Changes for page 12 Clock operation
Last modified by Mora Zhou on 2023/11/21 17:27
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1357,7 +1357,7 @@ 1357 1357 1358 1358 • When D0<1,000, the value of (D0)-1,000 is stored in D1. 1359 1359 1360 - {{id name="_Toc1180"/}}{{id name="_Toc21657"/}}{{idname="_Toc27323"/}}[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]]**DBAND/BIN 32-bit data dead zone control**1360 +== **DBAND/BIN 32-bit data dead zone control** == 1361 1361 1362 1362 **DBAND(P)** 1363 1363 ... ... @@ -1375,16 +1375,14 @@ 1375 1375 1376 1376 **Device used** 1377 1377 1378 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 1379 -**Pulse** 1380 - 1381 -**extension** 1378 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="13" %)**Devices**|**Offset modification**|((( 1379 +**Pulse extension** 1382 1382 ))) 1383 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**1384 -|(% rowspan="4" %)DBAND|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●||●|●1385 -|Parameter 2| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●||●|●1386 -|Parameter 3| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●| | ||●|●1387 -|Parameter 4| | | | | | | | | | | |●|●|●|●|●|●|●|●|●|●| | ||●|●1381 +|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**[D]**|**XXP** 1382 +|(% rowspan="4" %)DBAND|Parameter 1|●|●|●|●|●|●|●|●|●|●|●|●|●|●|● 1383 +|Parameter 2|●|●|●|●|●|●|●|●|●|●|●|●|●|●|● 1384 +|Parameter 3|●|●|●|●|●|●|●|●|●|●|●| | |●|● 1385 +|Parameter 4| |●|●|●|●|●|●|●|●|●|●| | |●|● 1388 1388 1389 1389 **Features** 1390 1390 ... ... @@ -1391,20 +1391,17 @@ 1391 1391 The input value (BIN 32-bit value) specified in (s3) controls the output value stored in the device specified in (d) according to the upper and lower limits of the dead zone specified in (s1) and (s2). The output value is controlled as follows. 1392 1392 1393 1393 |**Condition**|**The value stored in the output value** 1394 -|When dead zone low limit ((s1), (s1)+1)> input value ((s3), (s3)+1)| {{id name="OLE_LINK42"/}}Input value ((s3), (s3)+1)-dead zone low limit ((s1), (s1)+1)1395 -|When dead zone high limit ((s1), (s1)+1) <input value ((s3), (s3)+1)| {{id name="OLE_LINK357"/}}Input value ((s3), (s3)+1)-dead zone high limit ((s2), (s2)+1)1392 +|When dead zone low limit ((s1), (s1)+1)> input value ((s3), (s3)+1)|Input value ((s3), (s3)+1)-dead zone low limit ((s1), (s1)+1) 1393 +|When dead zone high limit ((s1), (s1)+1) <input value ((s3), (s3)+1)|Input value ((s3), (s3)+1)-dead zone high limit ((s2), (s2)+1) 1396 1396 |When dead zone low limit ((s1), (s1)+1) ≤ input value ((s3), (s3)+1) ≤ dead zone high limit ((s2), (s2)+1)|0 1397 1397 1398 - 1399 1399 ((( 1400 -• When the output value stored in (d) is a signed BIN 32-bit value, and the operation result exceeds the range of -2,147,483,648 to 2,147,483,647, the situation is as the following example. For example,** **When (s1) and (s1)+1 are 1000, (s3) and (s3)+1 are -2,147,483,648, then the output value=1397 +• When the output value stored in (d) is a signed BIN 32-bit value, and the operation result exceeds the range of -2,147,483,648 to 2,147,483,647, the situation is as the following example. For example,** **When (s1) and (s1)+1 are 1000, (s3) and (s3)+1 are -2,147,483,648, then the output value= 1401 1401 1402 1402 -2,147,483,648-1000=80000000H-000003E8H=7FFFFC18H=2,147,482,648. 1403 1403 1404 -[[image:07-5 Basic instructions_html_e0144674dad3e8fd.png]] 1405 - 1406 - 1407 - 1401 +(% style="text-align:center" %) 1402 +[[image:07-5 Basic instructions_html_e0144674dad3e8fd.png||height="243" width="550"]] 1408 1408 ))) 1409 1409 1410 1410 **Error code** ... ... @@ -1416,7 +1416,8 @@ 1416 1416 1417 1417 **Example** 1418 1418 1419 -[[image:07-5 Basic instructions_html_88f3fe0fb4841bab.png]] 1414 +(% style="text-align:center" %) 1415 +[[image:07-5 Basic instructions_html_88f3fe0fb4841bab.png||height="42" width="453"]] 1420 1420 1421 1421 • When (D1, D0)<(-10,000), the value of (D1, D0)-(-10,000) is stored in (D11, D10). 1422 1422 ... ... @@ -1424,9 +1424,9 @@ 1424 1424 1425 1425 • When 10,000< (D1, D0), the value of (D1, D0)-10,000 is stored in D1. 1426 1426 1427 - {{id name="_Toc21668"/}}{{id name="_Toc25056"/}}{{idname="_Toc17582"/}}{{id name="OLE_LINK165"/}}**BINDA/BIN 16-bit data → Decimal ASCII conversion**1423 +== **BINDA/BIN 16-bit data → Decimal ASCII conversion** == 1428 1428 1429 - [[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]]**BINDA(P)**1425 +**BINDA(P)** 1430 1430 1431 1431 Convert the BIN 16-bit data specified in (s) and the value of each digit in decimal numbers into ASCII codes and store them after the device number specified in (d). 