -|Y coordinate|(s2)+12|R12|K250 1936 -|(% rowspan="2" %)Point 7|X coordinate|(s2)+13|R13|K250| 1937 -|Y coordinate|(s2)+14|R14|K90| 1938 -|(% rowspan="2" %)Point 8|X coordinate|(s2)+15|R15|K350|(% rowspan="4" %)((( 1939 -If the coordinates are specified by two points, the output value is the value of the Y coordinate of the next point. 1940 - 1941 -In this example, the output value is specified by the Y coordinate of point 9. 1942 -))) 1943 -|Y coordinate|(s2)+16|R16|K90 1944 -|(% rowspan="2" %)Point 9|X coordinate|(s2)+17|R17|K350 1945 -|Y coordinate|(s2)+18|R18|K30 1946 -|(% rowspan="2" %)Point 10|X coordinate|(s2)+19|R19|K400| 1947 -|Y coordinate|(s2)+20|R20|K7| 1948 - 1949 -**Error code** 1950 - 1951 -|**Error code**|**Content** 1952 -|4085H|When the specified device range for reading exceeds the range of the corresponding device. 1953 -|4086H|When the specified device range for writing exceeds the range of the corresponding device. 1954 -|4084H|((( 1955 -When the Xn data of data table is not sorted in ascending order. However, the instruction will be executed until the position where the error occurs; 1956 - 1957 -When the input value specified in (s1) exceeds the range of the set scale conversion data; 1958 - 1959 -When the number of start coordinate points of device (s2) is less than 0. 1960 -))) 1961 - 1962 -**Example** 1963 - 1964 -[[image:07-5 Basic instructions_html_5519d7b41f15b6d6.png]] 1965 - 1966 -[[image:07-5 Basic instructions_html_ace075fb7675de8e.gif]] When -100 ≤ D0(X) < 0, D100(Y)= 1967 - 1968 -[[image:07-5 Basic instructions_html_9acd6306c6d91847.gif]] when D0(X)=0, D100(Y)=0; 1969 - 1970 -when 0< D0(X) ≤ 100, D100(Y)= 1971 - 1972 -[[image:07-5 Basic instructions_html_e35e13160c08a133.png]] 1973 - 1974 - 1975 - 1976 -{{id name="_Toc4862"/}}{{id name="_Toc11340"/}}{{id name="_Toc25383"/}}**DSCL/32-bit unit scale (coordinate data of each point)** 1977 - 1978 -[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] **DSCL(P)** 1979 - 1980 -The conversion data (32-bit data unit) for scaling specified in (s2) is scaled by the input value specified in (s1), and the operation result is stored in the device specified in (d). 1981 - 1982 --[DSCL (s1) (s2) (d)] 1983 - 1984 -**Content, range and data type** 1985 - 1986 -|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 1987 -|(s1)|The input value for scaling or the start number of the device storing the input value|-2,147,483,648 to 2,147,483,647|Signed BIN 32 bit|ANY32_S 1988 -|(s2)|The start number of the device storing conversion data for scaling|-|Signed BIN 32 bit|ANY32_S 1989 -|(d)|The start number of the device that stores the output value controlled by scaling|-|Signed BIN 32 bit|ANY32_S 1990 - 1991 -**Device used** 1992 - 1993 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Device**|**Offset modification**|((( 1994 -**Pulse** 1995 - 1996 -**extension** 1997 -))) 1998 -|**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 1999 -|(% rowspan="3" %)DSCL|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●| |●|● 2000 -|Parameter 2| | | | | | | | | | | | | | | | |●|●|●| | | | | |●|● 2001 -|Parameter 3| | | | | | | | | | | |●|●|●|●|●|●|●|●|●|●| | | |●|● 2002 - 2003 -**Features** 2004 - 2005 -{{id name="OLE_LINK41"/}}The conversion data (32-bit data unit) for scaling specified in (s2) is scaled by the input value specified in (s1), and the operation result is stored in the device number specified in (d). The scale conversion is performed based on the scale conversion data stored after the device specified in (s2). 