Changes for page 12 Clock operation
Last modified by Mora Zhou on 2023/11/21 17:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -412,34 +412,35 @@ 412 412 413 413 **Device used** 414 414 415 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="5" %)**Devices**|((( 416 -**Offset modification** 415 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="10" %)**Devices**|((( 416 +**Offset** 417 + 418 +**modification** 417 417 )))|((( 418 -**Pulse extension** 420 +**Pulse** 421 + 422 +**extension** 419 419 ))) 420 -|**T**|**C**|**D**|**R**|**SD**|**[D]**|**XXP** 421 -|(% rowspan="3" %)TADD|Parameter 1|●|●|●|●|●|●|● 422 -|Parameter 2|●|●|●|●|●|●|● 423 -|Parameter 3|●|●|●|●|●|●|● 424 +|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 425 +|(% rowspan="3" %)TADD|Parameter 1|●|●|●|●|●| | | | | |●|● 426 +|Parameter 2|●|●|●|●|●| | | | | |●|● 427 +|Parameter 3|●|●|●|●|●| | | | | |●|● 424 424 425 425 **Features** 426 426 427 427 Add the time data specified in (s1) and the time data specified in (s2), and store the result of the addition in the device number specified in (d) or later. 428 428 429 -(% style="text-align:center" %) 430 -[[image:07-5 Basic instructions_html_37222a6e282347f9.png||height="79" width="750"]] 433 +[[image:07-5 Basic instructions_html_37222a6e282347f9.png]] 431 431 432 432 **Example** 433 433 434 434 When 6:32:40 and 7:48:10 are added together 435 435 436 -(% style="text-align:center" %) 437 -[[image:07-5 Basic instructions_html_90138670198ab422.png||height="94" width="750"]] 439 +[[image:07-5 Basic instructions_html_90138670198ab422.png]] 438 438 439 439 When the calculation result time exceeds 24 o'clock, the carry flag turns ON, and the value after 24 hours is subtracted becomes the calculation result. For example, when 14:20:30 and 20:20:20 are added, the result is not 34:40:50, but 10:40:50. 440 440 441 -(% style="text-align:center" %) 442 -[[image:07-5 Basic instructions_html_bac419ce2dc0dc2.png||height="91" width="750"]] 443 +[[image:07-5 Basic instructions_html_bac419ce2dc0dc2.png]] 443 443 444 444 When the calculation result is 0 (0 hour, 0 minute, 0 second), the zero flag turns on. 445 445 ... ... @@ -451,7 +451,7 @@ 451 451 |SM151|Carry|It is ON when the result of the TADD(P) instruction exceeds the maximum clock data value of 23:59:59 452 452 |SM153|Zero|It is ON when the result of the TADD(P) instruction is 0:00:00 453 453 454 -✎**Note :**455 +✎**Note** 455 455 456 456 The devices specified in (s1), (s2), (d) occupy 3 points respectively. Be careful not to overlap with the device used for machine control. 457 457 ... ... @@ -460,7 +460,7 @@ 460 460 **Error code** 461 461 462 462 |**Error code**|**Content** 463 -|4085H|When reading the specified device range exceeds the corresponding device range 464 +|4085H|{{id name="OLE_LINK344"/}}When reading the specified device range exceeds the corresponding device range 464 464 |4086H|When writing the specified device range exceeds the corresponding device range 465 465 |4084H|((( 466 466 When the values specified in (s1) and (s2) are other than 0 to 23 ... ... @@ -470,26 +470,24 @@ 470 470 471 471 **Example** 472 472 473 -(% style="text-align:center" %) 474 -[[image:07-5 Basic instructions_html_4f75eedee7172bbb.png||height="35" width="349"]] 474 +[[image:07-5 Basic instructions_html_4f75eedee7172bbb.png]] 475 475 476 476 Set D0 time to 16:30:00 and D10 time to 4:30:0 477 477 478 -(% style="text-align:center" %) 479 479 [[image:07-5 Basic instructions_html_c64e0faf2af172f8.png]] 480 480 481 -(% style="text-align:center" %) 482 482 [[image:07-5 Basic instructions_html_66e3a2eadeb2ecbb.png]] 483 483 484 484 After the coil is turned on, the D20 time is 21:0:0 485 485 486 -(% style="text-align:center" %) 487 487 [[image:07-5 Basic instructions_html_a9b235835aa41200.png]] 488 488 489 -== **TSUB/The subtraction of clock data** == 490 490 491 -**TSUB(P)** 492 492 488 +{{id name="_Toc6604"/}}{{id name="_Toc16422"/}}**TSUB/The subtraction of clock data** 489 + 490 +[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] **TSUB(P)** 491 + 493 493 Subtract the time data stored after the device number specified in (s1) and the time data stored after the device number specified in (s2), and store the subtraction result in the device number specified in (d) or later . 