1432 1432 ... ... @@ -1440,30 +1440,28 @@ 1440 1440 1441 1441 **Device used** 1442 1442 1443 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 1444 -**Pulse** 1445 - 1446 -**extension** 1439 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="11" %)**Devices**|**Offset modification**|((( 1440 +**Pulse extension** 1447 1447 ))) 1448 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**1449 -|(% rowspan="2" %)BINDA|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|| |●|●||●|●1450 -|Parameter 2| | | | | | | | | | | | | | | | |●|●|●| | || | |●|●1442 +|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**K**|**H**|**[D]**|**XXP** 1443 +|(% rowspan="2" %)BINDA|Parameter 1|●|●|●|●|●|●|●|●|●|●|●|●|● 1444 +|Parameter 2| | | | | | |●|●|●| | |●|● 1451 1451 1452 1452 **Features** 1453 1453 1454 1454 Convert the BIN 16-bit data specified in (s) and the value of each digit in decimal numbers into ASCII codes and store them after the device number specified in (d). 1455 1455 1456 - 1457 - 1458 1458 ((( 1459 -←Only store 0 when SM191 is OFF 1460 - 1451 +(% style="text-align:center" %) 1461 1461 [[image:07-5 Basic instructions_html_57bda5f08026449d.png]] 1453 + 1454 +←Only store 0 when SM191 is OFF 1462 1462 ))) 1463 1463 1464 1464 For example, when -12,345 is specified in (s) (in the case of specifying signed) 1465 1465 1466 -[[image:07-5 Basic instructions_html_f346102467b9bef9.png]] 1459 +(% style="text-align:center" %) 1460 +[[image:07-5 Basic instructions_html_f346102467b9bef9.png||height="169" width="850"]] 1467 1467 1468 1468 The calculation result stored in (d) will be as below. 1469 1469 ... ... @@ -1483,19 +1483,20 @@ 1483 1483 1484 1484 **Example** 1485 1485 1480 +(% style="text-align:center" %) 1481 +[[image:07-5 Basic instructions_html_c598806a42484ed.png||height="76" width="300"]] 1486 1486 1487 - 1488 1488 ((( 1489 1489 When X000 is ON, convert the value of 16-bit data (BIN) D1000 into decimal ASCII code, and then use PR instruction to output the 1490 1490 1491 1491 converted ASCII code character by character to the program of Y040 to Y057. 1492 1492 1493 - [[image:07-5Basic instructions_html_c598806a42484ed.png]]1488 + 1494 1494 ))) 1495 1495 1496 - {{id name="_Toc12255"/}}{{id name="_Toc8216"/}}{{idname="_Toc470"/}}**DBINDA/BIN 32-bit data → Decimal ASCII conversion**1491 +== **DBINDA/BIN 32-bit data → Decimal ASCII conversion** == 1497 1497 1498 - [[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]]**DBINDA(P)**1493 +**DBINDA(P)** 1499 1499 1500 1500 Convert the BIN 32-bit data specified in (s) and the value of each bit in decimal numbers into ASCII codes and store them after the device number specified in (d). 1501 1501 ... ... @@ -1505,22 +1505,18 @@ 1505 1505 1506 1506 |**Parameter**|**Content**|**Range**|**Data type**|**Data type (label)** 1507 1507 |(s)|BIN data for ASCII conversion|-2,147483648 to 2147483647|Signed BIN 32 bit|ANY32_S 1508 -|(d)| {{id name="OLE_LINK2"/}}The start number of the device storing the conversion result|-|String|ANYSTRING_SINGLE1503 +|(d)|The start number of the device storing the conversion result|-|String|ANYSTRING_SINGLE 1509 1509 1510 1510 **Device used** 1511 1511 1512 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|((( 1513 -**Offset** 1514 - 1515 -**modification** 1507 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="13" %)**Devices**|((( 1508 +**Offset modification** 1516 1516 )))|((( 1517 -**Pulse** 1518 - 1519 -**extension** 1510 +**Pulse extension** 1520 1520 ))) 1521 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**1522 -|(% rowspan="2" %)DBINDA|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●||●|●1523 -|Parameter 2| | | | | | | | | | | | | | | | |●|●|●| | | | ||●|●1512 +|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**[D]**|**XXP** 1513 +|(% rowspan="2" %)DBINDA|Parameter 1|●|●|●|●|●|●|●|●|●|●|●|●|●|●|● 1514 +|Parameter 2| | | | | | |●|●|●| | | | |●|● 1524 1524 1525 1525 **Features** 1526 1526 ... ... @@ -1528,8 +1528,11 @@ 1528 1528 1529 1529 For example, when -12345678 is specified in (s). (in the case of specifying signed) 1530 1530 1531 -[[image:07-5 Basic instructions_html_4d939462838cf09b.gif]] The calculation result stored in (d) will be as below. 1522 +(% style="text-align:center" %) 1523 +[[image:07-5 Basic instructions_html_4d939462838cf09b.gif]] 1532 1532 1525 + The calculation result stored in (d) will be as below. 1526 + 1533 1533 • In "Sign", 20H is stored when the BIN data is positive, and 2DH is stored when it is negative. 