2006 - 2007 -|(% colspan="2" %)**Set items (n represents the number of coordinate points specified in (s2))**|**Device allocation** 2008 -|(% colspan="2" %)Coordinate points|(s2)+1, (s2) 2009 -|(% rowspan="2" %)Point 1|X coordinate|(s2)+3, (s2)+2 2010 -|Y coordinate|(s2)+5, (s2)+4 2011 -|(% rowspan="2" %)Point 2|X coordinate|(s2)+7, (s2)+6 2012 -|Y coordinate|(s2)+9, (s2)+8 2013 -|(% colspan="3" %)........ 2014 -|(% rowspan="2" %)Point n|X coordinate|(s2)+4n-1, (s2)+4n-2 2015 -|Y coordinate|(s2)+4n+1, (s2)+4n 2016 - 2017 -[[image:07-5 Basic instructions_html_6633ca18cee1218c.png]] 2018 - 2019 -• If the calculation result is not an integer value, round the first digit below the decimal point. 2020 - 2021 -• The X coordinate data of the conversion data for scaling should be set in ascending order. 2022 - 2023 -• For (s1), set within the range of the conversion data for scaling ((s2), (s2) + 1 device value). 2024 - 2025 -• If the same X coordinate is specified for multiple points, the Y coordinate value of the second point will be output. 2026 - 2027 -• Set the number of coordinate points of conversion data for scaling within the range of 1 to 2,147,483,647. 2028 - 2029 -• Setting example of conversion table for scaling. 2030 - 2031 -In the case of scaling conversion characteristics as shown in the figure below, set it as the following data sheet. 2032 - 2033 -[[image:07-5 Basic instructions_html_74fd22d845ad450e.png]] 2034 - 2035 -|(% colspan="2" rowspan="2" %)**Set items**|(% colspan="3" %)**Set device and content**|(% rowspan="2" %)**Remarks** 2036 -|(% colspan="2" %)**When R0 is specified in (s2)**|**Set content** 2037 -|(% colspan="2" %)Coordinate points|(s2)+1, (s2)|R1, R0|K10| 2038 -|(% rowspan="2" %)Point 1|X coordinate|(s2)+3, (s2)+2|R3, R2|K5| 2039 -|Y coordinate|(s2)+5, (s2)+4|R5, R4|K7| 2040 -|(% rowspan="2" %)Point 2|X coordinate|(s2)+7, (s2)+6|R7, R6|K20| 2041 -|Y coordinate|(s2)+9, (s2)+8|R9, R8|K30| 2042 -|(% rowspan="2" %)Point 3|X coordinate|(s2)+11, (s2)+10|R10, R11|K50| 2043 -|Y coordinate|(s2)+13, (s2)+12|R13, R12|K100| 2044 -|(% rowspan="2" %)Point 4|X coordinate|(s2)+15, (s2)+14|R15, R14|K200|(% rowspan="6" %)((( 2045 -if the coordinates are specified by 3 points, the intermediate value could be the output value. 2046 - 2047 -In this example, the output value (median value) is specified by the Y coordinate of point 5. 2048 - 2049 -When the X coordinate is the same at 3 points or more, the value of the 2nd point is also output. 2050 -))) 2051 -|Y coordinate|(s2)+17, (s2)+16|R17, R16|K25 2052 -|(% rowspan="2" %)Point 5|X coordinate|(s2)+19, (s2)+18|R19, R18|K200 2053 -|Y coordinate|(s2)+21, (s2)+20|R21, R20|K70 2054 -|(% rowspan="2" %)Point 6|X coordinate|(s2)+23, (s2)+22|R23, R22|K200 2055 -|Y coordinate|(s2)+25, (s2)+24|R25, R24|K250 2056 -|(% rowspan="2" %)Point 7|X coordinate|(s2)+27, (s2)+26|R27, R26|K250| 2057 -|Y coordinate|(s2)+29, (s2)+28|R29, R28|K90| 2058 -|(% rowspan="2" %)Point 8|X coordinate|(s2)+31, (s2)+30|R31, R30|K350|(% rowspan="4" %)((( 2059 -If the coordinates are specified by two points, the output value is the value of the Y coordinate of the next point. 