Changes for page 08 High-speed pulse output
Last modified by Mora Zhou on 2024/08/08 14:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -986,21 +986,21 @@ 986 986 **Content, range and data type** 987 987 988 988 (% class="table-bordered" %) 989 -|**Parameter**|(% style="width: 702px" %)**Content**|(% style="width:183px" %)**Range**|**Data type**|**Data type (label)**990 -|(s1)|(% style="width: 702px" %)The ON time or the device number storing the ON time|(% style="width:183px" %)0 to 32,767|Signed BIN16|ANY16_S991 -|(s2)|(% style="width: 702px" %)Cycle or the device number storing the cycle|(% style="width:183px" %)1 to 32,767|Signed BIN16|ANY16_S992 -|(d)|(% style="width: 702px" %)The channel number and device number that pulse outputs|(% style="width:183px" %)-|Bit|ANY_BOOL989 +|=(% scope="row" %)**Parameter**|=(% style="width: 618px;" %)**Content**|=(% style="width: 121px;" %)**Range**|=(% style="width: 132px;" %)**Data type**|=(% style="width: 118px;" %)**Data type (label)** 990 +|=(s1)|(% style="width:618px" %)The ON time or the device number storing the ON time|(% style="width:121px" %)0 to 32,767|(% style="width:132px" %)Signed BIN16|(% style="width:118px" %)ANY16_S 991 +|=(s2)|(% style="width:618px" %)Cycle or the device number storing the cycle|(% style="width:121px" %)1 to 32,767|(% style="width:132px" %)Signed BIN16|(% style="width:118px" %)ANY16_S 992 +|=(d)|(% style="width:618px" %)The channel number and device number that pulse outputs|(% style="width:121px" %)-|(% style="width:132px" %)Bit|(% style="width:118px" %)ANY_BOOL 993 993 994 994 **Device used** 995 995 996 996 (% class="table-bordered" %) 997 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="11" %)**Devices**|**Offset modification**|((( 997 +|=(% rowspan="2" %)**Instruction**|=(% rowspan="2" %)**Parameter**|=(% colspan="11" %)**Devices**|=**Offset modification**|=((( 998 998 **Pulse** 999 999 1000 1000 **extension** 1001 1001 ))) 1002 -|**Y**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**K**|**H**|**[D]**|**XXP** 1003 -|(% rowspan="3" %)PWM|Parameter 1| |●|●|●|●|●|●|●|●|●|●|●| 1002 +|=**Y**|=**KnX**|=**KnY**|=**KnM**|=**KnS**|=**T**|=**C**|=**D**|=**R**|=**K**|=**H**|=**[D]**|=**XXP** 1003 +|=(% rowspan="3" %)PWM|Parameter 1| |●|●|●|●|●|●|●|●|●|●|●| 1004 1004 |Parameter 2| |●|●|●|●|●|●|●|●|●|●|●| 1005 1005 |Parameter 3|●| | | | | | | | | | | | 1006 1006 ... ... @@ -1032,16 +1032,20 @@ 1032 1032 **Related device** 1033 1033 1034 1034 (% class="table-bordered" %) 1035 -|**Output shaft**|**Y0**|**Y1**|**Y2**|**Y3**|**Y4**|**Y5**|**Y6**|**Y7** 1036 -|Percentage mode sign|SM897|SM957|SM1017|SM1077|SM1137|SM1197|SM1257|SM1317 1035 +|=(% scope="row" style="width: 233px;" %)**Output shaft**|=(% style="width: 81px;" %)**Y0**|=(% style="width: 104px;" %)**Y1**|=(% style="width: 111px;" %)**Y2**|=(% style="width: 107px;" %)**Y3**|=(% style="width: 108px;" %)**Y4**|=(% style="width: 108px;" %)**Y5**|=(% style="width: 115px;" %)**Y6**|=**Y7** 1036 +|=(% style="width: 233px;" %)Percentage mode sign|(% style="width:81px" %)SM897|(% style="width:104px" %)SM957|(% style="width:111px" %)SM1017|(% style="width:107px" %)SM1077|(% style="width:108px" %)SM1137|(% style="width:108px" %)SM1197|(% style="width:115px" %)SM1257|SM1317 1037 1037 1038 +|=(% scope="row" style="width: 217px;" %)**Output shaft**|=(% style="width: 105px;" %)**Y0**|=**Y1**|=**Y2**|=**Y3**|=**Y4**|=**Y5**|=**Y6**|=**Y7** 1039 +|=(% style="width: 217px;" %)PWM unit selection|(% style="width:105px" %)SM902|SM962|SM1022|SM1082|SM1142|SM1202|SM1262|SM1322 1040 +|(% colspan="9" scope="row" %)Take Y0 as an example: When SM902 is OFF, the Y0 PWM output cycle and pulse width are in "ms"; When SM902 is ON, the Y0 PWM output cycle and pulse width are in "us". 1041 + 1038 1038 **Error code** 1039 1039 1040 1040 (% class="table-bordered" %) 1041 -|**Error code**|**Content** 1042 -|4084H|The data input in the application instruction (s1) and (s2) exceed the specified range or (s1)>(s2) 1043 -|4085H|The result output in the read application instruction (s1), (s2) and (d) exceed the device range 1044 -|4088H|The same pulse output axis (d) is used and has been started. 1045 +|=(% scope="row" %)**Error code**|=**Content** 1046 +|=4084H|The data input in the application instruction (s1) and (s2) exceed the specified range or (s1)>(s2) 1047 +|=4085H|The result output in the read application instruction (s1), (s2) and (d) exceed the device range 1048 +|=4088H|The same pulse output axis (d) is used and has been started. 1045 1045 1046 1046 **Example** 1047 1047 ... ... @@ -1048,10 +1048,10 @@ 1048 1048 (% style="text-align:center" %) 1049 1049 [[image:08_html_3ed5f1836c38d129.png||class="img-thumbnail"]] 1050 1050 1051 -The waveform diagram is shown as right.1055 +The waveform diagram is shown as below. 1052 1052 1053 1053 (% style="text-align:center" %) 1054 -[[image:08_html_f38f59f98fdc96c0.png||height=" 213" width="600" class="img-thumbnail"]]1058 +[[image:08_html_f38f59f98fdc96c0.png||height="174" width="477" class="img-thumbnail"]] 1055 1055 1056 1056 = **PWM/PWM perimeter mode** = 1057 1057