1534 1534 1535 1535 • 20H is stored at 0 to the left of the effective number of digits. (Suppress 0.) For example, in the case of "0012034560", "00" becomes 20H, and "12034560" becomes effective digits. ... ... @@ -1546,13 +1546,14 @@ 1546 1546 1547 1547 **Example** 1548 1548 1549 -[[image:07-5 Basic instructions_html_ec8ac32d748a991c.png]] 1543 +(% style="text-align:center" %) 1544 +[[image:07-5 Basic instructions_html_ec8ac32d748a991c.png||height="59" width="300"]] 1550 1550 1551 1551 When X000 is ON, convert the value of 32-bit data (BIN) D1000 into decimal ASCII code, and then use PR (FNC 77) instruction to output the converted ASCII code character by character to the program in Y040 to Y051 in time and time division. 1552 1552 1553 - {{id name="_Toc19693"/}}{{id name="_Toc18078"/}}{{idname="_Toc5726"/}}**DABIN/Decimal ASCII → BIN conversion**1548 +== **DABIN/Decimal ASCII → BIN conversion** == 1554 1554 1555 - [[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]]**DABIN(P)**1550 +**DABIN(P)** 1556 1556 1557 1557 Digital ASCII code (30H to 39H) is a instruction to convert real data into BIN data. 1558 1558 ... ... @@ -1566,24 +1566,23 @@ 1566 1566 1567 1567 **Device used** 1568 1568 1569 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 1570 -**Pulse** 1571 - 1572 -**extension** 1564 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="8" %)**Devices**|**Offset modification**|((( 1565 +**Pulse extension** 1573 1573 ))) 1574 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**1575 -|(% rowspan="2" %)DABIN|Parameter 1| | | | | | | | | | | | | | | | |●|●|●|| | | | |●|●1576 -|Parameter 2| | | | | | | | | | | |●|●|●|●|●|●|●|●|| | | | |●|●1567 +|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**[D]**|**XXP** 1568 +|(% rowspan="2" %)DABIN|Parameter 1| | | | | |●|●|●|●|● 1569 +|Parameter 2|●|●|●|●|●|●|●|●|●|● 1577 1577 1578 1578 **Features** 1579 1579 1580 1580 The decimal ASCII data stored after the device number specified in (s) is converted into BIN 16-bit data and stored in the device specified in (d). 1581 1581 1582 -[[image:07-5 Basic instructions_html_22c5cb32a0a32214.png]] 1575 +(% style="text-align:center" %) 1576 +[[image:07-5 Basic instructions_html_22c5cb32a0a32214.png||height="273" width="750"]] 1583 1583 1584 1584 |**ASCII S**|**ASCII 10^^0^^**|**ASCII 10^^1^^**|**ASCII 10^^2^^**|**ASCII 10^^3^^**|**ASCII 10^^4^^** 1585 1585 |**ASCII code**|((( 1586 - {{id name="OLE_LINK36"/}}Units of1580 +Units of 1587 1587 1588 1588 ASCII code 1589 1589 )))|((( ... ... @@ -1606,7 +1606,8 @@ 1606 1606 1607 1607 For example, When -25,108 is specified in (s) 1608 1608 1609 -[[image:07-5 Basic instructions_html_10fb2792e37dbf23.png]] 1603 +(% style="text-align:center" %) 1604 +[[image:07-5 Basic instructions_html_10fb2792e37dbf23.png||height="123" width="750"]] 1610 1610 1611 1611 • The ASCII data specified in (s) to (s)+2 is within the range of -32,768 to +32,767. 1612 1612 ... ... @@ -1636,11 +1636,12 @@ 1636 1636 **Example** 1637 1637 ))) 1638 1638 1639 -[[image:07-5 Basic instructions_html_bec2bea131b58c03.png]] 1634 +(% style="text-align:center" %) 1635 +[[image:07-5 Basic instructions_html_bec2bea131b58c03.png||height="55" width="300"]] 1640 1640 1641 - {{id name="_Toc3351"/}}{{id name="_Toc26383"/}}{{idname="_Toc26233"/}}**DDABIN/Decimal ASCII → BIN32-bit data conversion**1637 +== **DDABIN/Decimal ASCII → BIN32-bit data conversion** == 1642 1642 1643 - [[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]]**DDABIN(P)**1639 +**DDABIN(P)** 1644 1644 1645 1645 The decimal ASCII data stored after the device number specified in (s) is converted into BIN 32-bit data and stored in the device number specified in (d). 1646 1646 ... ... @@ -1654,31 +1654,31 @@ 1654 1654 1655 1655 **Device used** 1656 1656 1657 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 1658 -**Pulse** 1659 - 1660 -**extension** 1653 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="10" %)**Devices**|**Offset modification**|((( 1654 +**Pulse extension** 1661 1661 ))) 1662 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**1663 -|(% rowspan="2" %)DDABIN|Parameter 1| | | | | | | | | | | | | | | | |●|●|●| | || | |●|●1664 -|Parameter 2| | | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|| | |●|●1656 +|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**[D]**|**XXP** 1657 +|(% rowspan="2" %)DDABIN|Parameter 1| | | | | |●|●|●| | |●|● 1658 +|Parameter 2|●|●|●|●|●|●|●|●|●|●|●|● 1665 1665 1666 1666 **Features** 1667 1667 1668 1668 The decimal ASCII data stored after the device number specified in (s) is converted into BIN 32-bit data and stored in the device specified in (d). 