2060 - 2061 -In this example, the output value is specified by the Y coordinate of point 9. 2062 -))) 2063 -|Y coordinate|(s2)+33, (s2)+32|R33, R32|K90 2064 -|(% rowspan="2" %)Point 9|X coordinate|(s2)+35, (s2)+34|R35, R34|K350 2065 -|Y coordinate|(s2)+37, (s2)+36|R37, R36|K30 2066 -|(% rowspan="2" %)Point 10|X coordinate|(s2)+39, (s2)+38|R39, R38|K400| 2067 -|Y coordinate|(s2)+41, (s2)+40|R41, R40|K7| 2068 - 2069 -**Error code** 2070 - 2071 -|**Error code**|**Content** 2072 -|4085H|When the specified device range for reading exceeds the range of the corresponding device. 2073 -|4086H|When the specified device range for writing exceeds the range of the corresponding device. 2074 -|4084H|((( 2075 -When the Xn data of data table is not sorted in ascending order. However, the instruction will be executed until the position where the error occurs; 2076 - 2077 -When the input value specified in (s1) exceeds the range of the set scale conversion data; 2078 - 2079 -When the number of start coordinate points of device (s2) is less than 0. 2080 -))) 2081 - 2082 -**Example** 2083 - 2084 -[[image:07-5 Basic instructions_html_ba95b2d50d8d1d3e.png]] 2085 - 2086 -[[image:07-5 Basic instructions_html_1de79c7d87d51f78.gif]] When -100 ≤ D0(X) < 0, D100(Y)= 2087 - 2088 -[[image:07-5 Basic instructions_html_9acd6306c6d91847.gif]] When D0(X)=0, D100(Y)=0; 2089 - 2090 -When 0 < D0(X) ≤ 100, D100(Y)= 2091 - 2092 -[[image:07-5 Basic instructions_html_a5b19d1af74a9620.png]] 2093 - 2094 -{{id name="_Toc3776"/}}{{id name="_Toc11170"/}}{{id name="_Toc2957"/}}**SCL2/BIN 16-bit unit scale (X/Y coordinate data)** 2095 - 2096 -[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] **SCL2(P)** 2097 - 2098 -The conversion data (16-bit data unit) for scaling specified in (s2) is scaled by the input value specified in (s1), and the operation result is stored in the device specified in (d). 2099 - 2100 --[SCL2 (s1) (s2) (d)] 2101 - 2102 -**Content, range and data type** 2103 - 2104 -|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 2105 -|(s1)|The input value for scaling or the start number of the device storing the input value|-32,768 to 32,767|Signed BIN 16 bit|ANY16_S 2106 -|(s2)|The start number of the device storing conversion data for scaling|-|Signed BIN 16 bit|ANY16_S 2107 -|(d)|The start number of the device that stores the output value controlled by scaling|-|Signed BIN 16 bit|ANY16_S 2108 - 2109 -**Device used** 2110 - 2111 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 2112 -**Pulse** 2113 - 2114 -**extension** 2115 -))) 2116 -|**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 2117 -|(% rowspan="3" %)SCL2|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | |●|●| |●|● 2118 -|Parameter 2| | | | | | | | | | | | | | | | |●|●|●| | | | | |●|● 2119 -|Parameter 3| | | | | | | | | | | |●|●|●|●|●|●|●|●| | | | | |●|● 2120 - 2121 -**Features** 2122 - 2123 -The conversion data (16-bit data unit) for scaling specified in (s2) is scaled by the input value specified in (s1), and the operation result is stored in the device number specified in (d). The scale conversion is performed based on the scale conversion data stored after the device specified in (s2). 2124 - 2125 -|(% colspan="2" %)**Set items (n represents the number of coordinate points specified in (s2))**|**Device allocation** 2126 -|(% colspan="2" %)Coordinate points|(s2) 2127 -|(% rowspan="4" %)X coordinate|Point 1|(s2)+1 2128 -|Point 2|(s2)+2 2129 -|.....