Changes for page 12 Clock operation
Last modified by Mora Zhou on 2023/11/21 17:27
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 11 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bob1 +XWiki.Mora - Content
-
... ... @@ -68,11 +68,12 @@ 68 68 |SM151|Carry|It is ON when the result of the TADD(P) instruction exceeds the maximum clock data value of 23:59:59 69 69 |SM153|Zero|It is ON when the result of the TADD(P) instruction is 0:00:00 70 70 71 -✎**Note:** 71 +(% class="box infomessage" %) 72 +((( 73 +✎**Note:** The devices specified in (s1), (s2), (d) occupy 3 points respectively. Be careful not to overlap with the device used for machine control. 72 72 73 -The devices specified in (s1), (s2), (d) occupy 3 points respectively. Be careful not to overlap with the device used for machine control. 74 - 75 75 When using the clock data time (hour, minute, second) of the built-in real-time clock of the CPU module, use the TRD(P) instruction to read the value of the special register and assign the word device to each operand. 76 +))) 76 76 77 77 **Error code** 78 78 ... ... @@ -933,7 +933,8 @@ 933 933 934 934 **Timing Chart** 935 935 936 -[[image:企业微信截图_16691725418532.png]] 937 +(% style="text-align:center" %) 938 +[[image:图片3.png]] 937 937 938 938 **Features** 939 939 ... ... @@ -962,7 +962,8 @@ 962 962 963 963 **Example** 964 964 965 -[[image:企业微信截图_16691729278938.png]] 967 +(% style="text-align:center" %) 968 +[[image:图片4.png]] 966 966 967 967 T1 is used for storing time, setting the expected time as K10 and the time base as K10000. 968 968 ... ... @@ -972,7 +972,7 @@ 972 972 973 973 == **TONR/BIN 16-bit Hold-type turn-on delay timer** == 974 974 975 - [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\ksohtml8784\wps1.png]]**TONR(P)**978 +**TONR(P)** 976 976 977 977 Specify the T timer device in (s1), the expected time in (s2), and the time base (resolution) in (s3). And store the time values of the accumulated multiple timing intervals into the device specified in (s1). 978 978 ... ... @@ -997,7 +997,8 @@ 997 997 998 998 **Timing Chart** 999 999 1000 -[[image:企业微信截图_16691733488965.png]] 1003 +(% style="text-align:center" %) 1004 +[[image:图片2.png]] 1001 1001 1002 1002 **Features** 1003 1003 ... ... @@ -1028,7 +1028,8 @@ 1028 1028 1029 1029 **Example** 1030 1030 1031 -[[image:企业微信截图_16691733566206.png]] 1035 +(% style="text-align:center" %) 1036 +[[image:图片1.png]] 1032 1032 1033 1033 T1 is used for storing time, setting the expected time as K10 and the time base as K10000. 1034 1034 ... ... @@ -1038,7 +1038,7 @@ 1038 1038 1039 1039 == **TOF/BIN 16-bit Turn-off delay timer** == 1040 1040 1041 - [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\ksohtml8784\wps6.png]]**TOF(P)**1046 +**TOF(P)** 1042 1042 1043 1043 Specify the T timer device in (s1), the expected time in (s2), and the time base (resolution) in (s3). And store the time values of the accumulated multiple timing intervals into the device specified in (s1). 1044 1044 ... ... @@ -1063,7 +1063,8 @@ 1063 1063 1064 1064 **Timing Chart** 1065 1065 1066 -[[image:企业微信截图_16691735325382.png]] 1071 +(% style="text-align:center" %) 1072 +[[image:图片5.png]] 1067 1067 1068 1068 **Features** 1069 1069 ... ... @@ -1094,7 +1094,8 @@ 1094 1094 1095 1095 **Example** 1096 1096 1097 -[[image:企业微信截图_16691735281572.png]] 1103 +(% style="text-align:center" %) 1104 +[[image:图片6.png]] 1098 1098 1099 1099 T1 is used for storing time, setting the expected time as K10 and the time base as K10000. 1100 1100 ... ... @@ -1130,7 +1130,7 @@ 1130 1130 **Timing Chart** 1131 1131 1132 1132 (% style="text-align:center" %) 1133 -[[image: 企业微信截图_16691747709508.png]]1140 +[[image:图片7.png]] 1134 1134 1135 1135 **Features** 1136 1136 ... ... @@ -1164,9 +1164,8 @@ 1164 1164 **Example** 1165 1165 1166 1166 (% style="text-align:center" %) 1167 -[[image: 企业微信截图_1669174775341.png]]1174 +[[image:图片8.png]] 1168 1168 1169 - 1170 1170 T1 is used for storing time, setting the expected time as K5 and the time base as K10000. 1171 1171 1172 1172 When the enable input (M8) is on, the timer (T1) is started and the timer (T1) bit turns on immediately. Timer (T1) stops as time increases and reaches the expected time.
- 企业微信截图_16692613377006.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +17.1 KB - Content
- 企业微信截图_16692614835389.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +4.8 KB - Content
- 企业微信截图_16692615431415.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.1 KB - Content
- 图片1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +4.4 KB - Content
- 图片2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.7 KB - Content
- 图片3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.3 KB - Content
- 图片4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.1 KB - Content
- 图片5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.8 KB - Content
- 图片6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.2 KB - Content
- 图片7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.9 KB - Content
- 图片8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bob - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.0 KB - Content