1669 1669 1670 -[[image:07-5 Basic instructions_html_c444110b273f33b7.gif]] 1664 +(% style="text-align:center" %) 1665 +[[image:07-5 Basic instructions_html_c444110b273f33b7.gif||height="193" width="800"]] 1671 1671 1672 1672 |**ASCII S**|**ASCII code**|**ASCII S**|**ASCII code** 1673 -|ASCII 10^^0^^|Units of ASCII code|ASCII 10^^5^^| {{id name="OLE_LINK38"/}}Hundred thousands of ASCII code1668 +|ASCII 10^^0^^|Units of ASCII code|ASCII 10^^5^^|Hundred thousands of ASCII code 1674 1674 |ASCII 10^^1^^|Tens of ASCII code|ASCII 10^^6^^|Millions of ASCII code 1675 1675 |ASCII 10^^2^^|Hundreds of ASCII code|ASCII 10^^7^^|Ten millions of ASCII code 1676 -|ASCII 10^^3^^| {{id name="OLE_LINK37"/}}Thousands of ASCII code|ASCII 10^^8^^|Hundred millions of ASCII code1671 +|ASCII 10^^3^^|Thousands of ASCII code|ASCII 10^^8^^|Hundred millions of ASCII code 1677 1677 |ASCII 10^^4^^|Tens thousands of ASCII code|ASCII 10^^9^^|billions of ASCII code 1678 1678 1679 1679 When -1234543210 is specified in (s) (When signed is specified) 1680 1680 1681 -[[image:07-5 Basic instructions_html_1b4c7e1c663a4399.png]] 1676 +(% style="text-align:center" %) 1677 +[[image:07-5 Basic instructions_html_1b4c7e1c663a4399.png||height="230" width="800"]] 1682 1682 1683 1683 • The ASCII data specified in (s) to (s)+5 is within the range of -2,147,483,648 to +2,147,483,647. In addition, the data stored in the high byte of (s)+5 will be ignored. 1684 1684 ... ... @@ -1694,7 +1694,7 @@ 1694 1694 |4084H|((( 1695 1695 When the Sign data exceeds the range of 30H to 39H, 20H, 00H and 2DH; 1696 1696 1697 - {{id name="OLE_LINK39"/}}When the ASCII code of each bit specified in (s) to (s)+5 exceeds the range of 30H to 39H, 20H and 00H;1693 +When the ASCII code of each bit specified in (s) to (s)+5 exceeds the range of 30H to 39H, 20H and 00H; 1698 1698 1699 1699 When the ASCII data specified in (s) to (s)+5 exceeds the range of -2,147,483,648 to +2,147,483,647 1700 1700 ))) ... ... @@ -1703,13 +1703,14 @@ 1703 1703 1704 1704 **Example** 1705 1705 1706 -[[image:07-5 Basic instructions_html_feea438c943ea9dd.png]] 1702 +(% style="text-align:center" %) 1703 +[[image:07-5 Basic instructions_html_feea438c943ea9dd.png||height="34" width="300"]] 1707 1707 1708 1708 When X000 is ON, the Signs set in to D20 to D25 and the ASCII code data of 10-digit decimal numbers are converted into BIN values and then saved to the program in D0 to D1. 1709 1709 1710 - {{id name="_Toc26556"/}}{{id name="_Toc12799"/}}{{idname="_Toc23863"/}}**LIMIT/ BIN 16-bit data high and low limit control**1707 +== **LIMIT/ BIN 16-bit data high and low limit control** == 1711 1711 1712 - [[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]]**LIMIT(P)**1709 +**LIMIT(P)** 1713 1713 1714 1714 The input value (BIN 16-bit value) specified in (s3) controls the output value stored in the device specified in (d) according to the upper and lower limit value ranges specified in (s1) and (s2). 1715 1715 ... ... @@ -1725,16 +1725,14 @@ 1725 1725 1726 1726 **Device used** 1727 1727 1728 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 1729 -**Pulse** 1730 - 1731 -**extension** 1725 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="11" %)**Devices**|**Offset modification**|((( 1726 +**Pulse extension** 1732 1732 ))) 1733 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**1734 -|(% rowspan="4" %)LIMIT|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|| |●|●||●|●1735 -|Parameter 2| | | | | | | | | | |●|●|●|●|●|●|●|●|●|| |●|●||●|●1736 -|Parameter 3| | | | | | | | | | |●|●|●|●|●|●|●|●|●| | || | |●|●1737 -|Parameter 4| | | | | | | | | | | |●|●|●|●|●|●|●|●| | || | |●|●1728 +|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**K**|**H**|**[D]**|**XXP** 1729 +|(% rowspan="4" %)LIMIT|Parameter 1|●|●|●|●|●|●|●|●|●|●|●|●|● 1730 +|Parameter 2|●|●|●|●|●|●|●|●|●|●|●|●|● 1731 +|Parameter 3|●|●|●|●|●|●|●|●|●| | |●|● 1732 +|Parameter 4| |●|●|●|●|●|●|●|●| | |●|● 1738 1738 1739 1739 **Features** 1740 1740 ... ... @@ -1745,13 +1745,13 @@ 1745 1745 |High limit value (s1) <input value (s3)|High limit value (s2) 1746 1746 |Low limit value (s1) ≤ input value (s3) ≤ high limit value (s2)|Input value (s3) 1747 1747 1748 - 1749 1749 ((( 1750 -•Only in the case of controlling high limit value, set the minimum value of data range in the low limit value specified in (s1). 1744 +• Only in the case of controlling high limit value, set the minimum value of data range in the low limit value specified in (s1). 1751 1751 1752 1752 • Only in the case of controlling low limit value, set the maximum value of data range in the high limit value specified in (s2). 1753 1753 1754 -[[image:07-5 Basic instructions_html_50eb5229b027aa14.png]] 1748 +(% style="text-align:center" %) 1749 +[[image:07-5 Basic instructions_html_50eb5229b027aa14.png||height="297" width="550"]] 1755 1755 ))) 1756 1756 1757 1757 **Error code** ... ... @@ -1763,6 +1763,7 @@ 1763 1763 1764 1764 **Example** 1765 1765 1761 +(% style="text-align:center" %) 1766 1766 [[image:07-5 Basic instructions_html_d67a2e740d4fc738.png]] 1767 1767 1768 1768 When X000 is ON ... ... @@ -1773,9 +1773,9 @@ 1773 1773 1774 1774 • When 5,000 <D0, D1 is 5,000. 