|...... 2130 -|Point n|(s2)+n 2131 -|(% rowspan="4" %)Y coordinate|Point 1|(s2)+n+1 2132 -|Point 2|(s2)+n+2 2133 -|.....|..... 2134 -|Point n|(s2)+2n 2135 - 2136 -[[image:07-5 Basic instructions_html_80185ccddb878234.png]] 2137 - 2138 -• If the operation result is not an integer value, round the first digit below the decimal point. 2139 - 2140 -• The X coordinate data of the conversion data for scaling should be set in ascending order. 2141 - 2142 -• For (s1), set within the range of the conversion data for scaling ((s2), (s2) + 1 device value). 2143 - 2144 -• If the same X coordinate is specified for multiple points, the Y coordinate value of the second point will be output. 2145 - 2146 -• Set the number of coordinate points of conversion data for scaling within the range of 1 to 32,767. 2147 - 2148 -• Setting example of conversion table for scaling. 2149 - 2150 -In the case of scaling conversion characteristics as shown in the figure below, set it as the following data sheet. 2151 - 2152 -[[image:07-5 Basic instructions_html_74fd22d845ad450e.png]] 2153 - 2154 -|(% colspan="2" rowspan="2" %)**Set items**|(% colspan="3" %)**Set device and content**|(% rowspan="2" %)**Remarks** 2155 -|(% colspan="2" %)**When R0 is specified in (s2)**|**Set content** 2156 -|(% colspan="2" %)Coordinate points|(s2)|R0|K10| 2157 -|(% rowspan="10" %)X coordinate|Point 1|(s2)+1|R1|K5| 2158 -|Point 2|(s2)+2|R2|K20| 2159 -|Point 3|(s2)+3|R3|K50| 2160 -|Point 4|(s2)+4|R4|K200|(% rowspan="3" %)Refer to** ✎1** 2161 -|Point 5|(s2)+5|R5|K200 2162 -|Point 6|(s2)+6|R6|K200 2163 -|Point 7|(s2)+7|R7|K250| 2164 -|Point 8|(s2)+8|R8|K350|(% rowspan="2" %)Refer to** ✎2** 2165 -|Point 9|(s2)+9|R9|K350 2166 -|Point 10|(s2)+10|R10|K400| 2167 -|(% rowspan="10" %)Y coordinate|Point 1|(s2)+11|R11|K7| 2168 -|Point 2|(s2)+12|R12|K30| 2169 -|Point 3|(s2)+13|R13|K100| 2170 -|Point 4|(s2)+14|R14|K25|(% rowspan="3" %)Refer to**✎1** 2171 -|Point 5|(s2)+15|R15|K70 2172 -|Point 6|(s2)+16|R16|K250 2173 -|Point 7|(s2)+17|R17|K90| 2174 -|Point 8|(s2)+18|R18|K90|(% rowspan="2" %)Refer to** ✎2** 2175 -|Point 9|(s2)+19|R19|K30 2176 -|Point 10|(s2)+20|R20|K7| 2177 - 2178 -✎**1** Like points 4, 5, and 6, if the coordinates are specified by 3 points, the intermediate value could be the output value. 2179 - 2180 -In this example, the output value (median value) is specified by the Y coordinate of point 5. 2181 - 2182 -When the X coordinate is the same at 3 or more points, the value of the second point is also output. 2183 - 2184 -✎**2** Like points 8 and 9, if the coordinates are specified by 2 points, the output value is the value of the Y coordinate of next point. 2185 - 2186 -In this example, the output value is specified by the Y coordinate of point 9. 2187 - 2188 -**Error code** 2189 - 2190 -|**Error code**|**Content** 2191 -|4085H|When the specified device range for reading exceeds the range of the corresponding device. 2192 -|4086H|When the specified device range for writing exceeds the range of the corresponding device. 2193 -|4084H|((( 2194 -When the Xn data of data table is not sorted in ascending order. However, the instruction will be executed until the position where the error occurs; 2195 - 2196 -When the input value specified in (s1) exceeds the range of the set scale conversion data; 2197 - 2198 -When the number of start coordinate points of device (s2) is less than 0. 