494 494 495 495 -[TSUB (s1) (s2) (d)] ... ... @@ -515,21 +515,24 @@ 515 515 516 516 **Device used** 517 517 518 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="5" %)**Devices**|((( 519 -**Offset modification** 517 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|((( 518 +**Offset** 519 + 520 +**modification** 520 520 )))|((( 521 -**Pulse extension** 522 +**Pulse** 523 + 524 +**extension** 522 522 ))) 523 -|**T**|**C**|**D**|**R**|**SD**|**[D]**|**XXP** 524 -|(% rowspan="3" %)TSUB|Parameter 1|●|●|●|●|●|●|● 525 -|Parameter 2|●|●|●|●|●|●|● 526 -|Parameter 3|●|●|●|●|●|●|● 526 +|**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 527 +|(% rowspan="3" %)TSUB|Parameter 1| | | | | | | | | | | | | | |●|●|●|●|●| | | | | |●|● 528 +|Parameter 2| | | | | | | | | | | | | | |●|●|●|●|●| | | | | |●|● 529 +|Parameter 3| | | | | | | | | | | | | | |●|●|●|●|●| | | | | |●|● 527 527 528 528 **Features** 529 529 530 530 Subtract the time data specified in (s1) and the time data specified in (s2), and store the subtraction result in the device number specified in (d) or later. 531 531 532 -(% style="text-align:center" %) 533 533 [[image:07-5 Basic instructions_html_5a93455e4cd8a27.png]] 534 534 535 535 **Example** ... ... @@ -536,12 +536,10 @@ 536 536 537 537 When subtracting 10:40:20 and 3:50:10 538 538 539 -(% style="text-align:center" %) 540 540 [[image:07-5 Basic instructions_html_2473f03fc493780c.png]] 541 541 542 542 When the calculation result time is a negative number, the borrow flag turns on and the data +24 is the calculation result. For example, in the case of subtracting 4:50:32 and 10:42:12, the result is not -6:8:20, but 18:8:20. 543 543 544 -(% style="text-align:center" %) 545 545 [[image:07-5 Basic instructions_html_24b998b4c3c4ec73.png]] 546 546 547 547 When the calculation result is 0 (0 hour, 0 minute, 0 second), the zero flag turns on. ... ... @@ -552,7 +552,7 @@ 552 552 |SM152|Borrow|It is ON when the result of the TSUB(P) instruction is less than 0:00:00 553 553 |SM153|Zero|It is ON when the result of the TSUB(P) instruction is at the time of 0:00:00:00 554 554 555 -✎**Note :**555 +✎**Note** 556 556 557 557 • The devices specified in (s1), (s2), and (d) occupy 3 points respectively. Be careful not to overlap with the device used for machine control. 558 558 ... ... @@ -571,23 +571,19 @@ 571 571 572 572 **Example** 573 573 574 -(% style="text-align:center" %) 575 -[[image:07-5 Basic instructions_html_e3a5d4793d3ccd2d.png||height="36" width="372"]] 574 +[[image:07-5 Basic instructions_html_e3a5d4793d3ccd2d.png]] 576 576 577 577 Set D0 time to 16:30:00 and D10 time to 4:30:0 578 578 579 -(% style="text-align:center" %) 580 580 [[image:07-5 Basic instructions_html_c64e0faf2af172f8.png]] 581 581 582 -(% style="text-align:center" %) 583 583 [[image:07-5 Basic instructions_html_66e3a2eadeb2ecbb.png]] 584 584 585 585 After the coil is turned on, the D20 time is 12:00:00 586 586 587 -(% style="text-align:center" %) 588 588 [[image:07-5 Basic instructions_html_8f93ea19ba10652b.png]] 589 589 590 -**TRD/Clock data reading** 586 +{{id name="_Toc10358"/}}{{id name="_Toc12073"/}}[[image:07-5 Basic instructions_html_501fb256fd034ca6.gif]] **TRD/Clock data reading** 591 591 592 592 **TRD(P)** 593 593 ... ... @@ -606,13 +606,17 @@ 606 606 607 607 **Device used** 608 608 609 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="4" %)**Devices**|((( 610 -**Offset modification** 605 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|((( 606 +**Offset** 607 + 608 +**modification** 611 611 )))|((( 612 -**Pulse extension** 610 +**Pulse** 611 + 612 +**extension** 613 613 ))) 614 -|**T**|**C**|**D**|**R**|**[D]**|**XXP** 615 -|TRD|Parameter 1|●|●|●|●|●|● 614 +|**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 615 +|TRD|Parameter 1| | | | | | | | | | | | | | |●|●|●|●| | | | | | |●|● 616 616 617 617 **Features** 618 618 ... ... @@ -638,7 +638,7 @@ 638 638 |SD105|The year data of the clock data is stored in a 4-digit BIN code of the Gregorian calendar. 639 639 |SD106|The week data of the clock data is stored in BIN code. (0: day, 1: one, ..., 6: six) are stored in BIN code. 640 640 641 -✎**Note :**641 +✎**Note** 642 642 643 643 • The device specified in (d) occupies 7 points. Be careful not to overlap with the device used for machine control. 644 644 ... ... @@ -649,15 +649,13 @@ 649 649 650 650 **Example** 651 651 652 -(% style="text-align:center" %) 653 -[[image:07-5 Basic instructions_html_b81c1991fec5b4b1.png||height="68" width="250"]] 652 +[[image:07-5 Basic instructions_html_b81c1991fec5b4b1.png]] 654 654 655 655 After the M0 coil is turned on, the current date and time are read as 2020-2-19 13:10:38 Wednesday 656 656 657 -(% style="text-align:center" %) 658 -[[image:07-5 Basic instructions_html_fe82ecd18ebfd787.png||height="48" width="602"]] 656 +[[image:07-5 Basic instructions_html_fe82ecd18ebfd787.png]] 659 659 660 -= =**TWR/Clock data writing**==658 +{{id name="_Toc24237"/}}{{id name="_Toc487"/}}**TWR/Clock data writing** 661 661 662 662 [[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] **TWR(P)** 663 663