1775 1775 1776 - {{id name="_Toc32553"/}}{{id name="_Toc9981"/}}{{idname="_Toc9158"/}}**DLIMIT/BIN 32-bit data high and low limit control**1772 +== **DLIMIT/BIN 32-bit data high and low limit control** == 1777 1777 1778 - [[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]]**DLIMIT(P)**1774 +**DLIMIT(P)** 1779 1779 1780 1780 The input value (BIN 32-bit value) specified in (s3) controls the output value stored in the device specified in (d) according to the range of high and low limit values specified in (s1) and (s2). 1781 1781 ... ... @@ -1791,16 +1791,14 @@ 1791 1791 1792 1792 **Device used** 1793 1793 1794 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 1795 -**Pulse** 1796 - 1797 -**extension** 1790 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="13" %)**Devices**|**Offset modification**|((( 1791 +**Pulse extension** 1798 1798 ))) 1799 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**1800 -|(% rowspan="4" %)DLIMIT|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●||●|●1801 -|Parameter 2| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●||●|●1802 -|Parameter 3| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●| | ||●|●1803 -|Parameter 4| | | | | | | | | | | |●|●|●|●|●|●|●|●|●|●| | ||●|●1793 +|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**[D]**|**XXP** 1794 +|(% rowspan="4" %)DLIMIT|Parameter 1|●|●|●|●|●|●|●|●|●|●|●|●|●|●|● 1795 +|Parameter 2|●|●|●|●|●|●|●|●|●|●|●|●|●|●|● 1796 +|Parameter 3|●|●|●|●|●|●|●|●|●|●|●| | |●|● 1797 +|Parameter 4| |●|●|●|●|●|●|●|●|●|●| | |●|● 1804 1804 1805 1805 **Features** 1806 1806 ... ... @@ -1811,7 +1811,7 @@ 1811 1811 |High limit value ((s2), (s2)+1) <input value ((s3), (s3)+1)|High limit value ((s2), (s2)+1) 1812 1812 |Low limit value ((s1), (s1)+1) ≤ input value ((s3), (s3)+1) ≤ high limit value ((s2), (s2)+1)|Input value ((s3), (s3)+1) 1813 1813 1814 - {{idname="OLE_LINK43"/}}{{idname="OLE_LINK40"/}}•Only in the case of controlling high limit value, set the minimum value of data range in the low limit value specified in (s1).1808 +• Only in the case of controlling high limit value, set the minimum value of data range in the low limit value specified in (s1). 1815 1815 1816 1816 • Only in the case of controlling low limit value, set the maximum value of data range in the high limit value specified in (s2). 1817 1817 ... ... @@ -1824,7 +1824,8 @@ 1824 1824 1825 1825 **Example** 1826 1826 1827 -[[image:07-5 Basic instructions_html_217355b90f4b4e16.png]] 1821 +(% style="text-align:center" %) 1822 +[[image:07-5 Basic instructions_html_217355b90f4b4e16.png||height="53" width="400"]] 1828 1828 1829 1829 Operation: 1830 1830 ... ... @@ -1834,9 +1834,9 @@ 1834 1834 1835 1835 • When 1,000,000 <(D1, D0), (D11, D10) is 1,000,000. 1836 1836 1837 - {{id name="_Toc12534"/}}{{id name="_Toc28213"/}}{{idname="_Toc24591"/}}**SCL/BIN 16-bit unit scale (coordinate data of each point)**1832 +== **SCL/BIN 16-bit unit scale (coordinate data of each point)** == 1838 1838 1839 - [[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]]**SCL(P)**1834 +**SCL(P)** 1840 1840 1841 1841 The scaling conversion data (16-bit data unit) specified in (s2) is scaled from the input value specified in (s1), and the calculation result is stored in the device specified in (d). 1842 1842 ... ... @@ -1851,15 +1851,13 @@ 1851 1851 1852 1852 **Device used** 1853 1853 1854 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 1855 -**Pulse** 1856 - 1857 -**extension** 1849 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="11" %)**Devices**|**Offset modification**|((( 1850 +**Pulse extension** 1858 1858 ))) 1859 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**1860 -|(% rowspan="3" %)SCL|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|| |●|●||●|●1861 -|Parameter 2| | | | | | | | | | | | | | | | |●|●|●| | || | |●|●1862 -|Parameter 3| | | | | | | | | | | |●|●|●|●|●|●|●|●| | || | |●|●1852 +|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**K**|**H**|**[D]**|**XXP** 1853 +|(% rowspan="3" %)SCL|Parameter 1|●|●|●|●|●|●|●|●|●|●|●|●|● 1854 +|Parameter 2| | | | | | |●|●|●| | |●|● 1855 +|Parameter 3| |●|●|●|●|●|●|●|●| | |●|● 1863 1863 1864 1864 **Features** 1865 1865 ... ... @@ -1875,7 +1875,8 @@ 1875 1875 |(% rowspan="2" %)Point n|X coordinate|(s2)+2n-1 1876 1876 |Y coordinate|(s2)+2n 1877 1877 1878 -[[image:07-5 Basic instructions_html_80185ccddb878234.png]] 1871 +(% style="text-align:center" %) 1872 +[[image:07-5 Basic instructions_html_80185ccddb878234.png||height="422" width="750"]] 1879 1879 1880 1880 • If the operation result is not an integer value, round the first digit below the decimal point. 1881 1881 ... ... @@ -1891,10 +1891,13 @@ 1891 1891 1892 1892 In the case of scaling conversion characteristics as shown in the figure below, set it as the following data sheet. 