2199 -))) 2200 - 2201 -**Example** 2202 - 2203 -[[image:07-5 Basic instructions_html_ace075fb7675de8e.gif]] [[image:07-5 Basic instructions_html_de529c9a16a62ef0.png]] 2204 - 2205 -When -100 ≤D0 (X) < 0, D100(Y)= 2206 - 2207 -[[image:07-5 Basic instructions_html_9acd6306c6d91847.gif]] when D0(X)=0, D100(Y)=0; 2208 - 2209 -when 0 < D0(X) ≤ 100, D100(Y)= 2210 - 2211 -[[image:07-5 Basic instructions_html_a5b19d1af74a9620.png]] 2212 - 2213 -{{id name="_Toc5608"/}}{{id name="_Toc1756"/}}{{id name="_Toc21402"/}}**DSCL2/BIN 32-bit unit scale (X/Y coordinate data)** 2214 - 2215 -[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] **DSCL2(P)** 2216 - 2217 -The conversion data (32-bit data unit) for scaling specified in (s2) is scaled by the input value specified in (s1), and the operation result is stored in the device specified in (d). 2218 - 2219 --[DSCL2 (s1) (s2) (d)] 2220 - 2221 -**Content, range and data type** 2222 - 2223 -|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 2224 -|(s1)|The input value for scaling or the start number of the device storing the input value|-2,147,483,648 to +2,147,483,647|Signed BIN 32 bit|ANY32_S 2225 -|(s2)|The start number of the device storing conversion data for scaling|-|Signed BIN 32 bit|ANY32_S 2226 -|(d)|The start number of the device that stores the output value controlled by scaling|-|Signed BIN 32 bit|ANY32_S 2227 - 2228 -**Device used** 2229 - 2230 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 2231 -**Pulse** 2232 - 2233 -**extension** 2234 -))) 2235 -|**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 2236 -|(% rowspan="3" %)DSCL2|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●| |●|● 2237 -|Parameter 2| | | | | | | | | | | | | | | | |●|●|●| | | | | |●|● 2238 -|Parameter 3| | | | | | | | | | | |●|●|●|●|●|●|●|●|●|●| | | |●|● 2239 - 2240 -**Features** 2241 - 2242 -The conversion data (32-bit data unit) for scaling specified in (s2) is scaled by the input value specified in (s1), and the operation result is stored in the device number specified in (d). The scale conversion is performed based on the scale conversion data stored after the device specified in (s2). 2243 - 2244 -|(% colspan="2" %)**Set items (n represents the number of coordinate points specified in (s2))**|**Device allocation** 2245 -|(% colspan="2" %)Coordinate points|(s2)+1, (s2) 2246 -|(% rowspan="4" %)X coordinate|Point 1|(s2)+3, (s2)+2 2247 -|Point 2|(s2)+5, (s2)+4 2248 -|.....|...... 2249 -|Point n|(s2)+2n+1, (s2)+2n 2250 -|(% rowspan="4" %)Y coordinate|Point 1|(s2)+2n+3, (s2)+2n+2 2251 -|Point 2|(s2)+2n+5, (s2)+2n+4 2252 -|.....|..... 2253 -|Point n|(s2)+4n+1, (s2)+4n 2254 - 2255 -[[image:07-5 Basic instructions_html_6633ca18cee1218c.png]] 2256 - 2257 -• If the operation result is not an integer value, round the first digit below the decimal point. 2258 - 2259 -• The X coordinate data of the conversion data for scaling should be set in ascending order. 2260 - 2261 -• For (s1), set within the range of the conversion data for scaling ((s2), (s2) + 1 device value). 2262 - 2263 -• If the same X coordinate is specified for multiple points, the Y coordinate value of the second point will be output. 2264 - 2265 -• Set the number of coordinate points of conversion data for scaling within the range of 1 to 2,147,483,647. 