1893 1893 1894 -[[image:07-5 Basic instructions_html_74fd22d845ad450e.png]] 1888 +(% style="text-align:center" %) 1889 +[[image:07-5 Basic instructions_html_74fd22d845ad450e.png||height="210" width="750"]] 1895 1895 1896 -|(% colspan="2" rowspan="2" %)**Set items**|(% colspan="3" %)**Sett device and content**|(% rowspan="2" %)**Remarks** 1897 -|(% colspan="2" %)**When R0 is specified in (s2)**|**Set content** 1891 +|(% colspan="2" rowspan="2" %)((( 1892 +**Set items** 1893 +)))|(% colspan="3" %)**Sett device and content**|(% rowspan="2" %)**Remarks** 1894 +|(% colspan="2" %)**When R0 is specified in (s2)**|**Set content** 1898 1898 |(% colspan="2" %)Coordinate points|(s2)|R0|K10| 1899 1899 |(% rowspan="2" %)Point 1|X coordinate|(s2)+1|R1|K5| 1900 1900 |Y coordinate|(s2)+2|R2|K20| ... ... @@ -1942,6 +1942,7 @@ 1942 1942 1943 1943 **Example** 1944 1944 1942 +(% style="text-align:center" %) 1945 1945 [[image:07-5 Basic instructions_html_5519d7b41f15b6d6.png]] 1946 1946 1947 1947 [[image:07-5 Basic instructions_html_ace075fb7675de8e.gif]] When -100 ≤ D0(X) < 0, D100(Y)= ... ... @@ -1950,14 +1950,13 @@ 1950 1950 1951 1951 when 0< D0(X) ≤ 100, D100(Y)= 1952 1952 1953 -[[image:07-5 Basic instructions_html_e35e13160c08a133.png]] 1951 +(% style="text-align:center" %) 1952 +[[image:07-5 Basic instructions_html_e35e13160c08a133.png||height="362" width="550"]] 1954 1954 1954 +== **DSCL/32-bit unit scale (coordinate data of each point)** == 1955 1955 1956 +**DSCL(P)** 1956 1956 1957 -{{id name="_Toc4862"/}}{{id name="_Toc11340"/}}{{id name="_Toc25383"/}}**DSCL/32-bit unit scale (coordinate data of each point)** 1958 - 1959 -[[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]] **DSCL(P)** 1960 - 1961 1961 The conversion data (32-bit data unit) for scaling specified in (s2) is scaled by the input value specified in (s1), and the operation result is stored in the device specified in (d). 1962 1962 1963 1963 -[DSCL (s1) (s2) (d)] ... ... @@ -1971,19 +1971,17 @@ 1971 1971 1972 1972 **Device used** 1973 1973 1974 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Device**|**Offset modification**|((( 1975 -**Pulse** 1976 - 1977 -**extension** 1971 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="13" %)**Device**|**Offset modification**|((( 1972 +**Pulse extension** 1978 1978 ))) 1979 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**1980 -|(% rowspan="3" %)DSCL|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●||●|●1981 -|Parameter 2| | | | | | | | | | | | | | | | |●|●|●| | | | ||●|●1982 -|Parameter 3| | | | | | | | | | | |●|●|●|●|●|●|●|●|●|●| | ||●|●1974 +|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**[D]**|**XXP** 1975 +|(% rowspan="3" %)DSCL|Parameter 1|●|●|●|●|●|●|●|●|●|●|●|●|●|●|● 1976 +|Parameter 2| | | | | | |●|●|●| | | | |●|● 1977 +|Parameter 3| |●|●|●|●|●|●|●|●|●|●| | |●|● 1983 1983 1984 1984 **Features** 1985 1985 1986 - {{id name="OLE_LINK41"/}}The conversion data (32-bit data unit) for scaling specified in (s2) is scaled by the input value specified in (s1), and the operation result is stored in the device number specified in (d). The scale conversion is performed based on the scale conversion data stored after the device specified in (s2).1981 +The conversion data (32-bit data unit) for scaling specified in (s2) is scaled by the input value specified in (s1), and the operation result is stored in the device number specified in (d). The scale conversion is performed based on the scale conversion data stored after the device specified in (s2). 1987 1987 1988 1988 |(% colspan="2" %)**Set items (n represents the number of coordinate points specified in (s2))**|**Device allocation** 1989 1989 |(% colspan="2" %)Coordinate points|(s2)+1, (s2) ... ... @@ -1995,7 +1995,8 @@ 1995 1995 |(% rowspan="2" %)Point n|X coordinate|(s2)+4n-1, (s2)+4n-2 1996 1996 |Y coordinate|(s2)+4n+1, (s2)+4n 1997 1997 1998 -[[image:07-5 Basic instructions_html_6633ca18cee1218c.png]] 1993 +(% style="text-align:center" %) 1994 +[[image:07-5 Basic instructions_html_6633ca18cee1218c.png||height="379" width="750"]] 1999 1999 2000 2000 • If the calculation result is not an integer value, round the first digit below the decimal point. 2001 2001 ... ... @@ -2011,10 +2011,11 @@ 2011 2011 2012 2012 In the case of scaling conversion characteristics as shown in the figure below, set it as the following data sheet. 2013 2013 2014 -[[image:07-5 Basic instructions_html_74fd22d845ad450e.png]] 2010 +(% style="text-align:center" %) 2011 +[[image:07-5 Basic instructions_html_74fd22d845ad450e.png||height="210" width="750"]] 2015 2015 2016 -|(% colspan="2" rowspan="2" %)**Set items**|(% colspan="3" %)**Set device and content**|(% rowspan="2" %)**Remarks**2017 -|(% colspan="2" %)**When R0 is specified in (s2)**|**Set content**2013 +|(% colspan="2" rowspan="2" %)**Set items**|(% colspan="3" %)**Set device and content**|(% rowspan="2" %)**Remarks** 2014 +|(% colspan="2" %)**When R0 is specified in (s2)**|**Set content** 2018 2018 |(% colspan="2" %)Coordinate points|(s2)+1, (s2)|R1, R0|K10| 2019 2019 |(% rowspan="2" %)Point 1|X coordinate|(s2)+3, (s2)+2|R3, R2|K5| 2020 2020 |Y coordinate|(s2)+5, (s2)+4|R5, R4|K7| ... ... @@ -2062,7 +2062,8 @@ 2062 2062 2063 2063 **Example** 2064 2064 2065 -[[image:07-5 Basic instructions_html_ba95b2d50d8d1d3e.png]] 2062 +(% style="text-align:center" %) 2063 +[[image:07-5 Basic instructions_html_ba95b2d50d8d1d3e.png||height="272" width="404"]] 2066 2066 2067 2067 [[image:07-5 Basic instructions_html_1de79c7d87d51f78.gif]] When -100 ≤ D0(X) < 0, D100(Y)= 2068 2068 ... ... @@ -2070,11 +2070,12 @@ 2070 2070 2071 2071 When 0 < D0(X) ≤ 100, D100(Y)= 2072 2072 2073 -[[image:07-5 Basic instructions_html_a5b19d1af74a9620.png]] 2071 +(% style="text-align:center" %) 2072 +[[image:07-5 Basic instructions_html_a5b19d1af74a9620.png||height="351" width="550"]] 2074 2074 2075 - {{id name="_Toc3776"/}}{{id name="_Toc11170"/}}{{idname="_Toc2957"/}}**SCL2/BIN 16-bit unit scale (X/Y coordinate data)**2074 +== **SCL2/BIN 16-bit unit scale (X/Y coordinate data)** == 2076 2076 2077 - [[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]]**SCL2(P)**2076 +**SCL2(P)** 2078 2078 2079 2079 The conversion data (16-bit data unit) for scaling specified in (s2) is scaled by the input value specified in (s1), and the operation result is stored in the device specified in (d). 2080 2080 ... ... @@ -2089,15 +2089,13 @@ 2089 2089 2090 2090 **Device used** 2091 2091 2092 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 2093 -**Pulse** 2094 - 2095 -**extension** 2091 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="11" %)**Devices**|**Offset modification**|((( 2092 +**Pulse extension** 2096 2096 ))) 2097 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**2098 -|(% rowspan="3" %)SCL2|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|| |●|●||●|●2099 -|Parameter 2| | | | | | | | | | | | | | | | |●|●|●| | || | |●|●2100 -|Parameter 3| | | | | | | | | | | |●|●|●|●|●|●|●|●| | || | |●|●2094 +|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**K**|**H**|**[D]**|**XXP** 2095 +|(% rowspan="3" %)SCL2|Parameter 1|●|●|●|●|●|●|●|●|●|●|●|●|● 2096 +|Parameter 2| | | | | | |●|●|●| | |●|● 2097 +|Parameter 3| |●|●|●|●|●|●|●|●| | |●|● 2101 2101 2102 2102 **Features** 2103 2103 ... ... @@ -2108,13 +2108,14 @@ 2108 2108 |(% rowspan="4" %)X coordinate|Point 1|(s2)+1 2109 2109 |Point 2|(s2)+2 2110 2110 |.....|...... 2111 -|Point n|(s2)+n2112 -|(% rowspan="4" %)Y coordinate|Point 1|(s2)+ n+12113 -|Point 2|(s2)+ n+22108 +|Point N|(s2)+N 2109 +|(% rowspan="4" %)Y coordinate|Point 1|(s2)+N+1 2110 +|Point 2|(s2)+N+2 2114 2114 |.....|..... 2115 -|Point n|(s2)+2n2112 +|Point N|(s2)+2N 2116 2116 2117 -[[image:07-5 Basic instructions_html_80185ccddb878234.png]] 2114 +(% style="text-align:center" %) 2115 +[[image:07-5 Basic instructions_html_80185ccddb878234.png||height="422" width="750"]] 2118 2118 2119 2119 • If the operation result is not an integer value, round the first digit below the decimal point. 2120 2120 ... ... @@ -2130,7 +2130,8 @@ 2130 2130 2131 2131 In the case of scaling conversion characteristics as shown in the figure below, set it as the following data sheet. 2132 2132 2133 -[[image:07-5 Basic instructions_html_74fd22d845ad450e.png]] 2131 +(% style="text-align:center" %) 2132 +[[image:07-5 Basic instructions_html_74fd22d845ad450e.png||height="210" width="750"]] 2134 2134 2135 2135 |(% colspan="2" rowspan="2" %)**Set items**|(% colspan="3" %)**Set device and content**|(% rowspan="2" %)**Remarks** 2136 2136 |(% colspan="2" %)**When R0 is specified in (s2)**|**Set content** ... ... @@ -2179,21 +2179,23 @@ 2179 2179 When the number of start coordinate points of device (s2) is less than 0. 2180 2180 ))) 2181 2181 2182 -**Example** 2181 +**Example** 2183 2183 2184 -[[image:07-5 Basic instructions_html_ace075fb7675de8e.gif]] [[image:07-5 Basic instructions_html_de529c9a16a62ef0.png]] 2183 +(% style="text-align:center" %) 2184 +[[image:07-5 Basic instructions_html_de529c9a16a62ef0.png||height="316" width="400"]] 2185 2185 2186 -When -100 ≤D0 (X) < 0, D100(Y)= 2186 +When -100 ≤D0 (X) < 0, D100(Y)=[[image:07-5 Basic instructions_html_ace075fb7675de8e.gif]] 2187 2187 2188 - [[image:07-5 Basic instructions_html_9acd6306c6d91847.gif]] when D0(X)=0, D100(Y)=0;2188 +When D0(X)=0, D100(Y)=0; 2189 2189 2190 - when 0 < D0(X) ≤ 100, D100(Y)=2190 +When 0 < D0(X) ≤ 100, D100(Y)=[[image:/xwiki/bin/download/PLC%20Editor2/1%20User%20manual/2.1%20LX5V%20user%20manual/07-5%20Basic%20instruction/WebHome/07-5%20Basic%20instructions_html_47ebf5cc7733fccc.gif?rev=1.1||alt="07-5 