2266 - 2267 -• Setting example of conversion table for scaling. 2268 - 2269 -In the case of scaling conversion characteristics as shown in the figure below, set it as the following data sheet. 2270 - 2271 -[[image:07-5 Basic instructions_html_74fd22d845ad450e.png]] 2272 - 2273 -|(% colspan="2" rowspan="2" %)**Set items**|(% colspan="3" %)**Set device and content**|(% rowspan="2" %)**Remarks** 2274 -|(% colspan="2" %)**When R0 is specified in (s2)**|**Set content** 2275 -|(% colspan="2" %)Coordinate points|(s2)+1, (s2)|R1, R0|K10| 2276 -|(% rowspan="10" %)X|Point 1|(s2)+3, (s2)+2|R3, R2|K5| 2277 -|Point 2|(s2)+5, (s2)+4|R5, R4|K20| 2278 -|Point 3|(s2)+7, (s2)+6|R7, R6|K50| 2279 -|Point 4|(s2)+9, (s2)+8|R9, R8|K200|(% rowspan="3" %)Refer to** ✎1** 2280 -|Point 5|(s2)+11, (s2)+10|R10, R11|K200 2281 -|Point 6|(s2)+13, (s2)+12|R13, R12|K200 2282 -|Point 7|(s2)+15, (s2)+14|R15, R14|K250| 2283 -|Point 8|(s2)+17, (s2)+16|R17, R16|K350|(% rowspan="2" %)Refer to** ✎2** 2284 -|Point 9|(s2)+19, (s2)+18|R19, R18|K350 2285 -|Point 10|(s2)+21, (s2)+20|R21, R20|K400| 2286 -|(% rowspan="10" %)Y coordinate|Point 1|(s2)+23, (s2)+22|R23, R22|K7| 2287 -|Point 2|(s2)+25, (s2)+24|R25, R24|K30| 2288 -|Point 3|(s2)+27, (s2)+26|R27, R26|K100| 2289 -|Point 4|(s2)+29, (s2)+28|R29, R28|K25|(% rowspan="3" %)Refer to** ✎1** 2290 -|Point 5|(s2)+31, (s2)+30|R31, R30|K70 2291 -|Point 6|(s2)+33, (s2)+32|R33, R32|K250 2292 -|Point 7|(s2)+35, (s2)+34|R35, R34|K90| 2293 -|Point 8|(s2)+37, (s2)+36|R37, R36|K90|(% rowspan="2" %)Refer to** ✎2** 2294 -|Point 9|(s2)+39, (s2)+38|R39, R38|K30 2295 -|Point 10|(s2)+41, (s2)+40|R41, R40|K7| 2296 - 2297 -✎**1** Like points 4, 5, and 6, if the coordinates are specified by 3 points, the intermediate value could be the output value. 2298 - 2299 -In this example, the output value (median value) is specified by the Y coordinate of point 5. 2300 - 2301 -When the X coordinate is the same at 3 or more points, the value of the second point is also output. 2302 - 2303 -✎**2** Like points 8 and 9, if the coordinates are specified by 2 points, the output value is the value of the Y coordinate of the next point. 2304 - 2305 -In this example, the output value is specified by the Y coordinate of point 9. 2306 - 2307 -**Error code** 2308 - 2309 -|**Error code**|**Content** 2310 -|4085H|When the specified device range for reading exceeds the range of the corresponding device. 2311 -|4086H|When the specified device range for writing exceeds the range of the corresponding device. 2312 -|4084H|((( 2313 -When the Xn data of data table is not sorted in ascending order. However, the instruction will be executed until the position where the error occurs; 2314 - 2315 -When the input value specified in (s1) exceeds the range of the set scale conversion data; 2316 - 2317 -When the number of start coordinate points of device (s2) is less than 0. 2318 -))) 2319 - 2320 -**Example** 2321 - 2322 -[[image:07-5 Basic instructions_html_91dbc16faa9d2ec3.png]] 2323 - 2324 -When -100 ≤D0(X) < 0, D100(Y)=[[image:/xwiki/bin/download/PLC%20Editor2/1%20User%20manual/2.1%20LX5V%20user%20manual/07-5%20Basic%20instruction/WebHome/07-5%20Basic%20instructions_html_2c96d630f666e72c.gif?rev=1.1||alt="07-5 Basic instructions_html_2c96d630f666e72c.gif"]],,[[image:07-5 Basic instructions_html_2c96d630f666e72c.gif]] ,,; 2325 - 2326 -when D0(X)=0, D100(Y)=0; 2327 - 2328 -when 0< D0(X) ≤ 100, D100(Y)=[[image:/xwiki/bin/download/PLC%20Editor2/1%20User%20manual/2.1%20LX5V%20user%20manual/07-5%20Basic%20instruction/WebHome/07-5%20Basic%20instructions_html_47ebf5cc7733fccc.gif?rev=1.1||alt="07-5 Basic instructions_html_47ebf5cc7733fccc.gif"]],,[[image:07-5 Basic instructions_html_47ebf5cc7733fccc.gif]] ,,. 