Basic instructions_html_47ebf5cc7733fccc.gif"]],,[[image:07-5 Basic instructions_html_47ebf5cc7733fccc.gif]],, 2191 2191 2192 -[[image:07-5 Basic instructions_html_a5b19d1af74a9620.png]] 2192 +(% style="text-align:center" %) 2193 +[[image:07-5 Basic instructions_html_a5b19d1af74a9620.png||height="351" width="550"]] 2193 2193 2194 - {{id name="_Toc5608"/}}{{id name="_Toc1756"/}}{{idname="_Toc21402"/}}**DSCL2/BIN 32-bit unit scale (X/Y coordinate data)**2195 +== **DSCL2/BIN 32-bit unit scale (X/Y coordinate data)** == 2195 2195 2196 - [[image:07-5 Basic instructions_html_11b3991e89e21efc.gif]]**DSCL2(P)**2197 +**DSCL2(P)** 2197 2197 2198 2198 The conversion data (32-bit data unit) for scaling specified in (s2) is scaled by the input value specified in (s1), and the operation result is stored in the device specified in (d). 2199 2199 ... ... @@ -2208,15 +2208,13 @@ 2208 2208 2209 2209 **Device used** 2210 2210 2211 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|**Offset modification**|((( 2212 -**Pulse** 2213 - 2214 -**extension** 2212 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="13" %)**Devices**|**Offset modification**|((( 2213 +**Pulse extension** 2215 2215 ))) 2216 -|** X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**2217 -|(% rowspan="3" %)DSCL2|Parameter 1| | | | | | | | | | |●|●|●|●|●|●|●|●|●|●|●|●|●||●|●2218 -|Parameter 2| | | | | | | | | | | | | | | | |●|●|●| | | | ||●|●2219 -|Parameter 3| | | | | | | | | | | |●|●|●|●|●|●|●|●|●|●| | ||●|●2215 +|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**[D]**|**XXP** 2216 +|(% rowspan="3" %)DSCL2|Parameter 1|●|●|●|●|●|●|●|●|●|●|●|●|●|●|● 2217 +|Parameter 2| | | | | | |●|●|●| | | | |●|● 2218 +|Parameter 3| |●|●|●|●|●|●|●|●|●|●| | |●|● 2220 2220 2221 2221 **Features** 2222 2222 ... ... @@ -2227,13 +2227,14 @@ 2227 2227 |(% rowspan="4" %)X coordinate|Point 1|(s2)+3, (s2)+2 2228 2228 |Point 2|(s2)+5, (s2)+4 2229 2229 |.....|...... 2230 -|Point n|(s2)+2n+1, (s2)+2n2231 -|(% rowspan="4" %)Y coordinate|Point 1|(s2)+2 n+3, (s2)+2n+22232 -|Point 2|(s2)+2 n+5, (s2)+2n+42229 +|Point N|(s2)+2N+1, (s2)+2N 2230 +|(% rowspan="4" %)Y coordinate|Point 1|(s2)+2N+3, (s2)+2N+2 2231 +|Point 2|(s2)+2N+5, (s2)+2N+4 2233 2233 |.....|..... 2234 -|Point n|(s2)+4n+1, (s2)+4n2233 +|Point N|(s2)+4N+1, (s2)+4N 2235 2235 2236 -[[image:07-5 Basic instructions_html_6633ca18cee1218c.png]] 2235 +(% style="text-align:center" %) 2236 +[[image:07-5 Basic instructions_html_6633ca18cee1218c.png||height="379" width="750"]] 2237 2237 2238 2238 • If the operation result is not an integer value, round the first digit below the decimal point. 2239 2239 ... ... @@ -2249,9 +2249,10 @@ 2249 2249 2250 2250 In the case of scaling conversion characteristics as shown in the figure below, set it as the following data sheet. 2251 2251 2252 -[[image:07-5 Basic instructions_html_74fd22d845ad450e.png]] 2252 +(% style="text-align:center" %) 2253 +[[image:07-5 Basic instructions_html_74fd22d845ad450e.png||height="210" width="750"]] 2253 2253 2254 -|(% colspan="2" rowspan="2" %)**Set items**|(% colspan="3" %)**Set device and content**|(% rowspan="2" %)**Remarks**2255 +|(% colspan="2" rowspan="2" %)**Set items**|(% colspan="3" %)**Set device and content**|(% rowspan="2" %)**Remarks** 2255 2255 |(% colspan="2" %)**When R0 is specified in (s2)**|**Set content** 2256 2256 |(% colspan="2" %)Coordinate points|(s2)+1, (s2)|R1, R0|K10| 2257 2257 |(% rowspan="10" %)X|Point 1|(s2)+3, (s2)+2|R3, R2|K5| ... ... @@ -2300,6 +2300,7 @@ 2300 2300 2301 2301 **Example** 2302 2302 2304 +(% style="text-align:center" %) 2303 2303 [[image:07-5 Basic instructions_html_91dbc16faa9d2ec3.png]] 2304 2304 2305 2305 When -100 ≤D0(X) < 0, D100(Y)=[[image:/xwiki/bin/download/PLC%20Editor2/1%20User%20manual/2.1%20LX5V%20user%20manual/07-5%20Basic%20instruction/WebHome/07-5%20Basic%20instructions_html_2c96d630f666e72c.gif?rev=1.1||alt="07-5 Basic instructions_html_2c96d630f666e72c.gif"]],,[[image:07-5 Basic instructions_html_2c96d630f666e72c.gif]] ,,; ... ... @@ -2308,7 +2308,8 @@ 2308 2308 2309 2309 when 0< D0(X) ≤ 100, D100(Y)=[[image:/xwiki/bin/download/PLC%20Editor2/1%20User%20manual/2.1%20LX5V%20user%20manual/07-5%20Basic%20instruction/WebHome/07-5%20Basic%20instructions_html_47ebf5cc7733fccc.gif?rev=1.1||alt="07-5 Basic instructions_html_47ebf5cc7733fccc.gif"]],,[[image:07-5 Basic instructions_html_47ebf5cc7733fccc.gif]] ,,. 2310 2310 2311 -[[image:07-5 Basic instructions_html_a5b19d1af74a9620.png]] 2313 +(% style="text-align:center" %) 2314 +[[image:07-5 Basic instructions_html_a5b19d1af74a9620.png||height="351" width="550"]] 2312 2312 2313 2313 {{id name="_Toc32057"/}}{{id name="_Toc9941"/}}{{id name="_Toc6492"/}}**ZONE/BIN 16-bit data zone control** 2314 2314