2329 - 2330 -[[image:07-5 Basic instructions_html_a5b19d1af74a9620.png]] 2331 - 2332 -{{id name="_Toc32057"/}}{{id name="_Toc9941"/}}{{id name="_Toc6492"/}}**ZONE/BIN 16-bit data zone control** 2333 - 2334 -[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] **ZONE(P)** 2335 - 2336 -After adding the offset value specified in (s1) or (s2) to the input value specified in (s3), it is stored in the device number specified in (d). 2337 - 2338 --[ZONE (s1) (s2) (s3) (d)] 2339 - 2340 -**Content, range and data type** 2341 - 2342 -|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 2343 -|s1|The negative offset value for addition in the input value|-32,768 to 32,767|BIN16 bit|ANY16_S 2344 -|s2|The positive offset value for addition in the input value|-32,768 to 32,767|BIN16 bit|ANY16_S 2345 -|s3|Input value for zone control`|-32,768 to 32,767|BIN16 bit|ANY16_S 2346 -|d|The start number of the device storing the output value controlled by zone control|-|BIN16 bit|ANY16_S 2347 - 2348 -**Device used** 2349 - 2350 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 2351 -**Pulse** 2352 - 2353 -**extension** 2354 -))) 2355 -|**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 2356 -|(% rowspan="4" %)ZONE|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | |●|●| |●|● 2357 -|Parameter 2| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | |●|●| |●|● 2358 -|Parameter 3| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | | | | |●|● 2359 -|Parameter 4| | | | | | | | | | | |●|●|●|●|●|●|●|●| | | | | |●|● 2360 - 2361 -**Features** 2362 - 2363 -After adding the offset value specified in (s1) or (s2) to the input value (BIN 16-bit value) specified in (s3), it is stored in the device number specified in (d). The offset value is controlled as follows. 2364 - 2365 -|**Condition**|**The value stored in the output value** 2366 -|When input value (s3)<0|Input value (s3) + negative offset value (s1) 2367 -|When input value (s3)=0|0 2368 -|When input value (s3)>0|Input value (s3) + positive offset value (s2) 2369 - 2370 - 2371 -((( 2372 -• When the output value stored in (d) is a signed BIN 16-bit value, and the operation result exceeds the range of -32,768 to 32,767, the situation is shown in the following example. 2373 - 2374 -For example, when (s1) is -100 and (s3) is -32,768, 2375 - 2376 -the output value = -32768+(-100)=8000H-FF9CH=7F9CH=32668. 2377 - 2378 -[[image:07-5 Basic instructions_html_a2adbf9ccf8f839.png]] 2379 - 2380 - 2381 - 2382 -))) 2383 - 2384 -**Error code** 2385 - 2386 -|**Error code**|**Content** 2387 -|4085H|When the specified device range for reading exceeds the range of the corresponding device 2388 -|4086H|When the specified device range for writing exceeds the range of the corresponding device 2389 - 2390 -**Example** 2391 - 2392 -[[image:07-5 Basic instructions_html_5da523c7765bf5be.png]] 2393 - 2394 -When X000 is ON 2395 - 2396 -• When D0<0, the value of (D0)+(-1,000) is stored in D1. 2397 - 2398 -• When D0=0, 0 is stored in D1. 2399 - 2400 -• When 0<D0, the value of (D0)+(1,000) is stored in D1. 2401 - 2402 -{{id name="_Toc28351"/}}{{id name="_Toc11023"/}}{{id name="_Toc30269"/}}**DZONE/BIN 32-bit data zone control** 2403 - 2404 -[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] DZONE(P) 2405 - 2406 -After adding the offset value specified in (s1) or (s2) to the input value specified in (s3), it is stored in the device number specified in (d). 2407 - 2408 --[DZONE (s1) (s2) (s3) (d)] 2409 - 2410 -**Content, range and data type** 2411 - 2412 -|**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 2413 -|(s1)|The negative offset value for addition in the input value|-2147483648 to 2147483647|BIN32 bit|ANY32_S 2414 -|(s2)|The positive offset value for addition in the input value|-2147483648 to 2147483647|BIN32 bit|ANY32_S 2415 -|(s3)|Input value for zone control|-2147483648 to 2147483647|BIN32 bit|ANY32_S 2416 -|(d)|The start number of the device storing the output value controlled by zone control|-|BIN32 bit|ANY32_S 2417 - 2418 -**Device used** 2419 - 2420 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 2421 -**Pulse** 2422 - 2423 -**extension** 2424 -))) 2425 -|**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 2426 -|(% rowspan="4" %)DZONE|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●| |●|● 2427 -|Parameter 2| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●| |●|● 2428 -|Parameter 3| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●| | | |●|● 2429 -|Parameter 4| | | | | | | | | | | |●|●|●|●|●|●|●|●|●|●| | | |●|● 2430 - 2431 -**Features** 2432 - 2433 -After adding the offset value specified in (s1) or (s2) to the input value (BIN 32-bit value) specified in (s3), it is stored in the device number specified in (d). The offset value is controlled as follows. 2434 - 2435 -|**Condition**|**The value stored in the output value** 2436 -|When input value ((s3), (s3)+1)<0|Input value ((s3), (s3)+1) + negative offset value (s1), (s1)+1 2437 -|When input value ((s3), (s3)+1)=0|0 2438 -|When input value ((s3), (s3)+1)>0|Input value ((s3), (s3)+1) + positive offset value (s2), (s2)+1 2439 - 2440 - 2441 -((( 2442 -• When the output value stored in (d) and (d)+1 is a signed BIN 32-bit value, and the operation result exceeds the range of -2,147,483,648 to 2,147,483,647, the situation is shown in the following example. 2443 - 2444 -For example, (s1), (s1)+1 is -1,000, (s3), (s3)+1 is -2,147,483,648, then the output value=-2,147,483,648+(-1000)=80000000H+FFFFFC18H=2,147,482,648. 2445 - 2446 -[[image:07-5 Basic instructions_html_2f3a96a2565c75c7.png]] 2447 -))) 2448 - 2449 -**Error code** 2450 - 2451 -|**Error code**|**Content** 2452 -|4085H|When the specified device range for reading exceeds the range of the corresponding device 2453 -|4086H|When the specified device range for writing exceeds the range of the corresponding device 2454 - 2455 -**Example** 2456 - 2457 -[[image:07-5 Basic instructions_html_b831b14748df07ab.png]] 2458 - 2459 -• When (D1, D0)<0, the value of (D1, D0)+(-10,000) is stored in (D11, D10). 2460 - 2461 -• When (D1, D0)=0, 0 is stored in (D11, D10). 2462 - 2463 -• When 0<(D1, D0), the value of (D1, D0)+10,000 is stored in (D11, D10). 903 +(% style="text-align:center" %) 904 +[[image:07-5 Basic instructions_html_f512f36261705953.png||height="48" width="218"]]